T2 Cover Manual
User Manual: Pdf Manual
Open the PDF directly: View PDF .
Page Count: 21
ENGLISH
2Tennant T2 (08--11)
ESPAÑOL 22......................................
FRANÇAIS 42.....................................
This manual is furnished with each new model.
It provides necessary operation and maintenance
instructions.
Read this manual completel
y
and
understand the machine before
operating or servicing it.
This machine will provide excellent service. However,
the best results will be obtained at minimum costs if:
SThe machine is operated with reasonable care.
SThe machine is maintained regularly - per the
machine maintenance instructions provided.
SThe machine is maintained with manufacturer
supplied or equivalent parts.
Use the Parts Manual to order replacement parts.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials,
old machine components such as bat-
teries, hazardous fluids such as anti-
freeze and oil, in a safe environmental-
ly way according to your local waste
disposal regulations.
Always remember to recycle.
Tennant Company
PO Box 1452
Minneapolis, MN 55440 USA
Phone: (800) 553--8033 or (763) 513--2850
www.tennantco.com
Specifications and parts are subject to change without notice.
Original instructions, copyright E2011 Tennant Company. All rights reserved.
Printed in USA.
MACHINE DATA
Please fill out at time of installation for future reference.
Model No. --
Serial No. --
Machine Options --
Sales Rep. --
Sales Rep. phone no. --
Customer Number --
Installation Date --
TABLE OF CONTENTS
SAFETY PRECAUTIONS 3....................
SAFETY LABELS 4...........................
MACHINE COMPONENTS 5...................
MACHINE OPERATION SYMBOLS 5...........
MACHINE INSTALLATION 6...................
HOW THE MACHINE WORKS 7...............
BRUSH AND PAD INFORMATION 7............
MACHINE SETUP 7..........................
MACHINE OPERATION 10.....................
DRAINING TANKS 12..........................
CHARGING BATTERIES 13....................
MACHINE MAINTENANCE 15..................
TRANSPORTING MACHINE 18.................
STORING MACHINE 18........................
TROUBLESHOOTING 19.......................
SPECIFICATIONS 21..........................
MACHINE DIMENSIONS 21....................
ENGLISH
Tennant T2 (08--11) 3
SAFETY PRECAUTIONS
This machine is intended for commercial use. It is
designed exclusively to scrub hard floors in an
indoor environment and is not constructed for any
other use.
The following warning alert symbol and the “FOR
SAFETY” heading are used throughout this manual as
indicated in their description:
WARNING: To warn of hazards or unsafe
practices which could result in severe personal
injury or death.
FOR SAFETY: To identify actions which must be
followed for safe operation of equipment.
All operators must read, understand and practice
the following safety precautions.
The following safety precautions signal potentially
dangerous conditions to the operator or
equipment.
WARNING: Fire Or Explosion Hazard:
-- Do Not Pick Up Flammable Materials.
-- Do Not Use Near Flammable Liquids, Vapors Or
Combustible Dusts.
-- Only Use Commercially Approved Floor
Cleaners Intended for Machine Application.
-- Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
WARNING: Electrical Hazard
-- Disconnect Battery Cables and Charger Plug
Before Servicing Machine.
-- Do Not Charge Batteries with Damaged Power
Supply Cord. Do Not Modify Plug.
If the charger supply cord is damaged or broken, it
must be replaced by the manufacturer or its
service agent or a similarly qualified person in
order to avoid a hazard.
WARNING: Spinning Brush. Keep Hands
Away. Turn Off Power Before Working On Machine.
FOR SAFETY:
1. Do not operate machine:
-- In an area where flammable liquids/vapors
or combustible dusts are present.
-- Unless trained and authorized.
-- Unless operator manual is read and
understood.
-- If not in proper operating condition.
-- Unless mentally and physically capable of
following machine instructions.
-- Outdoors.
-- If battery emits an unusual odor. Move
machine to a ventilated area and contact
Customer Service immediately.
-- If battery is leaking any substance. Avoid
contact with battery substance and contact
Customer Service immediately.
-- If battery becomes excessively hot.
Disconnect battery charger. Move machine
to a ventilated area and contact Customer
Service immediately.
2. Before starting machine:
-- Make sure all safety devices are in place
and operate properly.
-- Follow safety guidelines concerning wet
floors.
3. When using machine:
-- Do not operate on inclines.
-- Wear non--slip shoes.
-- Reduce speed when turning.
-- Report machine damage or faulty operation
immediately.
-- Do not allow children to play on or around
machine.
-- Follow mixing and handling instructions on
chemical containers.
4. Before leaving or servicing machine:
-- Stop on level surface.
-- Turn off machine.
-- Set parking brake if equipped.
-- Remove key.
5. When servicing machine:
-- Avoid moving parts. Do not wear loose
clothing or jewelry
-- Disconnect battery connections before
working on machine.
-- Wear protective gloves and eye protection
when handling batteries or battery cables.
-- Avoid contact with battery acid.
-- Do not power spray or hose off machine.
Electrical malfunction may occur.
-- Use manufacturer supplied or approved
replacement parts.
-- All repairs must be performed by a
qualified service person.
-- Do not modify the machine from its original
design.
ENGLISH
4Tennant T2 (08--11)
6. When transporting machine:
-- Drain tanks before loading.
-- Turn machine off.
-- Do not lift machine when batteries are
installed.
-- Get assistance or use a mechanical lift
when lifting machine.
-- Use a recommended ramp when
loading/unloading into/off truck or trailer.
-- Use tie--down straps to secure machine to
truck or trailer.
-- Put scrub head in the lowered position.
-- Set parking brake if equipped.
SAFETY LABELS
The safety labels appear on the machine in the locations indicated. Replace labels if they are missing or become
damaged or illegible.
SPINNING BRUSH LABEL --
Located on scrub head
WARNING: Spinning Brush. Keep
Hands Away. Turn Off Power Before
Working On Machine.
BATTERY CHARGE LABEL --
Located at bottom side of recovery tank.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks
And Open Flame Away. Keep Battery
Compartment Open When Charging.
ENGLISH
Tennant T2 (08--11) 5
MACHINE COMPONENTS
19
5
24
4
7
9
10 14
15
8
16
17
12
11
6
23
25
26 27
22
21
20
18
28
3
1
2
13
13
29
1. Main Power Key Switch
2. Start Triggers
3. Battery Discharge Indicator
4. Adjustable Control Handle
5. Squeegee Lift Lever
6. Control Console Height Adjustment Knob
7. Recovery Tank Drain Hose
8. Brush Motor Circuit Breaker Button
9. On--board Battery Charger Power Cord
10. Scrub Head Lift Pedal
11. Squeegee Vacuum Hose
12. Squeegee Assembly
13. Wall Roller
14. On--board Battery Charger
15. Hour Meter
16. Solution Tank Fill Gauge/Drain Hose
17. Squeegee Storage Bracket
18. Cup Holder
19. Recovery Tank Cover
20. Recovery Tank
21. Solution Tank Fill--Port
22. Solution Tank
23. Pad Driver/Brush Lock Release Button
24. Pad Driver Window
25. Scrub Head
26. Scrub Head Skirt
27. Solution Flow Control Knob
28. Battery Compartment
29. Charger Plug Connector
MACHINE OPERATION SYMBOLS
2% (1) Maximum
Grade Level
Main Power
I/O Key Switch
Solution Flow
Control Brush Motor
Circuit Breaker Parking Brake
(option)
Battery Discharge
Indicator
ENGLISH
6Tennant T2 (08--11)
MACHINE INSTALLATION
UNCRATING MACHINE
1. Carefully check the shipping crate for signs of
damage. Report damages at once to carrier.
2. Check the contents list. Contact distributor for
missing items.
Contents:
S12V Batteries (Optional)
S2--Foam Battery Spacers
SBattery Tray
SBattery Cable
SBattery Terminal Boots (4)
SSqueegee Assembly
SPad Driver/Brush (Optional)
3. Roll machine off pallet using the attached ramp.
ATTENTION: Do not roll machine off pallet unless
ramp is used, machine damage may occur.
INSTALLING BATTERIES
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Hood Open When
Charging.
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
Battery Specifications:
Two 12 volt, 105Ah/20h lead acid (578426) deep cycle
batteries.
1. Park the machine on a level surface and remove
the key.
2. Carefully install the batteries into the battery
compartment as shown (Figure 1).
3. Connect the battery cables as shown (Figure 1).
Machine Front
105Ah
RED
BLK
Foam Spacers
FIG. 1
IMPORTANT: If your machine is equipped with the
on--board battery charger, make sure that the
charger is properly set for your battery type before
charging (See USING THE ON--BOARD BATTERY
CHARGER).
ENGLISH
Tennant T2 (08--11) 7
HOW THE MACHINE WORKS
Water and detergent from the solution tank flow to the
floor through a manually controlled solution valve. The
brush uses the detergent and water solution to scrub
the floor clean. As the machine moves forward, the
squeegee wipes the dirty solution from the floor into the
recovery tank.
BRUSH AND PAD INFORMATION
For best cleaning results use the appropriate brush
type for your cleaning application. Refer to the Parts
manual for part number information.
Polypropylene Bristle Scrub Brush (Black) --
Part No. 1016765
This general purpose polypropylene bristle scrub brush
is used for scrubbing lightly compacted soilage. This
brush works well for maintaining concrete, wood and
grouted tile floors.
Soft Nylon Bristle Scrub Brush (White) --
Part No. 1016764
Recommended for cleaning coated floors without
removing finish. Cleans without scuffing.
Super Abrasive Bristle Scrub Brush (Gray) --
Part No. 1016763
Nylon fiber impregnated with abrasive grit to remove
stains and soilage. Strong action on any surface.
Performs well on buildup, grease, or tire marks.
Polishing Pad (White) --
Used to maintain highly polished or burnished floors.
Buffing Pad (Red) --
Used for light duty scrubbing without removing floor
finish.
Scrubbing Pad (Blue) --
Used for medium to heavy--duty scrubbing. Removes
dirt, spills, and scuffs and leaves surface clean ready
for recoating.
Stripping Pad (Brown) --
Used for stripping of floor finish to prepare the floor for
recoating.
Heavy Duty Stripping Pad (Black) -- Used for
aggressive stripping of heavy finishes/sealers, or very
heavy duty scrubbing.
MACHINE SETUP
ATTACHING SQUEEGEE ASSEMBLY
1. Park machine on a level surface and remove key.
2. Raise the squeegee mount bracket by moving the
squeegee lift lever to the right (Figure 2).
FIG. 2
3. Mount the squeegee assembly to the squeegee
pivot bracket as shown (Figure 3). Make sure the
knobs are completely seated into the slots before
securing knobs.
FIG. 3
4. Connect the vacuum hose to the squeegee
assembly. Loop the hose as shown using the hose
clip provided (Figure 4).
FIG. 4
ENGLISH
8Tennant T2 (08--11)
5. Check the squeegee blades for proper deflection.
The blades should deflect as shown (Figure 5).
FIG. 5
6. To adjust the blade deflection, place the squeegee
assembly on a level surface and adjust the casters
as shown (Figure 6).
4mm
5/32”
FIG. 6
7. When transporting or storing machine, remove the
squeegee assembly and hang it on the storage
bracket (Figure 7).
FIG. 7
INSTALLING BRUSHES/PADS
FOR SAFETY: Before installing brushes or pad
drivers, stop machine on level surface, remove key
and set parking brake if equipped.
1. Park the machine on a level surface and remove
key.
2. Step down on the scrub head lift pedal to raise the
scrub head off the floor (Figure 8).
FIG. 8
3. Attach the pad to the pad driver and secure pad
with centerlock (Figure 9).
FIG. 9
4. Turn the brush motor hub until the slot with the
spring clip is visible through the scrub head
window (Figure 10).
Spring
Clip
FIG. 10
ENGLISH
Tennant T2 (08--11) 9
5. Align the pad driver/brush mounting studs with
motor hub slots and give the pad driver/brush a
quick counter--clockwise turn to engage spring clip
(Figure 11).
Spring
Clip
Pad Driver/Brush
Mounting Stud
Motor
Hub Slot
FIG. 11
6. To remove the pad driver/ brush, press down on
the motor hub lock pin and turn the pad
driver/brush clockwise (Figure 12).
Lock Pin
FIG. 12
7. When transporting or storing machine, remove the
brush and hang it on the storage strap (Figure 13).
FIG. 13
FILLING SOLUTION TANK
Remove the solution tank cover and fill the tank with 6.9
gallons/26 liters of water (<140F/60C temperature). Do
not fill beyond the “MAX” level (Figure 14).
NOTE: When filling the solution tank with a bucket,
make sure that the bucket is clean. Do not use the
same bucket for filling and draining the machine.
FIG. 14
Pour a recommended cleaning detergent into the
solution tank according to mixing instructions on the
bottle.
ATTENTION: Only use recommended cleaning
detergents. Machine damage due to improper
detergent usage will void the manufacturer’s
warranty.
WARNING: Fire or Explosion Hazard.
Never Use Flammable Liquids.
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
ADJUSTING CONTROL CONSOLE HEIGHT
Loosen the control console height adjustment knob and
lift or lower the console to a comfortable operating
height. Tighten knob to lock in position (Figure 15).
FIG. 15
ENGLISH
10 Tennant T2 (08--11)
MACHINE OPERATION
FOR SAFETY: Do not operate machine, unless
operator manual is read and understood.
WARNING: Fire Or Explosion Hazard. Never
Operate Machine In Or Near Flammable Liquids,
Vapors Or Combustible Dusts.
PRE--OPERATION CHECKS
-Sweep and dust-mop the floor.
-Check the battery discharge indicator.
-Check pad/brush for wear.
-Check the squeegee blades for wear and proper
adjustment.
-Make sure the recovery tank is empty and the float
shut--off screen and debris tray are clean.
-Check the scrub head skirt for wear.
OPERATING THE MACHINE
1. Turn the main power key switch to the on ( I )
position (Figure 16).
FIG. 16
2. Lower the squeegee assembly to the floor by
moving the squeegee lift lever to the left (Figure
17). The vacuum motor will automatically turn on.
FIG. 17
3. Lower the scrub head to the floor by stepping on
the scrub head lift pedal as shown (Figure 18).
FIG. 18
4. Pull the start triggers and slowly push machine
forward to begin scrubbing (Figure 19).
NOTE: 150--200 feet / 45--60 meters per minute is the
recommended scrubbing speed.
FIG. 19
5. Turn the solution flow control knob to a desired flow
rate (Figure 20).
FIG. 20
6. To stop scrubbing, release the triggers, raise the
scrub head and the squeegee and turn the key to
the off position.
ENGLISH
Tennant T2 (08--11) 11
WHILE OPERATING MACHINE
WARNING: Fire Or Explosion Hazard. Do Not
Pick Up Flammable Materials Or Reactive Metals.
1. Overlap each scrubbing path by 2 in/5 cm.
2. Keep the machine moving to prevent damage to
floor finish.
3. Wipe the squeegee blades with a cloth if blades
leave streaks. Pre-sweep the area to prevent
streaking.
4. Do not operate the machine on inclines.
FOR SAFETY: When using machine, do not
operate on inclines.
5. Pour a recommended foam control solution into the
recovery tank if excessive foam appears.
ATTENTION: Check for excessive foam in the
recovery tank. Empty tank if excessive. Foam may
not activate the shut--off float which may result in
vacuum motor damage.
6. For heavily soiled areas, use the double scrubbing
method. First scrub the area with the squeegee up,
let solution set for 3--5 minutes, then scrub the area
a second time with the squeegee down.
7. When leaving the machine unattended, remove the
key and set the parking brake, if equipped.
BATTERY DISCHARGE INDICATOR
The battery discharge indicator displays the charge
level of the batteries. When the batteries are fully
charged, all indicator lights are lit. As the batteries
discharge, the indicator lights will begin to go out from
right to left.
To prolong the life of the batteries, do not allow the
indicator lights to go beyond the discharge level as
described below.
NOTE: ONLY recharge the batteries when the machine
is used for a total of 30 minutes or more.
When the discharge level reaches the last yellow light,
the light will begin to flash, stop scrubbing and recharge
the batteries (Figure 21). If the red light appears, the
scrubbing function will shut off automatically. This
protects the batteries from total discharge. Recharge
the batteries immediately.
Stop scrubbing and
recharge batteries
FIG. 21
CIRCUIT BREAKER
The machine is equipped with a resettable circuit
breaker to protect the brush motor from damage. The
circuit breaker button is located on the control panel
(Figure 22). If the circuit breaker should trip, determine
the cause, allow the motor to cool, and then manually
reset the circuit breaker button.
FIG. 22
HOUR METER
The hour meter records the number of total hours the
brush motor has been powered on. Use the hour meter
to determine when to perform recommended
maintenance procedures and to record service history
(Figure 23).
FIG. 23
ENGLISH
12 Tennant T2 (08--11)
DRAINING TANKS
The recovery tank should be drained and cleaned out
after every use. The solution tank should be cleaned
out periodically to remove any water deposit buildup.
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine and remove
key.
DRAINING RECOVERY TANK
1. While holding the drain hose upward, remove the
cap and lower hose to drain (Figure 24).
FIG. 24
NOTE: When using a bucket to drain the machine, do
not use the same bucket to fill the solution tank.
2. Open the recovery tank cover and rinse out the
tank (Figure 25).
FIG. 25
3. Clean the float shut-off screen and debris tray
located in the recovery tank (Figure 26).
FIG. 26
DRAINING SOLUTION TANK
To drain any remaining water from the solution tank,
pull the solution tank fill gauge hose off the hose fitting
(Figure 27).
FIG. 27
ENGLISH
Tennant T2 (08--11) 13
CHARGING BATTERIES
ATTENTION: To prolong the life of the batteries
only recharge the batteries if the machine was
used for a total of 30 minutes or more. Do not leave
batteries discharged for lengthy periods.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
FOR SAFETY: When servicing batteries, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
BATTERY CHARGER SPECIFICATIONS:
SCHARGER TYPE:
-- FOR SEALED (Gel) BATTERIES
-- FOR WET (Lead acid) BATTERIES
SOUTPUT VOLTAGE - 24 VOLTS
SOUTPUT CURRENT - 9 AMPS
SAUTOMATIC SHUTOFF CIRCUIT
SFOR DEEP CYCLE BATTERY CHARGING
USING THE ON--BOARD BATTERY CHARGER
IMPORTANT: Before charging batteries, make sure
the charger profile is properly set for your battery
type (ex. lead--acid, gel, etc.). Failure to properly
set charger may result in battery damage.
To determine your battery type, see battery label. If not
specified, contact your battery supplier.
To verify the setting of the charger profile:
During charger start--up, if the red light flashes twice,
the charger is set for wet/lead acid batteries. If the
green light flashes twice, the charger is set for a Gel
batteries (Figure 28).
NOTE: NOTE: Refer to the Charger Profile Switch
Configuration Table for other battery type settings
(Figure 30).
FIG. 28
To change the charger profile:
1. Remove charger from machine (Fig. 29).
2. Remove the plug from the bottom of the charger to
access the profile switches (Fig. 29).
FIG. 29
2. Set the profile switches according to the switch
configuration table (Fig. 30). The charger cord
must be unplugged when resetting.
Charger Profile Switch Configuration Table
Battery Switch 1 2
Wet (lead acid) ON OFF
LM Wet ON ON
(low maintenance)
Gel OFF ON
Exide Gel OFF OFF
FIG. 30
To charge batteries:
1. Transport the machine to a well--ventilated area.
2. Park the machine on a flat, dry surface and turn the
key off.
3. If charging wet (lead acid) batteries check the fluid
level before charging (See BATTERY
MAINTENANCE).
ENGLISH
14 Tennant T2 (08--11)
4. Prop up the recovery tank for ventilation
(Figure 31).
FIG. 31
5. Connect the charger’s AC power supply cord into a
properly grounded receptacle (Figure 32).
NOTE: The machine will not operate when charging.
FIG. 32
6. Once the charging cycle begins, the indicator lights
will progress from red, yellow to green (Figure 33).
When the green indicator light comes on, the
charging cycle is done. Unplug the charger cord.
If the charger detects a problem, the charger will
display an fault code (See ON--BOARD BATTERY
CHARGER FAULT CODES).
FIG. 33
ON--BOARD BATTERY CHARGER FAULT CODES
FAULT CODE FAULT SOLUTION
Yellow Light Flashing Loose charger cable connection Check charger cable connection
Loose or damaged battery cable Check battery cable connections
Unsuitable battery Replace with proper battery
Output short circuit -- damaged output cable Contact Service Center
Internal short circuit -- blown output fuse Replace battery charger
Red Light Flashing Safety timer exceeded maximum charging
time Repeat charging cycle. If error repeats,
replace batteries
ENGLISH
Tennant T2 (08--11) 15
MACHINE MAINTENANCE
To keep the machine in good working condition, follow
the machine maintenance procedures.
WARNING: Electrical Hazard. Disconnect
Battery Cables Before Servicing Machine.
DAILY MAINTENANCE
1. Drain and rinse out the recovery tank (Figure 34).
FIG. 34
2. Remove the debris tray and empty (Figure 35)
FIG. 35
3. Remove and clean the float shut--off screen located
in the recovery tank (Figure 36).
FIG. 36
4. Drain the solution tank (Figure 37)
FIG. 37
5. Remove the pad/brush and clean. Rotate pad or
replace when worn (Figure 38).
FIG. 38
6. Wipe the squeegee blades clean (Figure 39).
When machine is not in use, raise squeegee
assembly off floor or hang on storage bracket.
FIG. 39
ENGLISH
16 Tennant T2 (08--11)
7. Check the condition of the squeegee blade wiping
edge (Figure 40). Rotate blade if worn.
(See SQUEEGEE BLADE REPLACEMENT)
FIG. 40
8. Clean the machine with an all purpose cleaner and
damp cloth (Figure 41).
FOR SAFETY: When cleaning machine, do not
power spray or hose off machine. Electrical
malfunction may occur.
FIG. 41
9. Inspect the condition of the scrub head skirt,
replace if worn or damaged (Figure 42).
FIG. 42
10. Recharge the batteries after a total of 30 minutes
of use or more (Figure 43). (See CHARGING
BATTERIES).
FIG. 43
MONTHLY MAINTENANCE
1. Remove the solution tank filter from underneath the
machine and rinse out the screen (Figure 44).
Make sure the solution tank is empty before
removing filter.
FIG. 44
2. Lead Acid Batteries: Clean the battery tops to
prevent corrosion (See BATTERY
MAINTENANCE).
3. Check for loose battery cable connections.
4. Inspect and clean the recovery tank cover seal
(Figure 45). Replace if damaged.
FIG. 45
ENGLISH
Tennant T2 (08--11) 17
5. Lubricate all pivot points and rollers with silicone
spray then coat with a water resistant grease to
maintain smooth operation.
6. Check the machine for loose nuts and bolts.
7. Check the machine for leaks.
MOTOR MAINTENANCE
Contact an Authorized Tennant Service Center for
carbon brush replacement.
Carbon Brush Replacement Hours
Vacuum Motor 750
Brush Motor 750
WARNING: Electrical Hazard. Disconnect
Battery Cables Before Servicing Machine.
SQUEEGEE BLADE REPLACEMENT
Each squeegee blade has four wiping edges. When the
blades become worn, simply rotate the blades
end-for-end or top-to-bottom for a new wiping edge.
Replace blade if all four edges are worn.
1. Remove the squeegee assembly from the machine.
2. Loosen the band clamp and remove the band from
the squeegee assembly (Figure 46).
FIG. 46
3. Remove and rotate the rear blade to a new wiping
edge. (Figure 47).
FIG. 47
4. Remove the thumb screws from the front blade and
rotate blade end--for--end (Figure 48).
NOTE: Use the 5--slot edge use on VCT flooring (vinyl
composite tile) and the 3--slot edge on grouted tile
floors.
FIG. 48
BATTERY MAINTENANCE (Lead Acid Batteries)
1. Check battery fluid level frequently to prevent
battery damage. The fluid should be at the level
shown (Figure 49). Add distilled water if low. DO
NOT OVERFILL, the fluid may expand and
overflow when charging.
Before Charging After Charging
CORRECT BATTERY FLUID LEVEL:
FIG. 49
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
ENGLISH
18 Tennant T2 (08--11)
2. Clean the batteries to prevent battery corrosion.
Use a scrub brush with a mixture of baking soda
and water (Figure 50).
FOR SAFETY: When cleaning batteries, wear
protective gloves and eye protection. Avoid
contact with battery acid.
FIG. 50
TRANSPORTING MACHINE
When transporting the machine by use of trailer or
truck, be certain to follow the tie--down procedure
below:
1. Raise the scrub head and hang squeegee
squeegee on storage bracket.
2. Load the machine using a recommended loading
ramp.
3. Position the front of machine up against the front of
the trailer or truck and lower the scrub head.
4. Place a block behind each wheel to prevent the
machine from rolling.
5. Secure machine with tie--down straps. Machine is
equipped with two tie--down brackets (Figure 51).
FOR SAFETY: When transporting machine, use a
recommended ramp when loading/unloading
into/off truck or trailer. Use tie--down straps to
secure machine to truck or trailer.
STORING MACHINE
1. Charge the batteries before storing. Never store
the machine with discharged batteries.
2. Drain and rinse the tanks thoroughly.
3. Store the machine in a dry area with the squeegee
and scrub head in the up position.
4. Open the recovery tank cover to promote air
circulation.
ATTENTION: Do not expose machine to rain, store
indoors.
5. If storing machine in freezing temperatures, follow
the FREEZE PROTECTION instructions below.
FREEZE PROTECTION
1. Drain the solution tank and recovery tank of all
water.
2. Empty the solution tank filter located under the
machine (Figure 51).
FIG. 51
3. Pour 1 gallon/4 liters of recreational vehicle (RV)
antifreeze into the solution tank at full strength.
Do not dilute.
4. Turn the machine power on and operate the
solution flow system. Turn the machine off when
the red RV antifreeze is visible.
ENGLISH
Tennant T2 (08--11) 19
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Machine will not operate Discharged batteries Charge batteries
Faulty battery(s) Replace battery(s)
Loose battery cable Tighten loose cable
Faulty key switch Contact Service Center
On--board battery charger will not
operate Plug not connected to power supply Check plug connection
Faulty power supply cord Replace cord
Fault detected. See ON--BOARD BATTERY
CHARGER FAULT CODES
Brush motor will not operate Scrub head is raised off floor Lower scrub head
Tripped brush motor circuit breaker Reset brush circuit breaker button
Faulty scrub head (up/down) switch Contact Service Center
Faulty Control handle triggers Contact Service Center
Faulty brush motor or wiring Contact Service Center
Worn carbon brushes Contact Service Center
Vacuum motor will not operate Squeegee is raised off floor Lower squeegee
Vacuum motor fuse blown Replace 25 Amp fuse
Faulty vacuum motor or wiring Contact Service Center
Worn carbon brushes Contact Service Center
Little or no solution flow Clogged solution tank filter or solution
hose Clean solution tank filter or flush out
solution hose
Clogged solution valve Remove valve and clean
Solution flow control knob set too low Adjust solution control flow knob
Loose screw on control knob Calibrate knob and retighten screw
Poor water pickup Recovery tank is full Drain recovery tank
Loose drain hose cap Tighten cap
Clogged float shut--off screen located
in recovery tank Clean screen
Clogged squeegee assembly Clean squeegee assembly
Worn squeegee blades Replace or rotate squeegee blades
Incorrect Squeegee blade deflection Adjust Squeegee blade height
Loose vacuum hose connections Secure hose connections
Clogged vacuum hose Remove clogged debris
Damaged vacuum hose Replace vacuum hose
Recovery tank cover not in place Properly position cover
Damaged recovery tank cover seal Replace seal
Faulty vacuum motor Contact Service Center
Low battery charge Recharge batteries.
ENGLISH
20 Tennant T2 (08--11)
TROUBLESHOOTING -- Continued
PROBLEM CAUSE SOLUTION
Short run time Batteries not fully charged Fully recharge batteries
Defective batteries Replace battery
Service batteries See BATTERY MAINTENANCE
Faulty battery charger Repair or replace battery charger
ENGLISH
Tennant T2 (08--11) 21
SPECIFICATIONS
T2 MODEL
LENGTH 44.1 in/1120 mm
WIDTH 18.8 in/478 mm
HEIGHT 36.6 in/930 mm
WEIGHT 176 lb/80 Kg, 300 lb/136 Kg with batteries
MINIMUM AISLE TURN 48 in/1219 mm
RECOVERY TANK CAPACITY 9.5 gal/36 L
SOLUTION TANK CAPACITY 6.9 lb/26 L
PRODUCTIVITY RATE (Estimated Actual) 7,234 ft2/672 m2per hour
CLEANING PATH WIDTH 17 in/430 mm
PAD PRESSURE 50 lb/23 Kg
SQUEEGEE WIDTH 27.4 in/696 mm
BRUSH MOTOR 1 hp/0.75 Kw, 230 rpm, 24 V, 37 A
VACUUM MOTOR 0.30 kW, 2--stage 5.7, 24 V, 13 A
WATER LIFT 40 in/100 Mbar
BATTERY CAPACITY (2) 12 V, 105 Ah / 20 hr rate
RUN TIME PER CHARGE 105 Ah Batteries -- Up to 3 hours
ON--BOARD BATTERY CHARGER 100--240 VAC, 5.3 A, 50/60 Hz, 24 VDC, 9 A output
VOLTAGE DC 24 VDC
TOTAL POWER CONSUMPTION 25 Amp nominal
PROTECTION GRADE IPX3
DECIBEL RATING AT OPERATOR’S EAR, INDOORS.* 68 dB(A)
VIBRATIONS AT HAND CONTROLS <2.5m/s2
MAXIMUM GRADE LEVEL 2% (1)
* Measured A--weighted emission sound pressure level, per ISO 11201, in accordance with ISO 4871. Uncertainty value is 2 decibels.
44.1 in/1120 mm
MACHINE DIMENSIONS 18.8 in
478 mm
36.6 in
930 mm
27.1 in/696 mm