BDA 542 PowerCON TRUE 1 TOP... NAC3MX W TOP Neutrik Assembly Instruction EN
2019-03-08
: Pdf Nac3Mx-W-Top Neutrik Assembly-Instruction En NAC3MX-W-TOP_Neutrik_Assembly-Instruction_EN NAC3MX-W-TOP NEUTRIK MARKEN media
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
R ASSEMBLY INSTRUCTION NAC3 M X -W-TOP | power CON TRU E 1 TOP ® A. APPLICATION INSTRUCTION Application: The powerCON TRUE1 system is certified as a connector with breaking capacity according IEC 60320, VDE 0625. It is intended for use as an appliance coupler and interconnection coupler. It serves to supply power to an appliance and from an appliance to other equipment. To be installed by qualified person only. CONNECTOR ASSIGNMENT: APPLIANCE INLET APPLIANCE OUTLET NAC3MPX-TOP NAC3MPX-WOT-TOP APPLIANCE INLET / OUTLET NAC3FPX-TOP NAC3FPX-WOT-TOP NAC3FPX-ST-TOP Power IN Power OUT u Combination NAC3PX-TOP Power IN -w -w PS E JET C 3M NA 16 0 20 250 X-W PS E 25 20 250 PS E JE JET 20 250 T 20 0 25 C 3M NA 16 0 Power OUT X-W 25 20 250 PS E JE T 20 0 25 NAC3FX-W-TOP (Connector) NAC3MX-W-TOP (Plug connector) NAC3FX-W-TOP (Connector) NAC3MX-W-TOP (Plug connector) powerCON TRUE1 TOP line is full backward compatible with the preceding powerCON TRUE1 products. Approval based: VDE EN 60320-1/EN60320-2-2 UL UL 498 / CSA C22.2 No. 182.3 Rating: Cable Type: 250 V ac / 16 A H05VV-F3G 1.0 mm2, Length max. 2 m H05VV-F3G 1.5 - 2.5 mm2 H07RN-F3G 1.5 mm2 White chuck 6.0 - 12.0 mm 250 V ac / 20 A SJTOW, SJOOW 3 x 12 AWG Strain Relief: Cable O.D.: White chuck 6.0 - 12.0 mm UL50E environmental rating Enclosure Type 4 when mated with cord connector NAC3FX-W-TOP or mated with appliance outlet NAC3FPX*-TOP with sealing cover SCNAC-FPX and NAC3PX-TOP with sealing cover SCNAC-PX. B. ASSEMBLY INSTRUCTION A Insert cable into the bushing and housing. Note: “Apply cable pulling lubricant to cable jacket.” 40 50 B Separate the housing from the bushing (cable remain in bushing) mm C3M NA 16 X-W 250 20 250 PS E JET 20 0 25 C3M NA 16 X-W 250 20 250 20 0 25 C PS E JET C i Recommendation: Wire Pulling Lubricant - LUB-I/0.95 from 3M Place the chuck over the cable. TM 2 0 mm [0.787”] 2 0 mm 8 mm [0.787”] [0.32"] D Prepare the cable as shown. PE 23 mm [0.9”] VDE (EN 60320-1/EN60320-2-2) BDA 542 8 mm [0.32"] PE 23 mm [0.9”] UL (UL 498 / CSA C22.2 No. 182.3) Page 1 R ASSEMBLY INSTRUCTION I powerCON TRUE1 TOP - NAC3MX-W-TOP E Insert the wires into the terminals and fasten the screw with Torx size T8. Torx size T8 Wiring Torque Value 0.7 Nm VDE Þ Þ Þ L N UL brown blue green / yellow black white green Important: Align rubber key and latch. C3M NA 16 X-W 250 20 250 PS E JET 20 0 25 2. F 1. Important: Push and turn simultaneously. Slide the chuck onto the insert (1) and then both together into housing (2). Important: Align the chuck and insert by positioning the nose into the keyway. 3. 5. C3M NA 16 Torque Value 2.0 Nm G X-W 250 20 250 PRESS FIRMLY PS E JET 6. 20 0 25 4. Slide the bushing up the cable and tighten it with the tool as shown. Important: Black O-ring to hide to achieve IP protection (6). Wrench size 13 mm (Tool available: Art. No. HTAC) Find more details of powerCON TRUE1 TOP on www.neutrik.com. FOR DISASSEMBLY - OPEN TWIST LOCK! 1. 2. 3. CAUTION Press with screw driver to unlock Turn bushing 360°. Repat step 1 + 2 until bushing is unscrewed. PS E To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no free-dangling cable windings etc.). JET 20 LI 250 EC HTE NS TE IN FORCE 1. 2. SAFETY WARNING For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear. Neutrik AG Neutrik USA Inc. Neutrik (UK) Ltd. Neutrik Vertriebs GmbH Draft. Nr.: BDA 542 I LI USA UK DE / NL / AT/DK T: T: T: T: Update: 11.07.2018 www.neutrik.com +423 / 237 24 24 +1 704 / 972 3050 +44 1983 / 811 441 +49 8131 / 280 890 I F: F: F: F: +423 / 232 53 93 +1 704 / 438 9202 +44 1983 / 811 439 +49 8131 / 280 830 Neutrik France Neutrik Tokyo Ltd. Neutrik Hong Kong Ltd. Neutrik India Pvt. Ltd. FR JP HK IND T: +33 1 / 4131 6750 T: +81 3 / 3663 4733 T: +852 / 2687 6055 T: +91 /982 05 43 424 F: +33 1 / 4131 0511 F: +81 3 / 3663 4796 F: +852 / 2687 6052 F: +91 / 22 26163 540 Data subject to change without prior notice. © 2018 NEUTRIK®. NEUTRIK® are registered trademark of NEUTRI AG. ALL RIGHTS RESERVED. Page 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : NBA Create Date : 2018:10:05 10:26:31+02:00 Modify Date : 2018:10:05 10:26:31+02:00 XMP Toolkit : Adobe XMP Core 5.6-c015 91.163280, 2018/06/22-11:31:03 Format : application/pdf Title : BDA 542 - powerCON TRUE 1 TOP... Creator : NBA Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 19.0 (Windows) Document ID : uuid:f68b1781-5533-41c6-954d-0407e642118c Instance ID : uuid:ad5921a6-cbe9-4dfa-91ed-17c7f040c7b7 Page Count : 2EXIF Metadata provided by EXIF.tools