BAR220 M_R1 Oregon Scientific
2012-08-16
: Pdf Oregon Scientific Bar220 oregon_scientific_bar220 instruction upload
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
1. 2. Artisan Weather Station Model: BAR220 / BAR220A / BAR220U USER MANUAL : set clock / : increase / decrease value of the selected setting; enable / disable clock reception signal 3. ˚C / ˚F: select temperature units; display temperature 4. RESET: Reset unit to default settings 5. DIMMER HI·LO: select display brightness 6. AUTO ON/OFF/DEMO: activate / deactivate colourdance effect; select pre-programmed colour-dance demo 7. Battery compartment 8. AC adaptor socket / temperature sensor • Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects. NOTE If you enter +1 in the time zone setting, this will give you your regional time plus 1 hour. • Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. If you are in the US (BAR220A only) set the clock to: The remote sensor reception icon will show the following status: ICON EN OVERVIEW 4 CHANGE DISPLAY To activate / deactivate display auto-toggle function: 4 5 NOTE The main unit will search only for already registered sensor or new sensor reset within the last 30 minutes. If unit failed to synchronise with remote sensor, reset the sensor or try selecting a different channel (and press RESET) before manually forcing another search. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. 5 6 7 1 • In auto-toggle mode, display will alternate between time, indoor temperature and outdoor temperature. • Slide TOGGLE switch to DEMO. Both the weather icons and the time / temperature displays will auto-toggle. IMPORTANT The colour-dance is only for aesthetic reasons. The weather icons will be displayed in a loop sequence, therefore, the displayed icons have no bearing on actual weather conditions. LED status indicator 2. Wall mount hole 3. Battery compartment CLOCK RECEPTION 4. RESET hole 5. Channel switch This product is designed to synchronise its clock automatically with a clock signal. CLOCK • Weather forecast icons 2. ZONE: time zone offset 3. 4. • To change display brightness: • • EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany. BAR220A: 1 adaptor BAR220U: Use the adaptor supplied to power the unit. • 5. To completely disconnect from power, unplug adaptor from the mains. : main unit batteries low / no battery : signal reception indicator • US: WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado. UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England. Slide DIMMER switch to HI / LO. NOTE Auto toggle mode will be disabled if a button is pressed, but will be enabled again if no button is pressed for 5 seconds. WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather forecast within a 30-50 km (19-31 mile) radius. To enable / disable signal reception: Press and hold reception. to enable or to disable signal MEANING NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. Sunny Clock signal reception indicator: 2 CR2032 batteries for memory backup MEANING To insert batteries: PM: indicate PM 1. Remove the battery compartment cover. Continuous Strong signal 7. Clock / indoor temperature / outdoor temperature 2. Insert the batteries, matching the polarities (+/ -). Flashes No signal 8. IN: indoor temperature is displayed 3. Press RESET after each battery change. : remote sensor reception indicator / outdoor temperature is displayed Battery is low in power NOTE The unit searches for a clock signal everyday at 01:00, 02:00 and 03:00, as well as 3 minutes after switching on or resetting unit. During signal search: No battery installed – only AC adaptor 1) display (i.e., time and temperature) will be turned off temporarily 2) only flashing 3) weather icon will remain lit however the colour will be static. MEANING REAR VIEW SET UP REMOTE SENSOR The main unit can be connected to only 1 remote sensor. 1 1. Slide open the battery door. 2. Insert battery, matching the polarities (+ / -). 3. Select channel then press RESET. 4. Close the battery door. Cloudy 3 4 5 6 7 8 Signal search may take approx. 10 minutes and display will resume thereafter. To view display temporarily during signal search, press any key. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search. DATA TRANSMISSION To set the clock manually, disable the clock signal reception first. SENSOR 1. Press and hold The main unit will automatically search for sensor. 2. Press or selected setting. 3. Press To search for a sensor manually: + together. For best results: • Place the sensor within 30 m (100 ft) of the main unit. • Position the sensor so that it faces the main unit, minimizing obstructions such as doors, walls and furniture. • • Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. • The contents of this manual may not be reproduced without the permission of the manufacturer. • Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. • Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer. Place the sensor out of direct sunlight and moisture. to confirm. The settings order is: time zone offset, 12/24 hr format, hour, minute. Time zone offset sets the clock +/- 23 hours from the received clock signal time. If you have deactivated the clock signal reception, do not set a value for time zone. DESCRIPTION Dimensions LxWxH 100 x 195 x 70 mm (3.9 x 7.7 x 2.8 in) Weight 296 g (10.4 oz) without battery Temperature range -5°C to 50°C (23°F to 122°F) Power AC/DC 6V adaptor 2 x CR2032 batteries (for back-up) TYPE DESCRIPTION Dimensions LxWxH 50 x 23 x 95 mm (1.97 x 0.9 x 3.74 in) Weight 50 g (1.76 oz) without battery Temperature range -20°C to 60°C (-4°F to 140°F) Signal frequency 433 MHz Transmission range 30 m (100 ft) unobstructed Transmission period Approximately every 60 seconds Number of channels 3 Power 1 x UM-3 (AA) 1.5V battery Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. TEMPERATURE To display temperature or select temperature unit: • Press ˚C / ˚F. NOTE Please keep the temperature sensor (adjacent to the adaptor socket) away from electrical devices as heat from these devices will affect the accuracy of indoor temperature readings. If you're in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific. com/service/support.asp For international inquiries, please visit: www2.oregonscientific.com/about/international.asp EU-DECLARATION OF CONFORMITY RESET Press RESET to return to the default settings. to enter. to increase / decrease values of the TYPE ABOUT OREGON SCIENTIFIC will be displayed NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. Press and hold When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste. Rainy MANUALLY SET CLOCK 2 • REMOTE THERMO SENSOR (THN132N) Weather Forecast Area ICON 6. 9. Images shown in this manual may differ from the actual display. SPECIFICATIONS Touch MODE. BAR220: Batteries serve as a back-up power supply. For continuous use of weather icon colour effect and backlight, adaptor must be installed. NOTE The main unit and adaptor should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the main unit and adaptor. MODE: toggle between time / indoor temperature / outdoor temperature displays • MAIN UNIT Make sure the adaptor is not obstructed and is easily accessible to the unit. 1. Only use fresh batteries. Do not mix new and old batteries. Press OR POWER SUPPLY 2 3 • Slide TOGGLE switch to ON/OFF. To manually toggle display: 1. GETTING STARTED 8 9 Do not tamper with the unit’s internal components. This invalidates the warranty. To play demo colour-dance: 1 3 +3 for Eastern time DESCRIPTION The sensor cannot be found. 2 FRONT VIEW +1 for Mountain time +2 for Central time Main unit is searching for sensor(s). A channel has been found. REMOTE SENSOR 0 for Pacific time • PRECAUTIONS • Do not subject the unit to excessive force, shock, dust, temperature or humidity. • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. Hereby, Oregon Scientific, declares that this Artisan weather station (model: BAR220 / BAR220A / BAR220U) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. COUNTRIES RTTE APPROVAL COMPLIED All EU countries,Switzerland CH and Norway N 4 5 6 7 1 8 9 2 3 U 1 2 3 4 5 6 7 8 2010 300102617-00008-10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:6ab303aa-e7f6-11df-8d13-000d93b00e9c Create Date : 2010:11:04 15:54:26Z Metadata Date : 2010:11:04 17:32:18+08:00 Modify Date : 2010:11:04 17:32:18+08:00 Creator Tool : Adobe InDesign CS (3.0) Rendition Class : proof:pdf Derived From Instance ID : 1e104d02-d773-11df-9179-810d4104f7b7 Derived From Document ID : adobe:docid:indd:1e104cff-d773-11df-9179-810d4104f7b7 Document ID : adobe:docid:indd:2187a49d-e9be-11df-8e07-cbcacfba49c5 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Reference Instance ID : uuid:50031432-211e-11df-b8f3-000393caf10c, uuid:2740e7b8-e40e-49b1-8152-b54c81d8de11, uuid:d7d3f1d9-4578-4962-b91d-5827ecf513b7, uuid:50031432-211e-11df-b8f3-000393caf10c, uuid:50031432-211e-11df-b8f3-000393caf10c, uuid:5a4f3814-27b7-11dd-b2c4-000393caf10c Manifest Reference Document ID : uuid:bf9652e5-06b4-4084-9cf9-d5bf0b7a5916, uuid:1ca9b967-9f16-4390-9a46-9b0d45589368, uuid:dcd39943-883f-40db-9267-239e6a747104, uuid:bf9652e5-06b4-4084-9cf9-d5bf0b7a5916, uuid:bf9652e5-06b4-4084-9cf9-d5bf0b7a5916, adobe:docid:indd:cebccfcd-27f3-11dd-ae6a-f2574d2315b3 Format : application/pdf Title : BAR220 M_R1.indd Trapped : False Creator : Adobe InDesign CS (3.0) Producer : Adobe PDF Library 6.0EXIF Metadata provided by EXIF.tools