Knotless Endotendonous Repair System S U RG I C A L T E C H N I QU E The Bridge to Better Care A SIMPLER, KNOTLESS TECHNIQUE FOR FLEXOR TENDON REPAIRS PONTiS is a knotless flexor tendon repair system with the option of a minimally invasive surgical approach. Combined with its simpler procedure, the PONTiS Mulitfilament Stainless Steel (SS) Implant and innovative instrumentation help to provide increased strength of repair and allows for early active motion protocol. For Zone 1 repairs, PONTiS also features an innovative, knotless anchor that enables surgeons to simply reattach the flexor tendon to the distal phalanx. PONTiS SOLUTIONS Standard Flexor Digitorum Profundus (FDP) without Anchors Distal Phalanx Repair with PONTiS Anchor Scan to watch the PONTiS Standard Flexor Digitorum Profundus Surgical Technique animation. 3 STANDARD FLEXOR DIGITORUM PROFUNDUS (FDP) REPAIR 1 FIGURE 1: Using a marking pen make two marks at 1.2cm and 0.6cm. 3 FIGURE 3: Pull the implant through the tendon so the ends are of even length. 5 FIGURE 5: Take the second implant end and cross the tendon so the needle enters the tendon close to where the first needle exited and pull ends tight. 4 2 FIGURE 2: Using the multifilament SS implant make your first pass through the tendon at 1.2cm. 4 FIGURE 4: Take one end and cross the implant over the tendon and place the needle through the tendon at 0.6cm. 6 FIGURE 6: Pass each implant end from its exit point out the cut end of the tendon starting approximately 1mm closer to the cut end. The implant must exit close to the middle of the cut tendon end. 7 FIGURE 7: Remove the needles by cutting the shrink tube close to the needles. 9 FIGURE 9: Dilate the pulley system by pulling the dilation tube back and forth at least 10 times. 11 FIGURE 11: Thread the multifilament SS implant ends through the large diameter of the aglet. Slide tendon passing aglet over the tendon end ensuring the end is fully covered. 8 FIGURE 8: Pass the pulley dilation tube from the wound into the palm. 10 FIGURE 10: Cut the tube at both ends 1cm-2cm distance away from incision. 12 FIGURE 12: Thread implant through the lumen of the pulley dilation tube and place the tip of the aglet in the lumen. 5 STANDARD FDP WITHOUT ANCHORS 13 FIGURE 13: Clamp the multifilament SS implant at the distal end of the pulley dilation tube to hold the aglet tip within the tube at the proximal end. Pull implant ends and tube, as one, distally to feed the tendon through the pulley. 15 FIGURE 15: The distal tendon may be delivered by flexing the distal joints. Repeat stitching steps 1-7. 16b FIGURE 16b: The two proximal implant strands must enter the proximal opening and the two distal implant strands must enter the distal opening. 6 14 FIGURE 14: Remove the pulley dilation tube and aglet. 16a FIGURE 16a: Load the crimp implant into the crimp holder. Pass each multifilament SS implant end through the crimp. 17 FIGURE 17: Release the crimp implant by squeezing the crimp holder. 18 FIGURE 18: Centralize the crimp implant within the tendon by pulling the two multifilament SS implant strands exiting each side of the crimp implant. 20 FIGURE 20: Tighten each implant strand individually prior to using the crimp tool. Assistant will maintain tension as the crimp tool is used to lock the implant. Insert the crimp tool transverse to the tendon. The crimp tool must be completely squeezed until cam-action (bottoming) is felt. 19 FIGURE 19: Place and tie the first epitendonous stitch at the lateral corner of the repair farthest from the surgeon. This will control rotation of the tendon. 21 FIGURE 21: Cut the multifilament SS implant limbs close to the crimp. 22 FIGURE 22: Complete the epitendonous stitch across the palmar surface of the repair by using interrupted stitches. Take the repaired tendon through 5 or 6 excursions to ensure good motion through the pulleys. 7 DISTAL PHALANX REPAIR WITH PONTiS ANCHOR 1 FIGURE 1: Stitch proximal tendon using Steps 1-7 (pages 4-5). Insert Pre-drill to laser line. 3 FIGURE 3: Insert PONTiS anchor to laser line. 5 FIGURE 5: Use a glidding stitch through the distal tendon stump. Pass the multifilament SS implant through the crimp implant. The two proximal implant strands must enter the proximal opening and the two distal implant strands must enter the distal opening. 8 2 FIGURE 2: Insert Tap to laser line. 4 FIGURE 4: Grip the wings of the protective sleeve and pull outward and away from the driver. Remove cap to expose needles. 6 FIGURE 6: Release the crimp implant by squeezing the crimp holder. 7 FIGURE 7: Centralize the crimp implant within the tendon by pulling the two multifilament SS implant strands exiting each side of the crimp. 9 FIGURE 9: Tighten each implant strand individually prior to using the crimp tool. Assistant will maintain tension as the crimp tool is used to lock the implant. Insert the crimp tool transverse to the tendon. The crimp tool must be completely squeezed until cam-action (bottoming) is felt. 8 FIGURE 8: Place and tie the first epitendonous stitch at the lateral corner of the repair farthest from the surgeon. This will control rotation of the tendon. 10 FIGURE 10: Cut the multifilament SS implant limbs close to the crimp. 11 FIGURE 11: Complete the epitendonous stitch across the palmar surface of the repair by using interrupted stitches. Take the repaired tendon through 5 or 6 excursions to ensure good motion through the pulleys. 9
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : No Page Count : 9 XMP Toolkit : XMP Core 5.1.2 Modify Date : 2013:02:22 12:13:23-08:00 Create Date : 2012:08:27 19:45:20Z Thumbnail Image : (Binary data 9557 bytes, use -b option to extract) Thumbnail Width : 200 Thumbnail Height : 256 Thumbnail Format : JPEG Metadata Date : 2013:02:22 12:13:23-08:00 Creator Tool : Adobe Illustrator CS4 N Pages : 1 Swatch Group Name : Default Swatch Group Swatch Group Type : 0 Has Visible Transparency : True Plate Names : Cyan, Magenta, Yellow, Black Max Page Size W : 8.500000 Max Page Size H : 11.000000 Max Page Size Unit : Inches Has Visible Overprint : True Font Type : TrueType, TrueType, Unknown, Unknown Font File Name : HelveticaNeue.dfont, HelveticaNeue.dfont, MyriadPro-Regular.otf, MyriadPro-Regular.otf Font Name : HelveticaNeue-Light, HelveticaNeue-Medium, AGaramond-Regular, HelveticaNeue-Condensed Font Family : Helvetica Neue, Helvetica Neue, AGaramond Regular, HelveticaNeue Condensed Font Version : 7.0d27e1, 7.0d27e1, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168 Font Face : Light, Medium, Regular, Condensed Font Composite : False, False, False, False Instance ID : uuid:31d4869b-100f-4f9a-b7ce-631459cf0e40 Document ID : uuid:c7f1b2e4-8b48-aa49-9e61-dd1ec5611fd3 Rendition Class : proof:pdf Format : application/pdf Title : Print Creator : richtimmons Producer : Mac OS X 10.7.4 Quartz PDFContext PDF Version : 1.4 Author : richtimmonsEXIF Metadata provided by EXIF.tools