REF 03-07
Monogram
®
REFRIGERATOR
MULLION CONDENSATION
March 2007
GE Consumer Products
General Electric Company
Louisville, Kentucky 40225
WR49X10081 Installation Instructions
This thermostat is designed for use on the Monogram Side-by-side
and Bottom-Freezer refrigerators to reduce mullion condensation.
Tools Required:
• Wire Cutters/
Wire Crimpers
Parts Included:
• 3 connectors (WR2X4330D)
2 required, 1 extra
Models:
All Monogram Side by Side and Bottom Freezer models manufactured after 2001 • Measuring Tape
• Step Ladder • Thermostat with clip
(36426-00)
• Set of instructions
• 3 wire clips (2594)
GE CONFIDENTIAL AND PROPRIETARY INFORMATION–NOT FOR PUBLIC DISCLOSURE
STEP 1 RAISE GRILLE PANEL,
DISCONNECT POWER
· Lift-up grille panel.
· Unplug power cord from wall outlet.
· Remove electrical wiring cover.
WARNING: TO PREVENT ELECTRICAL SHOCK,
DISCONNECT ELECTRICAL POWER SUPPLY TO THE
REFRIGERATOR BEFORE INSTALLING THE THERMOSTAT.
DO NOT OPERATE THE REFRIGERATOR UNTIL INSTALLA-
TION IS COMPLETED.
SIDE-BY-SIDE
MODELS
GO TO STEP 2
BOTTOM-FREEZER
MODELS
GO TO STEP 2A
ON OPPOSITE
SIDE
STEP 2 MOUNT THERMOSTAT ON SIDE-BY-SIDE MODELS
· Mount the thermostat on the compressor discharge
tube, 4" from the compressor. Note: To ensure a
successful installation, use a tape to measure the
distance along the tube. See illustration.
· Cut the pink wire (from pin 5 on the J2 connector) to
the condenser fan motor, approximately 3" from the J2
harness connector.
· Connect the thermostat wire ends to the cut ends of
the condenser fan pink wire (from pin 5 on the J2
connector), using the supplied connectors.
· Dress the wiring to prevent interference with the
condenser fan or the compressor case.
· Plug power cord into wall outlet.
· Close grille panel.
Completely WIPE DRY any condensation from the
mullion and gasket. Note: Allow approximately 20 minutes for the condenser fan
to turn on after the compressor starts.
This Bulletin Replaces REF 14-04
Service Bulletin
STEP 2A
MOUNT THERMOSTAT ON BOTTOM FREEZER MODELS
· Mount the thermostat on the compressor discharge
tube, 3" from the compressor. Note: To insure a
successful installation, use a tape to measure the
distance along the tube. See illustration.
· Cut the pink wire (from pin 5 on the J2 connector) to
the condenser fan motor, approximately 3" from the
J2 harness connector.
· Connect the thermostat wire ends to the cut ends
of the condenser fan pink wire (from pin 5 on the
J2 connector), using the supplied connectors.
· Dress the wiring to prevent interference with the
condenser fan, the compressor case, or door closure
mechanism.
· Plug power cord into wall outlet.
· Close grille panel.
Completely WIPE DRY any condensation from the
mullion and gasket. Note: Allow approximately 20 minutes for the condenser fan
to turn on after the compressor starts.
Dress Wires to
A
void Contac
t