Denotes handhole location
12L
23T
3Y 4
APPLICATIONS
Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not
exceeding maximum allowable loading of the specified pole in its installed geographic location
CONSTRUCTION
SHAFT: One-piece straight aluminum with round cross section, 6061-T6
BASE COVER: Two-piece cast aluminum base covers available
POLE CAP: Cap or decorative finials available for side mounted luminaires. Open top or tenons provided for
post top mounted luminaires.
HAND HOLE: Opening provided with cast aluminum frame reinforcement.
FINISH
Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness
Decorative finish coat available in twelve standard colors; Custom colors available; RAL number preferable
RSA-B-DBE-S
SERIES POLES
ROUND STRAIGHT ALUMINUM
Cat.#
Approvals
Job Type
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-DBE-S POLES-SPEC 7/16
TENONS & POLE CAPS
1 Specify option location using logic found on page 2 (Option Orientation)
2 Not available with 3” diameter roles.
Denotes handhole location
1
2L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23
T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
MOUNTING ORIENTATION
ORDERING EXAMPLE:
ACCESSORIES- Order Separately
Catalog Number Description
VM2SXX 2nd mode vibration damper
SERIES
RSA-B-
DBE-S
Round Straight
Aluminum
Direct Burial
Style Beacon
RSA-B-DBE-S 16 40 A/B/C 2L BBTB3 VM2
MOUNTING
1
Single arm mount
2
Two fixtures at
180˚
2L2
Two fixtures at 90˚
3T2
Three fixtures
at 90˚
3Y2
Three fixtures at
120˚
42
Four fixtures at 90˚
OT
Open top (no
drilling)
BAL Ball Finial
ACR Acorn Finial
TN32Tenon 3 x 3
TN42Tenon 3 x 4
TN52Tenon 4 x 5
TN82Tenon 4 x 8
FINISH
BBT Basic Black Textured
BMT Black Matte Textured
BZT Bronze Textured
DBT Dark Bronze Textured
DPS Dark Platinum Smooth
GNT Green Textured
GYS Gray Smooth
MBT Metallic Bronze Textured
MST Metallic Silver Textured
MTT Metallic Titanium Textured
OWI Old World Iron
WHT White Textured
CC Custom Color- RAL Color#
DRILL
PATTERN
B1
CRUZER
B3 VP-L
B4 VP-S
HEIGHT
Reference page 2
Ordering matrix
SHAFT
Reference page 2
Ordering matrix
THICKNESS
Reference
page 2
Ordering matrix
OPTIONS
GFI1,2
20 Amp GFCI
Receptacle and
Cover
EHH1,2
Extra Handhole
C051
.5” Coupling
C071
.75” Coupling
C201
2” Coupling
VM2 2nd mode
vibration
damper
Pole Shaft
Pole Height
Hand Hole
Foundation
18”
18”
6”
Anti-Rotation Device
*Local civil engineer should be consulted
for proper foundation design
8’ - 16’
Wiring Access
Round Steel Pole
Standard hand
hole frame
Adapter plate
Gasket
20 AMP GFCI
Wet Locations
In-use Cover
ORDERING INFORMATION Cont.
For more information about pole vibration and vibration dampers, please consult http://cdn.beaconproducts.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
Follow the logic below when ordering location specific options. For each option, include its orientation (in degrees)
and its height (in feet). Example: Option C07 should be ordered as: RSA-B-DBE-S-16-40A-TN3-BBT-CO5-0-10.
(.5” coupling on the handhole/arm side of pole, 15 feet up from the pole base) 1’ spacing required between option.
Consult factory for other configurations.
OPTION ORIENTATION
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-DBE-S POLES-SPEC 7/16
EHH - EXTRA
HANDHOLE
C05 - C07 - C20 -
COUPLING
VM2 - VIBRATION
DAMPER 2ND MODE
VM2SXX - VIBRATION
DAMPER 2ND MODE
Provision for Grounding
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
1/2” - 14 NPSM Threads
3/4” - 14 NPSM Threads
2” -11.5 NPSM Threads
Factory installed, internal
damper designed to alter
pole resonance to reduce
movement and material
fatigue caused by 2nd mode
vibration.
Field installed, internal
damper designed to alter
pole resonance to reduce
movement and mate-
rial fatigue caused by 2nd
mode vibration.
VM2S08 – 8'
VM2S12 – 12'
VM2S16 – 16'
VM2S20 – 20'
VM2S24 – 24'
GFI – 20 AMP GFCI
RECEPTACLE & COVER
VIBRATION DAMPER
2ND MODE
Catalog Number
Pole Height Nominal
Shaft Dimensions
Wall
Thickness
Pole weight
(lbs)
Feet Meters
RSA-B-DBE-S-08-30-A 08 2.4 3" Round 0.125" 15
RSA-B-DBE-S-10-30-A 10 3.0 3" Round 0.125" 18
RSA-B-DBE-S-12-30-A 12 3.7 3" Round 0.125" 22
RSA-B-DBE-S-14-30-A 14 4.3 3" Round 0.125" 25
RSA-B-DBE-S-08-30-C 08 2.4 3" Round .25" 28
RSA-B-DBE-S-10-30-C 10 3.0 3" Round .25" 34
RSA-B-DBE-S-12-30-C 12 3.7 3" Round .25" 41
RSA-B-DBE-S-14-30-C 14 4.3 3" Round .25" 48
RSA-B-DBE-S-08-40-A 08 2.4 4" Round 0.125" 20
RSA-B-DBE-S-10-40-A 10 3.0 4" Round 0.125" 24
RSA-B-DBE-S-12-40-A 12 3.7 4" Round 0.125" 29
RSA-B-DBE-S-14-40-A 14 4.3 4" Round 0.125" 34
RSA-B-DBE-S-16-40-A 16 4.9 4" Round 0.125" 39
RSA-B-DBE-S-08-40-B 08 2.4 4" Round 0.188" 29
RSA-B-DBE-S-10-40-B 10 3.0 4" Round 0.188" 36
RSA-B-DBE-S-12-40-B 12 3.7 4" Round 0.188" 43
RSA-B-DBE-S-14-40-B 14 4.3 4" Round 0.188" 50
RSA-B-DBE-S-16-40-B 16 4.9 4" Round 0.188" 57
RSA-B-DBE-S-08-40-C 08 2.4 4" Round 0.25" 37
RSA-B-DBE-S-10-40-C 10 3.0 4" Round 0.25" 47
RSA-B-DBE-S-12-40-C 12 3.7 4" Round 0.25" 56
RSA-B-DBE-S-14-40-C 14 4.3 4" Round 0.25" 65
RSA-B-DBE-S-16-40-C 16 4.9 4" Round 0.25" 74
RSA-B-DBE-S-08-50-B 08 2.4 5" Round 0.188" 36
RSA-B-DBE-S-10-50-B 10 3.0 5" Round 0.188" 45
RSA-B-DBE-S-12-50-B 12 3.7 5" Round 0.188" 54
RSA-B-DBE-S-14-50-B 14 4.3 5" Round 0.188" 63
RSA-B-DBE-S-16-50-B 16 4.9 5" Round 0.188" 71
RSA-B-DBE-S-10-60-A 10 3.0 6" Round 0.125" 37
RSA-B-DBE-S-12-60-A 12 3.7 6" Round 0.125" 44
RSA-B-DBE-S-14-60-A 14 4.3 6" Round 0.125" 51
RSA-B-DBE-S-16-60-A 16 4.9 6" Round 0.125" 58
ASCE7-05 WIND MAP FLORIDA REGION WIND MAP
180
180
170
170
160
160
150
150
140
140
140
150
140
150
130 120 115
115
120
130
Florida region wind map above is based upon 3-second
gust winds and the 2014 Florida Building Code
HAWAII – 105 mph
PUERTO RICO – 145 mph
NOTES:
Values are based on 50 year mean recurrence interval 30
above grade.
Hawaii has an 105 mph wind velocity.
Puerto Rico has a 125 mph wind velocity.
Caution must be exercised in determining wind velocities
in special wind areas such as:
Mountainous Regions
Areas surrounding the Great Lakes or other large bodies
of water or open land.
Areas subject to extreme wind conditions, such as
hurricanes, typhoons, cyclones, and tornadoes.
Areas adjacent to airports.
Any specific area with a known or suspected abnormally
high intermittent wind condition caused by geography,
adjacent structures, or other specific local conditions
that may not be recorded in National Weather Service
records.
Allowable pole EPA for jobsite wind conditions must be
equal to or greater than fixture EPA. Responsibility lies with
the specifier for correct pole selection based on AASHTO
wind map and job location.
The Wind Map is intended only as a general guide. Always
consult local authorities to determine maximum wind
velocities, gusting and unique wind conditions for each
specific application.
CAUTION: Wind speeds and listed EPAs are for ground
mounted installations. Poles mounted on structures (such
as bridges and buildings) must consider vibration and
coefficient of height factors beyond this general guide.
Consult AASHTO standards.
Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or
Tornadoes expose poles to flying debris, wind shear, and
other unpredictable aerodynamic forces not indicated by
the wind velocity ratings.
Pole Strength Limited Warranty: Standard, unmodified Kim
lighting Poles installed as recommended, undamaged by
corrosion, or lack of maintenance, shall withstand steady
wind conditions as provided on page 2 (Allowable Pole
EPA). Installation of poles without luminaires, or attachment
of any unauthorized accessories to poles shall void this
warranty.
85
90
90
100
110
120
130
130
140
140
140
150
150
140
130
120
110
100
90
Special Wind Region
(Consult Local Authorities)
90
Wind Map
United Sta
tes and Canada
Florida Building Code 2014 EPA Load Rating - 3 second gust wind speeds
Catalog Number 115 120 130 140 150 160 170 180
RSA-B-DBE-S-08-30-A 11.0 10.1 8.6 7.4 6.3 5.5 4.8 4.2
RSA-B-DBE-S-10-30-A 8.1 7.4 6.3 5.3 4.5 3.8 3.3 2.8
RSA-B-DBE-S-12-30-A 6.1 5.5 4.6 3.8 3.2 2.6 2.2 1.8
RSA-B-DBE-S-14-30-A 4.6 4.2 3.4 2.7 2.2 1.7 1.3 1.0
RSA-B-DBE-S-08-30-C 20.2 18.7 16.0 13.9 12.1 10.6 9.3 8.2
RSA-B-DBE-S-10-30-C 15.3 14.1 12.1 10.4 9.0 7.8 6.8 6.0
RSA-B-DBE-S-12-30-C 11.9 11.0 9.3 8.0 6.9 5.9 5.1 4.4
RSA-B-DBE-S-14-30-C 9.4 8.7 7.3 6.2 5.3 4.5 3.8 3.2
RSA-B-DBE-S-08-40-A 21.2 19.6 16.7 14.4 12.4 10.8 10.1 9.0
RSA-B-DBE-S-10-40-A 16.0 14.7 12.5 10.7 9.2 7.9 7.6 6.7
RSA-B-DBE-S-12-40-A 12.5 11.4 9.6 8.1 6.9 5.8 5.6 5.1
RSA-B-DBE-S-14-40-A 9.8 8.9 7.4 6.2 5.1 4.2 4.0 3.9
RSA-B-DBE-S-16-40-A 7.7 7.0 5.7 4.6 3.7 2.9 2.5 2.0
RSA-B-DBE-S-08-40-B 25.0 25.0 24.6 21.3 18.5 16.2 14.9 13.3
RSA-B-DBE-S-10-40-B 23.8 21.9 18.7 16.1 14.0 12.1 11.4 10.1
RSA-B-DBE-S-12-40-B 18.8 17.3 14.7 12.6 10.8 9.3 9.0 7.9
RSA-B-DBE-S-14-40-B 15.1 13.9 11.7 9.9 8.5 7.2 6.7 6.3
RSA-B-DBE-S-16-40-B 12.2 11.1 9.3 7.8 6.5 5.5 5.2 5.0
RSA-B-DBE-S-08-40-C 25.0 25.0 25.0 25.0 23.9 21.0 19.2 17.1
RSA-B-DBE-S-10-40-C 25.0 25.0 24.3 21.0 18.2 15.9 14.8 13.2
RSA-B-DBE-S-12-40-C 24.4 22.5 19.2 16.5 14.3 12.4 11.8 10.4
RSA-B-DBE-S-14-40-C 19.8 18.3 15.6 13.3 11.4 9.8 9.6 8.4
RSA-B-DBE-S-16-40-C 16.2 14.9 12.6 10.7 9.1 7.7 7.1 6.8
RSA-B-DBE-S-08-50-B 25.0 25.0 25.0 25.0 25.0 25.0 24.4 21.8
RSA-B-DBE-S-10-50-B 25.0 25.0 25.0 25.0 24.3 21.4 18.9 16.8
RSA-B-DBE-S-12-50-B 25.0 25.0 24.9 22.5 19.6 17.2 15.1 13.4
RSA-B-DBE-S-14-50-B 25.0 23.8 20.2 18.6 16.1 14.1 12.4 10.9
RSA-B-DBE-S-16-50-B 21.3 19.5 16.4 15.4 13.3 11.6 10.1 8.8
RSA-B-DBE-S-10060-A 25.0 25.0 25.0 25.0 24.4 21.4 18.9 16.7
RSA-B-DBE-S-12060-A 25.0 25.0 25.0 22.6 19.6 17.1 15.0 13.3
RSA-B-DBE-S-14060-A 25.0 25.0 21.6 18.6 16.1 14.0 12.2 10.7
RSA-B-DBE-S-16060-A 22.9 21.1 17.9 15.3 13.2 11.4 9.9 8.6
ASCE 7-05 wind map EPA Load Rating - 3 second gust wind speeds
Catalog Number 85 90 100 105 110 120 130 140 150 160
RSA-B-DBE-S-08-30-A 11.2 10.1 8.2 7.4 6.7 5.5 4.6 3.9 3.5 3.2
RSA-B-DBE-S-10-30-A 8.3 7.4 5.9 5.3 4.8 3.9 3.1 2.5 2.3 2.1
RSA-B-DBE-S-12-30-A 6.3 5.6 4.4 3.9 3.4 2.7 2.1 1.6 1.4 1.2
RSA-B-DBE-S-14-30-A 4.8 4.2 3.2 2.8 2.4 1.8 1.3 0.9 0.7 0.5
RSA-B-DBE-S-08-30-C 20.6 18.5 15.1 13.7 12.5 10.5 8.9 7.6 7.0 6.5
RSA-B-DBE-S-10-30-C 15.6 14.0 11.4 10.3 9.4 7.8 6.5 5.5 5.1 4.6
RSA-B-DBE-S-12-30-C 12.2 10.9 8.8 8.0 7.2 5.9 4.9 4.0 3.7 3.3
RSA-B-DBE-S-14-30-C 9.7 8.7 6.9 6.2 5.6 4.5 3.6 2.9 2.6 2.3
RSA-B-DBE-S-08-40-A 21.8 19.5 15.8 14.3 13.0 10.9 9.3 8.0 7.4 6.9
RSA-B-DBE-S-10-40-A 16.5 14.8 11.9 10.7 9.7 8.0 6.8 5.9 5.4 5.1
RSA-B-DBE-S-12-40-A 12.9 11.5 9.2 8.2 7.4 6.0 5.1 4.3 4.0 3.7
RSA-B-DBE-S-14-40-A 10.3 9.1 7.1 6.3 5.6 4.5 3.7 3.2 2.9 2.7
RSA-B-DBE-S-16-40-A 8.2 7.2 5.5 4.8 4.3 3.3 2.7 2.2 2.0 1.8
RSA-B-DBE-S-08-40-B 25.0 25.0 23.2 21.1 19.2 16.1 13.8 11.9 11.1 10.4
RSA-B-DBE-S-10-40-B 24.3 21.8 17.7 16.0 14.5 12.1 10.4 8.9 8.3 7.8
RSA-B-DBE-S-12-40-B 19.2 17.2 13.9 12.5 11.3 9.4 8.0 6.9 6.4 5.9
RSA-B-DBE-S-14-40-B 15.5 13.8 11.1 10.0 9.0 7.3 6.2 5.3 4.9 4.6
RSA-B-DBE-S-16-40-B 12.7 11.3 8.9 8.0 7.1 5.7 4.8 4.1 3.8 3.5
RSA-B-DBE-S-08-40-C 25.0 25.0 25.0 25.0 24.7 20.8 17.8 15.4 14.4 13.4
RSA-B-DBE-S-10-40-C 25.0 25.0 22.9 20.8 18.9 15.9 13.6 11.7 10.9 10.2
RSA-B-DBE-S-12-40-C 24.9 22.3 18.2 16.4 14.9 12.5 10.6 9.2 8.5 8.0
RSA-B-DBE-S-14-40-C 20.3 18.2 14.7 13.3 12.0 9.9 8.4 7.3 6.7 6.3
RSA-B-DBE-S-16-40-C 16.8 15.0 12.0 10.8 9.7 8.0 6.7 5.8 5.3 5.0
RSA-B-DBE-S-08-50-B 25.0 25.0 25.0 25.0 25.0 25.0 23.2 20.1 18.7 17.5
RSA-B-DBE-S-10-50-B 25.0 25.0 25.0 25.0 24.8 21.0 17.9 15.5 14.5 13.5
RSA-B-DBE-S-12-50-B 25.0 25.0 23.8 21.7 19.9 16.8 14.3 12.4 11.5 10.8
RSA-B-DBE-S-14-50-B 25.0 23.8 19.4 17.7 16.2 13.7 11.6 10.0 9.3 8.7
RSA-B-DBE-S-16-50-B 22.2 19.8 16.1 14.6 13.4 11.2 9.6 8.2 7.6 7.1
RSA-B-DBE-S-10060-A 25.0 25.0 25.0 25.0 25.0 21.4 18.2 15.8 14.7 13.7
RSA-B-DBE-S-12060-A 25.0 25.0 24.4 22.2 20.3 17.1 14.6 12.6 11.8 11.0
RSA-B-DBE-S-14060-A 25.0 24.4 20.0 18.2 16.6 14.0 12.0 10.3 9.6 8.9
RSA-B-DBE-S-16060-A 22.7 20.4 16.6 15.1 13.8 11.6 9.9 8.5 7.9 7.3
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-DBE-S POLES-SPEC 7/16
Wind-speed Website disclaimer:
Hubbell Lighting has no connection to the linked website and makes no representations as to its accuracy. While the information presented on this third-party website provides a useful
starting point for analyzing wind conditions, Hubbell Lighting has not verified any of the information on this third party website and assumes no responsibility or liability for its accuracy.
The material presented in the windspeed website should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability
and applicability by engineers or other licensed professionals. Hubbell Lighting Inc. does not intend that the use of this information replace the sound judgment of such competent
professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results
of the windspeed report provided by this website. Users of the information from this third party website assume all liability arising from such use. Use of the output of these referenced
websites do not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude
location in the windspeed report. http://windspeed.atcouncil.org
NOTES
Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs.
The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide and
cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application
Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for
correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty
Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this
general guide; Consult local and federal standards
Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Hubbell Lighting’s Pole Vibration
Application Guide for environmental risk factors and design considerations. http://cdn.beaconproducts.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-DBE-S POLES-SPEC 7/16

Navigation menu