Application
The SE Series offers bright and even LED illumination in an attractive die-cast aluminum
housing. Features include UL listing for 2 hour runtime, AC or Emergency operation with
optional Spectron® self-test/self-diagnostic circuitry. Special Wording (SW) option also allows
for customization of the stencil field to convey important information. Housing designed for
quick and easy installation with low energy consumption. Damp location listed. Includes a
Vandal/Tamper Resistant (VTR) option. The -VTR option includes a polycarbonate faceshield
and tamper resistant screws.
Construction
Housing, exit face and matching canopy constructed of high-strength die-cast aluminum.
Sign finish is textured white, white with brushed aluminum face, black, or black with brushed
aluminum face. Diffuser finish is color-matched silk-screened coating which provides optimized
LED light output. Exit face design in single or double face with red or green letters and break-out
chevrons. Exit stencil with 6" letters and ¾" stroke.
Installation
Universal mounting (wall, ceiling, end) to standard 3½" or 4" octagon or square electrical
box by use of easily removed, template configured knockouts. Cast aluminum canopy and
universal mounting plate included. All mounting hardware is fully concealed.
Illumination
Exit face illumination is provided by energy savings, long life red or green LEDs. Exceeds UL
924 requirements for brightness and uniformity.
Compliances
UL 924 Listed (Meets 1998 brightness and uniformity requirements)
UL Damp Location Listed
NFPA 70
NFPA 101
Warranty
Unit and electronics: 5 years full.
SE Series
Cast Aluminum LED Exit Sign
ORDERING GUIDE
Catalog Number
Comments Type
FEATURES
DIE-CAST LED Exit
ACCESSORIES
(order separately)
SER-E
Kit converts AC red letter models to emergency operation
SEG-E
Kit converts AC green letter models to emergency operation
PMCW 12 1/2" Pendant mounting kit (white)
PMCB 12 1/2" Pendant mounting kit (black)
WGLX Wire guard (Wall mount)
WGLXC Wire guard (Ceiling mount)
WGLXE Wire guard (End mount)
VRS3 Vandal resistant shield
See Page 3 for Special
Wording Options
SE S R W E I -FM -SW48
S - Single
D - Double
W - White
B - Black
BN - Black with
Brushed Face
WN - White with
Brushed Face
Series Faces
Housing Finish
Operation
R - Red
G - Green
Blank - AC Only
E - Emergency
Special Wording Options
Self-Diagnostics
-2C 2-circuit operation (2, 5)
-FAP Fire alarm panel
interface (3, 5, 6)
-FM Flasher module (1, 6)
-AF Audible/Flasher module (1, 6)
-DC Remote DC operation (2, 4, 5)
-24K 220-240VAC, 60 Hz. operation
-VTR Vandal/tamper resistant
option (7)
Blank None
I
Spectron® self-testing/
self-diagnostic
electronics
Letter
Color Options
(1) For use with emergency models only.
(2) For use with AC models only.
(3) Operates with 24-volt AC or DC fire alarm panels.
(4) For emergency illumination of sign from remote 6-24 VDC power sources.
(5) -DC option may not be specified with -2C or -FAP options.
(6) -AF, -FM and -FAP options may not be specified together.
(7) Provides polycarbonate face shield and tamper-proof screws.
NOTES
Electronics
Available with AC, emergency and Spectron® self-test/self-
diagnostic electronics option. Emergency and self-diagnostic
models equipped with isolation transformer and fully automatic
constant current solid state charger with sealed maintenance-
free nickel-cadmium battery. All emergency models with 2-hour
minimum run-time. All components mounted inside housing.
Includes test switch and AC-on indicator. Transient/surge
protection, low voltage disconnect and AC lock-out features
included. Battery re-charge within UL time standards. Includes
pre-stripped AC input pigtail leads.
DIMENSIONS
SPECIFICATIONS
SE Series
Cast Aluminum LED Exit Sign
15/8"
(4 cm)
91/8"
(23 cm)
10"
(25.5 cm)
113/4" (30 cm)
125/8" (32 cm)
120VAC 277VAC
Red AC Only Models: 2.64 watts 2.70 watts
Green AC Only Models: 2.24 watts 2.24 watts
Red Emergency Models: 3.81 watts 3.80 watts
Green Emergency Models: 3.50 watts 3.50 watts
* Wattage figures include LED lamps, transformer and electronics power
requirements. LED lamp assemblies (red or green) consume less than 1 watt.
Push-in quick-connect
AC terminals
Isolated,
grounded
120/277VAC
transformer
Charger/transfer module
Universal wall mounting
KO pattern
Wiring
channel
Push-out
chevron-style
directional
indicators
Sealed
nickel-cadmium
battery
LED
illumination
strip
Power Factor, Average: .8 (lagging)
Battery Type: Maintenance-free sealed nickel cadmium battery
AC Input: 120/277VAC, 60 Hz. (all models)
Operating Temperature Range: 0°C to 40°C (32°F to 104°F)
Power Consumption
STANDARD SIGNS
SW65 (Makhraj Arabic) SW10 SW13 SW40 SW47
SW5 SW101 SW7 SW97 SW22
SW31 SW45 SW37 SW98 SW9
SW30 SW69 SW48 SW73 SW4
SE Series
Cast Aluminum LED Exit Sign
Dual-Lite's cast-aluminum SE Series exit signs feature an option for custom or standard special-wording. The images below
represent a sample of standard special-worded signs available. A comprehensive list of all standard special-wording signs
is shown on the next page. Because the artwork and silk-screening for these signs were previously developed, pricing for
these standard special-worded signs do not incur a setup charge. If your special-worded requirements do not show up on
this list, please contact the factory to request your custom special-worded sign. Custom special-worded signs will incur a
one time setup charge for each development.
Dual-Lite • www.dual-lite.com
A Hubbell Lighting, Inc. brand with representatives’ offices in principal cities throughout North America.
Copyright© Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A. 0601835 C 12/09
SE Series
Cast Aluminum LED Exit Sign
STANDARD SPECIAL WORDING SIGNS
Category
Special
Wording
Number
Description
EXIT
SW 1TO EXIT
SW 2NOT AN EXIT
SW 22 EXIT WITH
WHEELCHAIR SYMBOL
SW 37 NO EXIT
SW 42 EMERGENCY EXIT ONLY
SW 63 WHEELCHAIR
SYMBOL/EXIT
SW 67 EMERGENCY EXIT
SW 70 FIRE EXIT ONLY
SW 73 TO FIRE ESCAPE
AREAS/ALERTS
SW 5DARKROOM IN USE
SW 9ON AIR
SW 27 QUIET
SW 29 PERFORMANCE IN
PROGRESS
SW 44 IMAGE ACQUISITION
SW 52 STUDIO IN USE
SW 55 BATTERY CHARGING IN
PROCESS
SW 61 UNCLEARED VISITORS
SW 68 STAND BY ON AIR
SW 80 TV STUDIO IN USE
SW 85 JURY IN SESSION
SW 88 DARKROOM IN USE/DO
NOT ENTER
SW 100 CLASSIFIED/BRIEFING
SW 102 UNCLEAR/VISITOR IN
AREA
SW 111 MEETING IN
PROGRESS
SW 115 RECORDING
SW 121 QUIET PLEASE/SLEEP
STUDY IN PROGRESS
SW 128 INTERVIEW IN
PROGRESS
SW 129 SIMULATOR/IN USE
SW 131 RANGE/IN USE
DO NOT ENTER
SW 3IN USE
SW 7DO NOT ENTER
SW 8TEST IN PROGRESS
SW 30 ROOM IN USE
SW 74 IN USE/DO NOT ENTER
SW 86 DO NOT USE
SW 90 ROOM IN USE/
DO NOT ENTER
SW 95 DO NOT ENTER/
TESTING IN PROGRESS
SW 101 DO NOT DISTURB
SW 104 DO NOT ENTER/
TRAINING IN PROGRESS
SW 110 SECURE
Category
Special
Wording
Number
Description
EVACUATION
SW 10 AREA OF REFUGE
SW 11 AREA OF REFUGE WITH
WHEELCHAIR SYMBOL
SW 12 AREA OF RESCUE
ASSISTANCE
SW 13
AREA OF RESCUE
ASSISTANCE WITH
WHEELCHAIR
SYMBOL
SW 14 ELEVATOR
SW 24 CAUTION STAIRS
SW 25 NOT AN AREA OF
REFUGE
SW 40 AREA OF RESCUE
SW 48 STAIRS
SW 79 TO AREA OF RESCUE
ASSISTANCE
SW 97 EMERGENCY
ASSISTANCE
SW 117 TO AREA OF REFUGE
SW 122 AREA OF REFUGE
ASSISTANCE
SW 123 UP
SW 124 DOWN
SW 132 RED CROSS (SYMBOL
ONLY)
DANGER/
ALERTS
SW 6CAUTION
SW 47 DANGER
LABORATORY
SW 4X-RAY IN USE
SW 20 WARNING LASER ON
SW 21 BEAM ON
SW 23 CAT SCAN IN USE
SW 26 MRI ROOM IN USE
SW 28 MRI IN USE
SW 31 LASER IN USE
SW 33 LASER ON DO NOT
ENTER
SW 34 MAGNET ON
SW 36 UV LIGHTING IN USE
SW 38 CLOSE HOODS
SW 39 RADIATION ON
SW 43 DANGER BIO HAZARD
IN USE
SW 45 MAGNET IN USE
SW 46 LASER LAB IN USE
SW 49 X-RAY ON
SW 51 CAUTION X-RAY
SW 53 BEAM ON DO NOT
ENTER
SW 56 FIRE
SW 57 CT IN USE
SW 58 OPEN LASER
Category
Special
Wording
Number
Description
LABORATORY
(continued)
SW 62 RADIATION IN USE
SW 71 X-RAY
SW 72 X-RAY OFF
SW 83 MAGNET AT FIELD
SW 87 BEAM IN USE
SW 89 CRYOSTAT MAGNET
IN USE
SW 105 CT SCAN/IN USE
SW 107 DANGER
(SEE TABLE-LASERS)
SW 112 X-RAY IN USE/
DO NOT ENTER
SW 113 MAGNET/RAMPED
SW 116 SCANNER IN USE
SW 120 UV/RADIATION
SW 125 NO ENTRY FUEL CELL
WORK IN PROGRESS
SW 127 RADIATION
ON/OFF
SW 50 GENERATOR ON
SW 75 FAN OFF
SW 82 EMERGENCY POWER
ON
SW 84 CITY WATER BACKUP
ON
SW 106 READY ON
SW 108 READY
PEDESTRIANS/
CROSSING
SW 35 PEDESTRIAN ONLY
SW 78 CAUTION WATCH FOR
PEDESTRIANS
RESTROOMS/
FACILITIES
SW 98 NO SMOKING
SW 15 RESTROOMS
SW 16 MEN
SW 17 MEN WITH SYMBOL
SW 18 WOMEN
SW 19 WOMEN WITH
SYMBOL
SW 54 PHONE
SW 91 DECORATIVE CROSS
SYMBOL
SW 92 NON SMOKING
SW 118 HANDICAPPED
( SYMBOL ONLY)
INTERNATIONAL
EXIT
SW 32 EXIT/SALIDA
SW 41 ARABIC/EXIT
SW 64 ARABIC/EXIT
SW 65 MAKHRAJ ARABIC/
EXIT
SW 66 ARABIC/EXIT
SW 69 SALIDA