St814
2017-06-22
: Pdf St814 st814 spec products columbia
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
ST814 1' × 4' Shallow Specification Troffer / 2-Lamp T5, T5HO, 2 or 3-Lamp T8 PROJECT INFORMATION Project Name Type Catalog No. Date FLANGED FEATURES FEATURES Four adjustable Uni-Lugs for quick easy installation. Optional plaster frames available for individual or row mounting. Fixture end flanges are removable for row mounting. Joiner cables are included. • Optical performance designed for T8 and T5 lamp technology • Mechanical light seal • Mitered corners on door present a clean uninterrupted appearance • Spring loaded latches optional • Rolled fixture edges reduce risk of injury during fixture handling and installation • Integral T-Bar clips quickly secure fixture to grid system without the need for time consuming loose parts • Snap-on ballast covers can be removed with lamps installed • Corner hinging for easy insertion and removal of door frame from either side • Optional flush or regressed aluminum shielding frames available with positive action or spring loaded latches • Housing ends secured by unique corner interlock and screws HOUSING BALLASTS 100% acrylic prismatic, extruded and rollembossed, diagonally oriented female prisms, unless otherwise specified. ELECTRICAL All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. Heavy gauge steel. Die formed for extra rigidity. Designed for installation in standard inverted tee grid ceilings. Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant. Standard class "P," thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard. ORDERING INFORMATION ST8 14 SHIELDING CERTIFICATION EXAMPLE ST814-232G-FSA12-EU-F0735-C488 – – MODEL NO. OF LAMPS CEILING TYPE ST8 Shallow Specification Troffer 1 One 2 Two 3 Three (T8 only) G Inverted T-Bar (Std.) F Overlap Flange (41/2" overall fixture height) SIZE LAMP TYPE 14 1' × 4' 28 4', T5: 28 Watt (2-Lamp only) 32 4', T8: 32, 30, 28 or 25 Watt 54 4', T5HO: 54 or 51 Watt (2-Lamp Only) Page 1/2 Rev. 03/15/17 FINISH All metal parts are processed with a five phase phosphate bonding treatment. Grid units are pre-painted with high polyester baked white enamel, 86% reflective. Flanged units are painted after fabrication with a polyester powder coat, reflectance of 90%. – SHIELDING A12 Pattern 12 Acrylic 0.100" Nominal (Standard) A12.125 Pattern 12 Acrylic 0.125" Nominal A19 Pattern 19 Acrylic 0.15" Male Prism PC1 Silver Parabolic Louver DOOR STYLE 1/2" × 1/2" × 1/2" FS Flush Steel PC2 Silver Parabolic Louver FA Flush Aluminum 11/2" × 11/2" × 1" RA Regressed For more shielding see options and Aluminum accessories section. PS Premium Steel – VOLTAGE U 120V-277V 347 347V BALLAST E Electronic T8, Instant Start 3E 3-Lamp Electronic T8, Instant Start EP Electronic T5 or T8, Programmed Start 3EP 3-Lamp Electronic T8, Programmed Start For specific ballast vendor, show as option. OPTIONS F830 T8, 78+CRI, 3000K Lamps, Furnished/Installed F835 T8, 78+CRI, 3500K Lamps, Furnished/Installed F841 T8, 78+CRI, 4100K Lamps, Furnished/Installed F0835 T8, 82CRI, 3500K Lamps, Furnished/Installed GLR Fast Blow Fuse EL Emergency Battery Pack PAF Paint After Fabrication SLL Spring Loaded Latches MS9 Master/Satellite Pair w/9' Harness C388 3/8" Flex with 3 No. 18 Wires C488 3/8" Flex with 4 No. 18 Wires NYC NYC Compliant NYCU NYC Compliant, Union Label CP Chicago Plenum For a complete set of options, see options and accessories section. LENSED TROFFERS / ST814 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com ST814 1' × 4' Shallow Specification Troffer / 2-Lamp T5, T5HO, 2 or 3-Lamp T8 PHOTOMETRIC DATA Ballast Ballast Factor Lamp Lumens per Lamp Total Input Watts Mounting Reflectance Shielding Angle Spacing Criterion AVG. LUMINANCE (Candela/Sq. M.) ST814-232G-FSA12 ST8 Lensed Troffer 1 × 4 2-Lamp with A12 Prismatic Acrylic Lens REL-2P32-SC 0.88 F32T8 2900 59 Recessed PCW 95.2 0º = 90 90º = 90 0° = 1.23 90° = 1.16 COEFFICIENTS OF UTILIZATION (%) 0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85 6843 6504 5896 5381 4840 4324 3732 3243 2968 2924 3194 3402 6843 6472 5782 5263 4667 3977 3300 2814 2580 2601 2732 3082 6843 6311 5446 4918 4417 3813 3083 2459 2101 2224 2651 2801 6843 6094 5222 4716 4194 3588 3027 2732 2682 2763 3033 3562 6843 6009 5191 4696 4189 3618 3139 2864 2794 3032 3374 3642 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 25.8 40.8 64.0 74.9 74.9 RC RW 1 2 3 4 5 6 7 8 9 10 70 82 76 70 64 59 55 51 48 45 42 80 50 30 79 76 70 65 62 57 56 50 50 44 46 40 42 36 38 32 35 30 33 27 10 73 61 52 45 40 35 31 28 26 23 70 80 74 68 63 58 54 50 47 44 41 70 50 30 77 75 69 64 61 56 55 49 50 44 45 39 41 35 38 32 35 29 32 27 10 72 61 52 45 39 35 31 28 26 23 50 74 66 59 53 48 44 40 37 34 32 50 30 72 62 55 48 43 39 35 32 29 27 INDOOR CANDELA PLOT 10 70 59 51 44 39 35 31 28 25 23 0 0 64 55 48 42 37 33 29 26 24 22 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Lumens % Lamp % Fixt. 1497 2368 3715 4346 4346 RCR Luminaire Average Luminance Angle LUMINAIRE DATA Test 13767 Test Date 12/27/04 34.5 54.5 85.5 100.0 100.0 Total Luminaire Efficiency 74.9% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 65 Noncompliant $3.69 based on 3000 hrs. and $0.08 per KWH Test 13385 Test Date 4/14/03 LUMINAIRE DATA 85 N/A 0º = 1.25 0 30 40 45 50 55 60 65 70 75 80 85 8240 7964 7333 6729 6071 5434 4797 4215 3783 3604 3857 4104 8240 7984 7333 6749 6093 5428 4741 4115 3691 3549 3736 3983 8240 7992 7333 6764 6104 5422 4712 4082 3660 3549 3736 4104 8240 8154 7465 6858 6115 5288 4488 3883 3578 3658 3998 4586 8240 8166 7484 6888 6164 5355 4579 3991 3650 3658 3998 4425 90º = 1.28 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens % Lamp % Fixt. 1838 2974 4821 5706 5706 21.1 34.2 55.4 65.6 65.6 32.2 52.1 84.5 100.0 100.0 RCR Ballast Ballast Factor Lamp Lumens per Lamp Total Input Watts Shielding Angle Spacing Criterion COEFFICIENTS OF UTILIZATION (%) 0.0 22.5 45.0 67.5 90.0 ST814-332G-FSA12 ST8 Lensed Troffer 1' × 4' 3-Lamp with A12 Pattern Acrylic Prismed Lens REL3P32SC 0.88 F32T8 2900 Average Luminance Angle Luminaire AVG. LUMINANCE (Candela/Sq. M.) RC RW 1 2 3 4 5 6 7 8 9 10 70 72 66 60 56 51 48 44 41 39 36 80 50 30 69 66 61 57 54 49 48 43 43 38 39 34 36 30 33 27 30 25 28 23 10 64 53 45 39 34 30 26 24 22 20 70 70 64 59 54 50 46 43 40 38 36 70 50 30 67 65 60 56 53 48 47 42 43 37 39 33 35 30 32 27 30 25 28 23 10 63 53 45 38 34 30 26 24 21 20 50 65 57 51 46 41 38 34 32 29 27 50 30 63 54 47 41 37 33 30 27 25 23 INDOOR CANDELA PLOT 10 61 51 44 38 33 29 26 24 21 19 0 0 56 48 41 36 31 28 25 22 20 18 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Total Luminaire Efficiency 65.6% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 59 Noncompliant $4.07 based on 3000 hrs. and $0.08 per KWH DIMENSIONAL DATA 2-LAMP 41/2" 48" 41/4" A K 113/4" 1' × 4' 2-Lamps Lay-in 35/32" 41/2" A - 7/8" Diameter Knockout K - 2" × 3" through hole for access plate 41/4" 123/4" × 495/8" 1' × 4' 2-Lamps Flanged 521/32" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Flanged cut out dimensions for single unit only: 12" × 481/8" Page 2/2 Rev. 03/15/17 LENSED TROFFERS / ST814 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com