PhoCheck Tiger Select Instrument User Manual V1.1 Tiger_Select_V1_1 V1 1
User Manual: Pdf Tiger_Select_V1_1
Open the PDF directly: View PDF .
Page Count: 19
Download | |
Open PDF In Browser | View PDF |
PhoCheck TIGER SELECT Instrument User Manual V1.1 For Sales & Service Contact 2650 E. 40th Ave. • Denver, CO 80205 Phone 303-320-4764 • Fax 303-322-7242 1-800-833-7958 www.geotechenv.com Register your instrument online to receive your Extended 5 year Warranty. See page 44 of the Standard TIGER Manual for details. rt Number: 861489 PhoCheck TIGER Select Ion Science Ltd About this Manual This manual describes the function and operation of the TIGER Select instrument. It is a supplement to the standard Phocheck Tiger manual (Part number: 861265) and should be used together with the standard manual. Please read and understand both user manuals completely before operating the TIGER Select instrument. Page 1 of 19 PhoCheck TIGER Select Ion Science Ltd Contents Page About this Manual Contents Statements Responsibility for use Caution Quality Assurance Disposal Calibration Facility Ion Science Contact Details Introduction to PhoCheck TIGER Select Getting Started Understanding the Display Screen Start up screens Soft Key areas Using your TIGER Select TIGER Select mode TIGER PC Software Maintenance Calibration Probes TIGER SELECT Parts Main Assembly Front End Filter Assembly Accessories Instrument Warranty and Service Technical Specification Manual History 1 2 3 3 3 3 3 3 3 4 5 6 6 6 7 8-9 10 11-12 11 12 13-14 13 14 Please refer to Tiger Manual Please refer to Tiger Manual 15 16 Page 2 of 19 PhoCheck TIGER Select Ion Science Ltd Statements RESPONSIBILITY FOR USE Inadequate performance of the gas detection equipment described in this manual may not necessarily be self-evident and consequently equipment must be regularly inspected and maintained. Ion Science recommends that personnel responsible for equipment use institute a regime of regular checks to ensure it performs within calibration limits, and that a record be maintained which logs calibration check data. The equipment should be used in accordance with this manual, and in compliance with local safety standards. LEGAL NOTICE Whilst every attempt is made to ensure the accuracy of the information contained in this manual, Ion Science accepts no liability for errors or omissions, or any consequences deriving from the use of information contained herein. It is provided "as is" and without any representation, term, condition or warranty of any kind, either express or implied. To the extent permitted by law, Ion Science shall not be liable to any person or entity for any loss or damage which may arise from the use of this manual. We reserve the right at any time and without any notice to remove, amend or vary any of the content which appears herein. !CAUTION! It is essential that the PhoCheck TIGER is always used with a supplied PTFE 0.5 micron filter fitted to the front of the instrument. Without a filter, particles of debris and dust can be drawn into the detector inhibiting the function of the instrument. These filters are consumable and should be changed after every 100 hours of use. The frequency of replacement should be increased for dusty or moisture laden environments. Filters are available from your distributor or at www.ionscience.com . Quality Assurance PhoCheck TIGER has been manufactured in compliance with ISO9001:2000, which ensures that the equipment supplied to our customers has been designed and assembled reproducibly, from traceable components, and leaves Ion Science calibrated to stated standards. Disposal Dispose of PhoCheck TIGER, its components and any used batteries in accordance with all local and national safety and environmental requirements. This includes the European WEEE (Waste Electrical and Electronic Equipment) directive. Ion Science Ltd offers a take back service. Please contact us for more information. The PhoCheck TIGER field case material is recyclable polypropylene. Calibration Facility Ion Science Ltd offers a calibration service including the issue of certification confirming calibration with equipment traceable to national standards. A PhoCheck TIGER calibration kit is available from your distributor or service centre or at www.ionscience.com . Ion Science recommends annual return of all instruments for yearly service and calibration. Ion Science Contact Details UK Head Office Ion Science Ltd The Way, Fowlmere Cambridge SG8 7UJ UK Tel: +44 (0)1763 207206 Fax: +44 (0) 1763 208814 Email: info@ionscience.com Web: www.ionscience.com USA Office Ion Science Americas LLC 33 Commercial Drive Waterbury VT 05676 USA Tel: +1 802 244 5153 Fax: +1 802 244 8942 Email: info@ionscienceamericas.com Web: www.ionscience.com Page 3 of 19 German Office Ion Science Messtechnik GMBH Laubach 30 Metmann-Neandertal 40822 GERMANY Tel: +49 2104 14480 Fax: +49 2104 144825 Email: info@ism-d.de Web: www.ism-d.de PhoCheck TIGER Select Ion Science Ltd Introduction to PhoCheck TIGER Select Benzene vapour is carcinogenic. Benzene is a constituent of certain types of fuel, and used as a solvent, and in the production of a wide range of chemicals and plastics. PID technology can easily detect Benzene vapour as well as many of other volatile organic compounds. The Tiger Select uses a combination of a ultraviolet and chemical filtering to deliver a response to Benzene free from interferents. When the Select upgrade is activated, data logging, H&S mode and ppb automatically become available. At start up a specific Select screen appears however the instrument initially runs like a standard Tiger. When in Select mode the instrument takes control over many of the standard features. The Tiger Select uses a standard 10.6 eV lamp and a selective 10 eV filter incorporated in the pellet/stack. The lower eV output prevents sensing many of the gases co-present in Benzene containing atmospheres. 10.0eV 10.6eV The Tiger Select starts up in normal running mode. Ion Science recommend operating the instrument in the working environment for 10 to 15 minutes before use. This allows the tubes and instrument to acclimatize and ensures the best results. Ion Science suggest that the TIGER Select is calibrated before each use and a new PID-Pre –Filter Tube is used. With no tube fitted, the customer can check the general VOC level, if there are no VOC's present then no tube test is required. Page 4 of 19 PhoCheck TIGER Select Ion Science Ltd Getting started The TIGER Select has all the features and functions of the standard TIGER instrument with the additional feature of Benzene detection using the PID-Pre-Filter Tube in TIGER Select mode.. This manual describes the operation of the TIGER in the TIGER Select mode indicated by the following symbol. When first turned on, the TIGER Select will run through a start up routine as described below in ‘Understanding the display screen’. The TIGER Select will then run in standard mode with all the standard TIGER functions. All standard functions are described in the Standard TIGER manual (part number 861265). When in TIGER Select mode the instrument will default to the Benzene calibration. PID-Pre-Filter Tube for Benzene. The PID-Pre-Filter Tube is used in a specifically designed way with the TIGER Select. The instructions supplied with the tubes do not affect the operation of the TIGER Select. Please note: 1. If your TIGER Select has just been calibrated please ensure that a new PID-Pre-Filter Tube is used when in TIGER Select mode. 2. A 10eV filter Pellet is fitted to the TIGER Select is used for Benzene and Isobutylene detection. To revert to the full standard TIGER function with the whole range of gases the 10eV filter should be replaced with a standard 10.6eV pellet. Ensure that the 10.6eV lamp is selected from the Tiger PC Software. A custom calibration should then be carried out. Page 5 of 19 PhoCheck TIGER Select Ion Science Ltd Understanding the display screen Start up screens Start up the instrument by pressing the ON/Off key A sequence of screens will appear displaying the following:Screen 1: Test screen where all fixed icons are shown Screen 2: The Ion Science logo is presented Screen 3 The TIGER Select logo. Screen 4: Instrument identification; PhoCheck Tiger (default), IRN number, Firmware version Screen 5: Lamp strike routine. Animated dots indicate progress. When the lamp strikes, 'OK' will appear Soft key areas The following icons will appear in the soft key areas as soft key options. They are selected using the UP and DOWN keys. These icons can be reorganised using the TIGER Select PC software (refer to Standard TIGER manual). Button A Button B Information Options Tiger Select mode Average Multiple data logging (optional) Data log (optional) Gas selection Zone(s) Zeroing Sleep Health & safety (optional) Peak hold Refer to the Standard TIGER manual for a description of all the soft key functions. This manual now describes, in detail, the operation of the TIGER Select Function only. Page 6 of 19 PhoCheck TIGER Select Ion Science Ltd Using your TIGER Select INFORMATION Pressing the Information soft key allows access to a number of other information screens. Use the DOWN key to scroll through the screens. Press ESCAPE to return to the main screen: First Screen Gas selected Response Factor Upper alarm Lower alarm Second screen Lamp selected Date of factory calibration Date of custom calibration Date of benzene calibration Third Screen SPAN 1 (gas concentration set in TIGER PC) SPAN 2 (gas concentration set in TIGER PC) PID detector A/D reading Temperature Fourth Screen STEL TWA Internal Reference Number (IRN) Firmware version Bootloader version Battery type and status Fifth Screen Memory Status Gas table date. Date and time Sixth Screen Features. An icon will appear for each feature available on this instrument. Page 7 of 19 PhoCheck TIGER Select Ion Science Ltd Using your TIGER Select TIGER Select mode Please note: If your TIGER Select has just been calibrated please ensure that a new PID-Pre-Filter Tube is used. Ion Science suggest that the TIGER Select is calibrated before each use. Press the TIGER Select soft key to display the icon that indicates that the PID-Pre-Filter should be inserted (part number 5/FD-01). Do not insert the PID-Pre-Filter until Both ends of the tube have been removed as below. Remove both ends of the PID-Pre-Filter tube with the Glass Tube Cutter supplied with your TIGER Select (part number 5/FD-02). Insert the PID-Pre-Filter tube into the glass tube cutter and turn the tube to cut the glass. Unscrew the probe and insert the PID-Pre-Filter Tube. Now replace the probe. Press the Enter button. Page 8 of 19 PhoCheck TIGER Select Ion Science Ltd Using your TIGER Select (continued) The TIGER Select will now take a sample over 150 seconds. During this time the other soft keys will be disabled. At the end of the sample the display will show the level of Benzene detected in the in the location that the instrument has been sampling. To return to the main screen press Esc and confirm with the Enter button. An idication of the gas selected is for normal Tiger operation is then shown. If the Health & Safety option is enabled (via Tiger PC) the instrument will run for a 15 minutes STEL after the initial Benzene test. The icon in the bottom left corner will flash as indication to the user to press the enter button to observe the STEL routine. At the end of the routine the final result will be displayed. To escape the routine at any time press the Esc button and confirm by pressing the Enter button. IMPORTANT: Tiger Select STEL. While the Tiger Select calculates the 15 minute STEL the instrument displays the ongoing STEL as it is calculated. This ongoing calculation is for indication purposes only to allow the user to gauge how the calculation is progressing. Only the final reading at the end of the calculation is logged by the instrument and should be referenced by the user. Page 9 of 19 PhoCheck TIGER Select TIGER PC Software Ion Science Ltd ________________________________________ Please Refer to the standard TIGER manual for the TIGER PC Software user information. The TIGER Select Configuration screen will show the window below. The calibration default is 10 ppm benzene. To run the Health & Safety mode tick the STEL calculation after the initial Benzne test. box. This will then allow the option to run a 15 minute Page 10 of 19 PhoCheck TIGER Select Ion Science Ltd Maintenance CALIBRATION Please Refer to the standard TIGER manual for Factory and Customer calibration. TIGER Select mode will operate against a benzene calibration. Readings taken against unsatisfactory calibrations may be unreliable. For Benzene Calibration, first set up the parameters in TIGER PC - see page 10. TIGER Select allows you to custom calibrate using 10ppm Benzene gas. Each cylinder should be regulated for a flow rate above 250ml/min. Note: Have on hand the cylinder(s) of gas, regulator(s) and PIDPre-Filter Benzene Tube before starting the procedure. Please ensure you are familiar with the entire calibration procedure before attempting to calibrate your TIGER Select. Press the Options soft key access the adjustable features. on your TIGER Select to Then use the UP or DOWN key to select calibration. Press ENTER to confirm selection. Select TIGER Select Calibration and press Enter to confirm. On confirming the selection, the user is presented with a prompt to insert the PID-Pre-Filter Tube (part number 5/FD-01). Remove both ends of the PID-Pre-Filter tube as described on page 9. Now connect the tube from the gas cylinder to the end of the probe. Now Press the Enter button. A screen will be shown with a countdown In seconds. Turn on the gas and press the enter button. The countdown will begin. When the countdown has finished a tick will indicate that the calibration has finished. Press enter to confirm the calibration. Page 11 of 19 PhoCheck TIGER Select Ion Science Ltd Maintenance Probes Should the probe become cantaminated or damaged, replacement probes may be obtained from your distributor or from Ion Science Ltd. Please note that a small ‘O ring’ at the base of the probe ensures the probe is sealed, this can be seen in the transparent filter housing when the probe is removed. The probe can be removed for cleaning or replacement by unscrewing it from the transparent filter housing. Refit the probe using fingers only, avoid using tools as this may damage the filter housing. To ensure the assembly is sealed, place a finger over the probe to block the flow while the instrument is running. A flow alarm should occur if sealed correctly. Page 12 of 19 PhoCheck TIGER Select Ion Science Ltd TIGER Select Parts TIGER Select Main Assembly Page 13 of 19 PhoCheck TIGER Select Ion Science Ltd TIGER Select Parts Front End Filter Assembly Page 14 of 19 PhoCheck TIGER Select Ion Science Ltd Technical Specifications Please Refer to the standard TIGER manual for the full specification of the Standard TIGER instrument. Benzene Detectable Range 0.01 – 40 ppm Benzene. Page 15 of 19 PhoCheck TIGER Select Ion Science Ltd Manual History Manual version 1.0 1.1 Amendment Issue Date First issue Front cover issue updated to V1.1 Page 9, Health and Safety mode added. Page 10 Health and Safety mode added. Page 16 of 19 27/02/2011 8/04/2011 Instrument Firmware V 0.3.85 V0.3.93 PC Software V 1.0.0.42 V1.0.0.45 PhoCheck TIGER Select Ion Science Ltd This page is deliberately left blank Page 17 of 19 PhoCheck TIGER Select Ion Science Ltd This page is deliberately left blank Page 18 of 19
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : andrew Create Date : 2011:04:15 10:44:04Z Modify Date : 2011:07:22 13:41:41-06:00 Has XFA : No Language : en-GB Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Format : application/pdf Creator : andrew Title : PhoCheck Tiger Select Instrument User Manual V1.1 Creator Tool : Microsoft® Office Word 2007 Metadata Date : 2011:07:22 13:41:41-06:00 Producer : Microsoft® Office Word 2007 Document ID : uuid:1d40699a-3242-d14b-b2b8-fcb9a7486710 Instance ID : uuid:918985db-efd7-a74e-82f6-d2f9669ac3a4 Page Count : 19EXIF Metadata provided by EXIF.tools