Unicom 2500 User Manual V.1.03 Communication Converter RS485 To RS232 Or Fiber Optic E118706
User Manual: Pdf Unicom 2500 Communication Converter RS485 to RS232 or Fiber Optic User Manual V.1.03 E118706
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
User Manual UNICOM 2500 • Installation • Operation • Programming ¯ Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive•Westbury, New York 11590 Tel 516.334.0870•Fax 516.338.4741• www.electroind.com (/(&752,1'8675,(6 *$8*(7(&+ UNICOM-2500 UNIVERSAL COMMUNICATION COVERTER USER'S INSTALLATION & OPERATION MANUAL Version 1.3/ 11-2014 1800 Shames Drive Westbury, New York 11590 Tel: (516) 334-0870 Fax: (516) 338-4741 UNICOM 2500 Address: Electro Industries/Gaugetech (EIG) 1800 Shames Drive Westbury, New York 11590 U. S. A For Customer or Technical Assistance, Repair and Calibration: Phone: (516) 334-0870 Fax: (516) 338-4741 Customer Support & Repair Service Customer support is available 9:00 A.M. to 4:30 P.M., Eastern Time, Monday through Friday. Please have the model, serial number and a detailed problem description available. If the problem concerns a particular reading, please have all meter readings available. When returning any merchandise to E.I.G., a return authorization number is required. PRODUCT WARRANTY: Electro Industries/GaugeTech warrants this product to be free from defects in material and workmanship for a period of 1 year from date of shipment. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. To exercise this warranty, fax or call our customer service department. You will receive prompt assistance and return instructions. Send the instrument, transportation prepaid, to the address above. Repairs will be made and the instrument will be returned. LIMITATION OF WARRANTY: This warranty does not apply to defects resulting from unauthorized modification, misuse, use for any reason other than electrical power monitoring. This unit is not to be used for primary over current protection. Any protection feature in this unit is to be used for alarm or secondary protection only. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability or fitness for a particular purpose. Electro Industries/GaugeTech shall not be liable for any indirect, special or consequential damages arising from any authorized or unauthorized use of any Electro Industries/GaugeTech product. STATEMENT OF CALIBRATION: This instrument has been inspected and tested in accordance with specifications published by Electro Industries/GaugeTech. The accuracy and calibration of this instrument are traceable to the National Bureau of Standards through equipment which is calibrated at planned intervals by comparison to certified standards. DISCLAIMER: Information presented in this publication has been carefully checked for reliability; however, no responsibility is assumed for inaccuracies. The information contained in this document is subject to change without notice. COPYRIGHT: No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage or retrieval systems or any future forms of duplication, for any purpose other than the purchaser's use, without the expressed written permission of Electro Industries/GaugeTech. Copyright (C) 2014 Electro Industries/GaugeTech. All rights reserved. Printed in the United States of America. UNICOM-2500 SPECIFICATIONS: Power Voltage: Requirements 9Vdc - 30Vdc or 7Vac-20Vac Maximum Power: Consumption 3VA Isolation Voltage: 2500Vrms (RS232 to RS485) Data rate: 1200 - 115,000 baud Switches: DTE-DCE selection HALF-FULL duplex selection (HD/FD) 232/FO-232/485-485/FO selection. Only with fiber optic option Indicator Lights: TX transmit RX receive CTRL control ERR error Connectors: DB-9(RS-232) 5 screw terminal (RS-485) ® ST receive and transmit (Fiber Optic), optional Enclosure: Rugged aluminum resistant to Electro Magnetic Interference (RS232 or Fiber Optic) (RS232 or Fiber Optic) (RS485) (RS232 or Fiber Optic) 7 9 Outside Dimensions: L=4 /8” (124mm), W=2 /16”(65mm), H= 1”(25mm) Mounting: Stand alone or wall mounted with mounting plate supplied Operating Temperature: -20C to +70C Port Configuration: 0 0 RS232 - 9 Pin Female RS485 - 4 wire and 2 wire connector Fiber Port - 50/125µm, 62.5/125µm and 100/140µm fiber sizes using ST terminated cables. Wavelength=820nm (OHFWUR,QGXVWULHV *$8*(7(&+ 1 Unicom Installation & Operation CONNECTORS: RS-232 Port: Switch Position DCE DTE pin name 2 TX 3 RX GND 5 pin name 2 RX 3 TX GND 5 RS-485 Port: Pin assignment is also indicated on the enclosure TX- RX- TX+ RX+ GND Rear view of enclosure FIBER OPTIC PORTS (optional) : TX Power Connection: RX ® The Fiber Optic ports accept ST terminated fibers (50/125µm, 62.5/125µm, 100/140µm) Rear view of enclosure DC Jack barrel type (not polarized) Outside diameter: 5.5mm Inside diameter: 2.5mm (OHFWUR,QGXVWULHV *$8*(7(&+ 2 Unicom Installation & Operation HOOKUP DIAGRAMS: RS-232/RS-485 CONVERSION: 4 Wire (Full Duplex installation) COMPUTER (DTE) T+ AC XFORMER TR+ R- RS-232 Port DCE DTE Bus Devices 232/FO 485/FO 232/485 T+ Baud Rate Selector HD FD Fiber Optic Port RX TX TX- RX- TX+ RX+ GND RS-485 Port shield Twisted pair shielded cable (OHFWUR,QGXVWULHV *$8*(7(&+ 3 Unicom Installation & Operation HOOKUP DIAGRAMS: RS-232/RS-485 CONVERSION: 2 Wire (Half Duplex installation) COMPUTER (DTE) AC XFORMER T- Bus Devices RS-232 Port DCE DTE 232/FO 485/FO 232/485 TBaud Rate Selector HD FD Fiber Optic Port RX TX TX- RX- TX+ RX+ GND RS-485 Port jumpers short RX+ to TX+ short RX- to TX- shield Twisted pair shielded cable (OHFWUR,QGXVWULHV *$8*(7(&+ 4 Unicom Installation & Operation HOOKUP DIAGRAMS: RS-232/FIBER OPTIC CONVERSION: COMPUTER (DTE) AC XFORMER RS-232 Port DCE DTE 232/FO 485/FO 232/485 Baud Rate Selector HD FD Fiber Optic Port RX TX TX- RX- TX+ RX+ GND RS-485 Port RX TX Device with Fiber Optic Port (OHFWUR,QGXVWULHV *$8*(7(&+ 5 Unicom Installation & Operation HOOKUP DIAGRAMS: RS-485/FIBER OPTIC CONVERSION: 2Wire (Half Duplex installation) AC XFORMER T+ T- RS-232 Port DCE DTE Bus Devices 232/FO 485/FO 232/485 T+ Baud Rate Selector HD T- FD Fiber Optic Port RX TX TX- RX- TX+ RX+ GND RS-485 Port shield jumpers short RX+ to TX+ short RX- to TX- Twisted pair shielded cable RX TX Device with Fiber Optic Port (OHFWUR,QGXVWULHV *$8*(7(&+ 6 Unicom Installation & Operation HOOKUP DIAGRAMS: RS-485/FIBER OPTIC CONVERSION: 4Wire (Full Duplex installation) AC XFORMER T+ RS-232 Port DCE DTE 232/FO 485/FO Bus Devices 232/485 T+ Baud Rate Selector HD FD Fiber Optic Port RX TX TX- RX- TX+ RX+ GND RS-485 Port shield Twisted pair shielded cable RX TX Device with Fiber Optic Port (OHFWUR,QGXVWULHV *$8*(7(&+ 7 Unicom Installation & Operation DESCRIPTION OF FEATURES SWITCHES: DTE-DCE : Configures the wiring of the RS-232 port. When DCE (Data Communication Equipment) is selected the Unicom-2500 receives data on Pin3 and transmits on Pin2 (DB-9 connector). When DTE (Data Terminal Equipment) is selected, Pin3 is the transmit and Pin2 is the receive. For example if the Unicom-2500 is connected to a computer, DCE should be selected. If it is connected to a modem or another Unicom2500(with DCE selected) DTE should be selected. CONFIGUARATION SWITCH (RS232/FO - RS232/RS485 - RS485/FO), only for units with Fiber Optic Option: Determines the path for the throughput. FD-HD(Full Duplex/Half Duplex),(RS-485): Used to setup the Unicom-2500 for Full Duplex or Half Duplex mode. Full duplex requires a 4 wire hookup on the RS-485 Bus to enable simultaneous receive and transmit. In this mode, the Baud Rate Selector Switch is not enabled since there is no need to control the RS485 transmit driver (Receive is constantly enabled). Half Duplex mode requires only two wires to be hooked up on the RS-485 Bus. In this mode, transmit and receive signals are on the same pair of wires. When the unit is transmitting, the receive device is disabled, when the transmission is complete the unit is then in the receive mode (receive enabled). The Unicom-2500 automatically controls this operation. It only needs the Baud Rate to determine the turnaround time from transmit to receive, therefore the Baud Rate selection switch must be in the right position! See also software/firmware considerations in Half Duplex mode (Pg. 11). Halfl Duplex installation requires these modifications on the RS-485 connection port! : TX+ Pin connected to RX+ Pin (use jumper wire) TX- Pin connected to RX- Pin (use jumper wire) Baud Rate Selector Switch (For Half Duplex, two wire setup only): Sets up the current communication Baud Rate. Range : 1200 to 115000 Baud. (OHFWUR,QGXVWULHV *$8*(7(&+ 8 Unicom Installation & Operation STATUS LIGHTS: Power: Indicates the unit is on RX: Indicates the RS-232 or Fiber Optic port is receiving TX: Indicates the RS-232 or Fiber Optic port is receiving ERR: Indicates an illegal condition on the RS-232 or Fiber Optic port. A start bit is detected on the RS-232 or Fiber Optic receive line, but there is no data. This condition would enable the transmit driver on the RS-485 port forever which would load down the RS-485 Communication Bus. When the ERR light comes on, Unicom-2500 automatically disables the transmit driver to prevent this unwanted situation. Such a condition is usually caused by software/firmware lockup. A new start bit will reset the unit. CTRL: indicates the RS-485 port data direction, and is used only in Half Duplex mode. The On state indicates transmit, the Off state indicates receive. (OHFWUR,QGXVWULHV *$8*(7(&+ 9 Unicom Installation & Operation RS485 WIRING For long distances or higher baud rates use high quality twisted pair shielded cable. Termination of the transmission line is also recommended. The termination resistor is usually 100Ω 1/2W and not less than 90Ω. Termination resistors should be hooked up at the first device and the last device on the transmission line. RX+ TX+ RX TX First Device TX- RX- RX+ TX+ RX- TX- Last Device TX RX Connection to other devices Fig.1 Full Duplex installation with terminating resistors. In Half Duplex (two wire) installation there are only two terminating resistors to hook up. (OHFWUR,QGXVWULHV *$8*(7(&+ 10 Unicom Installation & Operation Software/Firmware considerations when using RS-485 Half Duplex(two wire) installation: In Half Duplex mode care must be taken in order to achieve successful operation. The automatic control of the Unicom-2500 detects the transitions on the incoming RS-232 or Fiber Optic(optional) receive line. When a transition occurs it enables the transmit driver of the RS-485 port. After the last transition is detected, the unit holds transmit enable for 13 bit-times, disables the transmit driver, and then enables the receive device of the RS-485 port. In order to avoid collisions on the transmission line, a time delay of at least 13 bits must be inserted before transmitting back to Unicom-2500. (OHFWUR,QGXVWULHV *$8*(7(&+ 11 Unicom Installation & Operation DIN Rail Mounting Procedure The Unicom 2500 comes with a Mounting Plate kit, consisting of a mounting plate and three screws for attaching it to the back of the Unicom 2500, and a DIN Rail Clip kit, consisting of 2 DIN rail mounting clips with an 8mm screw and lock washer for each clip. The mounting plate kit is in the plastic bag attached to the Unicom 2500, and the DIN Rail Clip kit is in a plastic bag in the Unicom 2500 box. The mounting plate and clips let you easily attach the unit to a DIN Rail. To use the DIN rail mounting clips, follow this procedure: 1. Attach the mounting plate to the back of the Unicom using the three screws packaged with it. Screw mounting plate onto back of the Unicom 2500 2. Using the screws provided in the DIN Rail Clip kit, attach the clips to the back of the mounting plate, using the two side holes, as shown in the drawing below. E Electro Industries / 12 GAUGETECH Unicom Installation & Operation a. From the front of either bracket, insert the screw into the lock washer and through the hole, and screw it into the clip using an appropriate screwdriver. Note that the clip should be positioned as shown above, with the indented side facing the back. b. Repeat step a for the second bracket. 3. To attach the clips to the DIN rail, hook the bottom of the clips around the bottom of the DIN rail and then push the top of the clips forward so that they fit over the top of the DIN rail. See the figure below. 2. Fit this over the DIN rail 1. Hook these under the DIN rail E Electro Industries / 13 12 GAUGETECH Unicom Installation & Operation
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Electro Industries Create Date : 1999:10:20 12:39:11Z Modify Date : 2014:11:19 08:50:17-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 4.0 for Windows Creator Tool : PSCRIPT.DRV Version 4.0 Metadata Date : 2014:11:19 08:50:17-05:00 Document ID : uuid:5b133192-85f7-4698-b624-b2f3d611539d Instance ID : uuid:2da5c514-6b23-4b86-a198-f00669bb6bc8 Format : application/pdf Title : Unicom 2500 User Manual V.1.03 Creator : Electro Industries Page Count : 16EXIF Metadata provided by EXIF.tools