Installation Instructions
30-3001-502
Rev C

CX9702 SiteController

Mounting Screw
N

2

1. Disable DHCP; set the IP address of your PC to 169.254.1.2
2. Connect Crossover cable from Ethernet port to the PC
3. Run Web Browser. Go to url: http://169.254.1.1/main
4. Logon using default Andover Controls username, password
5. Enter parameters on web screen

L

3

TO RESET IP ADDRESS to DEFAULT 169.254.1.1
Remove Cover
Press and hold IP button until the CPU light illuminates steady on
The controller is now reset to its factory default condition
Reconfigure as indicated above

FUSE F2
250 VAC 1.5 A

CAUTION

(L)

MORE THAN ONE DISCONNECT SWITCH
MAY BE REQUIRED TO DE-ENERGIZE THIS
EQUIPMENT BEFORE SERVICING.

4 + 12V OR 24VDC
5

24VDC 12VDC

@ 100mA

-

IN1

7

IN2

8

RET

9

IN3

10 IN4

INTERNAL

ON

INPUT
REFERENCE
RESISTOR

NC

LOCK

C

C

NO

NO

RET

RET

+

PS

-

16 IN8

Optional:
Required for lock voltage
feedback and internal
MOV protection.

NCSeries

NCSerPar

10K OHM
RESISTOR

KIM Board
Required to
parallel Keypads
with Readers

D
A
T
A
/
1

C
L
K
/
0

L
E
D
2

22 23

L
E
D
1

P
W
R

G
N
D

18

19 20 21

RS-485
STATUS

RS-485

CHANNEL 2

RET 43

LOCK2

AC PWR

SERVICE
PORT

TD

FUSE F7
125 VAC 3.5 A

LOCK 2 POWER
SOURCE

RS-232
STATUS
OFF AUTO ON

INTERNAL
EXTERNAL

P
W
R

G
N
D

D
A
T
A
/
1

C
L
K
/
0

L
E
D
1

L
E
D
2

24

25 26

27

28

29

30 31 32

RD

+

ONLINE

SHLD

RD

ETHERNET
10/100 MB

OUT3

RTS

OUT 3

DCD

OUTPUT
OVERRIDE
OUT 4

45

NO 44

SYSTEM
STATUS
CPU

DTR
CTS
DCD
RTS
GND
RD
DSR
TXD

12VDC 5VDC

OUTPUTS
NC 46
C

LOCK1

CABLE TYPE:
22-24 AWG, twisted pair, shielded
100-120 ohm Impedance
<12.5pF between conductors

NOSerPar
10K OHM
RESISTORS

10K OHM
RESISTORS

READERS/KEYPADS

@180 mA @120 mA

FUSE F6
125 VAC 3.5 A

LOCK 1 POWER
SOURCE

EXTERNAL

RS-485

RECOMMENDED SUPERVISED INPUT TYPES

CHANNEL 1

OUTPUT CONTACTS

INTERNAL

17 RET
CLASS 2
READER POWER

12VDC 24VDC
@1 A @300 mA LOCK 2 PWR

LOCK

NC 42
C

41

NO 40
RET 39
NC 38
C

37

Outputs
(2 Door Locks,
2 General)

NO 36
NC 35

OUT4

1
2
3
4
5
6
7
8

14 RET
15 IN7

Battery
Connector

12VDC 24VDC

Jumper
Installed

DISCONNECT AC POWER BEFORE CHANGING ANY CLASS 2 POWER SELECTION JUMPER
S
U
P
E
R
V
I
S
E
D

Mounting Screw

24VAC/ 30VDC
@3 A

10K
OFF

LOCK 1 PWR

12 IN5
13 IN6

+

INTERNAL
EXTERNAL

5.12V

11 RET

Inputs
(4 Universal,
4 Supervised)

Jumper
Installed

NC

IN1
IN2
IN3
IN4
OFF ON

LOCK POWER
SOURCE

EXTERNAL

RESET IP BUTTON UNDER COVER

U
N
I
V
E
R
S
A
L

-

47

Each Lock

INPUTS
6

48

CLASS 2 INTERNAL
LOCK POWER

TYPICAL LOCK OUTPUT CONNECTIONS
LOCK POWER
SOURCE

CLEAR MEMORY
0-5VDC

12VDC

CX

(N)

CLASS 2
REX / AUX POWER

REX/AUX
Power
Connector

BATTERY

For help entering parameters on web screen,
invoke Help page from the web screen.

USE COPPER CONDUCTORS ONLY

AC Power
Supply Connector

FUSE F1
125 VAC 5 A

CONFIGURATION / SETUP

AC POWER
115-230 VAC
115 VA
50/60 HZ

1

C

34

NO 33

RS-232
OFF AUTO ON

ACTIVITY

Mounting Screw

LINK

Mounting Screw

Reader Inputs
Ethernet Port

RS-232
RJ485
Connector Connector

Service Port

Controller Installation
To install the controller, follow these steps:
1. Mount the controller in an enclosure or to a panel using
screws. (See the “Physical Dimensions and Mounting”
section of this document.)
NOTE: Read the “Wiring Rules” section of this document
before performing the next steps. Do not apply power
to the controller until all connections are secured.
2. Connect the AC power supply connector of the controller
to a standard 115V three-prong power cord.
3. Locate the REX/AUX power connector and jumpers. Configure the jumper to indicate either 12 or 24 VDC. (See the
“Power Connections” section of this document for jumper
settings.)

4. Locate the battery connector block and connect the battery to
the corresponding terminals. (See the “Power Connections”
section of this document.)
5. Connect the Ethernet and Communication Port connections
based on your requirements. (See the “Ethernet and Comm
Port Connections” section of this document.)
6. Connect the Universal Inputs, Card Reader/Keypad, and Form
C Digital Output connections based on your requirements. (See
the corresponding sections of this document.)
7. Apply power to the CX9702 controller.
8. Configure the controller using the controller’s embedded
WebServer pages and CyberStation online help topics.

© 2010 Schneider Electric., all rights reserved.

Physical Dimensions and Mounting
10.34”

(263 mm)

2.08”

(53 mm)

.30”

9.75”

(8 mm)

(247.7mm)

2

N

3

L

1. Disable DHCP, set the IP address of your PC to 169.254.1.2
2. Connect Crossover cable from Ethernet port to a PC
3. Run Web Browser. Go to url: http://169.254.1.1
4. Logon using default Andover Controls username, password
5. Enter parameters on web screen

CAUTION

(L)

MORE THAN ONE DISCONNECT SWITCH
MAY BE REQUIRED TO DE-ENERGIZE THIS
EQUIPMENT BEFORE SERVICING.

5

24VDC

@ 100mA

0-5VDC

8.00”

(203.2 mm)

IN1

7

IN2

8

RET

9

IN3

10

IN4

11

RET

12

IN5
IN6

13
14

RET

15

IN7

16

IN8

17

IN1
IN2
IN3
IN4

LOCK POWER
SOURCE

INTERNAL

INTERNAL

EXTERNAL

EXTERNAL

NC

NC

LOCK

5.12V

C

C

NO

NO

RET

RET

ON

INPUT
REFERENCE
RESISTOR

LOCK
FUSE F6
125 VAC 3.5 A

LOCK 1 POWER
SOURCE

S
U
P
E
R
V
I
S
E
D

NC 46
EXTERNAL

C

NCSeries

NCSerPar

10K OHM
RESISTOR

10K OHM
RESISTORS

KIM Board
Required to
parallel Keypads
with Readers

RS-485
STATUS

RS-485

CHANNEL 2

CPU
AC PWR

SERVICE
PORT

RET 43

SYSTEM
STATUS

CABLE TYPE:
22-24 AWG, twisted pair, shielded
100-120 ohm Impedance
<12.5pF between conductors

NOSerPar

10K OHM
RESISTORS

RS-232
STATUS
TD

LOCK2

NC 42
FUSE F7
125 VAC 3.5 A

LOCK 2 POWER
SOURCE
INTERNAL

OFF AUTO ON

EXTERNAL

30 31 32

G
N
D

D
A
T
A
/
1

C
L
K
/
0

L
E
D
1

L
E
D
2

P
W
R

G
N
D

D
A
T
A
/
1

C
L
K
/
0

L
E
D
1

L
E
D
2

18

19

20

21

22

23

24

25

26

27

28

29

+

SHLD

RD
ONLINE

RD
RTS

OUT 3

DCD

OUTPUT
OVERRIDE

ETHERNET
10/100 MB

OUT 4

45

NO 44

RS-485

RECOMMENDED SUPERVISED INPUT TYPES

CHANNEL 1

OUTPUTS

INTERNAL

P
W
R

5VDC

OUTPUT CONTACTS
24VAC/ 30VDC
@3 A

-

PS

DCD
CTS
DCD
RTS
GND
RD
DSR
TXD

12VDC

LOCK 2 PWR

24VDC

LOCK1

READERS/KEYPADS

@180 mA @120 mA

24VDC
12VDC
@1 A @300 mA

12VDC

DISCONNECT AC POWER BEFORE CHANGING ANY CLASS 2 POWER SELECTION JUMPER

RET

CLASS 2
READER POWER

+

LOCK 1 PWR

10K
OFF

OFF ON

Each Lock

LOCK POWER
SOURCE

RESET IP BUTTON UNDER COVER

U
N
I
V
E
R
S
A
L

CLASS 2 INTERNAL
LOCK POWER

TYPICAL LOCK OUTPUT CONNECTIONS

CLEAR MEMORY

INPUTS
6

+

SiteController

12VDC

12V OR 24VDC

-

-

47

CX

(N)

CLASS 2
REX / AUX POWER

+

48

OUT3

C

41

NO 40
RET 39
NC 38
C

37

NO 36
NC 35

OUT4

C

34

1
2
3
4
5
6
7
8

4

12VDC

TO RESET IP ADDRESS to DEFAULT 169.254.1.1
Remove Cover
Press and hold IP button while momentarily pressing Clear Memory button
Release IP button when CPU light blinks 3 times
Reconfigure as indicated above

FUSE F2
1.5 A
250 VAC

(225 mm)

BATTERY

For Help entering parameters into the web screen,
click the Help button

USE COPPER CONDUCTORS ONLY

8.87”

FUSE F1
5A
250 VAC

CONFIGURATION / SETUP

AC POWER
115/230 VA C
115 VA
50/60 HZ

1

NO 33

RS-232
OFF AUTO ON

ACTIVITY

.44”

(11 mm)

4x

.187”

(4.75 mm)

LINK

Note: This open class product must be
installed in a NEMA Type 1 enclosure.

Wiring Rules
These modules are intended for installation
within the enclosure of another product with a
minimum NEMA 1 rating or IP10 equivalent.
For reliable input operation, follow these input wiring guidelines:
• Never lay wires across the surface of a printed circuit board.
• Wires should never be within 1” or 25 mm of any component
on a printed circuit board.
• Use shielded input wire.
• Terminate the shield of the input wires at one end of the run
only — preferably at the end where your I/O module is located.
• When stripping wire, be careful not to drop small pieces of
wire inside the cabinet.
• Don’t run your input wiring in the same conduit with
AC power.
• Don’t run your input wiring in the same conduit with your
output wiring.

Grounding the Controller
To insure proper operation of the controller, it must be connected to
a good Earth ground. The connection must be made as close to the
module as possible.

Inspecting the Ground
Be sure to have your grounds inspected before you begin the installation
process.
Check your grounds as follows:
Inspect the building power distribution panel for Earth-ground termination. If the ground termination is any of the following, it is not adequate
and must be corrected:
• Does not exist
• Is connected to a corroded or galvanized pipe
• Is connected using a small gauge wire (less than 14 AWG).
Be sure your Andover Continuum cabinet is connected to the ground
with a copper conductor that terminates at the distribution panel.

Power Connections
Battery Back-Up Connection

AC Power Supply Connections

115-230 VAC ~
115 VA
50/60 HZ

Battery
N

115 Volts
AC Power

L

Note: Schneider Electric Battery part number:
01-2100-423 (12V/7.0 AHr lead-acid battery)
Back-up duration expandable by use of
greater amp-hour batteries.

REX/AUX Power Connection
Jumper selectable 12V or 24V DC @ 100mA

Jumper Settings

24VDC

12VDC

Ethernet and Comm Port Connections
Ethernet Cable w/
RJ-45 Connector

Service Port

RS-485 4-pin connector

Ethernet

For use with the RoamIO2

1

RS-485 Connector

+
Shield

3

1

RS-232 Connector
DTR
CTS
DCD
RTS
Ground
RD
DSR
TXD

8

Universal Input Connections
Each universal input connector contains four inputs as illustrated below. Each input can be operated as a supervised or general
purpose Universal Input. You can assign any input to any door or reader for any function, including: Door Switch input, Request
to Exit (REX), Alternate Door Access (ADA) REX Input, Bond Sensor input, and ADA Entry Request input.

Universal
Inputs

NOTE:
DIP Switches allow you to select whether
or not you want a pull-up resistor in the
circuit. Default is set to “ON” for general
use. To utilize one of these inputs as a
supervised input, the DIP switch must be
set to the “ON” Position.

IN1
IN2
RTN
IN3
IN4
RTN

Supervised Input Connections
Four supervised inputs can be used for closure contacts such as relays or switches. They provide connection of conventional normally open or normally closed contacts to the CX9702 SiteController. One or more 10K Ohm resistors must be placed across the input as shown below.
Supervised IN5
Inputs
IN6
RTN
IN7
IN8
RTN

Supervised Input Connection Wiring
Normally Closed (NC) Series Parallel

Normally Closed (NC) Series

External
Resistor
10 KΩ

External
Resistors
10 KΩ

AUX
or
DOOR
or
REX

AUX
or
DOOR
or
REX

Contact
Closure

Contact
Closure
RTN

RTN

Normally Open (NO) Series Parallel
External
Resistors
10 KΩ

AUX
or
DOOR
or
REX

Contact
Closure
RTN

Card Reader/Keypad Connections
Each card reader/keypad connector contains an input as illustrated below. Each reader input can be connected to a card reader,
dedicated keypad, or a reader/keypad combination. A Keyboard Interface Module (KIM) is required to connect separate reader and
keypad devices on the same reader input. Card reader voltage (+5 VDC or +12 VDC) is jumper selectable. The jumpers are located
to the left of the card reader connectors on the main board.

Card Reader Voltage
Jumper Settings
(Single Pin)

Card Reader/
Keypad Inputs

+5VDC
(Default)

Card
Reader2

Card
Reader1

PWR
GND
DATA1
CLK0
LED1
LED2

PWR
GND
DATA1
CLK0
LED1
LED2

+12VDC

NOTE: Disconnect AC power before
changing any Class 2 Selection Jumper.

Connecting a Single Card Reader

PWR (+5 VDC or +12 VDC
Set by Voltage Jumper)

GND

PWR

Weigand
Reader
or
Reader with Keypad

GND

DATA / I

DATA I
DATA 0
LED1
LED2
CLK / 0

LED1
LED2

Card Reader/Keypad Connections (Continued)
Connecting Two Readers or a Keypad and a Reader
With the addition of the Keypad Interface Module (KIM), the controller can interface to both a keypad and a reader simultaneously. This assumes
that they are both Wiegand devices of similar voltage range. The KIM module presents the CX9702 SiteController with one pair of signals.

CX9702
SiteController
PWR
(Set by
Voltage
Jumper)

GND
PWR

Wiegand Reader
or
Reader with Keypad
or Keypad only

GND
LED
DATA 1
DATA 0
LED

Keypad Interface Module
P3
DATA / I
DATA / 0

P1
DATA / I

DATA / I

CLK / 0

CLK / 0

P2
DATA / I
DATA / 0

DATA 1

Wiegand Reader
or
Reader with Keypad
or Keypad only

DATA 0
LED
GND
PWR

Door Lock Power Connections
The two door lock output connections on the CX9702 SiteController can be supplied power internally from the controller or externally from a separate power supply. Power sourcing is jumper selectable. Jumpers are located to the left of each lock output connection.

CLASS 2 INTERNAL
LOCK POWER

TYPICAL LOCK OUTPUT CONNECTIONS
LOCK POWER
SOURCE

LOCK POWER
SOURCE

INTERNAL

INTERNAL

EXTERNAL

EXTERNAL

NC

LOCK

NC

C

C

NO

NO

RET

RET

+

Each Lock

LOCK 1 PWR

24VDC
12VDC
@1 A @300 mA

12VDC

PS

-

LOCK 2 PWR

24VDC

LOCK

Note: If used, the voltage of internally
supplied power is indicated by a
jumper selection, as shown above.

Door Lock/Form C Digital Output Connections
The CX9702 SiteController includes four Form C single-pole double-throw relay outputs, two of which are commonly used for door lock outputs. Form C relays contain both a normally open (NO) and a normally closed (NC) output. These output contacts operate as a standard relay, as
described in the “Relay Operation” text box. The illustration below is a simplified schematic of each output channel.

OUTx NC

OUTx COM

OUTx NO

Relay Operation:
When the output is set to ON:
• NO contacts close
• NC contacts open

Door Lock/Form C Digital Output Connections (Continued)
Wiring Door Outputs (NO Circuit)
The illustration below represents a typical door output installation when the circuit is normally open (NO). The figure shows a normally
de-energized lock (when secured) in a fail secure mode. Always be sure to use “panic” hardware that allows emergency exit from the secured area.
Note the location of the metal oxide varistor (MOV) and the Door Strike electric locking mechanism.

Power Supply
(UL listed power supply)

12 or 24 VDC

MOV
(Schneider Electric #01-2020-095)

C
Door Strik e
(UL 1076 listed)

Wiring Door Outputs (NC Circuit)
The illustration below represents a typical door output installation when the circuit is normally closed (NC). The figure shows a normally
de-energized lock (when secured) in a fail safe mode. If a power loss occurs, the lock opens. Note the location of the metal oxide varistor (MOV)
and the electromagnetic door lock.

MOV
(Schneider Electric #01-2020-095)

C
Electromagnetic Door Lock
(UL 1076 listed)

12 or 24 VDC

Configuring the SiteController
(NOTE: Check with your system administrator for assistance.)
1. Disable the DHCP Services on your PC.

6. Log on using the default Andover Continuum user name and
password.

2. Disconnect your computer from the network and set your IP
address to 169.254.1.2 and your subnet mask to 255.255.0.0.

7. Enter relevant configuration parameters on the WebServer
Configuration web pages.

3. Using a CAT5 cable (straight-through or crossover), connect
the PC Ethernet port to the SiteController Ethernet port.

8. After entering the parameters, click the Commit Changes/Restart
Controller button on the WebServer page. (Restore the PC, and
connect the SiteController to the network when it reboots.)

4. Run your web browser, then go to URL: http://169.254.1.1 to
display the Andover Continuum Embedded WebServer page in the
SiteController.

For more information, please see the online help topics in the controller’s embedded web pages or refer to SiteController cover.

5. Select Controller Configuration from the WebServer page.

Specifications
Dimensions
Open Class: 8.9”H x 10.3”W x 2.1”D (225H x 262W x 53D) mm
Small Enclosure: 14”H x 15”W x 3.25”D (356H x 381W x 82D)
mm
Medium Enclosure: 16”H x 22”W x 3.25”D (406H x 559W x 82D)
mm
Weight
Open Class: 2.0 lbs (.96 kg)
Small Enclosure: 11.0 lbs (6.09 kg)
Medium Enclosure: 16.0 lbs (8.35 kg)

Card Reader Type
Supports Wiegand swipe and proximity readers, and keypads that support
the Wiegand 8-bit burst format. Also supports ABA mag stripe readers.
Maximum Number of Bits per Card: 256
Card Reader Power
5 V @ 120mA, 12V @ 180 mA, fused, jumper-selectable per controller
Distance, Card Reader to Controller
500 ft. max. using 18-ga. wire; 200 ft. max. using 22-ga. wire

Enclosure Type
Open class; small or medium-size locked NEMA 1 enclosure with
tamper switch available

Door Switch Inputs
2, single or double resistor supervision. Useable as general-purpose digital
inputs

Operating Environment
Temperature: 32o to 120o F (0o to 49o C)
Humidity: 10 to 95% RH, non-condensing

Request-to-Exit Inputs
2, single or double resistor supervision. Useable as general-purpose digital
inputs

Power
115/230VAC, 50/60 Hz, 115VA consumption

Request-to-Exit Power
12V @ 100mA, 24V @100mA, fused, jumper-selectable

Peripheral Power
30W, 5V/12V/24V (included in consumption total), for readers and
locks

Universal Inputs
4; each may be configured as a Voltage, Thermistor, Digital, Counter or
Supervised input

Overload Protection
Fused with 1.5A 3AG fuse, 1500 volt transformer isolation. MOV
protected.

Voltage
Range: 0-5V
Resolution: 5 mV
Accuracy: +/- 15 mV (+/- 0.3% FSR)

Real Time Clock
Battery-backed by UPS
Battery Backup Operation
Full Operation for 1 hour (typical), can be programmed to switch to
CPU operation only (5 hours), or memory and clock backup only (7
days) using Schneider Electric battery P/N: 01-2100-423. Expandable by use of greater amp-hour batteries.

Thermistor
Type: 10K Ohm, Type III Thermistor
Range: -30o to 230o F (-34o to 110o C)
Resolution: 40o to 100o F (4o to 38o C) range; 0.20o F(0.11o C) typical
Accuracy: 40o to 100o F (4o to 38o C) range; +/- 1.0 o F (+/- 0.55o C)

Batteries
Qty 1, 12V/7.0 AHr lead-acid battery (included with enclosure
bundles)

Digital & Counter
Input Type: Contact Closure
Frequency: 4 Hz (max.)
Pulse Width: 125 ms (min.) (Digital pulse widths are based on Scan
Time.)

Battery Charging Circuit
Included in power supply, 3 days deep discharge recovery time,
fused

Supervised
Input Type: Single or Double Resistor Supervision, Parallel or Series
Circuit

Card Reader Inputs: 2

Specifications (continued)
Door Strike Relay Outputs
2 Form C relays, no override switches.
Usable as general-purpose digital outputs
Door Strike Power
12V @ 1A, 24V @ 300 mA per output, fused, jumper-selectable per
controller. Power can be interrupted by removing a jumper
Output Indication
LED’s
Digital Relay Outputs
2 Form C relays, with local override switches
Relay Contact Rating
3A@24VAC; 3A@30VDC
Ethernet LAN Interface
10/100 Ethernet twisted pair, RJ-45
Ethernet Distance
327 feet (100m) standard between 2 nodes using 10/100 base-T unshielded twisted pair cable. Standard Ethernet repeaters allow for longer
distances
Serial Comm. Interface
Port 1: RS-485 Infinet, maximum of 4 nodes. Includes service port.
Port 2: RS-232: Modem, printer, Plain English™ software interface (modem or printer provided by others). (No terminal interface)
Serial Comm. Speed
300 to 19.2K baud selectable
Infinet Bus (optional)
4,000 feet (1,220m) standard for Infinet using approved shielded, twisted
pair, low capacitance cable. Infilink module allows extension to longer
distances. 4 Infinet nodes maximum
SNMP
Standard: Node system information.
Optional: alarm information via SNMP Trap. Supports MIB level I
and II.
CX system information, alarms via SNMP TRAPs or direct polling, plus
MIB II data
Power
3-position barrier strip
Ethernet
RJ-45 connector for Ethernet
10/100 base-T
Infinet, Inputs, Outputs
Removable terminal strips
User Terminal, Modem
RJ-45 connector
Microprocessor
Motorola Coldfire, 32-bit, 66 MHz

Memory
SDRAM: 32MB; FLASH: 4MB
Storage
290,000 Card Records,
with 2,000 Events
Software Compatibility
CyberStation 1.53 or greater
Agency Listings
UL/CUL 916, FCC CFR 47 Part 15, EN55022, AS/NZS
3548, VCCI Class A, CE, Enclosure: UL 916 and CSA,
C22.2. No. 205-M198

Regulatory Notices
Federal Communications Commission
FCC Rules and Regulations CFR 47, Part 15, Class A
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
Complies with FCC Part 68 Rules (when optional modem is installed).
FCC Registration Number: AU7NMOIBMT5656R REN Number: 0.1B
Caution: The user that changes or makes modifications not expressly approved by Schneider Electric for compliance could void the user’s authority to operate the equipment.

Industry Canada
ICES-003
This is a Class A digital device that meets all requirements of the Canadian Interference Causing Equipment Regulations.

CE - Compliance to European Union (EU)
89/336/EEC - EMC Directive
This equipment complies with the rules of the Official Journal of the European Union specified in the EMC directive
89/336/EEC governing the Self Declaration of the CE Marking for the European Union.

C-Tick (Australian Communications Authority (ACA))
AS/NZS 3548
This equipment carries the C-Tick label and complies with EMC and radio communications regulations of the Australian Communications Authority (ACA), governing the Australian and New Zealand (AS/NZS) communities.

WEEE - Directive of the European Union (EU)
This equipment and its packaging carry the waste of electrical and electronic equipment (WEEE) label, in compliance with European Union (EU)
Directive 2002/96/EC, governing the disposal and recycling of electrical and electronic equipment in the European community.

US

C
58B2

UL 916 Listed product for the United States and Canada, Open Energy Management Equipment

Related Documentation
Document
Andover Continuum CyberStation Online Help

Document Number
N/A

Schneider Electric
One High Street
North Andover, MA 01845
(978) 975-9600
Fax: (978) 975-9782
http://www.schneider-electric.com/buildings



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2010:11:15 15:57:02-05:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2010:11:23 15:29:50-05:00
Metadata Date                   : 2010:11:23 15:29:50-05:00
Format                          : application/pdf
Creator                         : .
Title                           : CX9702 SiteController Installation Instructions
Document ID                     : uuid:195fd1cd-5cac-469a-9b73-6b412be7308c
Instance ID                     : uuid:9efc6874-4ad7-420c-84ee-157932ab48f3
Page Count                      : 12
Page Layout                     : SinglePage
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu