NUFLO Low Power Pre Amplifier Technical Data Sheet

User Manual: Pdf NUFLO Low Power Pre-Amplifier Technical Data Sheet Resource Library

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadNUFLO Low Power Pre-Amplifier Technical Data Sheet Nuflo-low-power-pre-amplifier
Open PDF In BrowserView PDF
TECHNICAL SPECIFICATIONS

NUFLO Low Power Pre-Amplifier
Cameron’s NUFLO™ turbine flow meters offer the
significant ability to provide remote readings. However,
noisy environments can cause erroneous or false readings
at remote terminals. The easily installed NUFLO low power
pre-amplifier helps solve the problem of noise when
shielded signal cables cannot effectively eliminate them.
Electrical noise can cause erroneous readings when the
noise level equals or exceeds the meter output signal
amplitude, which generally is very low (in millivolts). The
remote reading unit might also record noise as signal
output when the flow meter is not transmitting.
The low power pre-amplifier raises the turbine flow meter
signal level at the metering point to a relatively high
level signal (6 to 8 V). Thus, the receiver can discriminate
between signal and noise and register only true signals at
the remote location.
The flow meter transmits its low-level signal through a
pair of conductors to a remote reading unit. Shielded signal
cables can help keep noise out of this system or reduce the
noise level. However, a high noise level or the length of the
transmission cable can make shielding ineffective. The
pre-amplifier helps eliminate noise problems in these instances.

Advantages
•N
 o local power source is required. Power is supplied by the
remote reading unit over the same wires that conduct the
flow meter frequency.
• Low power consumption permits operation over virtually
unlimited transmission distances.
• Requires a single pair of wires between the pre-amplifier
and receiver.
• Suitable for use in most hazardous areas.
• Can be installed without special tools or equipment –
all parts have plug-in connectors or terminal screws.
• Directly compatible with signal receivers having
12 to 28 VDC power available.

Specifications
Housing:

• F eraloy® with copper-free aluminum cover, complete with
union for connection to turbine flow meter
Connections:

• 1” (25.4 mm) rigid conduit, female
Power Required:

• 12 to 28 VDC at 10 mA
Input Signal:

•2
 0 mv – 30 V at 5 Hz - 3000 Hz, adjustable input
sensitivity
Output:

•6
 to 8 V square wave across a 1000 ohm resistor with
12 V power supply at input signal frequency

Approvals
•N
 EC Class I, Groups C, D – Class II, Groups E, F, G –
Class III
• CSA Approved

L O C AT I O N S
North and South America
14450 JFK Blvd.
Houston, TX 77032
USA
Tel 1 281 582 9500
ms-us@c-a-m.com
Europe, Africa, Caspian and Russia
3 Steyning Way
Southern Cross Trading Estate
Bognor Regis
West Sussex PO22 9TT
England, UK
Tel 44 1243 826741
ms-uk@c-a-m.com
Asia Pacific
Suite 16.02 Menara AmFirst
No. 1 Jalan 19/3
46300 Petaling Jaya
Selangor Darul Ehsan
Malaysia
Tel 603 7954 0145
ms-kl@c-a-m.com

Power Supply Voltage

Resistor “R”

12 to 16 VDC

1000 ohm

18 to 22 VDC

1500 ohm

22 to 28 VDC

2200 ohm

Middle East
Level 9, Al Jazira Club Tower A
PO Box 47280, Muroor Road
Abu Dhabi
United Arab Emirates
Tel 971 2 596 8400
ms-uk@c-a-m.com
O th e r locations
ALGERIA
C A N A DA
CHINA
INDIA
M a l ay s i a
R U SS I A
UA E
UK
USA
www.c-a-m.com/measurement

© 2013 Cameron | NUFLO is a trademark of Cameron. All others are registered trademarks of their respective corporations. All Rights Reserved. | SWP 2M 12/13 AD01086M



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:01:13 10:38:25-06:00
Metadata Date                   : 2014:01:13 10:38:26-06:00
Modify Date                     : 2014:01:13 10:38:26-06:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:675a1ac3-d384-8a4a-a63e-6a1ff85a8e14
Original Document ID            : xmp.did:0480117407206811822A95473FED6B20
Document ID                     : xmp.id:400F4EB10A2468118C14ACF0DF7A6145
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:370F4EB10A2468118C14ACF0DF7A6145
Derived From Document ID        : xmp.did:5E782583332168118C14A7E1A9230420
Derived From Original Document ID: xmp.did:0480117407206811822A95473FED6B20
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2014:01:13 10:38:25-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools