Logical Systems”, LLC, hereinafter Company “LogiS” warrants that for a period of
24 months from the delivery date to the original purchaser this product will be free from defects
in materials and workmanship. EXCEPT FOR THE FOREGOING LIMITED WARRANTY,
COMPANY “LOGIS” DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
“LogiS’s” obligation is limited to repairing or replacing parts or equipment which are returned to
“LogiS”.
“LOGIS” ASSUMES NO LIABILITY FOR ANY DIRECT, INDIRECT, SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES, CAUSED BY PROPER
OR IMPROPER OPERATION OF ITS EQUIPMENT, WHETHER OR NOT DEFECTIVE.
Before returning any equipment to “LogiS”, a Return Material Authorization (RMA) number
must be obtained. Please call the “LogiS” Customer Service Manager who will assign an RMA
number. Be sure to have the serial number of the unit available.
FCC Class B Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. this device may not cause harmful interference,
2. this device may accept any interference received, including interference that may cause
undesired operation
Warning: changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment or residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if the user uses it not in accordance with the “User’s manual”, may cause
harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation

CONTACTS:
tel./fax: (+7 495) 641-2-641 (multichannel)
e-mail: info@geotech.ru
Address: 5, Entuziastov St.,Bldg.39, Moscow, 111024, Russia
Working hours: during working days, 9.00-18.00

1

1. General Safety Instructions and Certification
When using the device as intended, it is a bad practice to point its work surface toward
people. The level of device radiation power is not detrimental to man's health. The operation
safety subject to normal location of the device, i.e. the device is oriented to test medium, is
confirmed
by
sanitary
and
epidemiological
inspection
report
No.
50.99.04.431.П.008785.07.07 of 03.07.2007 of the Directorate of Federal Service for
Surveillance in the Sphere of Consumer Rights Protection and Human Wellbeing for
Moscow region.
Safety Instructions When Working with BP-9/12 Power Supply Unit:
· Do not use and do not charge the power supply unit with damage symptoms: deformation,
leakage of the battery electrolyte.
· Do not open the power supply unit.
· Do not immerse the power supply unit into water.
· Charge the power supply unit only with dedicated charging unit.
To avoid injury and device damage, observe the following precautions:
Avoid slamming and mechanical damages during device use and transportation.
Only trained personnel and the one familiar with Operation Manual is allowed to operate
the device.
Maintenance procedures of the device can be performed only by skilled personnel.
Partial or complete disassembly of device is prohibited to avoid electric shock.
Avoid contacting bare spots of wiring when operating the device. Do not touch uninsulated
connections and live components.
Do not repair the device by yourself to prevent its damage.
It is prohibited to immerse the devices or its parts into water or other fluids.

2. Purpose
Radar Detector (RD-400) is portable radio detection system designed to locate survivors
buried under rubble or debris by either movement or breathing.

3. Set of RD-400 Radar-Detector
The RD-400 set consists of:
1. RD-400 Radar Detector
2. BP-9-12 power supply unit
3. ZU-9 charger
4. Rugged tablet PC
5. Charger for tablet PC
6. Radio modem unit
7. Documentation (Operation Manual, Certificate)
8. GeoScan32 software, base version (installation CD).
Outside view of RD-400 radar detection device is shown in Fig. 3.1.

2

Tablet PC
B-9/12 power
supply unit
Set of chargers
Wi-Fi unit

Radio
detection
device

Figure 3.1. RD-400 Radar-Detector

4. Preparation and sounding
The operation and selection of sounding parameters of the device is controlled by the
software installed in tablet PC included in the device set. Transition of control commands,
data exchange between RD-400 and tablet PC is carried out via WI-Fi channel, which
automatically switches on at RD-400 power up, and in the tablet PC – after the program
start-up.
Operation procedure of RD-400 radio detection device:
1. Switch on power supply by pressing the button of BP-9-12 power supply unit to “On”
position.
2. Place the radio detection device on the surface of a medium to be analyzed. Emission of
sounding radio signals is pointed toward the case bottom (the side opposite to cover of
the case) having protective rubber legs.
3. Switch on tablet PC. Select tag
finger.

on the PC Desktop and tap on it twice with your

3

Tag of RD-400
program

Figure 4.1. Icon of RD-400 control program on the PC Desktop
4. Window shown in Figure 4.2 will display on screen of tablet PC after the program start.
The “Search of AB” caption appearing at first moment means the process of establishment
of connection between RD-400 and tablet PC; the caption goes out when connection is
established.
Charge state of tablet PC battery
6

1

7
2
8
3

9

4
10
5
Scale of distances to detected object

11
12

Figure 4.2. Main window of radio detector device program
Assignment of control buttons of main window of RD-400 control program
1. selection and adjustment of sounding parameters;
2. saving of tablet PC screen image;
3. folder with saved files of soundings and screenshots;
4. temporal suspension of image on the screen;
5. actuation of the sounding results saving mode;
4

6. selection of sounding distance;
7. selection of time span for reflected signals spectrum analysis;
8. selection of sounding medium;
9. setting of distance at which detection of objects does not take place;
10. change of device sensitivity;
11. selection of a form of mapping of sounding results on the screen;
12. zone of the reflected signal spectrum presentation.
5. Further, the radio detector device switches over to data analysis mode (Figure 4.3). Zone
of the reflected signal spectrum presentation goes into the analysis time indication mode
, and the filling time of this zone corresponds to the time of analysis. There is an additional caption,
which shows up in the same zone: “Please wait. Data under acquisition»

Figure 4.3. Main window of radio detector device program
After data analysis, in case of the object detection by its breathing the program window will be as
shown in Figure 4.4. Cryptogram with the image of a man appears on the screen supplied with
distance to object detected by its breathing. Additionally the spectrum of reflected signal from the
object detected by its breathing and position of hardware threshold of the device (red line) starts
displaying in the right side of the main window. The form of spectrum of reflected signal extends
the operator’s capabilities in forecasting and estimating the situation on the likely presence of
breathing object under the obstruction. Appearance of a pronounced peak in the spectrum refers
to the object detection by its breathing. Moving the line that corresponds to the hardware threshold
using “+” and “-” buttons allows to set up most comfortably the size of spectrum of reflected
signal.

5

Spectrum of reflected signal
from the breathing object

Location of
hardware
threshold

Indication of object detection
by its breathing

Figure 4.4. View of window of radio detection device program in case of living object
detection by its breathing
Apart from the view seen in Figure 4.4, the RD-400 program displays the results of sounding as
shown in Figure 4.5, which is switched over by “Change view” button (Figure 4.2, item 11).
Radargram is displayed in the left part of the screen.
In case of the object detection by its breathing, a blue line located relative to the scale of distances
according to the distance from the radio detection device to the detected object is drawn on the
radargram.

Indication of object detection
by its breathing

Figure 4.5. View of window of radio detector device program with display of radargram
and graphical image at detection of living object by its breathing
To enhance efficiency of RD-400 radio detector device application, the program provides a series
of options, which function and use are described below. Calling up of required option is performed
6

by pressing of relevant button.
“Configuration” option (Figure 4.6) allows:
· selecting the language (English, Chinese) of captions in main window of RD-400 program.
· configure settings of device manufacturer (“Factory settings”).

Figure 4.6. “Settings” menu of RD-400 radio detector device program
“Distance” option - meant for selection of sounding distance of RD-400 radio detection device (3
m, 7 m, 15 m, and 30 m) Figure 4.7.

Figure 4.7. “Distance” option of RD-400 radio detection device program
“Time of analysis” option - meant to set up time period (Figure 4.8), during which the program
analyses spectrum of reflected signals. Range of analysis time variation is 15, 30, 60, and 120 s.
In the course of prospecting works under rough conditions, it is necessary to increase the time of
analysis to 60-120 s.
7

Figure 4.8. “Time of analysis” option of RD-400 radio detection device program
“Blind zone” option - meant to adjust distance value (Figure 4.9) in a close zone of device in order
to decrease probability of false detections. The size of “Blind zone” changes to a distance of 1.0
m with a step of 10 cm, further on the step of change is 0.5 m. The main program window area of
“Blind zone” gets filled with green transparent color.
Button of zone increase

Display of size of
“Blind zone”

Button of zone decrease

Figure 4.9. “Blind zone” option of RD-400 radio detection device program

“Sensitivity” option - meant to change the device sensitivity (Figure 4.10) at detection of objects
by their breathing. There are eight grades of sensitivity in the program from 1 to 8; 8 stands for
the highest sensitivity. Button “+” increases sensitivity of the device, and button “-” decreases it;
additionally a numeric value displays the grade of sensitivity. Increase of sensitivity at sounding
of medium which is not complex by its electrophysical properties leads to rise of false random
8

detections.

Figure 4.10. “Sensitivity” option of RD-400 radio detection device program
“Medium” option - is selected (Figure 4.11) depending on nature of medium, which the sounding
penetrates (concrete, air, snow). Selection of medium affects the correctness of determination of a
distance from the radio detection device to an object detected by its breathing

Figure 4.11. “Medium” option of RD-400 radio detection device program
RD-400 radio detection device detects the objects not only by their breathing, but also by their
motion. The window of device program can be presented in two forms (Figures 4-12 to 4.13). In
the first case, detection of a mobile object is displayed in the form of the “walking
man”cryptogram, which moves on the screen in parallel to the scale of distances depending on
change of distance from the device to the detected moving object. In the second case, radargram
is supplemented, on which the motion trajectory of detected object moves relative to the device.

9

Figure 4.12. View of window of radio detection device program with display of results in
the form of a moving object

Motion-based indication
of object detection

Figure 4.13. View of window of radio detection device program with display of results in
graphical mode and radargram at motion-based detection of a living object

5. Charging the power supply unit
Before start of the charging procedure, it is necessary to unplug connector (item 1 Figure 4.1) from
the power supply unit.

10

1
2

Figure 5.1. Upper panel of RD-400 radio detection device
Sequence of BP-9/12 power supply unit charging:
1. Connect ZU-9 charger to 220V, 50Hz mains.
2. Switch on power supply unit.
3. Connect charger to the power supply unit.
4. Prior to charging, the red LED flashes (test phase) over 2-3 seconds, then it stays lit. Charging
of completely discharged power supply unit takes not more than 10 hours.
5. When green LED lights up, disconnect the charger and power supply unit in reverse order.
If it is necessary to completely disconnect BP-9/12 power supply unit from the radio detection
device, perform the following steps:
1. Disconnect the connector, item 1 (Figure 4.1)
2. Unscrew the screw, item 2 (Figure 4.1).

11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2017:01:23 12:45:21Z
Modify Date                     : 2017:01:23 15:51:11+03:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Metadata Date                   : 2017:01:23 15:51:11+03:00
Producer                        : PDF Complete 4.1.49.2002
Format                          : application/pdf
Title                           : Microsoft Word - USer manual RD-400
Document ID                     : uuid:72da6d75-c232-4958-a152-9e2aa244aaca
Instance ID                     : uuid:615b4f52-0360-47e1-b5ec-d89e29a4baea
Page Count                      : 12
EXIF Metadata provided by EXIF.tools

Navigation menu