Peak System Technik Pcan Dongle Ipeh 002015 Users Manual (ISO)
2015-02-06
: Peak-System-Technik Peak-System-Technik-Pcan-Dongle-Ipeh-002015-Users-Manual-517509 peak-system-technik-pcan-dongle-ipeh-002015-users-manual-517509 peak-system-technik pdf
Open the PDF directly: View PDF .
Page Count: 23
Download | |
Open PDF In Browser | View PDF |
PCAN-Dongle (ISO) Adapter PC Parallel Port to High-speed CAN User Manual PCAN-Dongle (ISO) – User Manual Products taken into account Product Name Model Item Number PCAN-Dongle PS/2 IPEH-002019 PCAN-Dongle ISO PS/2 IPEH-002020 PCAN-Dongle DIN IPEH-002015 Windows® and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries. All other product names mentioned herein may be the trademarks or registered trademarks of their respective companies. Furthermore, "™" and "®" are not mentioned in each case in this manual. © 2006 PEAK-System Technik GmbH PEAK-System Technik GmbH Otto-Roehm-Strasse 69 D-64293 Darmstadt Germany Phone: +49 (0)6151-8173-20 Fax: +49 (0)6151-8173-29 www.peak-system.com info@peak-system.com Release date: May 3, 2006 2 PCAN-Dongle (ISO) – User Manual Contents 1 1.1 1.2 1.3 2 2.1 2.2 2.3 3 3.1 3.2 4 4.1 4.2 Introduction 4 Properties at a Glance System Requirements Scope of Supply Hardware Installation 4 5 5 6 Connecting to the PC Connecting a HS-CAN 5-Volt Supply at the CAN Connector Software Setup 6 7 7 10 Windows Operating Systems DOS and Relatives Use 10 11 12 Getting Started under Windows Getting Started under DOS 13 15 5 Linking Own Programs with PCAN-Light 18 6 Frequently Asked Questions (FAQ) 19 7 Technical Specifications 20 Appendix A A.1 Certificates 21 CE Appendix B 21 Quick Reference 3 23 PCAN-Dongle (ISO) – User Manual 1 Introduction Tip: At the end of this manual (Appendix B) you can find a Quick Reference with brief information about the installation and operation of the PCAN-Dongle. The PCAN-Dongle allows the connection of a CAN bus to the parallel interface of an IBM compatible PC. It is especially suitable for use with notebook computers since these usually don't have an ISA or PCI slot. With the help of this adapter any PC can be linked to a High-speed CAN (HS-CAN). The so-called ISO version of the PCAN-Dongle additionally contains a galvanic isolation. An isolation of up to 500 V between the PC and the CAN parts of the adapter is achieved by use of a DC/DC converter and an optocoupler. Note: This manual refers to both the PCAN-Dongle standard version and the PCAN-Dongle ISO with galvanic isolation. Differences at use and at the technical specifications are mentioned accordingly in this manual. 1.1 Properties at a Glance Connection of a High-speed CAN (CAN specifications 2.0A and 2.0B) to a PC Use of a PC’s parallel port capable of interrupts Supports all interrupt and port address settings for the parallel interface Supports the standard and the ECP mode of a parallel interface Equipped with the CAN controller SJA1000T by Philips CAN transfer rate up to 1 MBit/s 4 PCAN-Dongle (ISO) – User Manual CAN connection 9-pin Sub-D male, pin assignment according to CiA recommendation DS102 Galvanic isolation up to 500 V for the CAN interface (only PCANDongle ISO) Power supply (5 V) via cable with T-piece for keyboard connector (DIN or PS/2) Support for operating systems Windows (98 SE, ME, 2000 SP4, XP), Linux, and DOS Note: This manual describes the use of the PCAN-Dongle with Windows and DOS. You can find device drivers for Linux and the corresponding information on PEAK-System's website under http://www.peak-system.com/linux. 1.2 System Requirements The following prerequisites must be given, so that the PCAN-Dongle can be used properly: An empty parallel port (Sub-D, 25 pins) at the PC, capable of interrupts Operating system Windows (98 SE, ME, 2000 SP4, XP), Linux, or DOS 1.3 Scope of Supply The scope of supply normally consists of the following parts: Adapter PCAN-Dongle (case with two ports and a cable with Tpiece for DIN or PS/2 keyboard connector) CD-ROM with software (drivers, utilities), programming examples, and documentation 5 PCAN-Dongle (ISO) – User Manual 2 Hardware Installation 2.1 Connecting to the PC 1. Make sure that the PC is turned off. 2. Connect the PCAN-Dongle with the wider port (25 pins) to the free parallel port at the PC. 3. Pull the keyboard connector from the corresponding port at the PC. 4. Connect the T-piece at the cable of the PCAN-Dongle to the keyboard port. 5. Now reconnect the keyboard to the free end of the T-piece. A configuration of the hardware is not needed. However, you should check the settings for the parallel interface in the PC's BIOS setup. If the PC has a parallel interface with EPP as well as ECP properties, the corresponding setting in the BIOS set-up should be "ECP" (not "EPP" and not "EPP+ECP"). Although the extended properties of the PCAN-Dongle usually will work with the last-mentioned setting some systems may have problems with it. Therefore the setting for the "pure" ECP mode should be preferred. Further information about the different operating modes of the PCAN-Dongle can be found in chapter 4 Use. 6 PCAN-Dongle (ISO) – User Manual First Test After turning on the PC the red LED at the PCAN-Dongle must be permanently on. This indicates that the power supply for the PCANDongle is correct. Attention! Don't remove PCAN-Dongle from the PC while powered on (red LED on PCAN-Dongle is lit). Electronic parts of the PCAN-Dongle or the PC's parallel interface may be harmed. 2.2 Connecting a HS-CAN A CAN is connected to the 9-pin Sub-D port on the PCAN-Dongle. The pin assignment corresponds to the CiA recommendation DS 102-1. Figure 1: Pin assignment HS-CAN (view onto male connector of the PCAN-Dongle) 2.3 5-Volt Supply at the CAN Connector A 5-Volt supply can optionally be routed to pin 1 and/or pin 9 of the CAN connector (PCAN-Dongle ISO: pin 1 only) by setting solder bridges on the PCAN-Dongle PCB (Dongle case opened). Thus devices with low power consumption (external transceivers or optocouplers, for example) can be directly supplied via the CAN connector. 7 PCAN-Dongle (ISO) – User Manual When using this option, the 5-Volt supply is directly connected to the power supply of the PCAN-Dongle (coming from the PC) and is not fused separately. The ISO version of the Dongle contains an interconnected DC/DC converter. Therefore the current output is limited to about 50 mA. Attention! At this procedure a special care is indispensable since there is a short circuit danger. The PCAN-Dongle could be destroyed and/or the power supply or electronics of the PC or other components connected could be damaged. Important note: PEAK-System Technik GmbH does not give guarantee on damages which have resulted from application of the option described in this section. Procedure: 1. In order to access the PCB, open the case of the PCANDongle by cautiously levering the latches on both sides (risk of breakage!), e.g. with a flat tip screwdriver. 2. Set the solder bridges on the PCAN-Dongle PCB according to the desired settings. Figure 2 and Figure 3 show the possible positions of a solder bridge. 8 PCAN-Dongle (ISO) – User Manual +5 Volts at the CAN connector: Figure 2: PCB PCAN-Dongle (bottom side): JP9, 2-1 (as shown) → pin 1 JP9, 2-3 → pin 9 Figure 3: PCB PCAN-Dongle ISO (top side): Pos. R11 bridged → pin 1 3. For reassembly place the PCB overhead onto the top part of the case. Make sure that the cable is lying in the side cut-out with the strain relief inside the case, and that the LED is placed in the corresponding hole of the top part of the case. 4. Push the bottom part of the case onto the top part (the latches click in). 9 PCAN-Dongle (ISO) – User Manual 3 Software Setup This chapter describes the installation of the delivered software. You get to know more about its use in the following chapter 4. 3.1 Windows Operating Systems Under Windows a driver is needed that can access the PCANDongle and that provides the interface for Windows software. Beside the mentioned device driver the CAN monitor PCAN-View for Windows can also set up. Note: The following instructions are valid only for Windows 2000 and Windows XP. If you use the operating systems Windows 98 SE or Windows ME, please contact the customer support (address: see page 2). Do the following to setup the driver and, if applicable, additional software: 1. Please make sure that you are logged in as user with administrator privileges (not needed for normal use of the PCAN-Dongle later on). 2. Insert the supplied CD-ROM into the PC. Usually a navigation program appears a few moments later. If not, start the file Intro.exe from the root directory of the CDROM. 3. Navigate through the menus to the driver installation for the PCAN-Dongle (English > Drivers > PCAN-Dongle). Click on Install now afterwards. The setup program for the driver is executed. 4. Follow the instructions of the setup program. 10 PCAN-Dongle (ISO) – User Manual 3.2 DOS and Relatives You can find the CAN monitor PCAN-View for DOS and the programming samples in C and Pascal on the supplied CD-ROM in the following directories: PCAN-View for DOS: \Tools\PcanView\Dos Programming samples: \Develop\Dos\Dongle A separate setup procedure isn't needed. 11 PCAN-Dongle (ISO) – User Manual 4 Use The PCAN-Dongle can be used in one of four possible operating modes: Name of Operating Mode Alternative Identifier Description Multiplex Mode PEAK DongleCAN Standard Parallel Port (SPP) EPP Mode PEAK DongleCAN EPP Extended Capability Port (ECP) Multiplex PeliCAN PEAK DongleMode CAN SJA Standard Parallel Port (SPP), extended CAN functionality (CAN 2.0B incl. 29-bit IDs) EPP PeliCAN Mode Extended Capability Port (ECP), extended CAN functionality (CAN 2.0B incl. 29-bit IDs) PEAK DongleCAN SJA EPP The EPP PeliCAN Mode is recommended to gain the full CAN functionality at lowest possible PC system load. If this mode doesn't work correctly, you can fall back to one of the other operating modes. The Multiplex Mode should work on any system. Tip: You can find further information about the PeliCAN Mode in the data sheet for the CAN controller SJA1000 by Philips obtainable at the according website, for example. You can find information about activating an operating mode in the following sections. 12 PCAN-Dongle (ISO) – User Manual 4.1 4.1.1 Getting Started under Windows Information about the Parallel Interface You need information about the used interrupt and port address of the parallel interface. It can be gained from the Device Manager of Windows: 1. On the desktop open the context menu of the icon "My Computer" (right mouse click) and select the command Properties. 2. Windows 2000, XP: Select the tab Hardware and click on the button Device Manager afterwards. Windows 98 SE, ME: Select the tab Device Manager. 3. Under Ports (COM & LPT) in the tree view double click on the entry Printer Port (LPTx) or ECP Printer Port (LPTx). 4. Select the tab Resources. You can extract the needed information from the entries "Input/Output Range" and "Interrupt Request" in the shown list. Write down this information for later use. Note: Under Windows 2000 and Windows XP the use of an interrupt for the parallel interface must explicitly be determined. This happens on the tab Port Settings. Activate the option Use any interrupt assigned to the port there. 4.1.2 PCAN-View for Windows In the Start menu of the Windows desktop you can find the entry "PCAN Hardware". From there you can execute the program PCANView. A dialog for the selection of the CAN hardware as well as the setting of the CAN parameters appears after the program start. 13 PCAN-Dongle (ISO) – User Manual Figure 4: Selection of the CAN specific parameters If no entry is in the list "Available CAN hardware" (for example at the first program start), you need to add one: 1. Press the button Add. The dialog box "Add CAN hardware" appears. 2. Select the connected hardware and the operating mode from the list "Type of CAN hardware". If the mode of the parallel interface is set to ECP in the PC's BIOS setup, you can register the PCAN-Dongle as "PEAK Dongle-CAN SJA EPP". 14 PCAN-Dongle (ISO) – User Manual Figure 5: Selection of hardware resources 3. Enter the port address and the interrupt of the used parallel interface established before (see section above). 4. Confirm your input with OK. In the dialog box "Connect to CAN hardware" make further settings (baud rate and CAN message filter) for the created hardware entry. If you need further help after the program start, use the online help provided with the program (key [F1]). 4.2 4.2.1 Getting Started under DOS Information about the Parallel Interface You need information about the used interrupt and port address of the parallel interface. It can be determined with the MS-DOS tool MSD (MSD.EXE in the DOS directory). The following table gives an overview of the common port addresses and interrupts for the parallel port at the PC. 15 PCAN-Dongle (ISO) – User Manual Port Address Interrupt LPT1 0x378 IRQ7 LPT2 0x278 IRQ5 LPT3 0x3BC IRQ5/7 4.2.2 PCAN-View for DOS The program PCAN-View for DOS enclosed in the package is a CAN monitor that supports various SJA1000/82C200 based PC hardware extensions by PEAK-System. It is able to transmit and receive CAN messages. As software with basic features it represents the Light version of CANMON for DOS. With PCAN-View for DOS you can examine existing nets and set up new ones. Note: On PCs with processors with a clock frequency greater than 400 MHz you should only use program versions > 3.0. Program Initialization 1. Execute PCAN-View for DOS (file PCANVIEW.EXE). 2. Enter the port address and the interrupt of the parallel interface. 3. Select the desired baud rate. 4. From the list of operating modes select one of those beginning with "PEAK Dongle". If your PC has an ECP interface and the corresponding function is activated in the BIOS setup, you can use one of the operating modes ending with "EPP". If you have problems with these operating modes, select "PEAK DongleCAN" instead. 5. By pressing [F10] the PCAN-Dongle is configured and linked to the CAN. 16 PCAN-Dongle (ISO) – User Manual If the error message "CAN Controller 82C200 not found" is displayed, then double-check the used interrupt and port address as well as the selected hardware type. You can access the online help any time by pressing [F1]. Figure 6: Screenshot PCAN-View for DOS 17 PCAN-Dongle (ISO) – User Manual 5 Linking Own Programs with PCAN-Light On the supplied CD-ROM you can find files that are provided for software development. You can access them with the navigation program (button Programming). The files exclusively serve the linking of own programs to hardware by PEAK-System with the help of the installed device driver under Windows. Further more the CD-ROM contains header files and examples for creating own applications in conjunction with the Light drivers. Please read the detailed documentation of the interface (API) in each header file. Tip: You can find further information in the file PCANLight_enu.chm (Windows Help file) on the CD-ROM. Notes about the License Device drivers, the interface DLL and further files needed for linking are property of the PEAK-System Technik GmbH (PEAK-System) and may be used only in connection with a hardware component purchased from PEAK-System or one of its partners. If a CAN hardware component of third party suppliers should be compatible to one of PEAK-System, then you are not allowed to use or to pass on the driver software of PEAK-System. PEAK-System assumes no liability and no support for the PCANLight driver software and the necessary interface files. If third party suppliers develop software based on the PCAN Light driver and problems occur during use of this software, please, consult the software provider. To obtain development support, you need to own a PCAN Developer or PCAN Evaluation version. 18 PCAN-Dongle (ISO) – User Manual 6 Frequently Asked Questions (FAQ) Question Answer In the PC's BIOS setup the parallel port setting shows ECP but the PCAN-Dongle works with the EPP mode. Is this correct? Yes, it is. The naming of the operating mode EPP of the PCANDongle has historical causes. The parallel interface at the PC went through various developments in the nineties. Only the EPP extension existed during the time, when the PCAN-Dongle arose. With version 1.9 the EPP extension already had similarities to the ECP extension, which is usually used in PCs today. The name of the operating mode EPP was kept for the PCAN-Dongle. Can a printer still be connected to the PCANDongle? No. The PCAN-Dongle doesn't offer any possibility to connect through the parallel interface for the printer. The PCAN-Dongle Pro, having this functionality integrated, isn't sold by PEAK-System anymore. Is it possible to supply the Yes. PCAN-Dongle PS/2 also via the computer's mouse connector? I have problems running the PCAN-Dongle under Windows 2000/XP. The driver files PEAKCAN.SYS and PCAN_DNG.SYS must be available at least in version 2.30. You can determine the currently used driver version e.g. with the About dialog box in PCAN-View (menu command Help | About). 19 PCAN-Dongle (ISO) – User Manual 7 Technical Specifications Supply Supply voltage +5 V DC Current consumption max. 80 mA, PCAN-Dongle ISO max. 140 mA Connectors Supply Cable to the keyboard jack of the PC, length about 50 cm/20 inches PC Sub-D (m), 25 pins (to standard parallel port) CAN Sub-D (m), 9 pins Pin assignment according to CiA recommendation DS 102-1 PCAN-Dongle ISO: galvanic isolation up to 500 V CAN Specification ISO 11898 High-speed CAN (up to 1 MBit/s) 2.0A (standard format) and 2.0B (extended format) Controller Philips SJA1000T Transceiver Philips PCA82C251 Environment Operating temperature 0 – 60 °C (32 – 140 °F) Storage temperature -20 – +80 °C (-4 – 176 °F) Relative humidity 15 – 90 %, not condensing EMC EN 61000-6-3:2001 EN 61000-6-1:2001 EN 61000-6-4:2001 (only PCAN-Dongle ISO) EN 61000-6-2:2001 (only PCAN-Dongle ISO) EC directive 89/336/EEC Measures Size 56 x 18 x 62 mm 2 3/16 x 11/16 x 2 7/16 Inches Weight max. 70 g (2.5 oz.) Design and specifications are subject to change without notice. 20 PCAN-Dongle (ISO) – User Manual Appendix A A.1 Certificates CE 21 PCAN-Dongle (ISO) – User Manual 22 PCAN-Dongle (ISO) – User Manual Appendix B Quick Reference Hardware Installation Connect the PCAN-Dongle to the PC's parallel port, insert the Tpiece at the cable's end between the keyboard port at the PC and the keyboard connector (for power supply). When the PC is turned on, the red LED indicates an existing power supply. Software installation and startup under Windows Execute the driver installation program from the supplied CD-ROM. Restart Windows after the installation procedure. Run the CAN monitor PCAN-View for Windows from the Start menu as a sample application for accessing the PCAN-Dongle. Get the parameters of the parallel interface (I/O address, interrupt) needed for initialization of the PCAN-Dongle from Windows' Device Manager. HS-CAN connector (Sub-D, 9 pins) 23
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Modify Date : 2006:05:03 14:58:13+02:00 Subject : User Manual Create Date : 2006:05:03 12:54:56Z Page Count : 23 Creation Date : 2006:05:03 12:54:56Z Mod Date : 2006:05:03 14:58:13+02:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : PEAK-System Technik GmbH Metadata Date : 2006:05:03 14:58:13+02:00 Creator : PEAK-System Technik GmbH Title : PCAN-Dongle (ISO) Description : User Manual Page Mode : UseOutlines Tagged PDF : YesEXIF Metadata provided by EXIF.tools