Peiker acustic and KG V1140-101 GSM/GPRS/UMTS/HSDPA/HSUPA/LTE Module User Manual LTE NAD UserManual v09
Peiker acustic GmbH & Co. KG GSM/GPRS/UMTS/HSDPA/HSUPA/LTE Module LTE NAD UserManual v09
Contents
- 1. 12_LTE-NAD_UserManual_v06
- 2. LTE_NAD_UserManual_v09
LTE_NAD_UserManual_v09
User manual LTE-NAD V1140-xxx Peiker product ID: 2189-140-xxx-00 (V1140-xxx) Revision: Date: 0.9 June 2014 Status: Draft _______________________________________________________________________________________________________________ Seite 1 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe History: Date Revision 15.09.2013 0.5 13.12.2013 0.6 16.12.2013 0.7 01.04.2014 0.8 17.06.2014 0.9 Name Comment wlo Initial document phse Some additions to sections 2.1 and 3.3 Some corrections to section 2.2, Figure 4 updated phse Some additions to section 8 phse Modifications/additions to section 8 phse Updated Max Antenna Gain Values in section 8.3 _______________________________________________________________________________________________________________ Seite 2 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Content Introduction ..........................................................................................................................................4 1.1 Scope ..................................................................................................................................................4 1.2 Audience ............................................................................................................................................4 1.3 Contact information, Support .........................................................................................................4 1.4 Related Documents ..........................................................................................................................4 2 Overview ...............................................................................................................................................5 2.1 Product Variants................................................................................................................................ 5 2.2 Features .............................................................................................................................................6 2.3 Approvals ...........................................................................................................................................6 3 Overview ...............................................................................................................................................7 3.1 HW Features ......................................................................................................................................7 3.2 Connectors .........................................................................................................................................7 3.2.1 Module Signal and RF Connectors ..........................................................................................7 3.2.2 Ground and Heat Dissipation Connectors..............................................................................7 3.3 Main Interfaces .................................................................................................................................7 3.3.1 USB ..............................................................................................................................................7 3.3.2 SIM Interface ............................................................................................................................. 8 3.3.3 Power on.....................................................................................................................................8 3.3.4 Reset ...........................................................................................................................................8 3.3.5 GPIOs ..........................................................................................................................................8 3.3.6 GSBIs...........................................................................................................................................9 3.3.7 Module Pin-out......................................................................................................................... 10 3.4 Supply Voltage ................................................................................................................................ 14 3.5 Power Consumption .......................................................................................................................14 3.6 Transmitter ......................................................................................................................................15 3.7 Receiver ...........................................................................................................................................15 3.8 Environmental Specification ..........................................................................................................15 3.8.1 Temperature Range ................................................................................................................15 4 Evaluation Kit .....................................................................................................................................16 5 AT Command interface .....................................................................................................................19 6 Safety Recommendations according to EN60950-1 .....................................................................21 7 List of Acronyms ................................................................................................................................ 22 8 Regulatory Certifications ..................................................................................................................23 8.1 USA (FCC) ............................................................................................................................................23 _______________________________________________________________________________________________________________ Seite 3 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 1 Introduction 1.1 Scope This document gives an overview about electrical, mechanical and functional detail of the peiker LTENAD v1140-xxx. 1.2 Audience Information to integrate the module in other applications. 1.3 Contact information, Support peiker acustic GmbH & Co KG Max-Planck Street 32 D-61381 Friedrichsdorf / Ts. Germany http://www.peiker.de info@peiker.de 1.4 Related Documents None. _______________________________________________________________________________________________________________ Seite 4 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 2 Overview 2.1 Product Variants The LTE-NAD is available in multiple product variants: Peiker product # 2189-140-100-00 (V1140-100) 2189-140-101-00 (V1140-101) 2189-140-103-00 (V1140-103) 2189-140-104-00 (V1140-104) 2189-140-105-00 (V1140-105) 2189-140-106-00 (V1140-106) Module configuration LTE EU configuration LTE North America configuration 2G/3G EU/RoW configuration LTE Asia Pacific configuration 2G/3G North America configuration 2G/3G China configuration All variants include Quad band GSM/GPRS/EDGE (850, 900, 1800, 1900 MHz) V1140-100 LTE Bands WCDMA Bands B3, B7, B20 FDD1, FDD8 V1140-101 LTE Bands WCDMA Bands B2, B4, B5, B17 FDD2, FDD5 V1140-103 LTE Bands WCDMA Bands No LTE support FDD1, FDD2, FDD5, FDD6, FDD8 V1140-104 LTE Bands WCDMA Bands B1, B3, B5, B7, B19 FDD1, FDD5, FDD6, FDD8 V1140-105 LTE Bands WCDMA Bands No LTE support FDD2, FDD5 V1140-106 LTE Bands WCDMA Bands No LTE support FDD1 _______________________________________________________________________________________________________________ Seite 5 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 2.2 Features Features Same footprint and pin-out for all modules Voice and data calls are supported in all modules GSM (R99, GPRS and EDGE) for all modules WCDMA (R99, R5 HSDPA, R6 HSUPA and R7 HSPA+) for all modules WCDMA (R8 DC-HSPA+) for all modules except for V1140-101 and V1140-105 LTE (Rel.9 Cat3 FDD) for LTE capable modules DTM/eDTM eCall inband modem Standalone GPS, GLONASS, AGPS (MS-Assisted and MS-Based) Data rates - GSM: DL/UL – 14.4kbps / 14.4kbps GPRS: Multislot class 12, DL/UL – 85.6kbps / 42.8kbps EDGE: Multislot class 12, DL/UL – 236.8kbps / 118.4kbps - WCDMA: DL/UL up to 384kbps HSPA+: Category 24 in DL using 64 QAM and Dual-Cell; Up to 42 Mbps – Not supported by V1140-101 and V1140-105 Category 14 in DL using 64 QAM; Up to 21 Mbps Category 6 in UL using 16 QAM; Up to 5.76 Mbps - LTE-FDD Category 3: Up to 100 Mbps in DL, up to 50 Mbps in UL Power Classes LTE: All supported bands, Power Class 3 WCDMA: All supported bands, Power Class 3 EDGE: 850 MHz / 900 MHz / 1800 MHz/ 1900MHz, Power Class E2 GSM / GPRS: 850 MHz / 900MHz, Power Class 4 GSM / GPRS: 1800 MHz / 1900MHz, Power Class 1 Dimension and Weight Dimensions: 31mm x 46mm x 4mm Weight < 10 grams 2.3 Approvals R&TTE directive CE, GCF FCC, IC, PTCRB AT&T _______________________________________________________________________________________________________________ Seite 6 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 3 Overview 3.1 HW Features Qualcomm SoC (system on chip) o LTE capable modules V1140-100, V1140-101 and V1140-104 MDM9215 Baseband / PMIC8018 Power management / WTR1605L o Non-LTE modules V1140-103, V1140-105 and V1140-106 MDM8215 Baseband / PMIC8018 Power management / WTR1605 Cortex A5 Core up to 550 MHz 3 DSPs for modem and low power audio sub systems RPM Resource and power manager 2Gb NAND Flash x16, 2Gb Low Power Mobile DDR SDRAM x32 19.2MHz clock reference Dedicated heat sink in center area underneath the PCB GPS/GLONASS operation, GPS antenna biasing and diagnostics 3.2 Connectors 3.2.1 Module Signal and RF Connectors The LTE-NAD has 172 signal pins (2xAA and 2xBB) connector pads with 1.0mm pitch. The signal pads are located close to the board edges. There are three antenna pads, each collocated by RF GND connectors Main transmit and receive antenna – pin LGA_PRX_ANT Diversity antenna for WCDMA respective MIMO antenna for LTE – pin LGA_DRX_ANT_IN GNSS antenna for both GPS and GLONASS – pin LGA_GPS_DRX_ANT 3.2.2 Ground and Heat Dissipation Connectors To support the usage of module under complicated thermal conditions, there are a number of large grounded pads in the center of PCB. These pads are dedicated ground pads to transfer heat dissipation to a carrier board. This should be especially considered by customer designs. A reference design showing landing patterns and PCB stack-up is available on request. 3.3 Main Interfaces 3.3.1 USB The NAD has one USB2.0 OTG high speed (480MBit) compliant interface including the PHY. The IF consists of 5 signals: _______________________________________________________________________________________________________________ Seite 7 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe - USB_D_P: USB_D_M: USB_ID: USB_VBUS: VREG_USB3_3V075 USB Data Plus signal USB Data Minus signal Master/Slave Configuration1 USB Voltage Supply USB Voltage Output A dynamic reconfiguration between USB-Host or USB-Device is not foreseen, the NAD can be configured to USB-Host or USB-Device by the insertion of a resistor on the USB_ID line. 3.3.2 SIM Interface The NADs SIM interface is compatible to 1.8V and 3V SIM Cards, the necessary voltage and level shifting is handle by LTE-NAD automatically. The IF consists of the following signals: VREG_USIM USIM_CLK USIM_DATA USIM_RESET The data speed on the SIM IF is up to 4 Mbps, so HW designers should take care of the length and routing of the SIM IF to prevent potential EMC problems. 3.3.3 Power on The signal PON_N is used switch on the NAD-Module. PON_N is pulled against VMAIN on the LTE-NAD internally. Due to this fact it is recommended to pull this input against GND using an open collector or open drain output only. 3.3.4 Reset EXT_RESIN_N is used to reset the LTE-NAD-Module, see table of LTE-NAD signal pins. There are further reset signals available, please check . RES_IN is pulled against VMAIN power on the LTE-NAD internally. Therefore, it is recommended to pull this input against GND using an open collector or open drain output only. 3.3.5 GPIOs The LTE-NAD is configured in the slave mode. For other configuration of the USB – Interface please contact peiker acustic GmbH & Co.KG. _______________________________________________________________________________________________________________ Seite 8 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe There are 51 GPIOs on the LTE-NAD module available. Most of them are part of the 5 GSBIs provided in next chapter. They are used for different interfaces (see Table 1 and the following chapters). For allocation of GPIOs/GSBIs to different configurations please contact peiker acustics GmbH & Co.KG GPIOs and GSBIs share the same output pins and may not available when used as GSBI configuration. The following GPIOs are not belonging to a GSBI bundle: GPIO 47, 72, 82, 25, 28, 26, 27, 84, 80, 21, 23, 22, 24, 20, 1, 78, 79, 85, 86, 69, 0, 77, 65, 61, 68, 51, 54, 73, 48, 49, 53. The following GPIOs are belonging to a GSBI bundle: GPIO 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 29, 30. 3.3.6 GSBIs Each GSBI (General Serial Bus Interface) consists of a bundle of 4 GPIOs. 5 GSBI are available. The reference voltage is of the GSBIs is 1.8V. Available signals on GSBI bundles at the board to board connector: GSBI1: GSBI2: GSBI3: GSBI4: GSBI5: GSBI1_0, GSBI1_1, GSBI1_2, GSBI1_3 (GPIO_29, 30, 2, 3) GSBI2_0, GSBI2_1, GSBI2_2, GSBI2_3 (GPIO_4, 5, 6, 7) GSBI3_0, GSBI3_1, GSBI3_2, GSBI3_3 (GPIO_8, 9, 10, 11) GSBI4_0, GSBI4_1, GSBI4_2, GSBI4_3 (GPIO_12, 13, 14, 15) GSBI5_0, GSBI5_1, GSBI5_2, GSBI5_3 (GPIO_16, 17, 18, 19) For the standard configuration of the GSBIs see the following Fehler! Verweisquelle konnte nicht gefunden werden. 3. _______________________________________________________________________________________________________________ Seite 9 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Figure 1 V1140-xxx General Serial Bus Interface GSBI interface configuration 3.3.7 Module Pin-out Table 1 Module Pin-out PIN Signal 2 – 22 23 24 25 26 27 28 GND GND GPIO47 JTAG_TDI JTAG_TDO GPIO_72 JTAGTMS JTAG_TRST_N Direction related to LTE-NAD Input Power Input Power Input Input Output IN/OUT Input Input Comment Main ground connection, Corner pad Main ground connection WDOG_DISABLE JTAG Interface JTAG Interface JTAG Interface JTAG Interface _______________________________________________________________________________________________________________ Seite 10 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe PIN Signal 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 JTAG_RTCK GND JTAG_TCK JTAG_RESOUT_N GPIO82 JTAG_PS_HOLD EXT_RESIN_N GND RESOUT_N GPIO29_ SDC2_CMD GPIO25_ SDC2_D0 GPIO28_ SDC2_D3 GPIO30_ SDC2_CLK GND GPIO26_ SDC2_D1 GPIO27_ SDC2_D2 PM_GPIO4 GPIO84 GND SDC1_CMD SDC1_DATA0 SDC1_DATA3 SDC1_CLK GPIO80_SDC1_DET_N GND SDC1_DATA2 SDC1_DATA1 GPIO21_ I2S_WS GPIO23_ I2S_DOUT GPIO22_ I2S_DIN GPIO24_ I2S_MCLK GND GPIO20_ I2S_CLK GPIO19_GSBI5_3 GPIO17_GSBI5_1 GPIO18_GSBI5_2 GPIO15_GSBI4_3 GND Direction related to LTE-NAD Output Input Power Input Input Output Input Input Input Power Output IN/OUT IN/OUT IN/OUT Output Input Power IN/OUT IN/OUT IN/OUT Output Input Power IN/OUT IN/OUT IN/OUT Output IN/OUT Input Power IN/OUT IN/OUT Output Output Input Output Input Power Output Output IN/OUT Input Output Input Power 67 USB_D_P IN/OUT 68 USB_D_M IN/OUT 69 70 GND Input Power Input GPIO14_GSBI4_2 Comment JTAG Interface Main ground connection JTAG Interface JTAG Interface NAD – Runnig, Controll signal JTAG Interface Input Reset for LTE-NAD module Main ground connection Output Reset SD Card CMD SD Card Data 0 SD Card Data 3 SD Card Clock Main ground connection SD Card Data 1 SD Card Data 2 Reset of the Codec Main ground connection SD Card CMD SD Card Data 0 SD Card Data 3 SD Card Clock Main ground connection, Corner pad SD Card Data 2 SD Card Data 1 I²S - Word Select I²S – Data Output I²S - Data Input I²S - Master Clock Main ground connection I²S - Clock 2 – Pin – UART TXD 3 I²C – Serial Data 2 – Pin – UART RXD 3 4 – Pin – UART TXD 1 Main ground connection High – Speed USB Device for communication High – Speed USB Device for communication Main ground connection 4 – Pin – UART RXD 1 _______________________________________________________________________________________________________________ Seite 11 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe PIN Signal 71 72 73 74 75 GPIO13_GSBI4_1 GPIO16_GSBI5_0 USB_ID GPIO12_GSBI4_0 GND Direction related to LTE-NAD Input Output Input Output Input Power 76 USB_VBUS Input 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 GPIO11_GSBI3_3 GPIO10_GSBI3_2 GPIO9_GSBI3_1 GPIO8_GSBI3_0 GPIO6_ UIM2_CLK GND GPIO2_ UIM1_CLK GPIO5_ UIM2_RST GPIO7_ UIM2_DATA GPIO4_ UIM2_DET GND HSIC_DATA GND HSIC_STROBE GND GPIO3_ UIM1_DATA GPIO1_ UIM1_RST GPIO78 GPIO79_ HSIC_RDY GPIO85 GPIO86_ GPS_EXT_LNA_EN GND VREG_USB3_3V075 GND VREG_MSME_1V8 GND VREG_UIM2 VREG_SDC1_2V95 GND VREG_UIM1 GND GND VMAIN VMAIN VMAIN VMAIN Output Input IN/OUT IN/OUT IN/OUT Input Power Output IN/OUT IN/OUT IN/OUT Input Power IN/OUT Input Power IN/OUT Input Power Output Output IN/OUT Output Output 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 Comment 4 – Pin – UART Clear To Send 1 I²C - Clock 4 – Pin – UART Ready For Receive 1 Main ground connection High – Speed USB Device for communication 2 – Pin – UART TXD 2 2 – Pin – UART RXD 2 Main ground connection SIM Card - Clock Main ground connection, Corner pad Connection to Ethernet Controller Main ground connection Connection to Ethernet Controller Main ground connection SIM Card – Data 1 SIM Card – Reset 1 Reset of Ethernet Controller Time synchronization IN/OUT Input Power Output Power Input Power Output Power Input Power Output Power Output Power Input Power Output Power Input Power Input Power Input Power Input Power Input Power Input Power Main ground connection Output Power to USB Main ground connection Output Power Main ground connection Output Power to SIM Card 2 Output Power to SD Card 1 Main ground connection Output Power to SIM Card 1 Main ground connection Main ground connection Main power Main power Main power Main power _______________________________________________________________________________________________________________ Seite 12 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe PIN Signal 113 114 115 116 117 118 119 120 121 GND GND PON HW-REV-RESISTOR PM_GPIO3 GND PM_MPP5 PM_MPP1 GND Direction related to LTE-NAD Input Power Input Power Input Output IN/OUT Input Power Input Input Input Power 122 GPIO69 Output 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 – 152 153 154 – 160 161 162 – 164 165 166 167 – 172 GPIO0_ UIM1_DET GPIO77 GPIO65 GPIO61 PON_N GND GPIO68 GPIO51 GPIO54 GND PM_MPP2 PM_GPIO2 PM_GPIO1 PM_GPIO6 GND GPIO73 GND GPIO48 GPIO49 GPIO53 Input Output Output Input Input Input Power Output Input Input Input Power Input IN/OUT IN/OUT IN/OUT Input Power IN/OUT Input Power Input Input Input GND Input Power Main ground connection Main ground connection Power On Main ground connection PM – ADC – channel PM – ADC – channel Main ground connection Switch between main and back up antenna SIM Card – Detection 1 Reset signal of SDC2 NAD – Wake up NAD – Update Power On Main ground connection PS-3V8-Hold BOOT_CONFIG3 BOOT_CONFIG0 Main ground connection PM – ADC - channel Main ground connection Main ground connection, Corner pad BOOT_CONFIG6 BOOT_CONFIG5 BOOT_CONFIG1 Main ground connection Connection to the antenna switch LGA_PRX_ANT GND Comment Input Power Main ground connection Connection to the antenna connector LGA_GPS_DRX_ANT GND Input Power Main ground connection LGA_DRX_ANT_IN LGA_DRX_ANT_OUT Input Connection to the antenna switch GND Input Power Main ground connection _______________________________________________________________________________________________________________ Seite 13 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Note: Pins should be grounded when not used in design. 3.4 Supply Voltage The external supply voltage is applied to LTE-NAD by 8 Pins on modules signal connectors. PINs 109, 110, 111, 112 for VMAIN PINs 107, 108, 113, 114 for the corresponding GND Please note that there are further main ground connection that should be connected to ensure proper NAD function. TA = -40°C … +85°C Absolute minimum/maximum supply voltages Nominal supply voltage Recommended supply voltage Voltage drop @ GSM power burst (33dBm) 3.6V ~ 4.0V 3.8V 3.8V <100mV During Hi RF Power GSM bursts the power amplifier can draw peak currents > 2Amps at VMAIN. The voltage drop during the GSM burst shall not exceed 100mV. 3.5 Power Consumption TA = +25°C, VPH_PWR =3.8V Voice Voice Voice Voice call call call call WCDMA WCDMA WCDMA WCDMA BC1 BC2 BC5 BC8 Voice call GSM850 Voice call GSM900 Voice call GSM1800 Voice call GSM1900 Standby current GSM Standby current WCDMA Standby current LTE DRX = 5 DRX = 7 DRX = 7 Output Power max. (typ. 23dBm) ~530mA ~570mA ~630mA ~580mA Output Power 0 dBm ~145mA ~145mA ~140mA ~140mA PCL 5 (typ. 32.5 dBm) ~260mA ~270mA PCL 0 (typ.30.5dBm) ~165mA ~165mA PCL 19 (typ. 5dBm) ~65mA ~65mA PCL 15 (typ.0dBm) ~65mA ~65mA Tbd mA Tbd mA _______________________________________________________________________________________________________________ Seite 14 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Output Power Output Power LTE data call B3 LTE data call B7 LTE data call B20 3.6 Transmitter Tbd. 3.7 Receiver Tbd. 3.8 Environmental Specification 3.8.1 Temperature Range Range Operating temp. range Operating temp. range -20°C … +65°C -40°C … +85°C Storage temp. range -40°C … +85°C Note 1 3GPP spec. conform Operational Performance might slightly deviate from 3GPP spec. Note 1: Due to temperature specification of the chipset, the temperature of the power manager and the temperature of the modem chip shall not exceed +85°C. _______________________________________________________________________________________________________________ Seite 15 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 4 Evaluation Kit For the NAD V1140-xxx, there is an evaluation board available. Features: - On board 12V DC power supply (alternatively 3,8V DC direct connected, unbuffered). - USB port type B - SIM card tray - 20 pin JTAG header for debugging - 2 UART ports connected to DB9 - CODEC supported by I2S and I2C interfaces Using the evaluation board with an external power supply By default the module can be supplied by a switching regulator at 12V DC input voltage or by the module VCC at 3.8V. 3.8V supply should be able to deliver 3.5A max. Sense contacts are for supplies which support the corresponding feature. Using the evaluation board with on board 3.8V regulator For use at 3.8V simply disconnect the 12V supply and plug on 3.8V. Note: Make sure that the external power supply is not generating spikes or hazards higher than 4.0V. LTE-NAD Module gets damaged when spikes or hazards above 4.0V are applied RF Connector For RF measurements use main antenna connector _______________________________________________________________________________________________________________ Seite 16 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Figure 2 Evaluation Kit for V1140-xxx. _______________________________________________________________________________________________________________ Seite 17 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Figure 3 Power supply for Evaluation Kit for V1140-xxx. Figure 4 SIM card and USB interfaces for Evaluation Kit for V1140-xxx. _______________________________________________________________________________________________________________ Seite 18 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Figure 5 RF interfaces for Evaluation Kit for V1140-xxx. AT Command interface The modules supports standard AT command as listed below. Commands are compliant to 3GPP TS 27.007 and TS 27.005 Command Description AT+CMGF AT+CSCA AT+CMGS AT+CGMI AT+CGMM AT+CGMR AT+CGSN Message Format Service Centre Address Send Message Manufacturer Identification Request model identification Request revision identification Request product serial number Request international mobile subscriber identification Call mode AT+CIMI AT+CMOD AT+CHUP ATD ATA ATH AT+CBST AT+CEER AT+CVHU AT+CREG AT+COPS AT+CLCK AT+CPWD Comment Only one Parameter is supported by the device. Hang up call Initiate a CS or PS call or supplementary service Answer incoming CS call command Hangup CS call command Select bearer service type Extended error report Voice hangup control Network registration PLMN selection Facility lock Change password _______________________________________________________________________________________________________________ Seite 19 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe Command Description AT+CLIP AT+CLIR AT+CCWA AT+CHLD AT+CUSD AT+CLCC AT+CPOL AT+CPAS AT+CFUN AT+CPIN AT+CSQ AT+CMER AT+CSIM AT+CRSM AT+CMEE AT+CGDCONT AT+CGEQREQ AT-CGATT AT+CGACT AT+CGPADDR AT+CGSMS ATE Calling line identification presentation Calling line identification restriction Call waiting Call related supplementary services Unstructured supplementary service data List current calls Preferred PLMN list Phone active status Set phone functionality Enter PIN Signal quality Mobile termination event reporting Generic SIM access Restricted SIM access Report mobile termination error Define PDP context Request 3G quality of service profile PS attach or detach PDP context activate or deactivate Show PDP address Select service for MO SMS messages Character Echo ON/OFF AT+CSMS AT+CSMP AT+CSDH AT+CSCB Check Message Service support Set Text Mode Parameters Show Text Mode Parameters Select Cell Broadcast Message Types Save Settings AT+CSAS AT+CRES AT+CMGL AT+CNMA AT+CMGC AT+CMMS AT+ATV AT+ATX AT+CNMI AT+CPMS AT+CMGW AT+CMSS AT+CMGD AT+CNUM AT+CPBS AT+CPBR AT+CPBW Comment Restore Settings Only one Parameter is supported by the device. Only one Parameter is supported by the device. List messages New message acknowledgement Send Command More Messages to Send DCE response format Result code selection and call progress monitoring control New Message Indications to TE Preferred Message Storage Write Message to Memory Send Message from Storage Delete Messages Get MSISDN Select phonebook memory storage Read phonebook entries Writephonebook entry _______________________________________________________________________________________________________________ Seite 20 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 6 Safety Recommendations according to EN60950-1 This device must be supplied by a limited power source according to EN 60950-1. The clearance and creepage distances required by the end product must be withheld when the module is installed. The cooling of the end product shall not negatively be influenced by the installation of the module. _______________________________________________________________________________________________________________ Seite 21 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 7 List of Acronyms 3GPP ADC ADN A-GPS 3 rd Generation Partnership Project Analog Digital Converter Abbreviated Dialing Number Assisted GPS AMR Adaptive Multi Rate AT AWS BER CLIP CLIR CSD DARP DTMF FDN FTP GSM GPIO GPRS GPS HSPA HW LED MO MT OEM PCB PCM PDU PIN RF RoHs UART USB USIM UMTS WCDMA Attention Command Advanced Wireless Services Bit Error Rate Calling Line Identification Presentation Calling Line Identification Restriction Circuit Switch Data Downlink Advanced Receiver Performance Dual Tone Multi Frequency Fixed Dialing Number File Transfer Protocol Global System for Mobile communication General Purpose Input Output General Packet Radio Service Global Positioning System High Speed Uplink Packet Access Hardware Led Emitting Diode Mobile Originated Mobile Terminated Original Equipment Manufacturer Printed Circuit Board Pulse Code Modulation Protocol Data Unit Personal Identification Number Radio Frequency Restriction of Hazardous Substances Universal Asynchronous Receiver and Transmitter Universal Serial Bus Universal Subscriber Identity Module Universal Mobile Telecommunications System Wideband Code Division Multiple Access _______________________________________________________________________________________________________________ Seite 22 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 8 Regulatory Certifications 8.1 USA (FCC) This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 8.1.2 FCC Warnings and Notices WARNING: The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by peiker acustic GmbH & Co. KG could void the user's authority to operate the equipment. NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 8.2 Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Canada (IC) This Class b digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe b est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. _______________________________________________________________________________________________________________ Seite 23 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe 8.3 OEM Responsibilities Antenna - The antenna gain, including cable loss, must not exceed 1,47dBd at 700 MHz & 850 MHz, 6dBi at 1700 MHz and 3.01dBi at 1900 MHz for satisfying RF exposure compliance. The systems antenna(s) must be installed such that 20 cm is maintained between the antenna(s) and the body of the user or nearby persons. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The preceding statement must be included as a Caution statement in OEM product manuals in order to alert users of FCC RF Exposure compliance. Power Regulation The host equipment must provide power regulation circuitry to ensure that the module is supplied with stable 3.8VDC. FCC Labeling - The V1140-101 module is labeled with its own FCC ID Number. If the FCC ID is not visible when the V1140-101 module is installed inside another device, then the host device must contain the FCC ID number with the statement such as the following: "Contains Transmitter Module FCC ID: QWY-V1140-101" or "Contains FCC ID: QWY-V1140-101" The V1140-103 module is labeled with its own FCC ID Number. If the FCC ID is not visible when the V1140-103 module is installed inside another device, then the host device must contain the FCC ID number with the statement such as the following: "Contains Transmitter Module FCC ID: QWY-V1140-103" or "Contains FCC ID: QWY-V1140-103" The V1140-105 module is labeled with its own FCC ID Number. If the FCC ID is not visible when the V1140-105 module is installed inside another device, then the host device must contain the FCC ID number with the statement such as the following: "Contains Transmitter Module FCC ID: QWY-V1140-105" or "Contains FCC ID: QWY-V1140-105" IC Labeling - The V1140-101 module is labeled with its own IC ID Number. If the IC ID is not visible when the V1140-101 module is installed inside another device, then the host device must contain the IC ID number with the statement such as the following: "Contains Transmitter Module IC: 6588A-V1140101" or "Contains IC: 6588A-V1140101". _______________________________________________________________________________________________________________ Seite 24 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe - The V1140-103 module is labeled with its own IC ID Number. If the IC ID is not visible when the V1140-103 module is installed inside another device, then the host device must contain the IC ID number with the statement such as the following: "Contains Transmitter Module IC: 6588A-V1140103" or "Contains IC: 6588A-V1140103". The V1140-105 module is labeled with its own IC ID Number. If the IC ID is not visible when the V1140-105 module is installed inside another device, then the host device must contain the IC ID number with the statement such as the following: "Contains Transmitter Module IC: 6588A-V1140105" or "Contains IC: 6588A-V1140105". _______________________________________________________________________________________________________________ Seite 25 peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369 Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 25 Language : en-US Tagged PDF : Yes Author : PEIKER acustic Creator : Microsoft® Office Word 2007 Create Date : 2014:06:17 09:45:04+02:00 Modify Date : 2014:06:17 09:45:04+02:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools