Peiker acustic V1231-0 LTE-Advanced Network Access Device User Manual

Peiker acustic GmbH & Co. KG LTE-Advanced Network Access Device

User Manual

Download: Peiker acustic V1231-0 LTE-Advanced Network Access Device User Manual
Mirror Download [FCC.gov]Peiker acustic V1231-0 LTE-Advanced Network Access Device User Manual
Document ID3563166
Application ID2d5EJ/5se1MV71jjB4VZlQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize121.52kB (1519024 bits)
Date Submitted2017-09-15 00:00:00
Date Available2018-03-01 00:00:00
Creation Date2017-09-04 17:21:58
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2017-09-04 17:21:58
Document TitleUser Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: PEIKER acustic

V123x-0 (LTE-NAD-A)
User manual
Peiker product IDs:
2189-230-042-00
2189-231-042-00
2189-232-042-00
2189-233-042-00
Revision:
Date:
1.4
August 2017
(V1230-0)
(V1231-0)
(V1232-0)
(V1233-0)
_______________________________________________________________________________________________________________ Seite 1
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Revision History
Date
28.02.2017
01.03.2017
06.03.2017
Revision
1.0
1.1
1.2
Name
mgi
phse
mgi
08.08.2017 1.3
phse
04.09.2017 1.4
phse
Comment
Initial document based on V123x-1 documents
Some rewording as well as some corrections
Model name changed to V123x-0
Renumbering of some sections
Added new section called “Maximum TX Output Power”
Updated the temp range table from section 2.12.1
Reworked section 6
Updated the pin-out table
_______________________________________________________________________________________________________________ Seite 2
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Content
Introduction ..........................................................................................................................................4
1.1 Scope ..................................................................................................................................................4
1.2 Audience ............................................................................................................................................4
1.3 Contact information, Support .........................................................................................................4
Product Overview ................................................................................................................................5
2.1 Product Variants................................................................................................................................5
2.2 Supported Technology/Frequency Bands .....................................................................................5
2.3 Maximum TX Output Power ............................................................................................................5
2.5 Features .............................................................................................................................................6
2.6 Certifications / Approvals.................................................................................................................7
2.8 Connectors .........................................................................................................................................7
2.8.1 Module Signal and RF Connectors ..........................................................................................7
2.8.2 Ground and Heat Dissipation Connectors..............................................................................7
2.9 Main Interfaces .................................................................................................................................8
2.9.1 USB ..............................................................................................................................................8
2.9.2 SIM Interface .............................................................................................................................8
2.9.3 Power on.....................................................................................................................................8
2.9.4 Reset ...........................................................................................................................................8
2.9.5 GPIOs ..........................................................................................................................................9
2.9.6 GSBIs...........................................................................................................................................9
2.9.7 Module Pin-out.........................................................................................................................10
2.10 Supply Voltage ..............................................................................................................................15
2.11 Power Consumption .....................................................................................................................15
2.12 Environmental Specification ........................................................................................................16
2.12.1 Temperature Range ..............................................................................................................16
Evaluation Kit .....................................................................................................................................17
AT Command interface .....................................................................................................................20
Safety Recommendations according to EN60950-1 .....................................................................22
RED/FCC/IC Regulatory Notices ......................................................................................................23
6.1
Modifications ..............................................................................................................................23
6.2
Interference................................................................................................................................23
6.3
FCC Class B Digital Device .......................................................................................................23
6.3
OEM Responsibilities .................................................................................................................24
List of Acronyms ................................................................................................................................25
_______________________________________________________________________________________________________________ Seite 3
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
1
Introduction
1.1 Scope
This document gives an overview about electrical, mechanical and functional details of the peiker LTENAD-A V123x-0 modules.
1.2 Audience
Information to integrate the module in some other applications.
1.3 Contact information, Support
peiker acustic GmbH & Co KG
Max-Planck Street 32
D-61381 Friedrichsdorf / Ts.
Germany
http://www.peiker.de
info@peiker.de
_______________________________________________________________________________________________________________ Seite 4
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2
Product Overview
2.1 Product Variants
The LTE-NAD-A module family consists of four regional variants:
Peiker product #
2189-230-042-00 (V1230-0)
2189-231-042-00 (V1231-0)
2189-232-042-00 (V1232-0)
2189-233-042-00 (V1233-0)
Module configuration
ECE configuration
NA configuration
CHN configuration
RoW configuration
2.2 Supported Technology/Frequency Bands
V1230-0
GSM Bands
WCDMA Bands
LTE Bands
900MHz and 1800MHz
FDD1, FDD3 and FDD8
eFDD1, eFDD3, eFDD7, eFDD20, eFDD28A, eFDD32 and eTTD38
V1231-0
GSM Bands
WCDMA Bands
LTE Bands
850MHz and 1900MHz
FDD2, FDD4 and FDD5
eFDD2, eFDD4, eFDD5, eFDD7, eFDD12 and eFDD29
V1232-0
GSM Bands
WCDMA Bands
LTE Bands
900MHz and 1800MHz
FDD1 and FDD8
eFDD1, eFDD3, eFDD7, eTTD38, eTTD40 and eTTD41
V1233-0
GSM Bands
WCDMA Bands
LTE Bands
850MHz, 900MHz, 1800MHz and 1900MHz
FDD1, FDD2, FDD3, FDD5, FDD6, FDD8 and FDD19
eFDD1, eFDD3, eFDD5, eFDD7, eFDD8, eFDD9, eFDD19, eFDD21,
eFDD28B and eTTD40
2.3 Maximum TX Output Power
GSM 850 and GSM 900 (PCL=5, 1 UL TS): 34,5 dBm
GSM 1800 and GSM 1900 (PCL=5, 1 UL TS): 31,5 dBm
GPRS 850 and GPRS 900 (PCL=5, 4 UL TS): 29 dBm
GPRS 1800 and GPRS 1900 (PCL=0, 4 UL TS): 26 dBm
EDGE 850 and EDGE 900 (PCL=8, 4 UL TS): 23 dBm
_______________________________________________________________________________________________________________ Seite 5
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
EDGE 1800 and EDGE 1900 (PCL=2, 4 UL TS): 22 dBm
WCDMA (all supported frequency bands): 25 dBm
LTE (all supported frequency bands): 25 dBm
2.4 Module to Hosts Mapping
The below table shows the mapping between the module variants and the host/ATM-02 devices:
Module
Host devices embedding this module variant
V1230-0
V1231-0
V1232-0
V1233-0
ATM-02-ECE-R1 and ATM-02-ECE-T1
ATM-02-US-R1 and ATM-02-US-T1
ATM-02-CHN-R1 and ATM-02-CHN-T1
ATM-02-ROW-R1 and ATM-02-ROW-T1
2.5 Features
Features
- Same footprint and pin-out (all modules)
- Voice and data calls (all modules)
- IMS/VoLTE
- 4G: Rel-11, 3G/3G+: Rel-9, 2G: Rel-9
- DTM/eDTM (all modules)
- Standalone GPS, GLONASS, Galileo, SBAS, QZSS and BeiDou
Data rates
- GPRS/EDGE: Multislot class 33
- WCDMA: DL /UL up to 384kbps
HSPA+:
Category 24 in DL using 64 QAM and Dual-Cell; Up to 42 Mbps (All modules except
V1231-0)
Category 14 in DL using 64 QAM; Up to 21 Mbps (V1231-0)
Category 6 in UL using 16 QAM; Up to 5.76 Mbps (All modules)
- LTE Category 11: Up to 450 Mbps in DL using 3 CCs, up to 75 Mbps in UL (All modules)
Power Classes
- LTE: All supported bands, Power Class 3
- WCDMA: All supported bands, Power Class 3
- EDGE: 850/900/1800/1900, Power Class E2
- GSM/GPRS: 850/900, Power Class 4
- GSM/GPRS: 1800/1900, Power Class 1
Dimension and Weight
- Dimensions: 35mm x 38mm x 4,35mm
- Weight < 10 grams
_______________________________________________________________________________________________________________ Seite 6
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2.6 Certifications / Approvals
V1230-0
V1231-0
V1232-0
V1233-0
GCF
RED
Planned
Planned
PTCRB
FCC/IC
AT&T
Planned
Planned
Planned
Planned
Planned
Planned
2.7 HW Features
Qualcomm X12 LTE, 20nmSoC
MDM9240 Baseband / PMIC: PMD9645 / WTR3925 WTR4905
Cortex-A7 up to 1.2 GHz
Modem and low power audio sub systems: QDSP6 processor at up to 850 MHz (turbo)
RPM Resource and power manager: Cortex M3 up to 100 MHz
4Gb NAND Flash
2Gb LPDDR2 SDRAM
19.2MHz clock reference
GPS, GLONASS, BeiDou, and Galileo
2.8 Connectors
2.8.1 Module Signal and RF Connectors
LTE-NAD-A has 172 signal pins (2xAA and 2xBB) connector pads with 1.0mm pitch. The signal pads are
located close to the board edges.
There
are three antenna pads, each collocated by RF GND connectors
Main transmit and receive antenna – pin LGA_PRX_ANT
Diversity antenna for WCDMA respective MIMO antenna for LTE – pin LGA_DRX_ANT_IN
GNSS antenna for both GPS and GLONASS – pin LGA_GPS_DRX_ANT
2.8.2 Ground and Heat Dissipation Connectors
To support the usage of module under complicated thermal conditions, there are a number of large
grounded pads in the center of PCB. These pads are dedicated ground pads to transfer heat dissipation
to a carrier board.
This should be especially considered by customer designs. A reference design showing landing patterns
and PCB stack-up is available on request.
_______________________________________________________________________________________________________________ Seite 7
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2.9 Main Interfaces
2.9.1 USB
LTE-NAD-A has one USB2.0 OTG high speed (480MBit) compliant interface including the PHY. This IF
consists of four signals:
USB_HS_DP:
USB_HS_DM
USB_HS_ID:
MDM_VBUS_DET:
USB
USB
USB
USB
Data Plus signal
Data Minus signal
high-speed data - ID
Voltage Supply
LTE-NAD-A has one USB3.0 high speed (480MBit) compliant interface including the PHY. This IF consists
of four signals:
MDM_USB_SS_RX_P:
MDM_USB_SS_RX_M
MDM_USB_SS_TX_P:
MDM_USB_SS_TX_M:
USB
USB
USB
USB
3.0
3.0
3.0
3.0
receive – plus
receive – minus
transmit – plus
transmit – minus
A dynamic reconfiguration between USB-Host or USB-Device is not foreseen. LTE-NAD-A can be
configured to USB-Host or USB-Device by insertion of a resistor on the USB_ID line.
2.9.2 SIM Interface
LTE-NAD-A has two SIM interfaces that are compatible for both 1.8V and 3V SIM Cards. Those IFs
consist of the following signals:
VREF_UIM1 / VREF_UIM2
UIM1_CLK / UIM2_CLK
UIM1_DETECT / UIM2_DETECT
UIM1_DATA / UIM2_DATA
UIM1_RESET / UIM2_RESET
The data rate of the SIM IF is up to 4 Mbps, so HW designers should take care of the length and routing
of the SIM IF to prevent potential EMC problems.
2.9.3 Power on
The signal PON_1 is used to switch on LTE-NAD-A. As PON_1 is pulled against VMAIN internally, it is
recommended to pull this input against GND using an open collector or open drain output only.
2.9.4 Reset
PMD_RESIN_N is used to reset LTE-NAD-A. As PMD_RES_IN is pulled against VMAIN internally, it is
recommended to pull this input against GND using an open collector or open drain output only.
_______________________________________________________________________________________________________________ Seite 8
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2.9.5 GPIOs
There are 51 GPIOs available on LTE-NAD-A, some of them being part of the five GSBIs (see next
section). They are used for different interfaces (see Table 1 and the following sections). For allocation of
GPIOs/GSBIs to different configurations, please contact us.
GPIOs and GSBIs share the same output pins and may not available when used as GSBI configuration.
The following GPIOs do not belong to a GSBI bundle:
GPIO 47, 72, 82, 25, 28, 26, 27, 84, 80, 21, 23, 22, 24, 20, 1, 78, 79, 85, 86, 69, 0, 77, 65, 61, 68, 51,
54, 73, 48, 49, 53.
The following GPIOs belongs to a GSBI bundle:
GPIO 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 29, 30.
2.9.6 GSBIs
Five GSBIs (General Serial Bus Interfaces) are available in total, each of them consisting of four GPIOs.
The reference voltage of the GSBIs is 1.8V.
Available signals on GSBI bundles at the board to board connector:
GSBI1:
GSBI2:
GSBI3:
GSBI4:
GSBI5:
GSBI1_0,
GSBI2_0,
GSBI3_0,
GSBI4_0,
GSBI5_0,
GSBI1_1,
GSBI2_1,
GSBI3_1,
GSBI4_1,
GSBI5_1,
GSBI1_2,
GSBI2_2,
GSBI3_2,
GSBI4_2,
GSBI5_2,
GSBI1_3
GSBI2_3
GSBI3_3
GSBI4_3
GSBI5_3
(GPIO_29, 30, 2, 3)
(GPIO_4, 5, 6, 7)
(GPIO_8, 9, 10, 11)
(GPIO_12, 13, 14, 15)
(GPIO_16, 17, 18, 19)
_______________________________________________________________________________________________________________ Seite 9
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2.9.7 Module Pin-out
Table 1
Module Pin-out
Pin
numbe Category
9x40 Pin name
Description
GND
GND
Ground
USB3.0
MDM_USB_SS_TX_M
USB 3.0 transmit – minus
105
USB3.0
MDM_USB_SS_TX_P
USB 3.0 transmit – plus
GND
GND
Ground
106
GND
GND
Ground
USB3.0 (9x40)
MDM_USB_SS_RX_M
USB 3.0 receive – minus
107
USB3.0 (9x40)
MDM_USB_SS_RX_P
USB 3.0 receive – plus
GND
GND
Ground
108
GND
GND
Ground
PCIE/WLAN IF
PCIE_REFCLK_M
PCIe reference clock – minus
109
PCIE/WLAN IF
PCIE_REFCLK_P
PCIe reference clock – plus
GND
GND
Ground
110
GND
GND
Ground
PCIE/WLAN IF
PCIE_TX_M
111
PCIE/WLAN IF
PCIE_TX_P
PCIe transmit – plus
GND
GND
Ground
112
GND
GND
Ground
10
PCIE/WLAN IF
PCIE_RX_M
113
PCIE/WLAN IF
PCIE_RX_P
11
GND
GND
Ground
114
GND
GND
Ground
12
USB
PMD_USB_ID
USB high-speed data – ID
115
USB
USB2_EXT_VBUS_DET
External USB Vbus detection
13
GND
GND
Ground
116
GPIO
GPIO_86
Configurable I/O
14
Reserved
Reserved
Inter-chip communication
117
GND
GND
Ground
15
Reserved
Reserved
Inter-chip communication
118
GND
GND
Ground
16
USB
MDM_USB_HS_DP
USB high-speed data – plus
119
USB
MDM_USB_HS_DM
USB high-speed data – minus
17
GND
GND
Ground
PCIe transmit – minus
PCIe receive – minus
PCIe receive – plus
_______________________________________________________________________________________________________________ Seite 10
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
120
SDIO IF/eMMC
GPIO_96 / MDM_SDC1_DATA_4
Secure digital controller data bit 4
18
SDIO IF/eMMC
GPIO_97 / MDM_SDC1_DATA_5
Secure digital controller data bit 5
121
SDIO IF/eMMC
GPIO_98 / MDM_SDC1_DATA_6
Secure digital controller data bit 6
19
SDIO IF/eMMC
GPIO_99 / MDM_SDC1_DATA_7
Secure digital controller data bit 7
122
SDIO IF
GPIO_81 / SD_CARD_DET_N
Secure digital card detection
20
SDIO IF
MDM_SDC1_DATA_0
Secure digital controller data bit 0
123
SDIO IF
MDM_SDC1_DATA_1
Secure digital controller data bit 1
21
SDIO IF
MDM_SDC1_DATA_2
Secure digital controller data bit 2
124
SDIO IF
MDM_SDC1_DATA_3
Secure digital controller data bit 3
22
GND
GND
Ground
125
SDIO IF
MDM_SDC1_CMD
Secure digital controller 2 command
23
SDIO IF
MDM_SDC1_CLK
Secure digital controller 2 clock
126
SIM1
VREG_L11_UIM1
Reference for UIM I/O pads
GND
Ground
24
127
SIM1
GPIO_79 / MDM_UIM1_CLK
UIM1 clock
25
SIM1
GPIO_78 /MDM_UIM1_RESET
UIM1 reset
128
SIM1
GPIO_77 / MDM_UIM1_DETECT
UIM1 detect (non dual voltage)
26
SIM1
GPIO_76 /MDM_UIM1_DATA
UIM1 data
27
GND
GND
Ground
28
I2S
GPIO_15 / I2S_CLK
I2S Data Clock
129
GND
GND
Ground
29
I2S
MDM_MCLK
Audio Master clock
130
GND
GND
Ground
30
I2S
GPIO_12 / I2S_WS
I2S word select
131
I2S
GPIO_13 / I2S_DO
I2S Data Output
31
I2S
GPIO_14 / I2S_DI
I2S Data Input
132
GND
GND
Ground
32
GPIO_19 / ANT_SW_2
Antenna switch 2
133
GPIO_18 / ANT_SW_1
Antenna switch 1
33
UART4
GPIO_17 / UART4_RX
UART4 receive data
134
UART4
GPIO_16 / UART4_TX
UART4 transmit data
34
GND
GND
Ground
135
GND
GND
Ground
35
GPIO
GPIO_50
Configurable I/O
GPIO_23 / ANT_SW_4
Antenna switch 4
136
36
GND
GND
Ground
137
GND
GND
Ground
37
MDM_RESOUT_N
138
GPIO_22 / ANT_SW_3
Antenna switch 3
_______________________________________________________________________________________________________________ Seite 11
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
38
UART1
GPIO_21 / UART1_RX
UART1 receive data
139
UART1
UART1_TX
UART2 transmit data
39
GND
GND
Ground
140
SPI
GPIO_7 / SPI_CLK
SPI clock
40
SPI
GPIO_6 / SPI_CS_N
SPI chip select
141
SPI
GPIO_5 / SPI_MISO
SPI master-in slave-out
41
SPI
GPIO_4 / SPI_MOSI
SPI master-out slave-in
142
SIM2
GPIO_2 / MDM_UIM2_RESET
UIM2 reset
42
SIM2
GPIO_1 /MDM_UIM2_DETECT
UIM2 detect (non dual voltage)
143
SIM2
GPIO_0 /MDM_UIM2_DATA
UIM2 data
43
GND
GND
Ground
144
SIM2
VREG_L13_UIM2
Reference for UIM I/O pads
44
SIM2
GPIO_3 / MDM_UIM2_CLK
UIM2 clock
145
GND
GND
Ground
45
GND
GND
Ground
146
GPIO
GPIO_94
Configurable I/O
46
GPIO
GPIO_80
Configurable I/O
147
GPIO
GPIO_90
Configurable I/O
47
GPIO
GPIO_82
Configurable I/O
148
GPIO
GPIO_91
Configurable I/O
48
GPIO
GPIO_87
Configurable I/O
149
GPIO
GPIO_92
Configurable I/O
49
GPIO
GPIO_88
Configurable I/O
150
GPIO
GPIO_93
Configurable I/O
50
GPIO
GPIO_89
Configurable I/O
151
I2C
GPIO_85 / I2C_SCL
I2C clock
51
I2C
GPIO_84 / I2C_SDA
I2C data
152
GND
GND
Ground
52
GND
GND
Ground
53
GND
GND
Ground
54
GND
GND
Ground
153
GND
GND
Ground
55
RF
ANT_PTRX1
Primary cellular signal input/output
154
GND
GND
Ground
56
GND
GND
Ground
155
GND
GND
Ground
57
GND
GND
Ground
156
GND
GND
Ground
58
GND
GND
Ground
_______________________________________________________________________________________________________________ Seite 12
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
157
GND
GND
Ground
59
MIPI
GPIO_46 / RFFE4_DATA
RF front end 4 interface data
158
GND
GND
Ground
60
GND
GND
Ground
159
GND
GND
Ground
61
MIPI
GPIO_47 /RFFE4_CLK
RF front end 4 interface clock
160
GND
GND
Ground
62
GND
GND
Ground
63
GND
GND
Ground
162
JTAG
MDM_JTAG_TDI
JTAG data input
64
GND
GND
Ground
163
JTAG
MDM_JTAG_TDO
JTAG data output
65
GND
GND
Ground
164
JTAG
MDM_JTAG_TMS
JTAG mode select input
66
GND
GND
Ground
165
JTAG
MDM_JTAG_TRST_N
JTAG reset
67
GND
GND
Ground
166
JTAG
MDM_JTAG_TCK
JTAG clock input
68
GND
GND
Ground
167
JTAG
MDM_JTAG_SRST_N
JTAG reset for debug
69
GND
GND
Ground
168
JTAG
MDM_JTAG_PS_HOLD
Power supply hold signal to PMIC
70
GND
GND
Ground
169
POWER
VREG_L6_1P8
1.8V output
71
GND
GND
Ground
170
GND
GND
Ground
72
RF
ANT_DRX1
Diversity cellular signal input/output
171
GND
GND
Ground
73
GND
GND
Ground
172
GND
GND
Ground
74
Reserved
Reserved
Reserved
173
GND
GND
Ground
75
GND
GND
Ground
174
GND
GND
Ground
76
GND
GND
Ground
175
GND
GND
Ground
77
GND
GND
Ground
176
GND
GND
Ground
78
RF
ANT_GNSS
GNSS signal input/output
_______________________________________________________________________________________________________________ Seite 13
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
79
GND
80
GND
Ground
GPIO_38 / GRFC12
177
GND
GND
Ground
81
GPIO
GPIO_69
Configurable I/O
178
GPIO_67 / EBI2_AD2/FBS_1
82
GND
GND
Ground
179
BOOT CONFIG
GPIO_36 / FORCED_USB_BOOT
Force USB boot control
83
GPIO
GPIO_8
Configurable I/O
180
GPIO
GPIO_83
Configurable I/O
84
GPIO
GPIO_9
Configurable I/O
181
85
GPIO_59 / NC
GND
182
86
Ground
GPIO_24 / EBI2_AD1/FBS_0
GPIO
183
87
GND
GPIO
184
GPIO_10
Configurable I/O
MDM_MODE_0
TBD
GPIO_11
Configurable I/O
MDM_MODE_1
TBD
88
GND
GND
Ground
185
PCIE
GPIO_65 / MDM_PCIE_WAKE_N
PCIe host wake
89
Reserved
Reserved
Reserved
186
PCIE
GPIO_61 / MDM_PCIE_RESET_N
PCIe host reset
90
GND
GND
Ground
187
PCIE
GPIO_64 / MDM_PCIE_CLKREQ_N
PCIe clock request
91
GND
GND
Ground
188
WLAN IF
WLAN_PWR_REQ
92
GND
GND
Ground
189
GPIO
GPIO_60
Configurable I/O
93
WLAN IF
WLAN_PWR_EN
Enable WLAN Power
190
GPIO
GPIO_68
Configurable I/O
94
WLAN IF
WLAN_SLP_CLK
191
BT IF
BT_RESET_N
Enable Bluetooth
PMD_RESIN_N
Reset module
GND
Ground
PON_1
Turn on module
GPIO_95 / WLAN_EN
Enable WLAN
Power-reset
95
PMIC (active
low)
192
96
193
GND
Power-on PMIC
(active high)
WLAN IF
97
194
CBL_PWR_N
WLAN IF
GPIO_52 / COEX_UART_TX
UART transmit data
_______________________________________________________________________________________________________________ Seite 14
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
98
MPP
PMIC_MPP_4
Multipurpose Pin
195
WLAN IF
GPIO_53 / COEX_UART_RX
UART receive data
99
MPP
PMIC_MPP_2
Multipurpose Pin
196
MPP
PMIC_MPP_6
Multipurpose Pin
100
GND
GND_TO_VPH
Ground
197
GND
GND_TO_VPH
Ground
101
POWER
VPH_POWER
External supply voltage
198
POWER
VPH_POWER
External supply voltage
102
POWER
VPH_POWER
External supply voltage
199
POWER
VPH_POWER
External supply voltage
103
POWER
GND_TO_VPH
Ground
200
GND
GND
Ground
104
HW_REV_RESISTOR
Note: Pins should be grounded when not used in design.
2.10 Supply Voltage
Absolute minimum/maximum supply voltages
Nominal supply voltage
Recommended supply voltage
Voltage drop @ GSM power burst (33dBm)
3.9V ~ 4.1V
4V
4V
<100mV
During Hi RF Power GSM bursts the power amplifier can draw peak currents > 2Amps at VMAIN. The
voltage drop during the GSM burst shall not exceed 100mV.
2.11 Power Consumption
TA = +25°C, VPH_PWR =3.8V
Voice
Voice
Voice
Voice
call
call
call
call
WCDMA
WCDMA
WCDMA
WCDMA
BC1
BC2
BC5
BC8
Voice call GSM850
Voice call GSM900
Voice call GSM1800
Voice call GSM1900
Output Power
Output Power
max. (typ. 23dBm)
~530mA
~570mA
~630mA
~580mA
0 dBm
~145mA
~145mA
~140mA
~140mA
PCL 5 (typ. 32.5 dBm)
~260mA
~270mA
PCL 0 (typ.30.5dBm)
~165mA
~165mA
PCL 19 (typ. 5dBm)
~65mA
~65mA
PCL 15 (typ.0dBm)
~65mA
~65mA
_______________________________________________________________________________________________________________ Seite 15
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Output Power
Standby current GSM
Standby current WCDMA
Standby current LTE
DRX = 5
DRX = 7
DRX = 7
Output Power
Tbd mA
Tbd mA
LTE data call B3
LTE data call B7
LTE data call B20
2.12 Environmental Specification
2.12.1 Temperature Range
Range
Operating temp. range
Extended operating temp. range
-25°C … +70°C
-40°C … +85°C
Storage temp. range
-40°C … +85°C
Note 1
3GPP spec. conform
Operational
Performance might slightly
deviate from 3GPP spec.
Note 1: Due to temperature specification of the chipset, the temperature of the power manager and the
temperature of the modem chip shall not exceed +85°C.
_______________________________________________________________________________________________________________ Seite 16
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
3
Evaluation Kit
There are two types of evaluation boards fitted with the NAD V123x-0 modules:

The IFB-1 board allows to power-supply the module directly with external 4V along with sense
signals. This 4V power-supply should be able to deliver 3.5A max.

The IFB-4 board type takes 12V as input voltage, down-converted to 4V by on-board circuitry.
Features:
USB 2.0 (micro USB) for USB to UART
USB 3.0 (micro b)
2*SIM card slot
Audio support with microphone and loudspeaker connectors
JTAG connector for debug and programming
5 RF Antenna connector (PTRX,DRX,GNSS,WL,BT)
2* RS232 for UART 1 & 4
_______________________________________________________________________________________________________________ Seite 17
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
RF Connectors
For Cellular RF measurements, use the PTRX and DRX antenna ports
GNSS
DRX
PTRX
Figure 1 Evaluation Kit for V123x-0.
BT
WLAN
_______________________________________________________________________________________________________________ Seite 18
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
ON/OFF switch
Only for 12 V supply
12 V DC Supply
(Top Connector positive, bottom connector ground)
Figure 2 Power supply for Evaluation Kit for V123x-0.
SIM slot 1(bottom)/2(Up)
Figure 3 SIM card and USB interfaces for Evaluation Kit for V123x-0.
USB 3port
Micro USB 2.0
USB to UART
_______________________________________________________________________________________________________________ Seite 19
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
4
AT Command interface
The modules supports standard AT command as listed below. Commands are compliant to 3GPP TS
27.007 and TS 27.005
Command
Description
AT+CMGF
AT+CSCA
AT+CMGS
AT+CGMI
AT+CGMM
AT+CGMR
AT+CGSN
Message Format
Service Centre Address
Send Message
Manufacturer Identification
Request model identification
Request revision identification
Request product serial number
Request international mobile subscriber
identification
Call mode
AT+CIMI
AT+CMOD
AT+CHUP
ATD
ATA
ATH
AT+CBST
AT+CEER
AT+CVHU
AT+CREG
AT+COPS
AT+CLCK
AT+CPWD
AT+CLIP
AT+CLIR
AT+CCWA
AT+CHLD
AT+CUSD
AT+CLCC
AT+CPOL
AT+CPAS
AT+CFUN
AT+CPIN
AT+CSQ
AT+CMER
AT+CSIM
AT+CRSM
AT+CMEE
AT+CGDCONT
AT+CGEQREQ
AT-CGATT
AT+CGACT
AT+CGPADDR
AT+CGSMS
ATE
Comment
Only one Parameter is supported by the
device.
Hang up call
Initiate a CS or PS call or supplementary service
Answer incoming CS call command
Hangup CS call command
Select bearer service type
Extended error report
Voice hangup control
Network registration
PLMN selection
Facility lock
Change password
Calling line identification presentation
Calling line identification restriction
Call waiting
Call related supplementary services
Unstructured supplementary service data
List current calls
Preferred PLMN list
Phone active status
Set phone functionality
Enter PIN
Signal quality
Mobile termination event reporting
Generic SIM access
Restricted SIM access
Report mobile termination error
Define PDP context
Request 3G quality of service profile
PS attach or detach
PDP context activate or deactivate
Show PDP address
Select service for MO SMS messages
Character Echo ON/OFF
_______________________________________________________________________________________________________________ Seite 20
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Command
Description
AT+CSMS
AT+CSMP
AT+CSDH
AT+CSCB
Check Message Service support
Set Text Mode Parameters
Show Text Mode Parameters
Select Cell Broadcast Message Types
Save Settings
AT+CSAS
AT+CRES
AT+CMGL
AT+CNMA
AT+CMGC
AT+CMMS
AT+ATV
AT+ATX
AT+CNMI
AT+CPMS
AT+CMGW
AT+CMSS
AT+CMGD
AT+CNUM
AT+CPBS
AT+CPBR
AT+CPBW
Comment
Restore Settings
Only one Parameter is supported by the
device.
Only one Parameter is supported by the
device.
List messages
New message acknowledgement
Send Command
More Messages to Send
DCE response format
Result code selection and call progress
monitoring control
New Message Indications to TE
Preferred Message Storage
Write Message to Memory
Send Message from Storage
Delete Messages
Get MSISDN
Select phonebook memory storage
Read phonebook entries
Writephonebook entry
_______________________________________________________________________________________________________________ Seite 21
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
5
Safety Recommendations according to EN60950-1
The V123x-0 devices must be supplied by a limited power source according to EN 60950-1.
The clearance and creepage distances required by the end product must be withheld when the module
is installed.
The cooling of the end product shall not negatively be influenced by the installation of the module.
_______________________________________________________________________________________________________________ Seite 22
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
6
RED/FCC/IC Regulatory Notices
6.1 Modifications
WARNING: peiker acustic GmbH & Co. KG has not approved any changes or modifications to
the V123x-0 device by the user. Any changes or modifications could void the user’s authority to
operate the equipment.
6.2 Interference
V1231-0 and V1233-0 devices comply with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
(1) Those devices may not cause harmful interference, and
(2) Those devices must accept any interference received, including interference that may cause
undesired operation.
V1231-0 is a Class b digital apparatus compliant with Canadian ICES-003.
V1231-0 est un appareil numérique de la classe b conforme à la norme NMB-003 du Canada.
V1231-0 est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
6.3 FCC Class B Digital Device
V1231-0 has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
_______________________________________________________________________________________________________________ Seite 23
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
6.3 OEM Responsibilities
Antenna
The systems antenna(s) must be installed such that 20 cm is maintained between the
antenna(s) and the body of the user or nearby persons.
The V123x-0 transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter. The preceding statement must be included as a Caution
statement in OEM product manuals in order to alert users of FCC RF Exposure
compliance.
Maximum authorized antenna gain: refer to the MPE test reports
Power Supply
The power supply of the host device embedding a V123x-0 module must fulfill the
following requirements:
o Nominal supply voltage: 4V
o Operating voltage range: 3.9V – 4.1V
o The above operating voltage range MUST never, under any circumstances
(including overshoot voltage and voltage drop), be exceeded.
FCC Labeling
Labeling requirements for a host device embedding V1231-0:
V1231-0 is labeled with its own FCC ID Number. If the FCC ID is not visible when V12310 is installed inside another device, then the host device must contain the FCC ID number
with the statement such as the following: "Contains Transmitter Module FCC ID: QWYV1231-0" or "Contains FCC ID: QWY-V1231-0"
Labeling requirements for a host device embedding V1233-0:
V1233-0 is labeled with its own FCC ID Number. If the FCC ID is not visible when V12330 is installed inside another device, then the host device must contain the FCC ID number
with the statement such as the following: "Contains Transmitter Module FCC ID: QWYV1233-0" or "Contains FCC ID: QWY-V1233-0"
IC Labeling
Labeling requirements for a host device embedding V1231-0:
V1231-0 is labeled with its own IC ID Number. If the IC ID is not visible when V1231-0 is
installed inside another device, then the host device must contain the IC ID number with
the statement such as the following: "Contains Transmitter Module IC 6588A- V12310" or
"Contains IC 6588A- V12310".
_______________________________________________________________________________________________________________ Seite 24
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
7
List of Acronyms
3GPP
ADC
ADN
A-GPS CP
AMR
AT
AWS
BER
CLIP
CLIR
CSD
DARP
EDGE
DTMF
FCC
FDN
FTP
GCF
GSM
GPIO
GPRS
GPS
HSPA
HW
IC
LED
LTE
MO
MT
OEM
PCB
PCM
PDU
PIN
PTCRB
RF
RoHs
UART
USB
USIM
UMTS
WCDMA
3 rd Generation Partnership Project
Analog Digital Converter
Abbreviated Dialing Number
Assisted GPS Control Plane
Adaptive Multi Rate
Attention Command
Advanced Wireless Services
Bit Error Rate
Calling Line Identification Presentation
Calling Line Identification Restriction
Circuit Switch Data
Downlink Advanced Receiver Performance
Enhanced Data rates for GSM Evolution
Dual Tone Multi Frequency
Federal Communications Commission
Fixed Dialing Number
File Transfer Protocol
Global Certification Forum
Global System for Mobile communication
General Purpose Input Output
General Packet Radio Service
Global Positioning System
High Speed Uplink Packet Access
Hardware
Industry Canada
Led Emitting Diode
Long-Term Evolution
Mobile Originated
Mobile Terminated
Original Equipment Manufacturer
Printed Circuit Board
Pulse Code Modulation
Protocol Data Unit
Personal Identification Number
PCS Type Certification Review Board
Radio Frequency
Restriction of Hazardous Substances
Universal Asynchronous Receiver and Transmitter
Universal Serial Bus
Universal Subscriber Identity Module
Universal Mobile Telecommunications System
Wideband Code Division Multiple Access
_______________________________________________________________________________________________________________ Seite 25
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 25
Language                        : en-US
Tagged PDF                      : Yes
Author                          : PEIKER acustic
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2017:09:04 17:21:58+02:00
Modify Date                     : 2017:09:04 17:21:58+02:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QWY-V1231-0

Navigation menu