Pelco Cm6700 Users Manual Matrix Switcher Controller_manual
CM6700 to the manual 1b009148-4c28-432f-876c-796064c286d9
2015-02-02
: Pelco Pelco-Cm6700-Users-Manual-441565 pelco-cm6700-users-manual-441565 pelco pdf
Open the PDF directly: View PDF .
Page Count: 44
Download | |
Open PDF In Browser | View PDF |
® CM6700 Matrix Switcher/Controller Installation/ Operation Manual C523M-H (6/05) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150 International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3 MODELS ............................................................................................................................ 4 ASSOCIATED EQUIPMENT ...................................................................................... 4 DESCRIPTION ................................................................................................................... 5 INSTALLATION .................................................................................................................. 8 SET OPTIONS ........................................................................................................... 8 MOUNT UNIT ............................................................................................................. 9 CONNECT VIDEO SOURCES ................................................................................. 10 CONNECT CONTROL LINES ................................................................................... 11 CONNECT MONITORS ............................................................................................ 13 CONNECT ALARMS ................................................................................................. 14 CONNECT AUXILIARIES ......................................................................................... 15 CONNECT COM 2 PORT ......................................................................................... 17 CONNECT KEYBOARDS ......................................................................................... 18 PROGRAMMING .............................................................................................................. 20 OPERATION ..................................................................................................................... 36 ASCII OPERATING COMMANDS ............................................................................ 36 TROUBLESHOOTING ...................................................................................................... 39 GAINING INITIAL CONTROL ................................................................................... 39 USING A PC TO SEND ASCII COMMANDS VIA COM 2 ......................................... 39 PERFORMING A SOFTWARE RESET ..................................................................... 39 SPECIFICATIONS ............................................................................................................. 41 INDEX ............................................................................................................................... 43 REGULATORY NOTICES ......................................................................................... 44 WARRANTY AND RETURN INFORMATION .................................................................... 44 LIST OF ILLUSTRATIONS Figure 1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 16 17 18 19 20 21 Page CM6700 Applications ......................................................................................... 6 Application with a Multiplexer ............................................................................. 7 Applications with Remote Keyboards (ASCII, KBD200A Only) .......................... 7 Cover Removal .................................................................................................. 8 Video Termination Jumpers ................................................................................ 8 DIP Switch Locations ......................................................................................... 9 Installing Mounting Ears ..................................................................................... 9 Mounting the Matrix Switcher ............................................................................ 10 Connecting Video Sources ................................................................................ 10 Daisy-Chaining Receivers ................................................................................. 11 COM 1 Connections on the SCU ...................................................................... 11 Making Receiver Connections at a Distribution Block (CM9760-CDU-T) ......... 12 Monitor Connections ......................................................................................... 13 Connecting Alarms ............................................................................................ 14 Wiring the AUX 1 (Relay) Output ...................................................................... 15 Wiring the AUX 2 and AUX 3 (TTL) Outputs ..................................................... 16 Connecting an RS-232 Interface ....................................................................... 17 Connecting an RS-422/485 Interface ................................................................ 17 Installing Local and Remote Keyboards ........................................................... 18 Quick Reference Chart ..................................................................................... 21 Software Reset Button Location ....................................................................... 39 LIST OF TABLES Table A B C D E F 2 Page Keyboard Addresses ......................................................................................... 19 Programming the CM6700 Switching Control Unit ........................................... 20 Examples of ASCII Commands ......................................................................... 36 ASCII Commands ............................................................................................. 37 Solutions To Common Problems ....................................................................... 40 Switcher/Controller and Keyboard RJ-45 Pin Functions ................................... 40 Pelco Manual C523M-H (6/05) IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. This unit is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. The installation method and materials should be capable of supporting four times the weight of the unit and equipment. 4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry. The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Pelco Manual C523M-H (6/05) 3 MODELS CM6700-MXB2 Matrix switcher/controller with 16 video inputs and 2 monitor outputs, 120 VAC, 50/60 Hz CM6700-MXB2-X Same as CM6700-MXB2, PAL-configured for 230 VAC and 50 Hz operation CM6700-MXB4 Same as CM6700-MXB2 with two-monitor expansion card (CM6700VMC2) pre-installed CM6700-MXB4-X Same as CM6700-MXB4, PAL-configured for 230 VAC and 50 Hz operation ASSOCIATED EQUIPMENT 4 KBD100 Desktop keyboard with full switching and programming capabilities KBD200A Desktop keyboard with full switching and programming capabilities, plus push-button control of PTZ functions KBD300A Desktop keyboard with full switching and programming capabilities, plus joystick control of PTZ functions CM6700-VMC2 Expansion card with two monitor outputs CM6700-VMC2-X Expansion card with two monitor outputs, PAL-configured KBDKIT Wiring kit for connecting KBD100, KBD200A, and KBD300A keyboards to remote keyboard port; includes two RJ-45 wall blocks and a transformer to convert 120 VAC to 12 VAC for keyboard power KBDKIT-X Wiring kit for connecting KBD100, KBD200A, and KBD300A keyboards to remote keyboard port; includes two RJ-45 wall blocks and a transformer to convert 230 VAC to 12 VAC for keyboard power CM9760-CDU-T This is a 16-channel RS-422 transmit-only (two-wire and ground) distributor that is used primarily to install pan and tilt and dome receivers in a star configuration. Pelco Manual C523M-H (6/05) DESCRIPTION Pelco’s CM6700 is a keyboard-controlled cross-point video matrix switcher/control unit (SCU) that allows you to route up to sixteen video images to as many as four monitors while controlling camera positions. Applications The CM6700 SCU can be controlled from a local or remote keyboard (refer to Figure 1), used with a multiplexer to display multiple camera views on a monitor (refer to Figure 2), and interfaced to a distant keyboard via dial-up telephone circuits through appropriate interface equipment (refer to Figure 3). The CM6700 features menu-driven, password-protected programming. The CM6700 can also be controlled from a personal computer using ASCII commands. Keyboards Camera positioning options can be programmed and controlled from a keyboard. Up to eight keyboards can be connected to the CM6700 SCU, allowing monitoring stations that share a common monitor to each have a keyboard. Four different keyboards are available to use with the CM6700 SCU, each with varying features and different costs. (Keyboard types can be mixed in a system – See Associated Equipment.) Sequences, Presets, and Patterns Special programmed operations include sequences, presets and patterns. A sequence allows you to see a routine of 16 camera views on your monitor over and over again. The sequence can be operated automatically or manually. The order in which the views appear and the time each view remains can be programmed. A preset allows you to direct a pan/tilt/zoom (camera positioning system) to move to a certain position on command or as a result of an alarm. In addition to moving the camera, a descriptive title can appear on the screen. (Presets are not available with the KBD100 keyboard.) With a pattern you can program a camera positioning system to move around its viewing area in a repeating pattern. The number and time length of patterns varies with different positioning systems. (Patterns are not available with the KBD100 keyboard.) Alarm Inputs Eighteen alarm inputs are provided. These can be programmed to cause the display to switch automatically to the camera with the alarm and/or to operate one of three auxiliary outputs. Sixteen of the inputs are associated with individual cameras. Two of the inputs activate group camera sequences. Auxiliary Outputs Three auxiliary outputs are provided. One output is a relay and two are open collector (TTL) outputs. Auxiliary outputs are activated at the keyboard (except KBD100). Protocols The CM6700 works with Pelco’s Coaxitron®‚ D, and P protocol receivers. Power, Mounting Methods The CM6700 SCU operates on 120 VAC or 230 VAC, depending on the model. The compact case mounts in 3-1/2 inches of vertical space in a 19-inch equipment bay or to a wall or table top. Pelco Manual C523M-H (6/05) 5 COAXITRON RCVR SHIELDED TWISTED PAIR RS-422 (P OR D) COAXITRON TO ALARM CONTACTS VIDEO INPUTS 1 3 5 7 9 RS-232 TO PC OR CARD ACCESS COMPUTER VIDEO OUTPUTS LOCAL KEYBOARD 1 CM6700 SCU DAISY-CHAIN TO OTHER RECEIVERS 1 13 15 2 3 2 4 6 8 10 12 14 16 4 RS-485 12 VAC TRANSFORMER WALL BLOCK DATA CABLE KBD100/200A/300A REMOTE KEYBOARDS LOCAL KEYBOARD 00044 Figure 1. CM6700 Applications 6 Pelco Manual C523M-H (6/05) CAMERA VIDEO MULTIPLEXER MULTIPLEXED VIDEO LOOPED VIDEO INPUTS * VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 11 13 15 2 3 2 4 6 8 10 12 14 16 4 CM6700 SCU * MULTIPLEXER MULTIPLEXED *ALTERNATE VIDEO ROUTING THROUGH A CAMERA INPUT. KBD200A/300A 00045 Figure 2. Application with a Multiplexer VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 1 13 15 2 3 2 4 6 8 10 12 14 16 4 RS-422 FACILITY (FIBER OPTIC TERMINAL, ETC.) TO REMOTE KEYBOARD (ASCII) NOTE: ASCII DOES NOT SUPPORT PROGRAMMING FOT = FIBER OPTIC TERMINAL KBD200A CONTROL FOT (VIDEO+) FOT (VIDEO+) MONITOR VIDEO RS-232 FACILITY (PELCOVISION, ETC.) TO REMOTE KEYBOARD (ASCII) CONTROL KBD200A TRANSMITTER RECEIVER PSTN VIDEO 00046 MONITOR Figure 3. Applications with Remote Keyboards (ASCII, KBD200A Only) Pelco Manual C523M-H (6/05) 7 INSTALLATION 1 SET OPTIONS 1. Refer to Figure 4. Remove the cover. B C A REMOVE 6 SCREWS LIFT COVER OFF REMOVE 6 SCREWS 00055 Figure 4. Cover Removal 2. Refer to Figure 5. Set jumpers according to your system requirements. JP1-JP16 are used to terminate the video input with a 75-ohm resistor or to unterminate the video (looping). The factory default has the jumper installed in the terminating position. If you are connecting only a camera to an input, leave the jumper in the terminating position. If you are looping the video to another device, move the jumper to the looped position, and terminate at the equipment connected to the looping output. 75-OHM TERMINATION JUMPER KEY TERMINATED LOOPED 75-OHM TERMINATION JUMPERS (ONE PER INPUT) BACK OF SCU JP1 ON 1 2 3 4 JP16 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 NOTE: JUMPER JP1 CORRESPONDS TO VIDEO INPUT 1, JP2 TO VIDEO INPUT 2, ETC. Figure 5. Video Termination Jumpers 8 Pelco Manual C523M-H (6/05) 3. Refer to Figure 6. Set DIP switches. a. Communication port 2 is available for a PC or remote keyboard operating in ASCII mode. (Refer to ASCII Operating Commands.) Most PC applications require RS-232. A remote keyboard can require either RS-232 or RS-422, depending on the communications facility. To find out the required interface, check your PC serial port information or refer to your keyboard manual. Set DIP switch SW5 (COM 2) for RS-232 or RS-422, according to your system requirements. The SCU is configured at the factory for RS-422. b. DIP switches SW1, SW2, SW3 and SW4 are to remain in the factory default position (OFF). c. DIP switch SW6 (COM1) is to remain in factory default position (RS-422). SW6 DEFAULTS TO RS-422 3c 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON ON ON 1 2 3 4 POWER TERMINAL BLOCK 3a RS-422/485 RS-232 ON 1 2 3 4 5 6 7 8 ON HIGH VOLTAGE 1 2 3 4 ON 1 2 3 4 3b SW5 & 6 DIP SWITCH SETTINGS 1 2 3 4 5 6 7 8 FUSE ON 1 2 3 4 KEY ON OFF 00054 TRANSFORMER Figure 6. DIP Switch Locations 4. 2 Replace cover. MOUNT UNIT 1. Select a suitable location for the SCU. It must be within 6 feet (1.8 m) of a suitable electrical outlet. Do not connect the power yet. 2. Refer to Figure 7. Position mounting ears on the sides of the SCU for the appropriate mounting. If the ears are not required, leave them off. POSITION BRACKETS FOR RACK MOUNTING (REAR) POSITION BRACKETS FOR UNDER-TABLE MOUNTING POSITION BRACKETS FOR FLUSH MOUNTING (WALL OR TABLE TOP) NOTE: EACH SCU COMES WITH 2 MOUNTING BRACKETS Figure 7. Installing Mounting Ears Pelco Manual C523M-H (6/05) 9 3. Refer to Figure 8. Use suitable hardware to mount the SCU an in equipment bay or against a flat surface, according to your installation requirements. MOUNT TO RACK OR SURFACE WITH 4 SCREWS Figure 8. Mounting the Matrix Switcher 3 CONNECT VIDEO SOURCES Refer to Figure 9. Connect video cables at the appropriate BNC receptacles on the back of the SCU. CAMERA 15 CAMERA 1 CM6700 SCU VIDEO INPUTS 1 3 5 7 9 VIDEO OUTPUTS 11 13 1 ALARMS (1-9) 2 ALARMS (10-18) 3 COM 1 (1-6) COM 2 ( 7-12) LOCAL KEYBOARD 1 2 15 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 2 4 6 8 10 12 14 1 2 3 4 5 16 4 6 7 8 9 REMOTE KEYBOARD(S) 10 11 12 T T + R R + CONTROL OUTPUTS 0 1 2 3 F 2 F N N C 3 O C O M LOOPING OUT Figure 9. Connecting Video Sources 10 Pelco Manual C523M-H (6/05) 4 CONNECT CONTROL LINES NOTE: If D or P protocol 1. receivers are used, they must all be the same protocol. D and P protocol receivers cannot be mixed on the SCU’s communication port. Coaxitron control may be used for some of your sources when either D or P protocol receivers are used. Connect camera control lines to receivers. If your video sources are all controlled by Coaxitron, skip this section and go to step 5 . If any of your video sources are using D or P protocol via RS-422 communications circuits, they will connect at COM 1 on the back of the SCU, as outlined below. 2. Refer to Figure 10. Connect control lines to COM 1 at the connector on the back of the SCU. VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 1 13 COM 1 (1-6) 15 2 3 2 4 6 8 10 12 14 16 RS-422 4 PIN ASSIGNMENTS COM 1 (1-6) COM 2 (7-12) PIN FUNCTION 1 T+ 2 T– NOTE: TO PROPERLY SHIELD DATA CABLE CONNECT GROUND ON ONE END ONLY 12-PIN PLUG-IN CONNECTOR 3 (OPTIONAL) GND CONNECT PINS 5 & 6 ONLY IF USING BI-DIRECTIONAL CONTROL 4 NC 5 R– 6 R+ TO RECEIVERS 00052 Figure 10. COM 1 Connections on the SCU 3. NOTE: Unless you have receivers that are equipped for bi-directional control, you will only need to run two wires (TX+ and TX-) to each receiver. Connect wiring to all receivers. a. Daisy-chaining (going from one receiver to another) is recommended (refer to Figure 11) but not always possible. VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 1 13 15 2 3 2 4 6 8 10 12 14 16 4 COM 1 (1-6) COM 2 (7-12) NOTE: TO PROPERLY SHIELD DATA CABLE CONNECT GROUND ON ONE END ONLY 12-PIN PLUG-IN CONNECTOR RECEIVER 2 DAISY-CHAINING RECEIVER 1 RX+ RX+ RX- RX- CONNECT PINS 5 & 6 ONLY FOR BI-DIRECTIONAL CONTROL TO SCU TO ADDITIONAL RECEIVERS 00050 Figure 11. Daisy-Chaining Receivers Pelco Manual C523M-H (6/05) 11 b. A star configuration (going to each receiver from a central connecting point) is sometimes more practical. Your installation will be easier to maintain and troubleshoot if you make all connections at a distribution block made of barrier terminals or at a Pelco CM9760-CDU-T distribution panel (refer to Figure 12). The total length of all control lines combined should not exceed 4,000 feet (1,219 m). VIDEO INPUTS 3 5 7 11 9 13 LOCAL KEYBOARD ALARMS (1-9) 1 2 3 4 5 6 7 8 9 15 ALARMS (10-18) 2 10 11 1213 14 15 16 17 18 4 6 8 10 12 14 1 2 3 4 5 6 7 8 9 REMOTE KEYBOARD(S) COM 1 (1-6) COM 2 (7-12) 3 2 LOCAL KEYBOARD ALARMS (1-9) VIDEO OUTPUTS 1 1 1 2 3 4 5 6 7 8 9 10 11 12 16 T T + R R + CONTROL OUTPUTS 4 0 1 2 3 F 2 F N N C 3 O C O M ALARMS (10-18) NOTE: TO PROPERLY SHIELD DATA CABLE REMOTE KEYBOARD(S) 10 11 1213 14 15 16 17 18 RECEIVER 2 CONNECT GROUND ON END ONLY. T TONE R R COM 1 (1-6) COM 2 (7-12) NOTE: USE CM9760-CDU-T CONTROL ONLY WITH OUTPUTS 2-WIRE CONTROL. RECEIVER 1 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 F 2 + + F N N C 3 O C O M TO SCU 100-240V 1 Tx+ TxGnd 2 Tx+ TxGnd 3 Tx+ TxGnd 4 Tx+ TxGnd 5 Tx+ TxGnd 6 Tx+ TxGnd 7 Tx+ TxGnd 8 Tx+ TxGnd 9 Tx+ TxGnd 10 Tx+ TxGnd 11 Tx+ TxGnd 121 Tx+ TxGnd 13 Tx+ TxGnd 14 Tx+ TxGnd 15 Tx+ TxGnd 16 Tx+ TxGnd OUT IN 10-24 AC/DC Figure 12. Making Receiver Connections at a Distribution Block (CM9760-CDU-T) 12 Pelco Manual C523M-H (6/05) 5 CONNECT MONITORS 1. Your SCU will support either two or four monitors. Models CM6700-MXB4 and CM6700-MXB4-X support four monitors (Monitors 1-4). Models CM6700-MXB2 and CM6700-MXB2-X support two monitors (Monitor 1 and 2). A CM6700-VMC2 expansion card can be added to the CM6700-MXB2 or a CM6700-VMC2-X to the CM6700-MXB2-X to increase the support to four monitors. 2. Install monitors according to the instructions provided with them. 3. Refer to Figure 13. Connect the monitor cables at the appropriate BNC receptacle on the back of the SCU. 4. Be sure to terminate cables properly at the monitors. VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 CM6700 SCU 1 3 5 7 9 1 13 15 2 3 2 4 6 8 10 12 14 16 4 75 Ω MONITOR 4b LOOPING MONITOR 4a 75 Ω MONITOR 3 75 Ω MONITOR 2 75 Ω MONITOR 1 00049 Figure 13. Monitor Connections Pelco Manual C523M-H (6/05) 13 6 CONNECT ALARMS 1. Refer to Figure 14. Alarm inputs 1-16 correspond to video inputs 1-16. If an open door sensor is connected to alarm input 1, when the sensor is activated the video image from camera 1 will be displayed on one of the four monitors and the camera will move to a preset (determined by programming). Alarm sensors can be either N.O. or N.C. contacts. Connect wires from the sensors to the respective alarm input points on the connectors at the back of the SCU. Each sensor requires one wire to the alarm input terminal and a return wire to one of the ground terminals on the connector. 2. Alarm inputs 17 and 18 correspond to group sequences 1 and 2. During a group sequence four video inputs are sequentially shown on a monitor. Each of the four monitors can be programmed to show the images from four different video sources. An alarm sensed at input 17 or 18 causes the respective group sequence to operate. Connect sensors for these two alarm inputs as described in step 1 above. CAMERA 1 VIDEO INPUT CORRESPONDS TO ALARM INPUT VIDEO INPUTS VIDEO OUTPUTS 1 1 3 5 7 9 1 13 LOCAL KEYBOARD 15 2 3 2 4 6 8 10 12 14 16 4 12-PIN TERMINAL STRIP ON REAR OF SCU ALARMS (1-9) ALARMS (10-18) (10) (12) (14) (16) (18) (11) (13) (15) (17) 12-PIN PLUG-IN CONNECTOR TO ALARM SOURCE 00047 Figure 14. Connecting Alarms 14 Pelco Manual C523M-H (6/05) 7 CONNECT AUXILIARIES The SCU provides three auxiliary (AUX) outputs for controlling VCRs and other devices. These outputs can be activated directly from a keyboard by using the F1, F2, and F3 function keys, or they can be activated by an alarm (determined by programming). Both relay contacts and TTL outputs are used. a. AUX 1 is a dry contact relay output. Refer to Figure 15 for wiring details. Terminal connections are provided for both normally open (N.O.) and normally closed (N.C.) contacts. Do not exceed the voltage and current ratings for the relay contacts. You will need to provide an external power source to operate your device. In most cases you will also need an external current limiting resistor. The formula for calculating the resistor value is given in Figure 15. b. AUX 2 and 3 are TTL open collector outputs. These outputs provide a path to ground to control the low voltage trigger inputs on many devices. They can control higher voltage control inputs via isolation relays. Refer to Figure 16 for wiring details. Do not exceed the voltage and current ratings for the TTL outputs. An external pull-up resistor is usually necessary. The formula for calculating the resistor value is given in Figure 16. VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 1 13 15 2 3 2 4 6 8 10 12 14 16 4 12-PIN TERMINAL STRIP ON REAR OF SCU F1 RELAY CONTACT RATINGS CURRENT CONTROL OUTPUTS VOLTAGE 1A NOT USED 30 VDC 0.3 A 11 VDC 0.5 A 125 VAC 12-PIN PLUG-IN CONNECTOR EXTERNAL DEVICE Io PIN 1 Vo R +VPS NOTE: Io MUST NOT EXCEED FI CURRENT RATING. +VPS MUST NOT EXCEED FI VOLTAGE RATING FOR THE ASSOCIATED FI CURRENT. VPS CAN BE AC OR DC. Io Vo R +VPS -VPS -VPS = OPERATING CURRENT OF THE EXTERNAL DEVICE. = RATED OPERATING VOLTAGE OF THE EXTERNAL DEVICE. = CURRENT LIMITING RESISTOR. = VOLTAGE OF THE EXTERNAL POWER SOURCE. = NEGATIVE, COMMON OR GROUND TERMINAL OF EXTERNAL POWER SOURCE. FORMULAS FOR R VALUES R (OHMS) = P (WATTS) = VPS - Vo Io (Io)2 X R *WIRING FOR NORMALLY OPEN TYPE CONTACTS SHOWN. FOR NORMALLY CLOSED TYPE CONTACT, MOVE WIRE FROM THE NO TERMINAL TO THE NC TERMINAL. 00048 Figure 15. Wiring the AUX 1 (Relay) Output Pelco Manual C523M-H (6/05) 15 VIDEO INPUTS VIDEO OUTPUTS 1 1 3 5 7 9 1 13 LOCAL KEYBOARD 15 2 3 2 4 6 8 10 12 14 16 4 12-PIN TERMINAL STRIP ON REAR OF SCU CONTROL OUTPUTS +VDC NOT USED R = +VDC 25 mA R 12-PIN PLUG-IN CONNECTOR DEVICE, EX. VIDEO PRINTER INPUT FROM VIDEO OUTPUT LOOPED TO MONITOR +VDC = VOLTAGE OF THE EXTERNAL POWER SOURCE NOTE: +VDC SHOULD BE 5 V OR GREATER, BUT NOT EXCEED 32 V OR THE MAXIMUM RATED OUTPUT VOLTAGE FOR THE DEVICE INPUT. +VDC CAN ONLY BE DC. Figure 16. Wiring the AUX 2 and AUX 3 (TTL) Outputs 16 Pelco Manual C523M-H (6/05) 8 NOTE: If you are using a PC at COM 2, refer to the Troubleshooting section. CONNECT COM 2 PORT You will need to use the COM 2 port if your system includes an ASCII control device, such as a personal computer or a keyboard that is connected via dial-up lines or fiber optic network. The port interface at COM 2 can be either RS-232 or RS-422/485. The DIP switches should have been set (refer to Figure 6). a. If you require an RS-232 port interface, connect wires from the RS-232 device to the COM 2 terminals at the back of the SCU. Refer to Figure 17. b. If you require an RS-422/485 port interface, connect wires from the RS-422 device to the COM 2 terminals at the back of the SCU. Refer to Figure 18. VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 1 13 15 2 3 2 4 6 8 10 12 14 16 4 12-PIN TERMINAL STRIP ON REAR OF SCU COM 2 (7-12) COM 1 (1-6) COM 2 (7-12) RS-232 PIN ASSIGNMENTS 12-PIN PLUG-IN CONNECTOR TX+ GND RX+ TO EXTERNAL DEVICE 10 PIN FUNCTION 7 T+ 8 SPARE 9 GND 10 SPARE 11 SPARE 12 R+ Figure 17. Connecting an RS-232 Interface VIDEO INPUTS VIDEO OUTPUTS LOCAL KEYBOARD 1 1 3 5 7 9 1 13 15 2 3 2 4 6 8 10 12 14 16 4 12-PIN TERMINAL STRIP ON REAR OF SCU COM 2 (7-12) COM 1 (1-6) COM 2 (7-12) RS-422/485 PIN ASSIGNMENTS TO EXTERNAL DEVICE RXRX+ TX+ TXGND 12-PIN PLUG-IN CONNECTOR 10 PIN FUNCTION 7 T+ 8 T- 9 GND 10 SPARE 11 R- 12 R+ Figure 18. Connecting an RS-422/485 Interface Pelco Manual C523M-H (6/05) 17 9 CONNECT KEYBOARDS Pelco offers three keyboard models for use with the CM6700 matrix switcher. Complete installation instructions are provided with each keyboard. The most common connections are for local and remote keyboards. The procedures for installing local and remote keyboards are repeated here. Refer to the keyboard manual for the less common ASCII connection (KBD200A only). Do the following to install. Refer to Figure 19. 1. If you are not installing any other keyboards, go to the Programming section. To install remote keyboards, complete steps 2-10. NOTE: A KBDKIT or KBDKIT-X is required to connect remote keyboards. The KBDKIT consists of two RJ-45 wall blocks and one 120 VAC to 12 VAC transformer. The KBDKIT-X is for 230 VAC. Use one wall block for each keyboard. Local keyboard. Using the data cable that is supplied with the keyboard, plug one end into the RJ-45 connector on the rear of the keyboard and plug the other end into the LOCAL KEYBOARD port on the SCU. Set the keyboard DIP switch for the desired address for the local keyboard (refer to Table A). 2. Select a suitable location for each keyboard and wall block. Wall blocks must be within 6 feet (1.8 m) of a suitable electrical outlet. Do not mount the wall block yet. 3. Run wall block interconnect cable (user-supplied) from the SCU to the closest keyboard location, and then to the next nearest location, and the next, etc. Communication to the keyboards is RS-485. Maximum total cable distance for RS-485 communication over 24-gauge wire is 4,000 feet (1,219 m). Pelco recommends using shielded twisted pairs cable that meets or exceeds the basic requirements for EIA RS-485 applications. 4. Remove the wall block cover and make cable connections at each wall block. 5. At each wall block, wire the transformer to pins 3 and 4. Polarity is unimportant. 6. Replace the cover on the wall block. Secure the wall block to a suitable surface. A double-sided sticky pad is provided to mount the wall block. 7. Set the address switches for each keyboard according to Table A. KBD CM6700 SCU LOCAL KEYBOARD LOCAL KEYBOARD 25-FOOT KEYBOARD DATA REMOTE KEYBOARD(S) USER-SUPPLIED CABLE TO REMOTE KEYBOARDS WALL BLOCK TERMINALS WALL BLOCK TERMINALS 4 5 4 5 3 6 3 6 2 7 2 7 1 8 1 8 REMOTE KEYBOARD 12 VAC 25-FOOT KEYBOARD DATA CABLE GND TXTX+ TO ADDITIONAL RX+ KEYBOARDS RX- REMOTE KEYBOARD 12 VAC 25-FOOT KEYBOARD DATA CABLE Figure 19. Installing Local and Remote Keyboards 18 Pelco Manual C523M-H (6/05) 8. Plug in all keyboard data cables. 9. Plug the KBDKIT or KBDKIT-X transformers into a suitable outlet and apply power to the SCU. NOTE: You must re-initialize whenever power is cycled. 10. To initialize a keyboard, wait five seconds after power-up, enter the number for the monitor you are viewing (1-4) and press MON. Table A. Keyboard Addresses NOTE: Switch positions 5 through 8 appear on the KBD200A and KBD300A. Set 5, 7, and 8 OFF. Switch 6 enables (ON) or disables (OFF) turbo pan. NOTE: You can also use older KBD200 and KBD300 models with the CM6700. Pelco Manual C523M-H (6/05) Keyboard 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Switch Settings 2 3 OFF OFF OFF OFF ON OFF ON OFF OFF ON OFF ON ON ON ON ON OFF OFF OFF OFF ON OFF ON OFF OFF ON OFF ON ON ON ON ON 4 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON 19 PROGRAMMING Programming allows you to assign titles for cameras, establish monitor group sequences, enable/disable alarms, establish access restrictions, set alarm options, set time and date, change password, and set auxiliary options. Refer to Figure 20. You program the CM6700 with the keyboard and a monitor. During programming, a menu appears on the monitor screen. Use the sequence and macro keys (KBD100), pan/tilt positioning keys (KBD200A), or the joystick (KBD300A) on your keyboard to navigate the menu. The F1 and F2 keys select (toggle) options and scroll through lists. Use the numerical keypad to enter numerical values. Programming the CM6700 SCU is described in Table B. Table B is arranged in the general order in which you should program your SCU, but also allows you to go into the programming mode at any time to change a particular item. If you do not wish to perform a step (for example, change password), just go to the next step. If you are familiar with programming the SCU, you can use Figure 20 by itself to quickly locate any program item. Permission is granted to copy Figure 20 if you wish to post it in a convenient location for quick reference. Table B. Programming the CM6700 Switching Control Unit Step 1 Function Enter Main Menu Action a. Press the PGM key. Result The Password screen appears. ENTER YOUR PASSWORD (Default is 2899100) LANGUAGE: ENGLISH Select English. b. Make sure the language selection is English. c. Use the number keypad to enter the password – default is 2899100 (Pelco’s toll-free phone number). Asterisks (*) appear on screen for each number you type. d. Press ACK. The Main Menu appears. MAIN MENU 1. CAMERAS 2. MONITORS 3. TIME/DATE 4. ALARMS 5. PORTS 6. AUXILIARIES 7. PASSWORD 8. ACCESS 9. EXIT e. Go to another step or press 9 to exit. (Continued on page 22) 20 Pelco Manual C523M-H (6/05) CAMERA XX CAMERA TITLE CAM O1 RX TYPE: 422P START RETURN PROCEDURE Enter Camera #. METHOD Keypad Enter Camera Title (1-20 characters). F1/F2 Select Receiver Type (Std. Coaxitron, Ext. Coaxitron, 422D, or 422P). F1/F2 or Pan L/R MONITOR XX SEQUENCE MENU ENTRY 1-8 ENTRY 9-16 CAM DWL PRE CAM DWL PRE 01 02 03 04 05 06 07 08 02 02 02 02 02 02 02 02 00 00 00 00 00 00 00 00 09 10 11 12 13 14 15 16 02 02 02 02 02 02 02 02 RETURN 00 00 00 00 00 00 00 00 PROCEDURE Enter Monitor #. Keypad Set Dwell time (1-99 sec) and Preset number for each camera in the 16-step sequence. Keypad PROCEDURE PRESS PROCEDURE Enter Monitor # (1-4). PGM MONITOR XX ALARM TYPE: AUTO ALARM DWELL: 05 DISPLAY: * 1. CAMERA SEQUENCE 2. ALARM ENABLE 3. POSITION DISPLAY RETURN ENTER YOUR PASSWORD (Default is 2899100) LANGUAGE: ENGLISH Select English. PRESS SET TIME/DATE DATE: 03-01-00 TIME: 11:27:00 PM DISPLAY AS: STYLE: DD-MM-YY TYPE: 12 HOUR SET CLOCK Select Alarm Type (Off, Auto, Manual). F1/F2 Set Alarm Dwell (0-99 sec). Keypad Turn display On/Off. F1/F2 1 2 3 4 5 6 METHOD Keypad Enter Time (Note Type). Keypad F1/F2 Select Style (MMM-DD-YY, DD-MM-YY, MM-DD-YY, DD-MMM-YY). Select Type (12 hour, 24 hour). F1/F2 or Pan L/R 7 8 9 10 11 12 ------- 13 14 15 16 17 18 ------- SET ALARM INPUT XX ALM ENABLE TYPE PRESET 1 -NO 00 NO 00 2 -NO 00 3 -NO 00 4 -NO 00 5 -NO 00 6 -NO 00 7 -NO 00 8 -RETURN 1. INPUT 1-16 2. INPUT 17 AND 18 ALARM INPUT XX MACRO X ENABLE: -TYPE: NO MON CAM1 CAM2 CAM3 CAM4 1 01 02 03 04 2 05 06 07 08 3 09 10 11 12 4 13 14 15 16 MACRO PRESET MENU RETURN RETURN 1. Use your keyboard to perform all programming functions. 3. On the KBD100 and KBD200A use the keys to move around the screen. On the KBD300A use the joystick. METHOD Keypad Turn each alarm on/off (*/--). F1/F2 PAN/TILT LEFT RIGHT UP DOWN PREV NEXT MACRO HOLD KBD100 Move text around on the screen to place it in the desired location. METHOD Pan/Tilt KBD200A Press ACK when done. ACK PROCEDURE METHOD Select 1-8 or 9-16. F1/F2 Turn Alarm on/off (*/--). F1/F2 Select alarm source Type (NO, NC). F1/F2 Enter Preset to go to when alarm occurs. Keypad PROCEDURE PG Pan right SET ALARM INPUT KBD300A 4. To move right on this chart, move to the menu item and pan right or press the key for the number of the item. 5. To move left on this chart, move to RETURN and pan right. 6. To return to camera view from the Main Menu, press PGM. To return to camera view from any other screen press PGM twice. METHOD Select 17 or 18. F1/F2 Turn alarm on/off (*/--). F1/F2 Select alarm source Type (NO, NC). F1/F2 Assign 4 inputs for each monitor to sequence. Keypad MACRO X PRESETS MON CAM1 CAM2 CAM3 CAM4 PRE PRE PRE PRE 1 00 00 00 00 2 00 00 00 00 3 00 00 00 00 00 00 00 00 PROCEDURE Assign Preset for each input in sequence. METHOD Keypad RETURN PROCEDURE PORTS 1. COM PORT 1 2. COM PORT 2 RETURN TO NORMAL DISPLAY ------- NOTES: 2. Flashing character shows your position in a field. Enter Monitor #. PROCEDURE PROCEDURE Enter Date (Note Style). Select Set Clock to accept changes. MAIN MENU 1. CAMERAS 2. MONITORS 3. TIME/DATE 4. ALARMS 5. PORTS 6. AUXILIARIES 7. PASSWORD 8. ACCESS 9. EXIT MONITOR XX ALARM ENABLE ALM SET ALM SET ALM SET DISPLAY SHOWING POSITION OF TEXT Press PGM to cancel changes. ACK METHOD Keypad METHOD COM 1 SET PORT PROTOCOL 422D Select Protocol (422D, 422P). F1/F2 Pan L/R BAUD RATE 2400 Select Baud (1200, 2400, 4800, 9600). F1/F2 Pan L/R RETURN RETURN PROCEDURE SET AUXILIARY MENU AUX SOURCE MODE F1 ALM KEY F2 KBD -F3 KBD LAT RETURN SET PASSWORD OLD PASSWORD ******* NEW PASSWORD ******* VERIFICATION ******* RETURN PROCEDURE METHOD For each F# select F1/F2 auxiliary activation Source (Alarms defined for Monitor 1 or Keyboard). Select auxiliary output Mode (Off, Momentary, Latching, or Keyed). F1/F2 PROCEDURE Enter Old Password. METHOD Keypad Enter New Password. Keypad Enter New Password again. Keypad COM 2 SET PORT BAUD RATE 9600 PARITY Even STOP BITS 2 RETURN ACCESS RETURN METHOD Select Baud (1200, 2400, 4800, 9600). F1/F2 Pan L/R Set Parity (None, Even, Odd). F1/F2 Pan L/R Set Stop Bits (1, 2). F1/F2 Pan L/R CM6700 PROGRAMMING “QUICK REFERENCE” CHART KBD TO MONITOR ACCESS KBD MONITOR PRESET 1 2 3 4 ENABLE 1 2 3 4 5 6 7 8 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y RETURN 1. KEYBOARD TO MONITOR 2. MON TO CAMERA 1-10 3. MON TO CAMERA 11-16 METHOD MON TO CAMERA ACCESS MON CAMERA 12 3 4 5 6 7 8 9 10 1 YYYYYYYYYY 2 YYYYYYYYYY 3 YYYYYYYYYY 4 YYYYYYYYYY PROCEDURE Enable/disable each keyboard's ability to control the monitors (Y/N). METHOD F1/F2 Enable/disable each keyboard's ability to program a preset (Y/N). F1/F2 PROCEDURE METHOD F1/F2 Enable/disable each monitor's ability to display the image from each camera (Y/N). RETURN Figure 21. Quick Reference Chart Pelco Manual C523M-H (6/05) 21 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 2 Function Change Password NOTE: If you change the password and then forget the new one, you will have to reset the system to the factory defaults. All system programming will be lost. Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 7. The Set Password screen appears. The first asterisk (*) in the OLD PASSWORD field flashes. c. Type the existing password and press ACK. The first asterisk (*) in the NEW PASSWORD field flashes. If you make a mistake, you are prompted to try again. d. Type the new password and press ACK. The first asterisk (*) in the VERIFICATION field flashes. e. Type the new password again and press ACK. The screen says “NEW PASSWORD ACCEPTED.” If you make a mistake, you will be notified that the new password does not match the verification password. After the new password is accepted, the Main Menu appears. See the Troubleshooting section for the system reset procedure. f. Go to another step or press 9 to exit. PROCEDURE SET PASSWORD OLD PASSWORD ******* NEW PASSWORD ******* VERIFICATION ******* METHOD Enter Old Password. Keypad Enter New Password. Keypad Enter New Password again. Keypad RETURN 22 Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 3 Function Program Cameras Assign Camera Titles: Up to 20 alpha or numeric characters can be assigned to help identify on-screen video. This will appear with camera number, time and date on the monitor. Select Receiver Protocol: Type of receiver communication you will use to control a camera’s pan and tilt and lens (if applicable). Choose from Standard Coaxitron, Extended Coaxitron, Pelco D protocol or Pelco P protocol. NOTE: P and D protocols cannot be mixed in the same system. Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 1. The Camera NN screen appears. NN is the camera number. The camera number flashes. c. Enter the desired camera number (01-16) or pan left/right to show the desired camera number. The selected number appears on screen. d. Move down to highlight the CAMERA TITLE (CAM NN) field (the line below CAMERA TITLE). The first position in the CAMERA TITLE field flashes. e. Use the F1 and F2 keys to scroll through the available characters. There are 26 upper case letters, 26 lower case letters and the numbers 0-9. The first position shows the character you are on. f. When you find the character you want for the first position, pan right to the next position. The second position in the CAMERA TITLE field flashes. g. Use F1 and F2 to find the second character. The second position shows the character. h. Pan right. The third position in the CAMERA TITLE field flashes. i. Continue selecting characters until the title field is completed (up to 20 characters). The CAMERA TITLE field shows the entire title. j. To change any position’s entry, pan left until the character flashes and use F1 and F2 to change it. The new character flashes. k. When finished, move down to the RX TYPE field. The current protocol setting for the selected camera flashes. l. Use F1 and F2 to find the desired protocol. The selected protocol appears. m. To program another camera, go to step n. When you have finished programming cameras, go to step o. n. Move up to the CAMERA NN field and go back to step c to program another camera. When you have finished programming cameras, go to step o. o. Move down to RETURN and pan right to go back to the Main Menu. The Main Menu appears. p. Go to another step or press 9 to exit. PROCEDURE CAMERA XX CAMERA TITLE CAM O1 RX TYPE: 422P RETURN Pelco Manual C523M-H (6/05) Enter Camera #. Enter Camera Title (1-20 characters). Select Receiver Type (Std. Coaxitron, Ext. Coaxitron, 422D, or 422P). METHOD Keypad F1/F2 F1/F2 or Pan L/R 23 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 4 Function Program Monitors Alarm Type: Manual – must press ACK to reset. Auto – alarm resets 10 seconds after alarm normalizes. Off – no alarms shown. Alarm Dwell: 1 to 99 seconds – time between display of multiple alarm screens. Character Display: On or off. Program Camera Sequences: Each monitor can have one 16-step sequence. Set dwell time and preset number for each camera. Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 2. The Monitor NN screen appears. NN is the monitor number. The monitor number flashes. c. Enter the desired monitor number (01-04) or pan left/ right to show the desired monitor number. The selected number appears on screen. d. Move down to highlight the ALARM TYPE: field. The current alarm type for the selected monitor appears on screen. e. Use the F1 and F2 keys to find the desired alarm type. The selected alarm type appears. f. Move down to highlight the ALARM DWELL field. The current alarm dwell for the selected monitor appears on screen. g. Use the keypad to enter the desired dwell time (1 to 99 seconds). The entered dwell time appears. h. Move down to highlight the DISPLAY field. The current status of character display appears. i. Use F1 and F2 to toggle the character display on or off. Asterisk (*) = on, dashes (--) = off. j. Move down to the 1. CAMERA SEQUENCE field. The 1. In the 1. CAMERA SEQUENCE field flashes. k. Pan right. The Monitor NN Sequence Menu appears. l. Use the position keys or joystick to move around the menu. Set Camera Number (1-16), Dwell Time (1-99 sec.) and Preset number for each camera in the sequence. Enter zeroes to skip a camera. The entered values appear. m. Move down to RETURN. The R in RETURN flashes. n. Pan right. The Monitor NN screen appears. (Continued on next page) MONITOR XX SEQUENCE MENU ENTRY 1-8 ENTRY 9-16 CAM DWL PRE CAM DWL PRE 01 02 03 04 05 06 07 08 02 02 02 02 02 02 02 02 00 00 00 00 00 00 00 00 09 10 11 12 13 14 15 16 02 02 02 02 02 02 02 02 00 00 00 00 00 00 00 00 PROCEDURE Enter Monitor #. METHOD Keypad Set Dwell time (1-99 sec) Keypad and Preset number for each camera in the 16-step sequence. RETURN PROCEDURE PROCEDURE METHOD Enter Monitor # (1-4). Keypad Select Alarm Type F1/F2 (Off, Auto, Manual). MONITOR XX ALARM TYPE: AUTO ALARM DWELL: 05 DISPLAY: * 1. CAMERA SEQUENCE 2. ALARM ENABLE 3. POSITION DISPLAY RETURN 24 Set Alarm Dwell (0-99 sec). Keypad Turn display On/Off. F1/F2 MONITOR XX ALARM ENABLE ALM SET ALM SET ALM SET 1 2 3 4 5 6 ------- 7 8 9 10 11 12 ------- 13 14 15 16 17 18 ------- Keypad Turn each alarm on/off (*/--). F1/F2 PROCEDURE DISPLAY SHOWING POSITION OF TEXT METHOD Enter Monitor #. Move text around on the screen to place it in the desired location. METHOD Pan/Tilt Press ACK when done. ACK Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 4 (Continued) Function Action o. Move down to the 2. ALARM ENABLE field. Result The 2. in the 2. ALARM ENABLE field flashes. p. Pan right. The Monitor NN Alarm Enable screen appears. q. Turn each alarm on or off. Asterisk (*) = on, dashes (--) = off. r. Move down to RETURN. The R in RETURN flashes. s. Pan right. The Monitor NN screen appears. t. Move down to the 3. POSITION DISPLAY field. The 3. in the 3. POSITION DISPLAY field flashes. u. Pan right. The real-time camera display appears with superimposed text. v. Use the position keys or joystick to move the text to the desired position on the screen. The text moves one line or character position at a time. w. Press the ACK button. The Monitor NN screen appears. x. To program another monitor, go to step c. When you have finished programming monitors, go to step y. y. Move down to RETURN and pan right to go back to the Main Menu. The Main Menu appears. z. Go to another step or press 9 to exit. Pelco Manual C523M-H (6/05) 25 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 5 Function Program Time and Date Time and date is kept current in battery-backed RAM. Corrections can be made when necessary. The time and date displayed is the time in memory when the TIME/DATE field is selected. The new time will be set when you select the SET CLOCK field and pan right. Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 3. The Set Time/Date screen appears. The MONTH field flashes. Take note of the contents of the STYLE and TYPE fields for the following procedure. The Style must be MMM-DD-YY and the Type must be 12 hour. If they are not, move down to the field and use the F1 and F2 keys to change them, then move back up to the first field. c. Use F1 and F2 to find the desired month. The selected month appears. d. Pan right. The DAY field flashes. e. Use the keypad to select the desired day. The selected day appears. f. Pan right. The YEAR field flashes. g. Use the keypad to select the desired year. The selected year appears. NOTE: To abort time and date programming without changing the settings already in memory, press PGM. h. To change any position’s entry, pan left until the character flashes and use the keypad or F1 and F2 to change it. i. Pan right and move down to TIME field. The HOUR field flashes. j. Use the keypad to select the desired hour. The selected hour appears. k. Pan right. The MINUTE field flashes. l. Use the keypad to select the desired minute. The selected minute appears. m. Pan right. The SECOND field flashes. n. Use the keypad to select the desired second. The selected second appears. o. Pan right. The AM/PM designator field flashes. p. Use F1 and F2 to select the correct designator. The selected designator flashes. q. Move down to the STYLE field. The STYLE field flashes. (Continued on next page) PROCEDURE Enter Date (Note Style). SET TIME/DATE DATE: 03-01-00 TIME: 11:27:00 PM DISPLAY AS: STYLE: DD-MM-YY TYPE: 12 HOUR SET CLOCK Keypad Enter Time (Note Type). Keypad F1/F2 Select Style (MMM-DD-YY, DD-MM-YY, MM-DD-YY, DD-MMM-YY). Select Type (12 hour, 24 hour). Press PGM to cancel changes. Select Set Clock to accept changes. 26 METHOD F1/F2 or Pan L/R PG Pan right Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 5 (Continued) Function Action Result r. Use F1 and F2 to select the desired style (DD-MM-YY, The selected style flashes. MM-DD-YY, DD-MMM-YY and MMM-DD-YY). s. Move down to the TYPE field. The TYPE field flashes. t. Use F1 and F2 to select the desired type (12 HOUR or 24 HOUR). The selected type flashes. u. Move down to the SET CLOCK field. The SET CLOCK field flashes. v. Check all your entries. If any fields are incorrect, move to them, enter the corrections, and move back to the SET CLOCK field. The SET CLOCK field flashes. w. When you are ready to set the time, mark time and pan right when the new time in the TIME field arrives. The clock begins running from the new time. The Main Menu appears. x. Go to another step or press 9 to exit. Pelco Manual C523M-H (6/05) 27 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 6 Function Program Alarms 1-16 Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 4. The Set Alarm Input screen appears. Alarms are programmed in two groups. The Group 1 (INPUT 1-16) number flashes. c. Pan right. The Set Alarm Input 1-8 screen appears. 1-8 flashes. d. Move down to the ALM ENABLE 1 field. The entry in the ENABLE field flashes. e. Use the F1 and F2 keys to toggle the Alarm Enable field (* = ON, -- = OFF). If you selected OFF go to step k; otherwise, go to the next step. The selected value flashes. f. Pan right. The entry in the TYPE field flashes. g. Use the F1 and F2 keys to toggle the Alarm TYPE field (NO = normally open contacts, NC = normally closed contacts). The selected value flashes. h. Pan right. The entry in the PRESET field flashes. i. Use the keypad to select the desired preset (that the camera will assume when an alarm occurs) for this alarm number. The selected value flashes. j. Pan right. The Alarm 1 ENABLE field flashes. k. To program another alarm, go to step l. When you have finished programming the alarms in this group, go to step m. l. Move down to the next ALM ENABLE field. Repeat steps e through k for the next alarm. The entry in the ENABLE field flashes. m. To program group 2 (INPUT 9-16), go to step n. When you have finished programming the alarms in group 2, go to step r. n. Move up to the Set Alarm Input 1-8 screen. The Set Alarm Input 1-8 screen appears. 1-8 flashes. (Continued on next page) PROCEDURE SET ALARM INPUT 1. INPUT 1-16 2. INPUT 17 AND 18 SET ALARM INPUT XX ALM ENABLE TYPE PRESET 1 -NO 00 2 -NO 00 3 -NO 00 4 -NO 00 5 -NO 00 6 -NO 00 7 -NO 00 8 -NO 00 RETURN METHOD Select 1-8 or 9-16. F1/F2 Turn Alarm on/off (*/--). F1/F2 Select alarm source Type (NO, NC). F1/F2 Enter Preset to go to when alarm occurs. Keypad RETURN 28 Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 6 (Continued) Function Action o. Pan right. p. Move down to the ALM ENABLE 9 field. Result The Set Alarm Input 9-16 screen appears. 9-16 flashes. The screen changes to show alarms 9-16. The entry in the ENABLE field flashes. q. Repeat steps e through l for alarms 9 through 16. Then go to step r. r. Move down to RETURN. The R in RETURN flashes. s. Pan right. The Set Alarm Input screen appears. t. To program the macros (inputs 17 and 18), go to step 7c. u. Move down to RETURN and pan right to go back to the Main Menu. The Main Menu appears. v. Go to another step or press 9 to exit. Pelco Manual C523M-H (6/05) 29 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 7 Function Program Alarms 17 & 18 Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 4. The Set Alarm Input screen appears. Alarms are programmed in two groups. The Group 1 (INPUT 116) number flashes. c. Press 2. The Set Alarm Input 17 screen appears. The number 17 flashes. d. Move down to the ENABLE field. The entry in the ENABLE field flashes. e. Use the F1 and F2 keys to toggle the Alarm Enable field (* = ON, -- = OFF). If you selected OFF go to step q. Otherwise go to the next step. The selected value flashes. f. Pan right. The entry in the TYPE field flashes. g. Use the F1 and F2 keys to toggle the Alarm TYPE field (NO = normally open contacts, NC = normally closed contacts). The selected value flashes. h. Move down to the MON1/CAM1 field in the Macro matrix. The entry in the MON1/CAM1 field flashes. i. The entry indicates which camera will be displayed first on monitor number 1 when the Macro alarm is activated. Use the keypad to enter the desired camera number. The entered value flashes. The selected value flashes. j. Use the pan and tilt to move through the matrix and assign the cameras to the sequence for each monitor. If a monitor is not to be included in the sequence, enter all zeros. Each selected value flashes. k. When you have completed all entries, move down to MACRO PRESET MENU. The M in MACRO PRESET MENU flashes. l. Pan right. The Macro 1 (or 2) Presets screen appears. The entry in the MON1/CAM1 field flashes. m. The entry indicates which preset will be assumed by the MON1/CAM1 camera when the Macro alarm is activated. Use the keypad to enter the desired preset number. The entered value flashes. (Continued on next page) PROCEDURE SET ALARM INPUT 1. INPUT 1-16 2. INPUT 17 AND 18 RETURN ALARM INPUT XX MACRO X ENABLE: -TYPE: NO MON CAM1 CAM2 CAM3 CAM4 1 01 02 03 04 2 05 06 07 08 3 09 10 11 12 4 13 14 15 16 MACRO PRESET MENU RETURN METHOD Select 17 or 18. F1/F2 Turn alarm on/off (*/--). F1/F2 Select alarm source Type (NO, NC). F1/F2 Assign 4 inputs for each Keypad monitor to sequence. MACRO X PRESETS MON CAM1 CAM2 CAM3 CAM4 PRE PRE PRE PRE 1 00 00 00 00 2 00 00 00 00 3 00 00 00 00 00 00 00 00 PROCEDURE METHOD Assign Preset for each input in sequence. Keypad RETURN 30 Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 7 (Continued) Function Action n. Use the sequence and macro keys (KBD100) or pan and tilt to move through the matrix and use the keypad to assign the presets for each MON/CAM entry. Result Each entered value flashes. o. When you have completed all entries, move down to RETURN. The R in RETURN flashes. p. Pan right. The Alarm Input 17 (or 18) Macro 1 (or 2) screen appears. The number 17 (or 18) flashes. q. To program Alarm Input 18, Macro 2, go to step r. To exit go to step t. r. Pan right. The Alarm Input 18 Macro 2 screen appears. The number 18 flashes. s. Repeat steps d through q for Alarm Input 18, Macro 2. t. Move down to the RETURN field at the bottom of the screen. The R in RETURN flashes. u. Pan right. The Set Alarm Input screen appears. v. Move down to the RETURN field at the bottom of the screen. The R in RETURN flashes. w. Pan right. The Main Menu appears. x. Go to another step or press 9 to exit. Pelco Manual C523M-H (6/05) 31 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 8 Function Program Com Ports Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 5. The Ports screen appears. Port number 1 flashes. c. To configure port 1, go to step d. To skip port 1 and configure port 2, go to step j. d. Pan right. The COM 1 Set Port screen appears. The entry in the PROTOCOL field flashes. e. Use the F1 and F2 keys to toggle the protocol field. The selected value flashes. f. Move down to the BAUD RATE field. The entry in the BAUD RATE field flashes. g. Use F1 and F2 to select the desired baud rate. The selected value flashes. h. Move down to the RETURN field. The R in RETURN flashes. i. Pan right. The Ports screen appears. j. Move down to the COM 2 PORT field. Port number 2 flashes. k. Pan right. The COM 2 Set Port screen appears. The entry in the BAUD RATE field flashes. l. Use F1 and F2 to toggle baud rate field. The selected value flashes. m. Move down to the PARITY field. The entry in the PARITY field flashes. n. Use F1 and F2 to select the parity. The selected value flashes. o. Move down to the STOP BITS field. The entry in the STOP BITS field flashes. p. Use F1 and F2 to select the stop bits. The selected value flashes. q. Move down to the RETURN field. The R in RETURN flashes. r. Pan right. The Ports screen appears. s. Move down to the RETURN field. The R in RETURN flashes. t. Pan right. The Main Menu appears. u. Go to another step or press 9 to exit. PORTS 1. COM PORT 1 2. COM PORT 2 PROCEDURE METHOD COM 1 SET PORT PROTOCOL 422D Select Protocol (422D, 422P). F1/F2 Pan L/R BAUD RATE 2400 Select Baud (1200, 2400, 4800, 9600). F1/F2 Pan L/R RETURN RETURN PROCEDURE COM 2 SET PORT BAUD RATE 9600 PARITY Even STOP BITS 2 RETURN 32 METHOD Select Baud (1200, 2400, 4800, 9600). F1/F2 Pan L/R Set Parity (None, Even, Odd). F1/F2 Pan L/R Set Stop Bits (1, 2). F1/F2 Pan L/R Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 9 Function Program Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 6. The Set Auxiliary Menu screen appears. The entry in the AUX F1 SOURCE field flashes. c. Use the F1 and F2 keys to select the source. The selected value flashes. d. Pan right. The entry in the MODE field flashes. e. Use F1 and F2 to select the mode. The selected value flashes. Auxiliary Outputs AUX F1, F2, and F3 can be operated by an alarm* (ALM) or from the keyboard (KBD). Mode can be off (--), on or off latching (LAT), momentary for 300 microseconds (MOM), or momentary for the time the key is held down (KEY). *Alarms as defined for Monitor 1. f. Pan left and move down to the AUX F2 SOURCE field. The entry in the AUX F2 SOURCE field flashes. g. Use F1 and F2 to select the source. The selected value flashes. h. Pan right. The entry in the MODE field flashes. i. Use F1 and F2 to select the mode. The selected value flashes. j. Pan left and move down to the AUX F3 SOURCE field. The entry in the AUX F3 SOURCE field flashes. k. Use F1 and F2 to select the source. The selected value flashes. l. Pan right. The entry in the MODE field flashes. m. Use F1 and F2 to select the mode. The selected value flashes. n. Move down to the RETURN field. The R in the RETURN field flashes. o. Pan right. The Main Menu appears. p. Go to another step or press 9 to exit. PROCEDURE SET AUXILIARY MENU AUX SOURCE MODE F1 ALM KEY F2 KBD -F3 KBD LAT RETURN Pelco Manual C523M-H (6/05) METHOD For each F# select auxiliary activation Source (Alarm or Keyboard). F1/F2 Select auxiliary output Mode (Off, Momentary, Latching, or Keyed). F1/F2 33 Table B. Programming the CM6700 Switching Control Unit (Continued) Step 10 Function Program Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 8. The Access screen appears. Access is programmed in three groups. The group 1 (Keyboard to Monitor) number flashes. c. Pan right. The Keyboard to Monitor Access matrix screen appears. The entry for KBD 1/MONITOR 1 flashes. d. Use the F1 and F2 keys to toggle the keyboard 1/ monitor 1 access entry. The selected value flashes. e. Use the sequence and macro keys (KBD100) or pan and tilt to move through the matrix. Use F1 and F2 to assign the desired value for each keyboard/ monitor combination and preset enable. The selected values flash. f. When you have completed all entries, move down to RETURN. The R in the RETURN field flashes. g. Pan right. The Access screen appears. Keyboard Access Access determines which keyboards have access to which monitors and if presets can be programmed. h. To continue with Access programming, go to step c. Otherwise continue with the next step. i. Move down to the RETURN field. The R in RETURN flashes. j. Pan right. The Main Menu appears. k. Go to another step or press 9 to exit. PROCEDURE ACCESS 1. KEYBOARD TO MONITOR 2. MON TO CAMERA 1-10 3. MON TO CAMERA 11-16 RETURN KBD TO MONITOR ACCESS KBD MONITOR PRESET 1 2 3 4 ENABLE 1 2 3 4 5 6 7 8 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y RETURN 34 Y Y Y Y Y Y Y Y METHOD Enable/disable each keyboard's ability to control the monitors (Y/N). F1/F2 Enable/disable each keyboard's ability to program a preset (Y/N). F1/F2 Pelco Manual C523M-H (6/05) Table B. Programming the CM6700 Switching Control Unit (Continued) Step 11 Function Program Camera Access Access determines which camera images are shown on which monitors. Action a. Enter the Main Menu. Result The Main Menu appears. b. Press 8. The Access screen appears. Access is programmed in three groups. The group 1 (Keyboard to Monitor) number flashes. c. Move down to the group 2 (MON TO CAMERA 1-10) field. The group 2 number flashes. d. Pan right. The Monitor to Camera Access matrix screen appears. The entry for MON 1/CAMERA 1 flashes. e. Use the F1 and F2 keys to toggle the monitor 1/ camera 1 access entry. The selected value flashes. f. Use the sequence and macro keys (KBD100) or pan and tilt to move through the matrix. Use F1 and F2 to assign the desired value for each keyboard/ monitor combination. The selected values flash. g. When you have completed all entries, move down to RETURN. The R in the RETURN field flashes. h. Pan right. The Access screen appears. The group 1 (Keyboard to Monitor) number flashes. i. To program group 3 go to step j. Otherwise go to step l. The group 3 number flashes. j. Move down to the group 3 (MON TO CAMERA 1116) field. k. Repeat steps d through i for group 3. l. Move down to the RETURN field. The R in RETURN flashes. m. Pan right. The Main Menu appears. n. Go to another step or press 9 to exit. ACCESS 1. KEYBOARD TO MONITOR 2. MON TO CAMERA 1-10 3. MON TO CAMERA 11-16 RETURN MON TO CAMERA ACCESS MON CAMERA 12 3 4 5 6 7 8 9 10 1 YYYYYYYYYY 2 YYYYYYYYYY 3 YYYYYYYYYY 4 YYYYYYYYYY PROCEDURE METHOD F1/F2 Enable/disable each monitor's ability to display the image from each camera (Y/N). RETURN Step 12 Function Program Presets, Patterns, and Zones Action Refer to your keyboard manual. Result Programming is completed. Pelco Manual C523M-H (6/05) 35 OPERATION The CM6700 can be operated with a KBD100, KBD200A, or KBD300A keyboard. It can also be operated from a PC with ASCII operating commands. Refer to your keyboard manual for keyboard operating instructions. ASCII OPERATING COMMANDS NOTE: If you are using a PC to send ASCII commands via COM 2, refer to the Troubleshooting section. ASCII protocol uses the ASCII character set to transmit and receive commands between a personal computer (PC) and the CM6700. The commands are readable but are not English. They control the pan and tilt mechanisms (fixed and variable speed), camera functions, auxiliary relays, and alarms. The ASCII protocol communicates in a standard asynchronous, byte-oriented protocol that includes: 1 start bit, 8 data bits, 1 parity bit (odd parity), and 1 stop bit. The communication rate is 9600 baud. A lowercase “a” ends each command. The ASCII translator acknowledges accepted commands with “AKa” and rejected commands with “NA”, the command that was rejected, and a lowercase “a”. If it does not recognize the command, it sends “NAa”. If the command requires a numeric value, enter the number first. Table C gives examples of ASCII commands. Table D lists all of the commands. Table C. Examples of ASCII Commands Functional Procedure Select a pan and tilt device labeled “CAMERA # 16” and switch it to monitor # 3. Manipulate the pan and tilt device. Switch a camera. Call a preset. Pan and tilt. 36 Commands 3Ma 16#a 1Ma3#a 5Ma2#a3\a 47Ra33Da sa 1Ma3#a 5Ma2#a3\a 47Ra33Da Result Switch camera # 16 to currently selected monitor 3. Switch camera 3 to monitor 1. Go to camera 2, preset 3, on monitor 5. Pan right at speed 47, tilt down at speed 33. Stop tilt down only. Switch camera 3 to monitor 1. Go to camera 2, preset 3, on monitor 5. Pan right at speed 47, tilt down at speed 33. Pelco Manual C523M-H (6/05) Table D. ASCII Commands Number ranges are enclosed in brackets–do not enter the brackets. When you control a fixed speed pan and tilt, omit the speed information. Desired Action Command Select monitor [1-9999]Ma Calls a monitor to use for camera operation. Select camera Next camera Previous camera [1-9999]#a +a –a Selects a camera to display on the current operating monitor. The NEXT Start a sequence [1-99]qa Starts the selected sequence going forward (incrementing camera forward Result key (+) and PREV key (-) commands switch to the next numbered camera in the system. numbers) by pressing and holding the NEXT key for two seconds. Start a sequence backward [1-99]ba Hold a sequence ea Starts the selected sequence going backward (decrementing camera numbers) by pressing and holding the PREV key for two seconds. Places the running sequence on hold, freezing the currently selected camera on the monitor. It lets you control the camera or switch. The sequence is still “armed” on the monitor, but inactive. Pan left Pan right Stop pan left Stop pan right [1-64]La [1-64]Ra sa or ~La sa or ~Ra Moves the currently selected pan and tilt device left or right at the speed Tilt up Tilt down Stop tilt up Stop tilt down [1-63]Ua [1-63]Da sa or ~Ua sa or ~Da Moves the currently selected pan and tilt device up or down at the speed Zoom telephoto Zoom wide Stop zoom telephoto Stop zoom wide Ta Wa sa or ~Ta sa or ~Wa Makes the currently selected camera zoom in (close up view) or zoom Focus near Focus far Stop focus near Stop focus far Na Fa sa or ~Na sa or ~Fa Changes the good focus range nearer or farther on the currently Iris open Iris close Stop iris open Stop iris close Oa Ca sa or ~Oa sa or ~Ca Opens (brighter image) or closes (darker image) the iris on the currently Stop all PTZ motion sa Stops all image motion (stops pan, tilt, zoom, focus, and iris). Does not Record pattern Execute pattern End pattern [1-99]/a [1-99]pa [1-99]na On receivers that do patterns, these commands let you record your Go to preset position [1-99]\a Recalls a stored preset position. Set preset with a label la[string]!a [1-9999]^a Sets a preset location with an embedded label, where the ASCII string indicated. If you omit the speed, some devices move at their default speed and others move at their slowest possible speed. Speed information has no effect on fixed speed devices. indicated. If you omit the speed, some devices move at their default speed and others move at their slowest possible speed. Speed information has no effect on fixed speed devices. out (wide view). selected camera. selected camera. stop a pattern. motions and operations (for a limited time) and then have the system repeat them. must be UPPERCASE characters. The [string] is an alphanumeric label up to 20 ASCII characters long and [1-9999] is the associated preset number. NOTE: All transmitted characters must be ASCII. Auxiliary on Auxiliary off [1-9999]Aa [1-9999]Ba Auxiliaries are relay outputs that can be controlled through the protocol. 1-8 operate auxiliaries at the camera (receiver) and 9-11 operate F1-F3 auxiliaries at the CM6700. (Continued on next page) Pelco Manual C523M-H (6/05) 37 Table D. ASCII Commands (Continued) Desired Action Start macro Command [1-99]Sa Acknowledge alarm Send camera titles [1-9999]Ia Ya[string1/…/string16]!a Result Starts the pre-programmed system group camera sequence (the CM6700 supports only two macros–1 and 2). Acknowledges an existing alarm. Sends a series of camera titles (up to 16) to a matrix switching system. The first string always corresponds to camera #1, then each subsequent string (separated by a slash) corresponds to the next higher camera number (ending with camera #16). You can choose to send fewer than 16 camera titles; be sure to end with ]!a. Valid characters in the string are A-Z, a-z, space, and 0-9 in ASCII representation. Strings are limited to 20 characters. Send one camera title [camera number (1-16)] Ya[camera title]!a Sends one camera title to the matrix switching system. Valid characters in the string are A-Z, a-z, space, and 0-9 in ASCII representation. Strings are limited to 20 characters. Version va Returns the device’s version number. Set date and time ZaMM/DD/YY/HH:MM:SSa This mode of operation command sets the date and time. Since the date and time string might be confused with other commands, Za comes first. This puts the receiving device into a mode that can accept the specialized string. NOTE: All transmitted characters must be ASCII. 38 Pelco Manual C523M-H (6/05) TROUBLESHOOTING GAINING INITIAL CONTROL If you are having problems gaining control of your system for the first time: 1. 2. Confirm that everything is plugged in and has power. Confirm that multiple keyboards have different DIP switch addresses. See the Switch Settings section. 3. Confirm that keyboard interconnect cable is wired correctly. See installation step 9 – Connect Keyboards. 4. Be sure data cables have not been mixed up. See Figure 19. 5. Cycle (unplug and then plug in again) the data cable to the keyboard. 6. WAIT AT LEAST FIVE SECONDS. 7. Select a monitor. If you still cannot gain control of the system: 1. Confirm the wiring is correct and the user-supplied cable between wall jacks is appropriate for the application. 2. Confirm that when the keyboard data cable is cycled, the keyboard LED flashes momentarily (indicating power). If you still cannot gain control of the system, call Pelco’s 24-hour technical support at 1-800-289-9100 or 1-559-292-1981. USING A PC TO SEND ASCII COMMANDS VIA COM 2 The CM6700 will ignore ASCII commands issued to the COM 2 port from an external device (such as a PC) if (1) the commands are issued manually from a PC, AND (2) a system keyboard is connected to the local keyboard port. The CM6700 will respond with the acknowledgement string (AK or NA), but it will not execute the commands. Under these conditions the CM6700 will execute the ASCII commands if they are issued as strings from a text file or programmed function key. The problem exists only if keying the characters in manually. Solution: Disconnect any system keyboard from the CM6700 if you are manually keying in ASCII commands from a PC, or 2) do not key ASCII characters in manually. Write command strings to text files and send the file. If using Terminal in Windows 3.1, program the function keys with complete command strings. PERFORMING A SOFTWARE RESET CAUTION: Resetting the software restores the system to default settings. All program- Press the Software Reset button on the front panel (refer to Figure 21). The button is recessed to prevent accidental operation. Use a small screwdriver, pencil tip, or similar probe to operate the switch. Hold the switch in for about five seconds, and then release. The switcher will go through a software clear cycle and reset back to defaults. Re-initialize keyboards by entering the monitor number and then pressing the MON key. ming is lost. RESET BUTTON ACCESS HOLE CM 6700 CM6700-MXB Matrix Switcher/Controller Made in USA Figure 21. Software Reset Button Location Pelco Manual C523M-H (6/05) 39 Table E. Solutions To Common Problems Problem CM6700 does not have power. Remedy Make sure the power cord is plugged in. You can see some cameras and not others from your location. Confirm that the camera is properly connected and has power. Check the fuse. Refer to Figure 6 for the fuse location. The keyboard and monitor may have been denied access to the cameras. The CM6700 does not respond to keyboard commands. Confirm that the monitor the keyboard is addressing is the same as the monitor in front of you. Pressing the PGM key displays a P on the keyboard LED but the Password menu does not appear on the menu. Confirm that the keyboard transformer is plugged in and all electrical connections are in order. Confirm that the monitor the keyboard is addressing is the same as the monitor in front of you. Upon initial system startup, the alphanumeric monitor display is in the middle of the screen or is not seen. Jumper JP17 on the motherboard is in the wrong position. Remove the cover and change JP17 to the opposite position. Instructions for switching video termination jumpers in the Set Options section are a similar process. Keyboards do not function after installation and initial power-up. Confirm that all wiring is correct and that keyboards have power and are connected. Confirm that all keyboards are addressed differently. Previous system control has been lost. First, try initializing the keyboard by entering the monitor number followed by pressing the MON key. If this does not restore control… Second, try unplugging the data cable from the rear of the keyboard and then plugging it back in. Then re-initialize the keyboard. If this does not restore control… Third, power down the CM6700, power back up, and then re-initialize keyboards. If this does not restore control… Fourth, perform a software reset (refer to Performing a Software Reset in this section). If this does not restore control, call Pelco at 1-800-289-9100. Cannot gain keyboard and ASCII port PTZ control after another user has stopped controlling. You must wait at least five seconds after a separate user has stopped before you can gain control. The unit malfunctions and you cannot restore it to satisfactory operation. Perform a software reset (refer to Performing a Software Reset in this section). The keyboard transformer must be replaced. If a 12 VAC transformer is unavailable, you can use a 12 VDC transformer. Polarity is unimportant when wiring the transformer to the wall jack. Table F. Switcher/Controller and Keyboard RJ-45 Pin Functions Switcher/Controller Pin Function 1 RX+ 2 RX3 12 VAC 4 12 VAC 5 Ground 6 NC 7 TX8 TX+ Keyboards Pin Function 1 TX+ 2 TX3 12 VAC/DC 4 NON-POLAR 5 Ground 6 NC 7 RX8 RX+ NC = No connection 40 Pelco Manual C523M-H (6/05) SPECIFICATIONS SWITCHING Programmable Switching Duration: Programmable Number of Steps per Sequence: Maximum Number of Sequences: User-defined between 1 and 99 seconds 16 4 VIDEO INPUTS Number of inputs: Type: Level: Connector Type: 16 75-ohm, unbalanced, terminating or looping; jumper-selectable 1 Vp-p Panel-mount BNC VIDEO OUTPUTS Number: Type: Level: Video Fail Detection Type: Action: Connector Type: 4 (maximum) 75-ohm, unbalanced 1 Vp-p Vertical sync detector Switch to back-up sync generator Panel-mount BNC VIDEO SPECIFICATIONS Bandwidth: Frequency Response: Gain: Differential Gain: Differential Phase: Tilt: Signal-to-Noise: DC Output: Cross Talk: 17 MHz Flat to 8 MHz, ±1.0 dB to 15 MHz Unity (±1 dB) 2% typical 0.2° typical 0.5% typical -55 dB (peak-to-peak vs. RMS noise) Zero volts -50 dB typical at 3.58 MHz CHARACTER GENERATOR Display: Program Menus: White with black border Raster background with white characters KEYBOARD INTERFACE Protocol: Number of Ports: Number of Independent Keyboards: Data Rate: Connector Type: Cable Type (supplied): Keyboard 1 8 9600 baud RJ-45, 8-pin modular (female) 6 feet (1.8 m), flat, unshielded (may be shielded) ALARM INTERFACE INPUTS Number of Inputs: Connector Type: Sensing: Pelco Manual C523M-H (6/05) 18 12-pin screw terminal Programmable, N.O./N.C. 41 AUXILIARY OUTPUTS Number of Outputs: Connector Type: Contact Configuration F1: F2 and F3: 3 12-pin screw terminal Form C, 0.5 A at 125 VAC maximum Open collector, 32 VDC at 25 mA maximum POWER SUPPLY Input Voltage: Power Consumption: Ambient Operating Temperature: Humidity: 120 VAC, 50/60 Hz or 230 VAC, 50 Hz 10 watts 20° to 120°F (-7° to 49°C) 10–90% noncondensing PHYSICAL SPECIFICATIONS Dimensions: 17.0 (W) x 10.5 (D) x 3.5 (H) inches (43.18 x 26.67 x 8.89 cm) Weight CM6700-MXB2: CM6700-MXB2-X: CM6700-MXB4: CM6700-MXB4-X: 9.39 lb (4.26 kg) 9.47 lb (4.30 kg) 10.15 lb (4.61 kg) 10.06 lb (4.56 kg) Rating: Meets NEMA Type 1 standard (Design and product specifications subject to change without notice.) 42 Pelco Manual C523M-H (6/05) INDEX A J Q Alarm dwell 24 Alarm enable 28 Alarm inputs 5, 14 Alarm type 24 ASCII 5, 9, 17, 36 ASCII operating commands 36 Assign camera titles 23 AUX F1 15, 33 AUX F2 15, 33 AUX F3 15, 33 Auxiliary outputs 5, 15, 33 Jumpers 8 Quick reference chart 21 K R KBD100 4 KBD200A 4 KBD300A 4 KBDKIT 4, 18 KBDKIT-X 4, 18 Keyboard addresses 19 Keyboards 5 Regulatory notices 3 Relay 5 Relay output 15 Remote keyboards 18 Returns 44 RS-232 9, 17 RS-422 9, 11, 17 RS-422/485 17 RS-485 cable distance 18 B L Baud rate 32 Local keyboard 18 Looping terminations 8 C M Character display 24 CM6700 installation 8 CM6700-MXB2 4, 13 CM6700-MXB2-X 4, 13 CM6700-MXB4 4, 13 CM6700-MXB4-X 4, 13 CM6700-VMC2 4, 13 CM6700-VMC2-X 4, 13 CM9760-RDU 4, 12 Coaxitron 5, 11 COM 2 17, 32 COM 2 port 17, 32 Connect alarms 14 Connect auxiliaries 15 Connect COM 2 port 17 Connect control lines 11 Connect keyboards 18 Connect monitors 13 Connect video sources 10 Macro preset 30 Main menu 20 Mount unit 9 Multiplexer 5 D D or P protocol 5, 11 Daisy-chaining 11 Description 5 DIP switches 9, 18 G Group sequences 5 Pelco Manual C523M-H (6/05) O Open collector 5, 15 Operation 36 P P protocol 5, 11 Password – default 20 Patterns 5 Personal computer 5, 17, 36 Presets 5 Program alarms 28, 30 Program auxiliary outputs 33 Program camera access 35 Program camera sequences 24 Program cameras 23 Program communication ports 32 Program keyboard access 34 Program monitors 24 Program time and date 26 Programming 20 Programming presets, patterns, and zones 35 S Safeguards 3 Select receiver protocol 23 Sequences 5 Set options 8 Set time 26 Specifications 41 Star configuration 12 T Troubleshooting 39 TTL 5, 15 W Wall block 18 Warnings 3 Warranty 44 43 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard). • Three years on Camclosure ® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty. • Two years on standard motorized or fixed focal length lenses. • Two years on Legacy ®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products. ® ® ™ • Two years on Spectra , Esprit , ExSite , and PS20 scanners, including when used in continuous motion applications. • Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades). • Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura ™ Series distributed network-based video products. • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months. • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes). Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise. The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned. Method of return shipment shall be the same or equal to the method by which the item was received by Pelco. RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below. If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to: Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699 If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to: Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933 This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment. REVISION HISTORY Manual # C523M C523M-A C523M-B C523M-C C523M-D Date 6/97 10/97 4/98 9/98 3/99 C523M-E 6/99 9/99 C523M-F C523M-G 10/00 11/01 C523M-H 4/03 8/04 6/05 Comments Original version. Revised to add KBD300 keyboard information, update drawings, and expand troubleshooting section. Revised keyboard installation instructions as a result of hardware changes to rear panel. Changed manual pagination. Revised Section 4.2.5. Corrected an error in Figure 6. Revised programming menus. Documented an option for programming patterns for Spectra® . Added Section 5.8, Programming Zones, and renumbered subsequent sections. Revised Figures 31 and 32. Revised and reformatted entire manual. Added ASCII command information and some keyboard material. Added a Spanish menus option to the Password screen. Revised the Set Alarm Input and Set Time/Date programming menus and the procedures for setting alarm inputs and the time and date. Revised and reformatted entire manual. Revised Table D to add additional ASCII stop commands for pan, tilt, zoom, focus, and iris functions. These additional commands, which begin with a tilde (~), also work with the CM9760. Removed KBD300V installation material. Added ASCII command to send one camera title. Added information in the Troubleshooting section that there is a five-second wait required when trying to gain ASCII PTZ port control after another user gives up control. Removed agency logos and certifications; updated Warranty and Return information. Corrected Figure 9, Connecting Video Sources. Pelco, the Pelco Logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 2005, Pelco. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res Page Mode : UseOutlines XMP Toolkit : 3.1-702 About : uuid:bd3d4172-bac0-11da-adaf-000a95a25184 Producer : Acrobat Distiller 5.00 for Macintosh Keywords : Control Site Equipment|Matrix Switchers|CM6700 Series Create Date : 2005:11:07 08:21:03-08:00 Modify Date : 2006:04:04 08:20:06-07:00 Metadata Date : 2006:04:04 08:20:06-07:00 Creator Tool : Adobe PageMaker 7.0 Document ID : uuid:1966357a-4fda-11da-96a0-000a95a25184 Instance ID : uuid:914292f9-abef-409c-9501-b9dbc0ca7bcd Format : application/pdf Creator : . Title : Pelco CM6700 Matrix Switcher-Controller_manual Description : Subject : Control Site Equipment|Matrix Switchers|CM6700 Series Has XFA : No Page Count : 44EXIF Metadata provided by EXIF.tools