I N S T A L L A T I O N

Spectra® IV Series
Spectra® IV SE Series

In-Ceiling Mount Back Box

C3417M-B (11/06)

Installation

1

2

4

5

3

2

C3417M-B (11/06)

1. Locate the center point of the mounting location and insert the compass tool. Draw a circle.
2. Cut the circle out of the ceiling.
3. Attach the conduit fitting, lock nut, and safety chain bracket. Install a safety chain/cable (not supplied) that will
support up to 16 pounds (7.3 kg).
4. Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull
wiring into the back box through the conduit fitting. Refer to Table A, Table B, and Table C for wiring distances.
5. Install the back box by compressing the spring clips and pushing the back box through the hole. Tighten the screws
until you hear a clicking noise.
Table B. 24 VAC/24VDC Wiring Distances

Table A. Video Coaxial Cable
Requirements
Cable Type*

Maximum Distance

RG59/U

750 ft (229 m)

RG6/U

1,000 ft (305 m)

RG11/U

1,500 ft (457 m)

*Cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid
coverage

The following are the recommended maximum distances for 24 VAC
and 24 VDC applications and are calculated with a 10 percent voltage
drop. (Ten percent is generally the maximum allowable voltage drop
for AC- or DC-powered devices.)
Wire Gauge

AC/DC
Total VA/
Total Watts

20 AWG
(0.5 mm2)

18 AWG
(1.0 mm2)

16 AWG
(1.5 mm2)

14 AWG
(2.5 mm2)

23 VA/
15 watts

123 ft
(38 m)

196 ft
(60 m)

311 ft
(95 m)

495 ft
(151 m)

73 VA/
65 watts

39 ft
(12 m)

62 ft
(19 m)

98 ft
(30 m)

156 ft
(48 m)

NOTE: Input power for the dome is 24 VAC or 24 VDC. Using 24 VAC input power, power consumption is 23 VA per dome
for indoor models and 73 VA for outdoor models. Using 24 VDC input power, power consumption is 0.7 A (15 watts) for
indoor models and 3 A (65 watts) for outdoor models.
Use a 24 VAC transformer with the following minimum VA:
40 VA per dome

For indoor models (without heater)

100 VA per dome

For outdoor models (with heater)

.

Table C. UTP Wiring Distances
Receiver

Maximum Distance

Active
(Video Only)

0-3,000 ft
(0-914.4 m)

Passive
(Video, Coaxitron, Pelco V-Sync)

0-750 ft
(0-228.6 m)

NOTE: As a minimum, UTP requires Cat5, 100-ohm twisted pair cable.

C3417M-B (11/06)

3

6

7
ALARMS

AUX1

1
2
3
4
5
6
7
GND
NO
COM
NC
AUX2
GND
VIDEO

PWR- GND PWR+ RX- RX+ TX- TX+ UTP+ UTP-

4

C3417M-B (11/06)

6. Suspended Ceiling Only: Install the ceiling tile with the back box. Attach a T-rail clip on each side of the ceiling
tile.
WARNING: An electrical short in the back box may occur if the metal BNC connector is not completely covered by
the protective boot.
7. Connect wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the
power. The green LED will light.
NOTES:

C3417M-B (11/06)

•

Aux 1: Maximum 2 A at low voltage (<40 V)
Aux 2: Maximum 30 mA at 32 VDC

•

If you are using both unshielded twisted pair (UTP) wiring and a translator board, install the UTP wiring before
installing the translator board.

•

If you are installing an environmental back box in a railway application, attach a ground wire from the circuit
board power connector to a structural ground using at least 18-gauge wire.

5

8

SWITCH 1 AND 2

10

A

9

6

C3417M-B (11/06)

8. Configure DIP switches SW1 and SW2 located on the top of the dome drive. For DIP switch settings, refer to the
labels located on the top of the dome drive or to the Switch Settings section.
NOTE: When connecting more than one Spectra® dome to a single controller, terminate the unit farthest from the
controller. To terminate the dome drive set the SW2-10 switch to the ON position.
9. Install the dome drive. Refer to Table D for a list of compatible dome drives and back boxes. Line up the blue and red
tabs with the blue and red arrows on the hinged door inside the back box. Push in on the tabs. Insert one side and
then the other side. Continue pushing on the ends of the tabs until both sides click into place.

Table D. Spectra Dome Drive and Back Box Compatibility
Dome Drive
®

Spectra II
Spectra III™
Spectra IV

Spectra II
•
•
•

Back Box
Spectra III

Spectra IV

•
•

•
•

10. Install the lower dome. Snap the clip on the end of the trim ring leash into the hole on the lip of the back box.
Snap the trim ring into the plastic snap washers on the mounting screws.
To use your dome, refer to the operation and programming manual.

C3417M-B (11/06)

7

Troubleshooting
If your dome does not power up properly after installation, use the following steps.
1. Check the fuse on the circuit board inside the back box for continuity. Replace the fuse if needed.
2. Check the wiring with a volt meter to ensure proper voltage is being received into the back box.
If your dome powers up correctly, but you do not have accurate control, use the following steps.
1. Check the signal with a volt meter or an oscilloscope.
NOTE: This step will not apply if you are using Coaxitron control.
2. Ensure that the switch settings on the dome drive are set correctly. Refer to the Switch Settings section.
3. If you are using a Pelco controller, ensure that the factory-installed 16-pin jumper has not been removed. If you are
using a third-party controller, a TXB Series translator board must be installed. The dome will not function without this
16-pin jumper or a translator board installed.

8

C3417M-B (11/06)

Switch Settings
WARNING: If you are using D-type or P-type control, your system may not operate if the baud rate and address
switches are not set correctly. The switches are set at the factory at the defaults for D-type control (2400 baud and
address 1).
Table E. Switch Settings for SW2
Special Systems
Switch Number
AD-32 Preset System

1

2

3

4

5

6

7

8

9

10

ON

CM9502 Setting

ON

Vicon

Not currently available; SW2-3 is reserved for future use.

Serial Port Settings
Switch Number

4

5

RS422

1

2

3

OFF

OFF

6

7

8

9

10

RS485, Four Wire

OFF

ON

RS485, Two Wire

ON

ON

4

5

6

7

8

9

10

2400 Baud (Default for D-type Control)

OFF

OFF

OFF

4800 Baud (Default for P-type Control)

ON

OFF

OFF

9600 Baud

OFF

ON

OFF

6

7

8

9

10

D or P Protocol Baud Rate
Switch Number

1

2

3

Video Cable Type
Switch Number

1

2

3

4

5

Coax Cable

OFF

UTP Cable

ON

Dome Termination
Switch Number

1

2

3

4

5

6

7

8

9

10

Terminated

ON

Not Terminated

OFF

C3417M-B (11/06)

9

Table F. Switch Settings for SW1, P-Type Control
NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF. For D-type control systems, refer to Table G.
SWITCH SETTING

SPECTRA
ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

1

OFF

OFF

OFF

OFF

2

ON

OFF

OFF

3

OFF

ON

4

ON

ON

5

OFF

OFF

ON

6

ON

OFF

ON

7

OFF

ON

ON

SWITCH SETTING

SW1-5

SPECTRA
ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

OFF

17

OFF

OFF

OFF

OFF

ON

OFF

OFF

18

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

19

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

20

ON

ON

OFF

OFF

ON

OFF

OFF

21

OFF

OFF

ON

OFF

ON

OFF

OFF

22

ON

OFF

ON

OFF

ON

OFF

OFF

23

OFF

ON

ON

OFF

ON
ON

8

ON

ON

ON

OFF

OFF

24

ON

ON

ON

OFF

9

OFF

OFF

OFF

ON

OFF

25

OFF

OFF

OFF

ON

ON

10

ON

OFF

OFF

ON

OFF

26

ON

OFF

OFF

ON

ON

11

OFF

ON

OFF

ON

OFF

27

OFF

ON

OFF

ON

ON

12

ON

ON

OFF

ON

OFF

28

ON

ON

OFF

ON

ON

13

OFF

OFF

ON

ON

OFF

29

OFF

OFF

ON

ON

ON
ON

14

ON

OFF

ON

ON

OFF

30

ON

OFF

ON

ON

15

OFF

ON

ON

ON

OFF

31

OFF

ON

ON

ON

ON

16

ON

ON

ON

ON

OFF

32

ON

ON

ON

ON

ON

Table G. Switch Settings for SW1, D-Type Control
NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF. For P-type control systems, refer to Table F.
SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

10

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

C3417M-B (11/06)

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

71

ON

ON

ON

OFF

OFF

OFF

ON

OFF

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

72

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

73

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

74

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

75

ON

ON

OFF

ON

OFF

OFF

ON

OFF

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

76

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

77

ON

OFF

ON

ON

OFF

OFF

ON

OFF

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

78

OFF

ON

ON

ON

OFF

OFF

ON

OFF

39

ON

ON

ON

OFF

OFF

ON

OFF

OFF

79

ON

ON

ON

ON

OFF

OFF

ON

OFF

40

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

80

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

41

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

81

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

42

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

82

OFF

ON

OFF

OFF

ON

OFF

ON

OFF
OFF

43

ON

ON

OFF

ON

OFF

ON

OFF

OFF

83

ON

ON

OFF

OFF

ON

OFF

ON

44

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

84

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

45

ON

OFF

ON

ON

OFF

ON

OFF

OFF

85

ON

OFF

ON

OFF

ON

OFF

ON

OFF
OFF

46

OFF

ON

ON

ON

OFF

ON

OFF

OFF

86

OFF

ON

ON

OFF

ON

OFF

ON

47

ON

ON

ON

ON

OFF

ON

OFF

OFF

87

ON

ON

ON

OFF

ON

OFF

ON

OFF

48

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

88

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

49

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

89

ON

OFF

OFF

ON

ON

OFF

ON

OFF

50

OFF

ON

OFF

OFF

ON

ON

OFF

OFF

90

OFF

ON

OFF

ON

ON

OFF

ON

OFF

51

ON

ON

OFF

OFF

ON

ON

OFF

OFF

91

ON

ON

OFF

ON

ON

OFF

ON

OFF

52

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

92

OFF

OFF

ON

ON

ON

OFF

ON

OFF

53

ON

OFF

ON

OFF

ON

ON

OFF

OFF

93

ON

OFF

ON

ON

ON

OFF

ON

OFF

54

OFF

ON

ON

OFF

ON

ON

OFF

OFF

94

OFF

ON

ON

ON

ON

OFF

ON

OFF

55

ON

ON

ON

OFF

ON

ON

OFF

OFF

95

ON

ON

ON

ON

ON

OFF

ON

OFF

56

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

96

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF

57

ON

OFF

OFF

ON

ON

ON

OFF

OFF

97

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

58

OFF

ON

OFF

ON

ON

ON

OFF

OFF

98

OFF

ON

OFF

OFF

OFF

ON

ON

OFF

59

ON

ON

OFF

ON

ON

ON

OFF

OFF

99

ON

ON

OFF

OFF

OFF

ON

ON

OFF

60

OFF

OFF

ON

ON

ON

ON

OFF

OFF

100

OFF

OFF

ON

OFF

OFF

ON

ON

OFF

61

ON

OFF

ON

ON

ON

ON

OFF

OFF

101

ON

OFF

ON

OFF

OFF

ON

ON

OFF

62

OFF

ON

ON

ON

ON

ON

OFF

OFF

102

OFF

ON

ON

OFF

OFF

ON

ON

OFF
OFF

63

ON

ON

ON

ON

ON

ON

OFF

OFF

103

ON

ON

ON

OFF

OFF

ON

ON

64

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

104

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

65

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

105

ON

OFF

OFF

ON

OFF

ON

ON

OFF

66

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

106

OFF

ON

OFF

ON

OFF

ON

ON

OFF

67

ON

ON

OFF

OFF

OFF

OFF

ON

OFF

107

ON

ON

OFF

ON

OFF

ON

ON

OFF

68

OFF

OFF

ON

OFF

OFF

OFF

ON

OFF

108

OFF

OFF

ON

ON

OFF

ON

ON

OFF

69

ON

OFF

ON

OFF

OFF

OFF

ON

OFF

109

ON

OFF

ON

ON

OFF

ON

ON

OFF

70

OFF

ON

ON

OFF

OFF

OFF

ON

OFF

110

OFF

ON

ON

ON

OFF

ON

ON

OFF

C3417M-B (11/06)

11

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

12

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

111

ON

ON

ON

ON

OFF

ON

ON

OFF

151

ON

ON

ON

OFF

ON

OFF

OFF

112

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

152

OFF

OFF

OFF

ON

ON

OFF

OFF

ON
ON

113

ON

OFF

OFF

OFF

ON

ON

ON

OFF

153

ON

OFF

OFF

ON

ON

OFF

OFF

ON

114

OFF

ON

OFF

OFF

ON

ON

ON

OFF

154

OFF

ON

OFF

ON

ON

OFF

OFF

ON

115

ON

ON

OFF

OFF

ON

ON

ON

OFF

155

ON

ON

OFF

ON

ON

OFF

OFF

ON
ON

116

OFF

OFF

ON

OFF

ON

ON

ON

OFF

156

OFF

OFF

ON

ON

ON

OFF

OFF

117

ON

OFF

ON

OFF

ON

ON

ON

OFF

157

ON

OFF

ON

ON

ON

OFF

OFF

ON

118

OFF

ON

ON

OFF

ON

ON

ON

OFF

158

OFF

ON

ON

ON

ON

OFF

OFF

ON

119

ON

ON

ON

OFF

ON

ON

ON

OFF

159

ON

ON

ON

ON

ON

OFF

OFF

ON

120

OFF

OFF

OFF

ON

ON

ON

ON

OFF

160

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

121

ON

OFF

OFF

ON

ON

ON

ON

OFF

161

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

122

OFF

ON

OFF

ON

ON

ON

ON

OFF

162

OFF

ON

OFF

OFF

OFF

ON

OFF

ON
ON

123

ON

ON

OFF

ON

ON

ON

ON

OFF

163

ON

ON

OFF

OFF

OFF

ON

OFF

124

OFF

OFF

ON

ON

ON

ON

ON

OFF

164

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

125

ON

OFF

ON

ON

ON

ON

ON

OFF

165

ON

OFF

ON

OFF

OFF

ON

OFF

ON

126

OFF

ON

ON

ON

ON

ON

ON

OFF

166

OFF

ON

ON

OFF

OFF

ON

OFF

ON

127

ON

ON

ON

ON

ON

ON

ON

OFF

167

ON

ON

ON

OFF

OFF

ON

OFF

ON

128

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

168

OFF

OFF

OFF

ON

OFF

ON

OFF

ON

129

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

169

ON

OFF

OFF

ON

OFF

ON

OFF

ON

130

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

170

OFF

ON

OFF

ON

OFF

ON

OFF

ON

131

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

171

ON

ON

OFF

ON

OFF

ON

OFF

ON

132

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

172

OFF

OFF

ON

ON

OFF

ON

OFF

ON

133

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

173

ON

OFF

ON

ON

OFF

ON

OFF

ON

134

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

174

OFF

ON

ON

ON

OFF

ON

OFF

ON

135

ON

ON

ON

OFF

OFF

OFF

OFF

ON

175

ON

ON

ON

ON

OFF

ON

OFF

ON

136

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

176

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

137

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

177

ON

OFF

OFF

OFF

ON

ON

OFF

ON

138

OFF

ON

OFF

ON

OFF

OFF

OFF

ON

178

OFF

ON

OFF

OFF

ON

ON

OFF

ON

139

ON

ON

OFF

ON

OFF

OFF

OFF

ON

179

ON

ON

OFF

OFF

ON

ON

OFF

ON

140

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

180

OFF

OFF

ON

OFF

ON

ON

OFF

ON

141

ON

OFF

ON

ON

OFF

OFF

OFF

ON

181

ON

OFF

ON

OFF

ON

ON

OFF

ON

142

OFF

ON

ON

ON

OFF

OFF

OFF

ON

182

OFF

ON

ON

OFF

ON

ON

OFF

ON

143

ON

ON

ON

ON

OFF

OFF

OFF

ON

183

ON

ON

ON

OFF

ON

ON

OFF

ON

144

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

184

OFF

OFF

OFF

ON

ON

ON

OFF

ON

145

ON

OFF

OFF

OFF

ON

OFF

OFF

ON

185

ON

OFF

OFF

ON

ON

ON

OFF

ON

146

OFF

ON

OFF

OFF

ON

OFF

OFF

ON

186

OFF

ON

OFF

ON

ON

ON

OFF

ON

147

ON

ON

OFF

OFF

ON

OFF

OFF

ON

187

ON

ON

OFF

ON

ON

ON

OFF

ON

148

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

188

OFF

OFF

ON

ON

ON

ON

OFF

ON

149

ON

OFF

ON

OFF

ON

OFF

OFF

ON

189

ON

OFF

ON

ON

ON

ON

OFF

ON

150

OFF

ON

ON

OFF

ON

OFF

OFF

ON

190

OFF

ON

ON

ON

ON

ON

OFF

ON

C3417M-B (11/06)

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

SWITCH SETTING
SPECTRA
ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8

191

ON

ON

ON

ON

ON

ON

OFF

ON

223

ON

ON

ON

ON

ON

OFF

ON

192

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

224

OFF

OFF

OFF

OFF

OFF

ON

ON

ON
ON

193

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

225

ON

OFF

OFF

OFF

OFF

ON

ON

ON

194

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

226

OFF

ON

OFF

OFF

OFF

ON

ON

ON

195

ON

ON

OFF

OFF

OFF

OFF

ON

ON

227

ON

ON

OFF

OFF

OFF

ON

ON

ON
ON

196

OFF

OFF

ON

OFF

OFF

OFF

ON

ON

228

OFF

OFF

ON

OFF

OFF

ON

ON

197

ON

OFF

ON

OFF

OFF

OFF

ON

ON

229

ON

OFF

ON

OFF

OFF

ON

ON

ON

198

OFF

ON

ON

OFF

OFF

OFF

ON

ON

230

OFF

ON

ON

OFF

OFF

ON

ON

ON
ON

199

ON

ON

ON

OFF

OFF

OFF

ON

ON

231

ON

ON

ON

OFF

OFF

ON

ON

200

OFF

OFF

OFF

ON

OFF

OFF

ON

ON

232

OFF

OFF

OFF

ON

OFF

ON

ON

ON

201

ON

OFF

OFF

ON

OFF

OFF

ON

ON

233

ON

OFF

OFF

ON

OFF

ON

ON

ON

202

OFF

ON

OFF

ON

OFF

OFF

ON

ON

234

OFF

ON

OFF

ON

OFF

ON

ON

ON

203

ON

ON

OFF

ON

OFF

OFF

ON

ON

235

ON

ON

OFF

ON

OFF

ON

ON

ON

204

OFF

OFF

ON

ON

OFF

OFF

ON

ON

236

OFF

OFF

ON

ON

OFF

ON

ON

ON

205

ON

OFF

ON

ON

OFF

OFF

ON

ON

237

ON

OFF

ON

ON

OFF

ON

ON

ON

206

OFF

ON

ON

ON

OFF

OFF

ON

ON

238

OFF

ON

ON

ON

OFF

ON

ON

ON

207

ON

ON

ON

ON

OFF

OFF

ON

ON

239

ON

ON

ON

ON

OFF

ON

ON

ON
ON

208

OFF

OFF

OFF

OFF

ON

OFF

ON

ON

240

OFF

OFF

OFF

OFF

ON

ON

ON

209

ON

OFF

OFF

OFF

ON

OFF

ON

ON

241

ON

OFF

OFF

OFF

ON

ON

ON

ON

210

OFF

ON

OFF

OFF

ON

OFF

ON

ON

242

OFF

ON

OFF

OFF

ON

ON

ON

ON
ON

211

ON

ON

OFF

OFF

ON

OFF

ON

ON

243

ON

ON

OFF

OFF

ON

ON

ON

212

OFF

OFF

ON

OFF

ON

OFF

ON

ON

244

OFF

OFF

ON

OFF

ON

ON

ON

ON

213

ON

OFF

ON

OFF

ON

OFF

ON

ON

245

ON

OFF

ON

OFF

ON

ON

ON

ON

214

OFF

ON

ON

OFF

ON

OFF

ON

ON

246

OFF

ON

ON

OFF

ON

ON

ON

ON

215

ON

ON

ON

OFF

ON

OFF

ON

ON

247

ON

ON

ON

OFF

ON

ON

ON

ON

216

OFF

OFF

OFF

ON

ON

OFF

ON

ON

248

OFF

OFF

OFF

ON

ON

ON

ON

ON

217

ON

OFF

OFF

ON

ON

OFF

ON

ON

249

ON

OFF

OFF

ON

ON

ON

ON

ON

218

OFF

ON

OFF

ON

ON

OFF

ON

ON

250

OFF

ON

OFF

ON

ON

ON

ON

ON

219

ON

ON

OFF

ON

ON

OFF

ON

ON

251

ON

ON

OFF

ON

ON

ON

ON

ON
ON

220

OFF

OFF

ON

ON

ON

OFF

ON

ON

252

OFF

OFF

ON

ON

ON

ON

ON

221

ON

OFF

ON

ON

ON

OFF

ON

ON

253

ON

OFF

ON

ON

ON

ON

ON

ON

222

OFF

ON

ON

ON

ON

OFF

ON

ON

254

OFF

ON

ON

ON

ON

ON

ON

ON

C3417M-B (11/06)

13

Specifications
GENERAL

ELECTRICAL (Dome Drive Only)

Construction
Back Box
Dome Drive
Lower Dome
Cable Entry (Back Box)
Pan Movement
Vertical Tilt
Manual Pan/Tilt Speeds*
Pan

Input Voltage

Tilt
Preset Speeds
Pan
Tilt
Environment
In-Ceiling
Environmental In-Ceiling
Operating Temperature
In-Ceiling Indoor
Environmental In-Ceiling
Maximum
Minimum

Weight (approximate)
Back Box
In-Ceiling Indoor
Environmental In-Ceiling
Dome Drive
Lower Dome
In-Ceiling Indoor
Environmental In-Ceiling

Plastic
Aluminum, thermoplastic
Acrylic
0.75-inch conduit fitting
360° continuous pan rotation
Unobstructed +2° to -92°
0.1°- 80°/sec manual operation,
150°/sec turbo
0.1°- 40°/sec manual operation
400°/sec
200°/sec
Indoor
Outdoor

18-32 VAC; 24 VAC nominal
22-27 VDC; 24 VDC nominal

Input Power
24 VAC
24 VDC
Fuse
Auxiliary Outputs
Alarm Inputs
Relay Contacts
Type
Voltage
Current

23 VA nominal (indoor, without heater)
73 VA nominal (outdoor, with heater)
0.7 A nominal (indoor, without heater)
3 A nominal (outdoor, without heater)
1.25 A
2 (Spectra IV SE only)
7 (Spectra IV SE only)
AUX 2 Output
AUX 1
Form C
Open collector
transistor output
Low voltage (<40 V) 32 VDC maximum
2 A maximum
150 mA maximum

Environmental In-Ceiling

In-Ceiling
7.5 (19.0)

9.9 (25.2)

32° to 122°F (0° to 50°C)
(Assumes no wind chill factor)
140°F (60°C) absolute maximum;
122°F (50°C) sustained maximum
-60°F (-51.1°C) absolute minimum;
prevents icing at sustained
minimum of -50°F (-45°C); de-ices
0.1 inch (2.5 mm) within 3 hours
after power-up

1.5 lb (0.68 kg)
2.1 lb (0.95 kg)
3.3 lb (1.48 kg)
0.2 lb (0.09 kg)
0.6 lb (0.27 kg)

4.4
(11.0)

5.2
(13.2)

4.3
(10.9)

3.5
(8.8)
5.9 (15.0)
8.9 (22.6)

5.9 (15.0)
8.2 (20.8)

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES.

*For variable-speed operation an appropriate controller is
required. With fixed-speed controllers, pan/tilt speed is 20°/sec.
The CM6700/CM6800 controller with the KBD200A keyboard has
programmable fixed speeds.

The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the
European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures
for recycling this equipment.

14

C3417M-B (11/06)

PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective
in material or workmanship for a period of one year after the date of
shipment.

If a warranty repair is required, the Dealer must contact Pelco at
(800)þ289-9100 or (559) 292-1981 to obtain a Repair Authorization number
(RA), and provide the following information:

Exceptions to this warranty are as noted below:

1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem

• Five years on FR/FT/FS Series fiber optic products and TW3000 Series
unshielded twisted pair transmission products.
• Three years on Spectra® IV products.
• Three years on Genex® Series products (multiplexers, server, and keyboard).
• Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models, which have a five-year warranty.
• Three years on PMCL200/300/400 Series LCD monitors.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/
DF8 Series fixed dome products.
• Two years on Spectra III™, Esprit®, ExSite™, and PS20 scanners, including
when used in continuous motion applications.
• Two years on Esprit and WW5700 Series window wiper (excluding wiper
blades).
• Two years (except lamp and color wheel) on Digital Light Processing (DLP®)
displays. The lamp and color wheel will be covered for a period of 90 days.
The air filter is not covered under warranty.
• Eighteen months on DX Series digital video recorders, NVR300 Series
network video recorders, and Endura™ Series distributed network-based
video products.
• One year (except video heads) on video cassette recorders (VCRs). Video
heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date
of Pelco shipment. All goods requiring warranty repair shall be sent freight
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence,
infringement of any rights of any party or product liability, relating to the
Products shall not exceed the price paid by the Dealer to Pelco for such
Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third
parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer
may also have additional rights, which are subject to variation from state to
state.

If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which
the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call
the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and
refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned
CA or RA number and freight should be prepaid. Ship to the appropriate address
below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico,
send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico
and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933

REVISION HISTORY
Manual #
C3417M
C3417M-A
C3417M-B

Date
8/06
9/06
11/06

Comments
Original version.
Corrected illustration 7.
Inserted compatibility table. Added serial port settings to Table E.

Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura, ExSite, and Spectra III are trademarks of Pelco.
DLP is a registered trademark of Texas Instruments, Inc.

©Copyright 2006, Pelco. All rights reserved.

Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
www.pelco.com
ISO9001

Australia

| Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden | The Netherlands | United Arab Emirates | United Kingdom | United States



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Keywords                        : Camera Site Equipment|Camera Systems|Spectra High Speed Domes
Creator Tool                    : FrameMaker 7.1
Modify Date                     : 2006:11:28 15:34:57-08:00
Create Date                     : 2006:11:16 14:29:36Z
Metadata Date                   : 2006:11:28 15:34:57-08:00
Format                          : application/pdf
Title                           : Pelco_Spectra_IV_in_Ceilings_Back_Box_manual
Creator                         : .
Subject                         : Camera Site Equipment|Camera Systems|Spectra High Speed Domes
Description                     : C3417MB
Document ID                     : uuid:b8d1d5fc-56c1-4e03-b55f-36edd673b5bd
Instance ID                     : uuid:6a8d6bea-fc50-4b08-82f8-e71c4f0070e5
Page Count                      : 16
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu