MCS*E Series
Master Power Supply
Installation/
Operation Manual
C655M (6/99)

Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120

CONTENTS
Section

Page

IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3
DESCRIPTION ................................................................................................................... 3
MODELS .................................................................................................................... 3
APPLICATION EXAMPLES ....................................................................................... 4
INSTALLATION ................................................................................................................... 4
INPUT CONNECTIONS ............................................................................................. 4
OUTPUT CONNECTIONS ......................................................................................... 5
MAINTENANCE ................................................................................................................. 7
SPECIFICATIONS .............................................................................................................. 7
WARRANTY AND RETURN INFORMATION .................................................................... 8

LIST OF ILLUSTRATIONS
Figure
1

Page
MCS*E Series Unit Wiring Connector Diagram ................................................... 5

LIST OF TABLES
Table
A
B
C
D

2

Page
Product Capacity .................................................................................................. 4
Main Fuse Value Table ......................................................................................... 4
Recommended Wiring Distances ......................................................................... 6
Required Wire Gauge .......................................................................................... 6

Pelco Manual C655M (6/99)

IMPORTANT SAFEGUARDS AND WARNINGS
Observe the following WARNINGS before installing and using this product.
1.

Installation and servicing should be done by qualified service personnel only and conform to all local codes.

2.

Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to
rain and moisture.

3.

Only use replacement parts Pelco recommends.

4.

After replacing/repairing this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been
connected to line circuitry.

The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of
electric shock is present within this
unit.

CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.

This symbol indicates that there
are important operating and maintenance instructions in the literature accompanying this unit.

Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.

DESCRIPTION
The MCS*E Series consists of multi-output 24 VAC indoor power supplies. These power
supplies provide output for 4, 8, or 16 cameras from a single source and come in 2, 5, 10,
and 20 amp capacities. The power supplies allow for 120 VAC line input. Higher capacity
models can handle pan and tilt and receiver operation, in addition to the camera, for integrated systems such as Spectra® and Esprit™.
All MCS*E Series models come with an individual glass fuse for each output channel.

Pelco Manual C655M (6/99)

Model
Number

Outputs

Total Output
Current (Amps)

Total Output
Power (vA)

Max Power Per
Output (vA)

Input Current
(Amps)

Output Voltage
(VAC)

Fuses

Surge
Protection

On/Off Switch

Power LED

Max Current Per
Output (Amps)

MODELS

MCS4-2E
MCS8-5E
MCS16-10E

4
8
16

2
5
10

48
120
240

1
3
3

24
72
72

0.44
1.1
2.2

24
24
24

X
X
X

X
X
X

X
X
X

X
X
X

MCS16-20E

16

20

480

3

72

4.4

24

X

X

X

X

3

APPLICATION EXAMPLES
Table A contains examples of products and the number of units that can be powered by
each power supply, and is based on the vA rating of each product.

Table A. Product Capacity
Power Supply Model
Product
CCD Camera (12 vA maximum)
DF5/DF5S with camera (3 vA)
DF8A/PDF8 (12 vA maximum)
Indoor Spectra® (30 vA)
Esprit™ (50 vA)

MCS4-2E

MCS8-5E

MCS16-10E

MCS16-20E

4
4
4
1
—

8
8
8
4
2

16
16
16
8
4

16
16
16
16
8

INSTALLATION
The following items are supplied:
1
2
2

MCS*E Series Power Supply
Spare fuses
Wire nuts

To install an MCS Series power supply, perform the following steps:
1.

Decide where to install the unit.

2.

Open the lid on the unit by removing the 8-32 Phillips screw.

3.

Drill holes in the mounting surface. Use the unit as a template.

4.

Attach the unit securely with four fasteners (not supplied) of the appropriate length.
You can use fasteners up to 5/16-inch (0.80 cm) in diameter.

5.

Punch out the necessary knockouts. (There are six knockout holes on the top and two
on the bottom.)

6.

Install 1/2-inch (1.27 cm) or 3/4-inch (1.91 cm) conduit fittings where necessary (conduit fittings not provided).

INPUT CONNECTIONS
Table B. Main Fuse Value Table
Fuse Location
Main
Individual Output

WARNING:

Pelco will not be
liable for any
damages resulting from
incorrect wiring or improper loading of an
MCS*E Series power
supply.

4

MCS4-2E
1A
1A

MCS8-5E
1.6 A
3A

MCS16-10E
3A
3A

MCS16-20E
5A
3A

1.

Verify that the on/off switch inside the box is OFF.

2.

Remove the high voltage compartment panel inside the box.

3.

Attach the 120 input wires to the flying leads in the compartment with the supplied
wire nuts (Brown – AC Line; Blue – AC Neutral).

4.

Attach the input ground wire to the stud inside the compartment with the supplied
washer and nut.

5.

Replace the access panel.

Pelco Manual C655M (6/99)

OUTPUT CONNECTIONS
Perform the following steps to attach 24 VAC devices to the MCS*E Series power supply:
1.

Refer to Tables C and D in this manual or the wiring table on the unit’s lid to determine
the output connection needed for your devices.

2.

Refer to Figure 1 for the proper connector strip connections.

3.

For each device, attach one output wire to the common terminal. Attach the second
wire to the appropriate 24 VAC terminal.

4.

When you finish the wiring connections, double check the installation for safety purposes.

5.

Power up the unit with the on/off switch.

6.

Use a voltmeter to verify that used outputs are at appropriate voltage levels.

7.

Close the lid and secure it using the 8-32 Phillips screw.

24V
1

2

3

4

5

6

7

8

9

10 11 12

Main Fuse

COM

ON
OFF
Power

OUTPUT 1 THRU 8

OUTPUT 9

Figure 1. MCS*E Series Unit Wiring Connector Diagram

Pelco Manual C655M (6/99)

5

Table C. Recommended Wiring Distances
The following are the recommended maximum distances (transformer to load) and are calculated with a 10-percent voltage drop.
(Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Distances are calculated in feet; values in
parentheses are meters.
Input
Voltage

Total vA
Consumed

20

Wire Gauge
18

16

24 VAC

10
20
30
50

283 (86)
141 (42)
94 (28)
56 (17)

451 (137)
225 (68)
150 (45)
90 (27)

716 (218)
358 (109)
238 (72)
143 (43)

You can use Table D as a guide to determine the necessary wire gauge (AWG) for various cable distances that provide 24 VAC
power. Or use it in a reverse fashion to determine the maximum allowable cable distance for a particular wire gauge. Table D applies
when using 2-conductor copper wire, with characteristics similar to West Penn 221-227 unshielded cable. Calculations are based on
a 10-percent voltage drop (generally the maximum allowable drop for AC-powered devices).
The minimum acceptable voltage is calculated as follows:

24.0 VAC
– 02.4 (10%)
21.6 (Minimum Acceptable Voltage)

The minimum acceptable voltage used to create Table D was 21.6 volts. Therefore, the 24-volt output has an acceptable range from
24 volts down to 21.6 volts.

Table D. Required Wire Gauge

PT570
Pan/Tilt

Esprit™
Pan/Tilt

14-inch
Intercept®

CX9000
Receivers

Outdoor
Spectra®

20VA

30VA

40VA

50VA

60VA

70VA

80VA

90VA

100VA

200VA

1000

12-14

12

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

900

12-14

12

12

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

➡

PT480
Pan/Tilt

10VA

WIRE
DIST
(feet)

CCD
Camera

Indoor
Spectra®

Recommended Wire Gauge Table (AWG)

Equipment Loads

800

12-14

12

12

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

700

12-16

12

12

12

N/A

N/A

N/A

N/A

N/A

N/A

N/A

600

12-16

12

12

12

N/A

N/A

N/A

N/A

N/A

N/A

N/A

500

12-16

12-14

12

12

12

N/A

N/A

N/A

N/A

N/A

N/A

400

12-18

12-14

12

12

12

12

12

N/A

N/A

N/A

N/A

300

12-18

12-16

12-14

12

12

12

12

12

12

N/A

N/A

200

12-20

12-18

12-16

12-14

12-14

12

12

12

12

12

N/A

100

12-22

12-20

12-18

12-18

12-16

12-16

12-16

12-14

12-14

12-14

12

➡

XX-XX

Recommended Wire Gauge (AWG) Using 24 VAC
N/A – Distance and Load Not Recommended For Any Wire Size Between 12-22 (AWG)

6

Pelco Manual C655M (6/99)

MAINTENANCE
There are no user-serviceable parts except for the fuses. If the transformer in the unit does
not work properly, the entire power supply needs to be returned to the factory for repair. Refer to the Warranty and Return Information section of this manual for instructions on returning the power supply for repair.
Clean the outer surface of the power supply with a nonabrasive cleaning cloth and antistatic cleaner. Do not use kerosene or similar substances that may damage the surface.

SPECIFICATIONS
MECHANICAL
Cable Entry:

Knockouts for either 1/2-inch (1.27 cm) or 3/4-inch (1.91 cm) conduit

Fuse Size:

All fuses are 5 x 20 mm

ELECTRICAL
Input Voltage:

120 VAC, 60 Hz

Output Voltage:

24 VAC

Required Input
Current:

See Models section

Output Fuse Ratings
MCS4-2E:
1A
MCS8-5E:
3A
MCS16-10E:
3A
MCS16-20E:
3A
Input Connectors:

Wire nut

Output Connectors: Screw-type barrier strips
Input Wire Size:

12-16 gauge solid wire

Output Wire Size:

12-22 gauge solid or stranded wire

Recommended
Wiring Distances:

See Table C

GENERAL
Construction:

Steel

Finish:

Black polyester powder coat

Environment:

Indoor

Dimensions:

16.13 in. H x 10.86 in. W x 4.37 in. D (40.97 x 27.58 x 11.10 cm)

Unit Weight
MCS4-2E:
MCS8-5E:
MCS16-10E:
MCS16-20E:

13.45 lb (6.10 kg)
14.70 lb (6.67 kg)
16.60 lb (7.53 kg)
19.70 lb (8.94 kg)

Ratings:

NEMA 1

(Design and product specifications subject to change without notice.)

Pelco Manual C655M (6/99)

7

PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex ® Series products (multiplexers, server, and keyboard).
• Three years on Camclosure ® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy ®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
• Two years on Spectra ®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
• Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades).
• Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura ™ Series distributed network-based video products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933

REVISION HISTORY
Manual #
C655M

Date
6/99

Comments
Original version.

Pelco and the Pelco logo are registered trademarks of Pelco.
Endura is a trademark of Pelco.

8

© Copyright 1999, Pelco. All rights reserved.

Pelco Manual C655M (6/99)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Fill forms, Extract, Assemble, Print high-res
Page Count                      : 8
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:b9ed0258-e8b2-11d9-a9b5-000a95a25184
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Create Date                     : 2005:04:22 21:15:28Z
Modify Date                     : 2005:06:29 08:30:29-07:00
Metadata Date                   : 2005:06:29 08:30:29-07:00
Document ID                     : uuid:5679a722-cbd3-11d9-a7a8-000a95a25184
Format                          : application/pdf
EXIF Metadata provided by EXIF.tools

Navigation menu