Pelco Power Supply Mcs16 10E 16 10 240 3 72 2 24 X Users Manual
MCS8-5E 8 5 120 3 72 1.1 24 X X X X to the manual 7e61a29b-def6-4bb6-b0e7-74444ca0d668
2015-02-02
: Pelco Pelco-Pelco-Power-Supply-Mcs16-10E-16-10-240-3-72-2-2-24-X-X-X-X-Users-Manual-441186 pelco-pelco-power-supply-mcs16-10e-16-10-240-3-72-2-2-24-x-x-x-x-users-manual-441186 pelco pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
® MCS*E Series Master Power Supply Installation/ Operation Manual C655M (6/99) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3 DESCRIPTION ................................................................................................................... 3 MODELS .................................................................................................................... 3 APPLICATION EXAMPLES ....................................................................................... 4 INSTALLATION ................................................................................................................... 4 INPUT CONNECTIONS ............................................................................................. 4 OUTPUT CONNECTIONS ......................................................................................... 5 MAINTENANCE ................................................................................................................. 7 SPECIFICATIONS .............................................................................................................. 7 WARRANTY AND RETURN INFORMATION .................................................................... 8 LIST OF ILLUSTRATIONS Figure 1 Page MCS*E Series Unit Wiring Connector Diagram ................................................... 5 LIST OF TABLES Table A B C D 2 Page Product Capacity .................................................................................................. 4 Main Fuse Value Table ......................................................................................... 4 Recommended Wiring Distances ......................................................................... 6 Required Wire Gauge .......................................................................................... 6 Pelco Manual C655M (6/99) IMPORTANT SAFEGUARDS AND WARNINGS Observe the following WARNINGS before installing and using this product. 1. Installation and servicing should be done by qualified service personnel only and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Only use replacement parts Pelco recommends. 4. After replacing/repairing this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry. The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. DESCRIPTION The MCS*E Series consists of multi-output 24 VAC indoor power supplies. These power supplies provide output for 4, 8, or 16 cameras from a single source and come in 2, 5, 10, and 20 amp capacities. The power supplies allow for 120 VAC line input. Higher capacity models can handle pan and tilt and receiver operation, in addition to the camera, for integrated systems such as Spectra® and Esprit™. All MCS*E Series models come with an individual glass fuse for each output channel. Pelco Manual C655M (6/99) Model Number Outputs Total Output Current (Amps) Total Output Power (vA) Max Power Per Output (vA) Input Current (Amps) Output Voltage (VAC) Fuses Surge Protection On/Off Switch Power LED Max Current Per Output (Amps) MODELS MCS4-2E MCS8-5E MCS16-10E 4 8 16 2 5 10 48 120 240 1 3 3 24 72 72 0.44 1.1 2.2 24 24 24 X X X X X X X X X X X X MCS16-20E 16 20 480 3 72 4.4 24 X X X X 3 APPLICATION EXAMPLES Table A contains examples of products and the number of units that can be powered by each power supply, and is based on the vA rating of each product. Table A. Product Capacity Power Supply Model Product CCD Camera (12 vA maximum) DF5/DF5S with camera (3 vA) DF8A/PDF8 (12 vA maximum) Indoor Spectra® (30 vA) Esprit™ (50 vA) MCS4-2E MCS8-5E MCS16-10E MCS16-20E 4 4 4 1 — 8 8 8 4 2 16 16 16 8 4 16 16 16 16 8 INSTALLATION The following items are supplied: 1 2 2 MCS*E Series Power Supply Spare fuses Wire nuts To install an MCS Series power supply, perform the following steps: 1. Decide where to install the unit. 2. Open the lid on the unit by removing the 8-32 Phillips screw. 3. Drill holes in the mounting surface. Use the unit as a template. 4. Attach the unit securely with four fasteners (not supplied) of the appropriate length. You can use fasteners up to 5/16-inch (0.80 cm) in diameter. 5. Punch out the necessary knockouts. (There are six knockout holes on the top and two on the bottom.) 6. Install 1/2-inch (1.27 cm) or 3/4-inch (1.91 cm) conduit fittings where necessary (conduit fittings not provided). INPUT CONNECTIONS Table B. Main Fuse Value Table Fuse Location Main Individual Output WARNING: Pelco will not be liable for any damages resulting from incorrect wiring or improper loading of an MCS*E Series power supply. 4 MCS4-2E 1A 1A MCS8-5E 1.6 A 3A MCS16-10E 3A 3A MCS16-20E 5A 3A 1. Verify that the on/off switch inside the box is OFF. 2. Remove the high voltage compartment panel inside the box. 3. Attach the 120 input wires to the flying leads in the compartment with the supplied wire nuts (Brown – AC Line; Blue – AC Neutral). 4. Attach the input ground wire to the stud inside the compartment with the supplied washer and nut. 5. Replace the access panel. Pelco Manual C655M (6/99) OUTPUT CONNECTIONS Perform the following steps to attach 24 VAC devices to the MCS*E Series power supply: 1. Refer to Tables C and D in this manual or the wiring table on the unit’s lid to determine the output connection needed for your devices. 2. Refer to Figure 1 for the proper connector strip connections. 3. For each device, attach one output wire to the common terminal. Attach the second wire to the appropriate 24 VAC terminal. 4. When you finish the wiring connections, double check the installation for safety purposes. 5. Power up the unit with the on/off switch. 6. Use a voltmeter to verify that used outputs are at appropriate voltage levels. 7. Close the lid and secure it using the 8-32 Phillips screw. 24V 1 2 3 4 5 6 7 8 9 10 11 12 Main Fuse COM ON OFF Power OUTPUT 1 THRU 8 OUTPUT 9 Figure 1. MCS*E Series Unit Wiring Connector Diagram Pelco Manual C655M (6/99) 5 Table C. Recommended Wiring Distances The following are the recommended maximum distances (transformer to load) and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Distances are calculated in feet; values in parentheses are meters. Input Voltage Total vA Consumed 20 Wire Gauge 18 16 24 VAC 10 20 30 50 283 (86) 141 (42) 94 (28) 56 (17) 451 (137) 225 (68) 150 (45) 90 (27) 716 (218) 358 (109) 238 (72) 143 (43) You can use Table D as a guide to determine the necessary wire gauge (AWG) for various cable distances that provide 24 VAC power. Or use it in a reverse fashion to determine the maximum allowable cable distance for a particular wire gauge. Table D applies when using 2-conductor copper wire, with characteristics similar to West Penn 221-227 unshielded cable. Calculations are based on a 10-percent voltage drop (generally the maximum allowable drop for AC-powered devices). The minimum acceptable voltage is calculated as follows: 24.0 VAC – 02.4 (10%) 21.6 (Minimum Acceptable Voltage) The minimum acceptable voltage used to create Table D was 21.6 volts. Therefore, the 24-volt output has an acceptable range from 24 volts down to 21.6 volts. Table D. Required Wire Gauge PT570 Pan/Tilt Esprit™ Pan/Tilt 14-inch Intercept® CX9000 Receivers Outdoor Spectra® 20VA 30VA 40VA 50VA 60VA 70VA 80VA 90VA 100VA 200VA 1000 12-14 12 N/A N/A N/A N/A N/A N/A N/A N/A N/A 900 12-14 12 12 N/A N/A N/A N/A N/A N/A N/A N/A ➡ PT480 Pan/Tilt 10VA WIRE DIST (feet) CCD Camera Indoor Spectra® Recommended Wire Gauge Table (AWG) Equipment Loads 800 12-14 12 12 N/A N/A N/A N/A N/A N/A N/A N/A 700 12-16 12 12 12 N/A N/A N/A N/A N/A N/A N/A 600 12-16 12 12 12 N/A N/A N/A N/A N/A N/A N/A 500 12-16 12-14 12 12 12 N/A N/A N/A N/A N/A N/A 400 12-18 12-14 12 12 12 12 12 N/A N/A N/A N/A 300 12-18 12-16 12-14 12 12 12 12 12 12 N/A N/A 200 12-20 12-18 12-16 12-14 12-14 12 12 12 12 12 N/A 100 12-22 12-20 12-18 12-18 12-16 12-16 12-16 12-14 12-14 12-14 12 ➡ XX-XX Recommended Wire Gauge (AWG) Using 24 VAC N/A – Distance and Load Not Recommended For Any Wire Size Between 12-22 (AWG) 6 Pelco Manual C655M (6/99) MAINTENANCE There are no user-serviceable parts except for the fuses. If the transformer in the unit does not work properly, the entire power supply needs to be returned to the factory for repair. Refer to the Warranty and Return Information section of this manual for instructions on returning the power supply for repair. Clean the outer surface of the power supply with a nonabrasive cleaning cloth and antistatic cleaner. Do not use kerosene or similar substances that may damage the surface. SPECIFICATIONS MECHANICAL Cable Entry: Knockouts for either 1/2-inch (1.27 cm) or 3/4-inch (1.91 cm) conduit Fuse Size: All fuses are 5 x 20 mm ELECTRICAL Input Voltage: 120 VAC, 60 Hz Output Voltage: 24 VAC Required Input Current: See Models section Output Fuse Ratings MCS4-2E: 1A MCS8-5E: 3A MCS16-10E: 3A MCS16-20E: 3A Input Connectors: Wire nut Output Connectors: Screw-type barrier strips Input Wire Size: 12-16 gauge solid wire Output Wire Size: 12-22 gauge solid or stranded wire Recommended Wiring Distances: See Table C GENERAL Construction: Steel Finish: Black polyester powder coat Environment: Indoor Dimensions: 16.13 in. H x 10.86 in. W x 4.37 in. D (40.97 x 27.58 x 11.10 cm) Unit Weight MCS4-2E: MCS8-5E: MCS16-10E: MCS16-20E: 13.45 lb (6.10 kg) 14.70 lb (6.67 kg) 16.60 lb (7.53 kg) 19.70 lb (8.94 kg) Ratings: NEMA 1 (Design and product specifications subject to change without notice.) Pelco Manual C655M (6/99) 7 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard). • Three years on Camclosure ® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty. • Two years on standard motorized or fixed focal length lenses. • Two years on Legacy ®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products. • Two years on Spectra ®, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications. • Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades). • Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura ™ Series distributed network-based video products. • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months. • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes). Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise. The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned. Method of return shipment shall be the same or equal to the method by which the item was received by Pelco. RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below. If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to: Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699 If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to: Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933 REVISION HISTORY Manual # C655M Date 6/99 Comments Original version. Pelco and the Pelco logo are registered trademarks of Pelco. Endura is a trademark of Pelco. 8 © Copyright 1999, Pelco. All rights reserved. Pelco Manual C655M (6/99)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Page Count : 8 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:b9ed0258-e8b2-11d9-a9b5-000a95a25184 Producer : Acrobat Distiller 5.0.5 for Macintosh Create Date : 2005:04:22 21:15:28Z Modify Date : 2005:06:29 08:30:29-07:00 Metadata Date : 2005:06:29 08:30:29-07:00 Document ID : uuid:5679a722-cbd3-11d9-a7a8-000a95a25184 Format : application/pdfEXIF Metadata provided by EXIF.tools