Pelco Security Camera Eh66X Users Manual EH66_EH66X Environmental Enclosures_manual
EH66X to the manual e7b4ddf9-4b75-459e-aa87-f348d8d3762f
2015-02-02
: Pelco Pelco-Pelco-Security-Camera-Eh66X-Users-Manual-441421 pelco-pelco-security-camera-eh66x-users-manual-441421 pelco pdf
Open the PDF directly: View PDF
.
Page Count: 20
| Download | |
| Open PDF In Browser | View PDF |
® EH66/EH66X Environmental Enclosures Installation/Operation Manual C411M-D (1/96) Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com (559) 292-1981 or (800) 289-9100 • FAX (559) 292-3827 or (800) 289-9150 Pelco Manual C411M-D (1/96) 17 TABLE OF CONTENTS Section Page 1.0 WARNINGS ........................................................................................................................................ 1 2.0 SCOPE ...............................................................................................................................................2 3.0 DESCRIPTION ...................................................................................................................................2 3.1 CERTIFICATIONS .................................................................................................................... 2 4.0 INSTALLATION .................................................................................................................................. 3 4.1 ELECTRICAL CONNECTIONS/BLOWER AND HEATER ........................................................ 3 4.2 INSTALLATION OF CAMERA/LENS ........................................................................................ 3 4.3 FIXED ENCLOSURE MOUNTING ........................................................................................... 5 4.4 PAN/TILT ENCLOSURE MOUNTING ....................................................................................... 6 4.5 WINDOW WIPER INSTALLATION ............................................................................................ 8 4.6 B66KIT/E624HB/H66KIT INSTALLATION ................................................................................ 9 5.0 CARE AND MAINTENANCE .............................................................................................................. 9 6.0 EXPLODED ASSEMBLY DIAGRAMS .............................................................................................. 10 7.0 MECHANICAL PARTS LISTS .......................................................................................................... 12 7.1 MECHANICAL PARTS LIST WW66 AND WW66-5/220 ASSEMBLY ..................................... 13 8.0 OPTIONAL ACCESSORIES ............................................................................................................ 14 9.0 SPECIFICATIONS ............................................................................................................................ 14 9.1 RECOMMENDED CABLE SIZE ............................................................................................. 15 9.2 POWER REQUIREMENTS FOR BLOWER, HEATER, ACCESSORIES ............................... 15 10.0 WARRANTY AND RETURN INFORMATION ................................................................................... 16 ii PELCO Manual C411M-C (1/96) LIST OF ILLUSTRATIONS Figure Page 1 EH66/EH66X Dimension Drawing ................................................................................................. 2 2 Wiring Diagram for Window Defroster, Wiper/Washer and Blower/Heater Assemblies ................. 4 3 EH66 Enclosure with Wall Mount .................................................................................................. 5 4 EH66 Enclosure with Pedestal/Ceiling Mount ............................................................................... 5 5 EH66 Enclosure with Pan/Tilt and Wall Mount .............................................................................. 6 6 EH66 Enclosure with Pan/Tilt and Pedestal/Ceiling Mount ........................................................... 6 7 Window Wiper Motor Installation ................................................................................................... 7 8 Mounting Hole Dimensions ........................................................................................................... 7 9 EH66 Enclosure Exploded Assembly Diagram ............................................................................. 9 10 WW66, WW66-5/220 Wiper Exploded Assembly Diagram ......................................................... 10 REVISION HISTORY Manual # Date Comments C411M 8/88 Original Manual C411M 5/91 Revision A. Revised to include new series models; cable distance information, and the addition of the WW66 installation information as well as new manual format C411M 11/92 Revision B. Revised to include new wiring diagram information for accessory kits as well as WW66 motor installation/mounting information. C411M-C 2/95 Revision C. Manual revised to include new dimension drawing; the addition of rubber grommet to WW66 BOM as per ECO #94-091; changes to the WW66 exploded view diagram as per ECO #94-233; installation instructions incorporated as per ECO #92-129; completely new EH66 exploded assembly drawing with new materials list; new mounting hole dimension drawing and window wiper assembly drawing as per ECO # 93-200; and minor corrections to wiring diagram. C411M-D 1/96 Revision D. Manual revised to include new wiper/washer pump as per ECO 95-431. Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks ofPelco. ©Copyright 1998, Pelco. All rights reserved. Endura and ExSite are trademarks of Pelco. Pelco Manual C411M-D (1/96) iii This page intentionally left blank. iv Pelco Manual C411M-D (1/96) INSTALLATION/OPERATION MANUAL MODEL EH66/EH66X SERIES ENVIRONMENTAL ENCLOSURES 1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry. 5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination. The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. Pelco Manual C411M-D (1/96) 1 2.0 SCOPE The information contained within this manual covers the EH66/EH66X Series environmental enclosure. 3.0 DESCRIPTION The EH66 Series is an all-weather environmental enclosure for 2/3" and 1" cameras with a maximum camera/ lens size of 7" W x 7" H x 22" L (17.7 cm x 17.7 cm x 55.8 cm). Rugged all aluminum construction protects the camera from adverse weather conditions. Built-in sun visor shields the lens from direct sunlight, and a vent cap allows heated air to escape from the interior. Removable lid with four secure latches provides convenient access. Camera is mounted on an adjustable rail/ sled. Two adjustable glands in the bottom of the enclosure permit easy cable entry. date intensified cameras. The EH66X Series will accept a maximum camera/lens size of 7" W x 7" H x 30" L (17.7 cm x 17.7 cm x 76.2 cm). Models With The Letters “HB” in the suffix come equipped with a factory installed filtered blower and wired blanket heater with thermostat controls. The heater activates when the internal temperature falls below 40° F (4.44° C). It is electrically insulated from the enclosure and provides 160 watts of heat. The blower provides 105 CFM and activates when the internal temperature reaches approximately 100° F (37.78° C). Internal temperature is reduced when the blower draws ambient air from a filtered intake port, circulates it through the enclosure, and exhausts it out the vent cap. Models With The Letter “L” in the suffix include tamper resistant locks which are keyed alike. The EH66X Series is the same as the EH66 Series except the enclosures have extra length to accommo3.1 CERTIFICATIONS Figure 1. EH66/EH66X Dimension Drawing 2 Model Number EH66 EH66/WW EH66B EH66B/WW EH66BL EH66H EH66HB EH66HB/WW EH66HB-3 EH66HBL EH66HBL/WW EH66HL EH66L EH66L/WW EH66X EH66X/WW EH66XB EH66XBL EH66XH EH66XHB EH66XHB/WW EH66XHBL EH66XHBL/WW EH66XHL EH66XL EH66XL/WW UL X X X X X X X X CE X X X X X X X X X X X X X X X X X X X X X X Pelco Manual C411M-D (1/96) 4.0 INSTALLATION NOTE: Cameras with a low optical centerline or using a large diameter lens require an elevation block (1 inch or 2 inch) for proper positioning. See Section 8.0, Optional Accessories, for the correct model number. Please check the contents of your package(s) for the following items before proceeding with the installation of the equipment. Quantity Item 3. 2 1/4-20 x .500 hex head screws to mount camera 1 5/32-inch Allen wrench for adjusting sled 1 Blower assembly (installed on models with “HB” in suffix only) 1 Heater assembly (installed on models with “HB” in suffix only) 2 Keys (for models with “L” in suffix only) Replace the camera/sled assembly onto the rail and slide along the rail to adjust the camera to maximum forward camera position; lock into place by tightening the Allen head screws. IMPORTANT: Set the focus for the shortest distance to extend the lens to the maximum length before positioning the camera/lens combinations. This will ensure that the lens has enough clearance and will not hit the window during focusing. 4. 4.1 ELECTRICAL CONNECTIONS – ENCLOSURES WITH BLOWER AND HEATER Factory installed heater and blower assemblies are factory pre-wired and only require connection of power to the terminal block (see Figure 2). Refer to Section 4.6 for field installed heater/blower kits. Loosen the cable gland nuts on the back of the enclosure (1/2-inch gland for video cable, 3/8-inch gland for power cable). Route the camera cables through the appropriate glands and connect to the camera. Wire the enclosure per wiring diagram provided (see Figure 2). Tighten the gland nuts for a snug fit around the cables. NOTE: The plate holding the two cable glands on the bottom of the enclosure is removable, which allows enough clearance for the connector assemblies to be inserted in or removed from the enclosure. This permits the connectors (i.e., lens connector, video connector, etc.) to be assembled somewhere other than the field and also allows the enclosure to be moved in the field without disassembling all the connectors. NOTE: In dusty locations, double filters can be installed. Loosen the two Allen head screws at the rear of the enclosure and pull the drawer open. Remove the acorn nuts at the rear of the housing and pull the end plate off for access to the filters. 5. Replace the lid and secure the latches. 6. Attach the enclosure to the appropriate mount or pan and tilt using the instructions provided with the mounting equipment. 4.2 INSTALLATION OF CAMERA/LENS To install the camera/lens, perform the following: 1. Remove the lid by unlatching the two latches on each side. 2. Remove the camera sled from the rail by loosening the two Allen head screws and attach the camera/ lens with the 1/4-20 hex head screws provided. Pelco Manual C411M-D (1/96) 3 to control Figure 2. Wiring Diagram for Window Defroster, Wiper/Washer and Blower/Heater Assemblies 4 Pelco Manual C411M-D (1/96) 4.3 FIXED ENCLOSURE MOUNTING 3. Attach the adjustable head to the mount. The are two types of mounts that can be used with the EH66 enclosure: wall, or pedestal/ceiling (see Figures 3 and 4). 4. Align the 1/4-20 threaded holes in the bottom of the EH66 enclosure with the holes in the tilt table of the adjustable head. Fasten the enclosure to the table using 1/4-20 fasteners (not to exceed 5/8" in length, minimum two (2). Select the appropriate mount (WM2000 for wall mounting or PM2000/PM2010 for pedestal mounting) for the application. 5. If you have not already done so, install the camera/ lens according to the instructions in Section 4.2 of this manual. The mount must be equipped with the AH2000 adjustable head for precise positioning of the enclosure. 6. Make all necessary electrical connections. 7. Position the enclosure to the desired viewing angle and tighten all fasteners. Instructions for mounting the enclosure are as follows: 1. 2. Secure the mount to a suitable load bearing surface. Use fasteners with a minimum 1/4-inch diameter. Figure 3. EH66 Enclosure with Wall Mount Pelco Manual C411M-D (1/96) Figure 4. EH66 Enclosure with Pedestal/Ceiling Mount 5 4.4 PAN/TILT ENCLOSURE MOUNTING 4. Attach the pan/tilt to the mount. The pan/tilt control connect should be positioned towards the building/ mounting location. Note the “front” label on the pan/tilt. 5. If you have not already done so, install the camera/lens according to the instructions in Section 4.2 of this manual. 6. Balance the enclosure/camera/lens load on the tilt table. Adjust the positioning as needed to align the mounting holes. A minimum of two 1/4-20 x 5/8" fasteners must be used. Secure the enclosure to the tilt table. 7. Make all necessary electrical connections. Be sure to leave an adequate loop of cables between the enclosure and the pan/tilt, and the enclosure and the rigid mount to prevent binding and/or strain on the cables (see Figures 5 and 6). The EH66 enclosure can also be mounted to a pan/tilt assembly in addition to the wall or pedestal/ceiling mount. To include the pan/tilt assembly in your configuration, perform the following steps: 1. Select the appropriate mount (WM2000 for wall mounting, PM2000/PM2010 for pedestal mount) for the application. 2. Select the appropriate pan/tilt for the application. Considerations must be made as to enclosure options, camera and lens selection, and environmental conditions. All of these will affect the pan/tilt selection. 3. Secure the mount to a suitable load bearing surface. Use fasteners with a minimum 1/4-inch diameter. Figure 5. EH66 Enclosure with Pan/Tilt and Wall Mount 6 Figure 6. EH66 Enclosure with Pan/Tilt and Pedestal/Ceiling Mount Pelco Manual C411M-D (1/96) 4.5 WINDOW WIPER INSTALLATION 8. Attach the water reservoir bottle to the rear of the EH66 enclosure by removing the two (2) top acorn nuts. 9. Place the bottle mount on the protruding studs and replace the acorn nuts. To install the window wiper kit, perform the following steps and refer to Figures 7 and 8: 1. Turn the EH66 enclosure over so the bottom is facing up. 2. If necessary, lay out the locations of the four (4) .171-inch diameter mounting holes using the dimensions given in Figure 8. 4. Attach the wiper box using the four (4) mounting holes, inserting the wire leads through one of the rubber grommets. 5. Adjust the force of the wiper blade against the glass by applying force to the arms toward the glass or away from glass. 6. Attach wiper wire leads inside the enclosure as shown in Figure 2. 7. Connect cable to wiper box. 10. Attach the water hose to the bottle from the wiper. Figure 7. Window Wiper Motor Installation Figure 8. Mounting Hole Dimensions Pelco Manual C411M-D (1/96) 7 4.6 B66KIT/E624HB/H66KIT INSTALLATION All heater and blower kits are supplied partially assembled. Install in the enclosure according to the following instructions: 1. Remove the round cap on the rear of the enclosure and the two (2) 8-32 screws and nuts located on each side of the opening above the horizontal line. 2. Remove the two (2) acorn nuts holding the air box to the heater/blower assembly; remove the air box. 3. Install the assembly in the enclosure utilizing the two (2) open holes for mounting; reinstall the air box on the outside of the enclosure and secure the assembly with the two (2) acorn nuts. 4. Mount the two (2) heater strips onto the sides of the enclosure with the four (4) sheet metal screws provided. 5. Wire input power to the terminal block on the top of the heater/blower assembly as shown in Figure 2. 5.0 CARE AND MAINTENANCE Maintenance performed at regularly scheduled intervals will help prolong the operational life and appearance of the equipment. 1. Clean the plexi-glass window with a mild nonabrasive detergent in water and a soft cloth regularly to help maintain picture clarity. For a heavily soiled window, use vinyl cleaner. 2. Clean or replace the fiberglass filter pad in the blower assembly periodically. To replace or clean the filter pad, perform the following steps: a. Remove the two acorn nuts at the rear of the housing and pull the end plate off for access to the filter. b. Remove the wire screen and filter pad. Clean the pad with water and mild detergent, dry thoroughly, and reinsert or replace with a new pad. (Replacement pads, part number EH14050COMP, are available from Pelco.) NOTE: Pelco offers a 24-hour, seven-day-a week Technical Assistance Program (TAP) designed to assist any customer with a technical problem involving Pelco equipment whether it’s the weekend or late at night. For technical assistance dial (800) 289-9100 and you will be connected to a Pelco TAP member who is trained to answer your questions. Pelco also guarantees one-day turnaround on any Pelco equipment sent in for repair. This includes warranty and non-warranty items. Refer to the section on “Warranty and Return Information” in this manual for the proper procedure. 8 Pelco Manual C411M-D (1/96) 6.0 EXPLODED ASSEMBLY DIAGRAMS See Figures 9 and 10 for exploded assembly diagrams of the EH66 enclosure and WW66, WW66-5/220 wiper assembly. Figure 9. EH66 Enclosure Exploded Assembly Diagram Pelco Manual C411M-D (1/96) 9 NOTE: FIGURE DOES NOT REPRESENT CURRENT PUMP IN USE. Figure 10. WW66, WW66-5/220 Wiper Exploded Assembly Diagram 10 Pelco Manual C411M-D (1/96) 7.0 MECHANICAL PARTS LISTS 7.1 MECHANICAL AND ELECTRICAL PARTS LIST FOR EH66 ENCLOSURE Item No. Qty Description 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 4 1 1 2 2 2 4 8 1 1 1 1 1 1 1 1 2*, 1** 1 4 2 1 1 1 1 1 1 1 1 2 1 2 Gasket, Window Frame Gasket, Cable Entry Plate, Cable Entry Gasket, Rim Gland, UL, PG-13.5 black Nut, UL Gland, 13.5 Fastener, Lid Link Lock Gasket, Poron Camera Sled Body Weld Assy Body Weld Assy (EH66X) Glass 1/4 X 5-9/16 X 6-11/16 Screen Vent Cap Bar Vent Cap Lid Lid (EH66X) Vent Cap *, ** Frame, Window Lug, Spade 16-20AWG Heater Blanket, 1" X 17", 120VAC, 80W Filter, Fiberglass Cut Filter Screen Air Box Fan, Tube 120VAC Gasket, Closed Cell Thermostat, SC-100-A Thermostat, OA-60 Bracket, Terminal Block Bracket, Heater Strip Terminal Block, 6-pos Plate Block EH110042 EH110072 EH14231COMP EH450010000 EH470010007B EH470010008B EH550010010B EH550010030 EH55004100COMP EH661000WA EH66X1000WA EH6610051 EH664000COMP EH664001COMP EH664228COMP EH66X4228COMP EH664229COMP EH664230COMP CON52929-1** ED210048 ** EH14050COMP ** EH14051COMP ** EH14242COMP ** EH18013 ** EH5510042 ** EH5510045A ** EH5510049A ** EH664002COMP ** EH664003COMP ** TRB6-141 ** EH664104COMP ** A B C D E F G H I J K L M N O P Q R S 2*, 1** 2 10 2 6*, 8** 2 6 2*, 3** 6 4** 4 8** 8 4** 4** 12, 16** 8 8 8 Screw, 10-32 X 1.25 Pan Phil SS Screw, 10-32 X 2.00 Pan Phil SS Screw, 10-32 X 3/8 Pan Phil SS Nut, Acorn, 10-32 SS Nut, Hex, 10-32 SS Washer, Split Lock Washer Washer, Nylon Washer, Flat #10 Internal Tooth Lock Washer #10 Screw, 6-32 X 1/4 Pan Phil Screw, 6-32 X 3/8 Truss SS Screw, 6-32 X 1/2 Pan Phil Screw, 6-32 X 5/8 Pan Phil Screw, 6-32 X 3/8 Type F, Pan Phil` Nut, Hex, 6-32 Internal Tooth Lock Washer, #6 Screw, 4-40 X 3/8 Pan Phil Nut, Hex, 4-40 Internal Tooth Lock Washer ZH10-32X1.25SPS ZH10-32X2.00SPP ZH10-32X.375SPP ZH10-32NUTCA ZH10-32NUTSH ZH10LWSSL ZH200X.437X62N ZH204X436X60C ZH10LWSIS ZH6-32X.250SPP ZH6-32X.375STS ZH6-32X.500SPP ZH6-32X.625SPP ZH6-SFX/375SPP ZH6-32X.32NUTSH ZH6LWSIS ZH4-40X.375SPP ZH4-40NUTSH ZH4LWSIS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Part Number *EH66, EH66X **EH66HB ***EH66L Pelco Manual C411M-D (1/96) 11 7.2 MECHANICAL PARTS LIST FOR WW66 AND WW66-5/220 WINDOW WIPER ASSEMBLY Item No. Qty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 1 — 1 1 1 1 12 42 1 3 1 1 1 1 1 17 18 19 20 21 22 23 24 25 26 27 1 1 1 1 1 1 2 1 2 1 1 1 1 12 Description Bearing Diode Not used Switch Spacer, 1/4" Hex x .6254-40 tap Transformer Pump Tubing, Vinyl, 1/8 ID x 1/4 OD x in. Tubing, Vinyl, 1/4 ID x 3/8 OD x in. Solenoid valve Spacer Shaft, #84-9 Roller Plate Follower Arm Wiper Washer Enclosure Bracket, Wiper Motor Motor, 120 VAC (model WW66) Motor, 230 VAC (model WW66-5/220) Wiper Arm Wiper Blade Clevis Wiper Idler Arm Bearing Block Wiper Blade Tube, Spray WW66 Fitting, BARBXMNPT Lid, Enclosure Fitting, BARB, 1/4 tube x 1/8 NPT 4-position CPC pin receptacle Cable, 4-position female Bottle, cap, hanger Bottle cover Part Number 776003 DIOPT40F — SWIV3L SPA8404 TRF21162.01.0CM WW6610031 WW6610007 WW6610005 WW650010010 WW6610010 WW661006COMP WW661011COMP WW664000COMP WW664001COMP WW664017COMP WW664020COMP WW664003COMP WW664204COMP WW664005COMP WW664010COMP WW664214COMP WW664015COMP WW650010020 WW664016COMP WW6610008 CON206061-1 WIRA220036 WW6610004 WW664900COMP Pelco Manual C411M-D (1/96) 8.0 OPTIONAL ACCESSORIES FACTORY INSTALLED EHRC Relay module for low voltage control of wiper/washer and camera on/off. Requires MEH24DT control module. TI66 Thermal insulation provides increased thermal protection for enclosure and contents at extreme temperatures (for model EH66 series only). T166X Thermal insulation for model EH66X series. WD66 WD66/220 WW66 WW66-5/220 Window defroster and defogger, 120 VAC, 80 watt operation, prevents ice buildup or condensation of moisture on the window caused by temperature and humidity. Must be used with heater/ blower assembly. Same as WD66 except 230 VAC, 80 watt operation. Window wiper and washer assembly, 120 VAC operation, designed to remove moisture and dirt from the window by remote control. The washer enhances cleaning ability of wiper and has a one quart reservoir for water or antifreeze solution, which is recommended for low temperature applications. Same as WW66 except 230 VAC, 50 Hz. FIELD INSTALLED B66KIT Blower kit, 105 CFM, 13.4 watts at 60 Hz, 120 VAC, for EH66/EH66X enclosures. BK66KIT/220 Blower kit, 90 CFM, 15 watts at 50 Hz, 230 VAC, for EH66/EH66X enclosures. E624HB Heater/blower kit, 24 VAC, for Models EH66/EH66X. EHCM Cradle mount for inverted mounting of enclosure when used with PM2000/ AH2000 ceiling mount or pan and tilts. Pelco Manual C411M-D (1/96) H66KIT Heater kit, 120 VAC, for EH66/EH66X enclosures. (For 230 VAC option, wire heaters in series.) L66KIT Tamper proof lock kit. S66 Sun shroud, provides an air space between the sun shroud and the enclosure to protect the enclosure from the direct rays of the sun. Reduces internal temperature approximately 10-15° (for model EH66 only). S66X Sun shroud for model EH66X. MISCELLANEOUS EB1 Elevation block 1", required for cameras having a low optical centerline or using a large diameter lens. EB2 Elevation block 2", same as EB1, except 2" high. NOTE: Fasteners to secure mounts are not supplied. (Minimum 1/4" diameter recommended.) 9.0 SPECIFICATIONS ELECTRICAL Input Voltage: 120 VAC, 60 Hz (230 VAC optional) Electrical Connection: 6-pin terminal strip GENERAL Construction: 5052H32 aluminum Finish: Polyester powder coat Weight: EH66 — 11 lbs (4.98 kg) EH66X — 14 lbs (6.34 kg) Dimensions: See Figure 1 Cable Entry: Two adjustable 1/2" sealable glands, mounted on removable plate for ease of assembly. Latches: Link lock fasteners Window: 1/4" thick plate glass Camera Mounting: Adjustable rail/sled 13 9.1 RECOMMENDED CABLE SIZE 9.2 POWER REQUIREMENTS FOR BLOWER, HEATER, ACCESSORIES CAUTION: When a single power source is used for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge. The blower, heater and electrically powered accessories use the following wattage when in operation: The following cable sizes are the minimum recommended for use with the combination of defroster/ blower/heater/camera. Cable distances specified assume a 10% line voltage loss: Blower: 24 VAC: 120 VAC: 230 VAC: 7.2 watts (AC rectified) 13.5 watts at 60 Hz 15 watts at 50 Hz Heater: 120 VAC or 230 VAC: 24 VAC: 160 watts 75 watts Defroster Assembly: 80 watts Wiper/Washer Assembly: 95 watts Camera: Assuming 7 watts Input Voltage 22 Awg 20 Awg 18 Awg Camera (7 w) 115 220 5,852' 6,526 m 9,306' 10,377 m 14,806' 16,510 m 23,498' 26,203 m Cam/Wiper (102 w) 115 220 401' 447 m 638' 712 m 1,016' 1,133 m 1,612' 1,798 m Cam/Wiper/Def (182 w) 115 220 225' 251 m 357' 399 m 569' 635 m 903' 1,007 m Cam/Heater/Blower (177.5 w) 115 220 231' 258 m 368' 410 m 585' 652 m 929' 1,036 m Cam/Heater/Blower/Def (257.5 w) 115 220 165' 184 m 263' 294 m 419' 467 m 665' 742 m Cam/Heater/Blower/Wiper (272.5 w) 115 220 160' 179 m 255' 284 m 406' 453 m 645' 719 m Cam/Heater/Blow/Def/Wiper (352.5 w) 115 220 119' 133 m 190' 212 m 303' 337 m 480' 536 m 14 16 Awg Pelco Manual C411M-D (1/96) 10.0 WARRANTY AND RETURN INFORMATION PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard). • Three years on Camclosure ® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty. • Two years on standard motorized or fixed focal length lenses. • Two years on Legacy ®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products. • Two years on Spectra ®, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications. • Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades). • Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura ™ Series distributed network-based video products. • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months. • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes). Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise. The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned. Method of return shipment shall be the same or equal to the method by which the item was received by Pelco. RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below. If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to: Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699 If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to: Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933 This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment. Pelco Manual C411M-D (1/96) 15 ® Pelco 3500 Pelco Way, Clovis, CA 93612-5699 • (559) 292-1981 • (800) 289-9100 FAX (559) 292-3827 • (800) 289-9150 • www.pelco.com International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.) C411M-D 16 Pelco Manual C411M-D (1/96)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-702 About : uuid:a0d8dd00-bab2-11da-bc5d-000a95a25184 Producer : Acrobat Distiller 6.0 for Macintosh Keywords : Camera Site Equipment|Enclosures|Outdoor Create Date : 2005:10:21 12:04:18-07:00 Modify Date : 2006:04:04 08:26:24-07:00 Creator Tool : Adobe PageMaker 7.0 Metadata Date : 2006:04:04 08:26:24-07:00 Document ID : uuid:a99a7380-44d9-11da-8470-003065c4ae26 Instance ID : uuid:89f1b76f-c805-45ed-9bd7-1a2f72ed7be4 Format : application/pdf Description : Obsolete Creator : llinarez Title : Pelco EH66_EH66X Environmental Enclosures_manual Subject : Camera Site Equipment|Enclosures|Outdoor Page Count : 20 Author : llinarezEXIF Metadata provided by EXIF.tools