Pelican Marine Sanitation System Puv Basic Users Manual

puvbasic cf599626-7d3f-4c55-a4df-ba3829569c3a Pelican Marine Sanitation System PUV-Basic User Guide |

2015-02-06

: Pelican Pelican-Marine-Sanitation-System-Puv-Basic-Users-Manual-517826 pelican-marine-sanitation-system-puv-basic-users-manual-517826 pelican pdf

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadPelican Pelican-Marine-Sanitation-System-Puv-Basic-Users-Manual-  Pelican-marine-sanitation-system-puv-basic-users-manual
Open PDF In BrowserView PDF
Owner’s Manual
PUV-Basic
PUV-8
PUV-16
(NSF Standard 55
Class B Certified)
Congratulations. By purchasing this system, you have taken the first step in ensuring
safe drinking water. Designed using the most advanced UV technology available
today, your UV system is designed to provide you with years of trouble free
operation with minimal maintenance required.

KEY INFORMATION YOU SHOULD KNOW:
•	 A 5-micron (nominal) sediment filter must be installed upstream of (before) any UV system.
•	 This product is for indoor use only. Keep all components clean and dry.
•	 Clean the sleeve regularly for optimum performance.
•	 Not for use in salt water applications.
Date of installation: 	
Installed by: 	
Installer phone #:
Serial #:

(Found on label on side of Power Supply)
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • tf. 1.800.265.7246 (US and Canada only) • f. (+1) 519.763.5069 • t. +31 73 623 8116 (Europe only)
e-mail: info@viqua.com www.viqua.com
520240-R_RevB

Potential
Hazard

Safety Measures

UV Exposure

Never illuminate UV Lamp outside of the UV Chamber.
Never look directly at illuminated UV Lamp, even when using protective gear.
Always use protective gear, including gloves and UV safety glasses.
If accidental exposure occurs, immediately cool affected area and consult physician.

Electrical Shock

Disconnect power to system before performing any maintenance or repair.
There may be more than one source of power.

Impalement

Never perform any physical inspection, repair or maintenance on UV Chamber unless
UV chamber has been isolated and depressurized.
Never service UV Lamps, Sleeves or associated hardware until depressurization of UV
chamber has been confirmed.

Hot chamber

Allow UV Lamps, UV Chamber to cool for a minimum of 10 minutes before handling.

Cut or ingestion

Ensure the quartz sleeve or lamp is not broken, cracked or damaged in any way when
handling equipment.

Scald from water

When there is no water flow, the water in the chamber will become hot. To prevent
scalding, allow the system to cool before draining the system.

Fire

Do not store any combustible or flammable material close to the system.

Hg Exposure

The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion
of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to
clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations
and guidelines for the removal and disposal of mercury waste.

Water leak

Use proper plumbing materials to avoid potential material degradation from UV
exposure.

SAFETY INSTRUCTIONS
GROUNDING
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current
to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified
electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with
this system – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with this
system.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system
should only be connected to a properly grounded, grounding-type power supply receptacle that is protected by a Ground Fault Circuit
Interrupter (GFCI). Inspect operation of GFCI as per manufacturers suggested maintenance schedule.
EXTENSION CORDS
If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors
that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an
electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat.
Exercise caution when arranging the cord so that it will not be tripped over or pulled. Do not use damaged extension cords. Examine
extension cord before using and replace if damaged. Do not abuse extension cord. Keep extension cord away from heat and sharp
edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank
cord to pull plug from outlet. Always grasp the plug and pull to disconnect.

WARNING – Always shut-off water flow and release water pressure before servicing.

To guard against injury, basic safety precautions should be observed, including the
following:
1.	
2.	
3.	
4.	
5.	
6.	
7.	

8.	
9.	
10.	
11.	
12.	
13.	
14.	
15.	

 EAD AND FOLLOW ALL SAFETY INSTRUCTIONS.
R
DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of this system.
Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do
not attempt repairs yourself; refer to an authorized service facility.
CAUTION - Do not operate with broken or faulty parts as this may result in exposure to ultraviolet radiation. Contact supplier
for replacement parts.
Do not operate the system if it has a damaged cord or plug, or if it is malfunctioning or if it has been dropped or damaged in
any manner.
Always unplug the system, release water pressure before servicing or cleaning. Never yank cord to remove from outlet; grasp
the wall plug and pull to disconnect.
Do not use the system for other than intended use. The use of attachments not recommended or sold by the manufacturer may
cause an unsafe condition.
To prevent risk of electrical shock, connect this system only to a properly grounded, grounding-type power supply receptacle
that is protected by a Ground Fault Circuit Interrupter (GFCI). Inspect performance of GFCI as per manufacturer’s suggested
maintenance schedule. If an extension cord is used, ensure it is of a sufficient rating and accepts the plug from this system;
never use an adapter.
Visually inspect this system prior to installation. If the quartz sleeve or lamp is broken, cracked or damaged in any way, do not
use. Contact the supplier for replacement parts.
Keep all connections dry and off the ground. Do not touch plug with wet hands.
The light emitted by the lamp will cause serious eye damage and burn unprotected skin. Do not plug system into an electrical
outlet without first properly securing the lamp into the chamber. Unplug the system prior to removing the lamp from the
chamber.
If the UV system malfunctions or fails, water must be boiled prior to consumption until the UV system is operational and the
water lines have been shocked. System failure is indicated by the system’s audible and visual alarms or the absence of any
indicator light.
Intended for indoor use only. System must not be exposed to weather elements. In seasonal applications, chamber must be
drained to prevent freezing.
Installation of this system must be in accordance with local plumbing and electrical codes as well as any and all applicable
regulations and laws.
The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision
or instruction.
SAVE THESE INSTRUCTIONS.
WARNING – To prevent risk of electrical shock, connect this system only to a properly grounded, groundingtype power supply receptacle that is protected by a Ground Fault Circuit Interrupter. Pull plug before servicing
or replacing lamp. Keep all connections dry and off the ground. Do not touch plug with wet hands.
WARNING – Do not look directly at UV lamp when it is operating. The light emitted by the lamp will cause
serious eye damage and burn unprotected skin.
WARNING – Read manual before installing or servicing this system. Only authorized personnel possessing
a strong understanding of this system should attempt to replace lamp or service this system.
WARNING – Always shut-off water flow and release water pressure before servicing.

NOTE – Maximum pressure rating is 125 PSI (8.62 bar)

1

OVERVIEW

TABLE OF CONTENTS

INSTALLATION

Overview	3
	
What model do I have?	
3
	
Specifications 	
4
	Components	
5
	
Dimensions and layout	
7
Installation	9
	
Installing the UV system	
9
	
Disinfecting the water lines	
11
Operation	14
	
Control panel 	
14
	Troubleshooting	
15

WARRANTY

MAINTENANCE

OPERATION

Maintenance	16
	
Sleeve cleaning and lamp replacement	
17
	
Warranty	20

2

D

3.

SERIAL NUMBER "000001" IS AN EXAMPLE OF THE FIRST SERIAL NUMBER OF THIS TYPE OF SYST
NUMBER WILL INCREASE FOR EACH ADDITIONAL SYSTEM PRODUCED. LABEL VISION WILL
AUTOMATICALLY INCREASE THIS NUMBER BY 1 FOR EACH LABEL PRINTED.

4.

OVERVIEW

INFORMATION IS PRINTED ON THE LABEL BY A THERMAL TRANSFER PROCESS USING A ZEBRA
PRINTER AND LABEL VISION SOFTWARE. EXACT LOCATION OF TEXT AND IMAGES
WHAT MODEL DO TRANSFER
I HAVE?
DEFINED.
APPROXIMATE POSITIONING AS PER THE BELOW IMAGE IS ACCEPTABLE. EXACT F
NOT DEFINED. APPROXIMATED FONT TYPES, SIZE, WIDTH, AND SPACING AS PER THE BELOW
ACCEPTABLE.
To find out what model you have,
look at the label on the side of the power supply.
5.

"XXXXX" IS THE LAST 5 DIGIT OF TROJAN SYSTEM PART NUMBER, AND "Y" IS CHECK SUM WHIC
AUTOMATICALLY GENERATED BY THE LABEL VISION SOFTWARE.

4.50
3.250

1.250

1.750

REPLACEMENT LAMP: "C"
602805
602805
LAMPE DE RECHANGE: "C"
DATE OF MANUFACTURE:

UV STERILIZER

3.00

98HA

Model PUV-Basic, Class B certified

Example label of model PUV-Basic

MAX

TM

MODEL: "A"

OPERATION

B

120-240
VAC, 50-60Hz, 1A
100
1.2A
SERIAL #: 000001
PART #: "B"

"SYSTEM DESCRIPTION"

1.250

SERIAL #: 00000
PART #: "B"

120-240 VAC, 50-60Hz, 1A
DATE OF MANUFACTURE:
UV STERILIZER

7 24084 XXXXX

98HA

SEE NOTE 5

"UL" OR "CE"
SEE DESIGN TABLE
(2 PL'S)

MAINTENANCE

Model PUV-8 and PUV-16
PUV-8

PUV-16

No-tools maintenance

Yes

Yes

Yes

Safety cap & special lamp
plug

Yes

Yes

Yes

Lamp operation indicator

Yes

Yes

Yes

Power supply operation
indicator

Yes

Yes

Yes

Reference card

Yes

Yes

Yes

Lamp timer display

--

Yes

Yes

Lamp timer reset button

--

Yes

Yes

Mute button

--

Yes

Yes

Solenoid valve

--

Optional

Optional

External control relay

--

Optional

Optional

6

5

4

WARRANTY

PUV-Basic

A

120-240VAC, 50-60Hz, 1A

"SYSTEM
DESCRIPTION"
Pelican
PUV-Basic
120v 3/4NPT
VIQUA - a Trojan Technologies Company
425 Clair Road West,
Guelph, ON N1L 1R1 Canada
t. 519 763 1032
t.f. 1 800 265 7246
www.viqua.com

SERIAL #: 000001

TM

MAX
MODEL : "A"

INSTALLATION

MODEL: PUV-Basic
"A"

"SYSTEM DESCRIPTION"

C

3

OVERVIEW

SPECIFICATIONS
General (All Models)

INSTALLATION

Operating Parameters
Maximum operating pressure

125 PSI (862 kPa)

Minimum operating pressure

4 PSI (27.5 kPa)

Maximum ambient air temperature

122 0F (500C)

Minimum ambient air temperature

320F (00C)

Maximum humidity

100%

Maximum hardness

120 ppm
(7 grains per gallon)

Maximum iron

0.3 ppm

Minimum UVT

70%

Installation

Vertical or horizontal*

Flow Restrictor

Yes

NSF Certification

NSF Standard 55
Class B

Rated service life of lamp

1 year

OPERATION

Certification (other)

PUV-Basic

PUV-8

PUV-16

8.9 gpm
(33.7 lpm)

15.8 gpm
(59.8 lpm)

100-240V AC

100-240V AC

Flow Rates
Rated flow for NSF Std 55, 8.9 gpm
(33.7 lpm)
Class B
Electrical

MAINTENANCE

Voltage

100-240V AC

Frequency

50-60 Hz

50-60 Hz

50-60 Hz

Max. current

0.5 Amp

0.5 Amp

0.85 Amp

Max. power
consumption

50 Watts

50 Watts

83 Watts

Lamp power

40 Watts

40 Watts

70 Watts

UV Chamber Material

304 SST

304 SST

316 SST

Inlet/Outlet

3/4" NPT

3/4" NPT

1" NPT

WARRANTY

Other

4

OVERVIEW

COMPONENTS
For replacement components please contact your installer or contact VIQUA directly for a referral:
1 800 265 7246 (North America), 519 763 1032, or info@viqua.com.

1

Part
Number

Part

2

Power supply mounting
bracket

All

2

Reference card

All

603069

3

Power supply
(includes Power supply
mounting bracket,
Reference card, Safety
cap, Lamp cord)

PUV-Basic
PUV-8,
PUV-16

650713-006
650713-007

4

Power cord

All

602636 (120V)
602637 (230V)

Junction box (optional)

PUV-8,

650705

5

--

OPERATION

1

3

INSTALLATION

Components - P
 UV-Basic, PUV-8, PUV-16

PUV-16

6

Safety cap

All

7

Lamp cord

All

603000
--

4

MAINTENANCE

6
5
7

WARRANTY
5

OVERVIEW

Components - All Models
Part

Model

Lamp
(includes O-rings)

PUV-Basic,
PUV-8
PUV-16

602805

8

O-ring

All

--

9

Sleeve bolt

All

602665

Sleeve
(includes O-rings)

PUV-Basic
PUV-8

602732

PUV-16

602733

7

7

INSTALLATION

10

8
9

OPERATION
14

12

15
11

13

WARRANTY

MAINTENANCE

16

13

6

602806

11

UV Chamber
(includes Chamber clamp(s),
and Ring clamp*).

All	

--

12

Ring clamp

All

--

13

Chamber clamp(s)

All

--

14

Solenoid valve kit
(optional)
(includes Junction Box)

PUV-8
(3/4")

650717-001

PUV-16

650717-002

15

CoolTouch valve
(optional)

PUV-8,
PUV-16

650537

16

Flow Restrictor

PUV-Basic
PUV-8
PUV-16

440267-R

8

10

Part Number

440268-R

OUTLET
A

Clearance for
lamp removal

B

OVERVIEW

DIMENSIONS AND LAYOUT

D
L

13
48” (122cm)

14

C

12

9

8

INSTALLATION

10

11

To Drain

L

16

7

OPERATION

Ø
3
4

INLET

1

2

L

Ø

6

A

B

C

(max.)

MAINTENANCE

Model

5

D

(max.)

20.5"
(52cm)

4"
(10cm)

72"
(183cm)

8.5"
(22cm)

6"
(15cm)

54"
(137cm)

PUV-8

20.5"
(52 cm)

4"
(10cm)

72"
(183cm)

8.5"
(22cm)

6"
(15cm)

54"
(137cm)

PUV-16

30"
(76cm)

4"
(10cm)

72"
(183cm)

8.5"
(22cm)

6"
(15cm)

54"
(137cm)

WARRANTY

WARRANTY

PUV-Basic

7

OVERVIEW

1

Sample valve: Allows for sampling of raw water.

2

Shut-off valve: Required to allow maintenance of pre-treatment equipment.

3

Pre-treatment (illustrative only): For the UV system to operate effectively, the water should meet certain
water quality parameters, as outlined below. To meet these, pre-treatment of the water may be required. Pretreatment equipment must be installed BEFORE the UV chamber. Pre-treatment systems can be comprised of
one or more of the following elements: sediment filters; carbon filters; iron removal systems; water softeners;
cyst reduction filters, etc.

INSTALLATION

	
	
	
	
	

Water Quality
Iron:		
Hardness:	
% UVT:	
Tannins:	

Requirements:
< .3 PPM (.3 mg/L)
< 120 PPM (7 Grains Per Gallon)
> 75%
< 0.1 PPM

Bypass shut-off valve: Bypass line and valve are optional. Intended to provide emergency water supply in the
event that the UV system is unavailable.

5

Shut-off valve: Required to allow maintenance of UV system.

6

Sample valve: Allows for sampling of water entering UV chamber; necessary in order to confirm water being
treated is of adequate quality.

7

UV chamber: Provides disinfection of the water. Must install Plus model chambers vertically.

8

CoolTouch

9

Flow Restrictor: Restricts water from flowing over the maximum NSF certified flow rate ensuring an adequate
UV dose is maintained.

10

Sample valve: Allows for sampling of water immediately following UV treatment; necessary in order to
confirm proper operation of UV system.

11

Solenoid valve: Optional piece of equipment supplied by VIQUA for PUV-8 and PUV-16 models. Must be used
with a junction box. Allows water supply to be shut-off when proper purification cannot be
assured.

TM

valve: Drains water from the chamber that’s been warmed by the lamp during periods of no flow.

WARRANTY

Shut-off valve: Required to allow maintenance of UV system.

13

Junction box: An optional piece of equipment for PUV-8 and PUV-16 models. Powers solenoid valves, remote
alarms and auto-dialers.

14

Power supply: Powers and controls the UV lamp and other devices. Provides human interface, displaying
information and allowing control inputs (such as muting the audible alarm).
Power source: Provides power to the power supply. For safety reasons the outlet must be protected by a
Ground Fault Circuit Interrupter (GFCI). NOTE: to protect the power supply, a UL1449 certified
(or equivalent) transient voltage surge suppressor is required.

WARRANTY

12

15

8

NANCE

Note: If the ground from your electrical panel is tied to your copper water lines, and
you are using a solenoid valve, installation of an approved ground strap is required. This
ground strap will maintain continuity between the lines that have been cut to install the
solenoid. Check your local electrical code for the correct clamp and cable size.

MAINTE-

MAINTENANCE

4

OPERATION

OPERATION

IMPORTANT:
A 5 micron (nominal) sediment filter must be installed
before the UV system and after any water softening equipment

6

Slide power
supply onto
mounting
bracket.

2

Screw chamber clamp(s) to the wall (#10
screws recommended.)

7

Slide
Reference
card behind
power
supply.

3

Insert chamber and
tighten clamp(s).

8

4

Make all necessary plumbing
connections referring to Dimensions and
Layout drawing.

9

OPERATION

Determine appropriate indoor location of
the power supply and chamber, referring
to Dimensions and Layout drawing.
Power supply should be installed higher
than chamber away from all water
sources. Ensure adequate clearance
above chamber to allow for removal of
the lamp and sleeve.

1

MAINTENANCE

Install power supply mounting bracket to
wall using four #8 screws (not provided).

Insert Lamp/
sleeve assembly
and screw into
chamber.

2

Caution: Over
tightening will
break the sleeve.

Safety cap, lamp plug and power supply
figures will look slightly different than
those on your system.

5

INSTALLATION

1

OVERVIEW

INSTALLING THE UV SYSTEM

10

WARRANTY

Align connections
by rotating
ring clamp (if
equipped) to
push lamp plug
onto end of lamp.
ring
clamp

9

OVERVIEW

Attach ground (green/yellow) and strain
relief (red) wires from the lamp plug to
the ground lug on the chamber. Secure
both wires with locking screw provided.

INSTALLATION

11

14

15

Outlet must be
protected by a
Ground Fault
Circuit Interrupter
(GFCI).

Let water flow to one faucet or other
water outlet, then close the outlet and
check for leaks.

Proceed to Disinfecting The Water Lines.
Locking
screw

OPERATION

12

MAINTENANCE

13

Ground
lug

Push safety
cap into
place.

Flow direction
must be the same
as arrows on the
flow restrictor

WARRANTY

Flow restrictor

10

Ground and
strain relief
wires

OVERVIEW

DISINFECTING THE WATER LINES
UV systems disinfect the water using ultraviolet light, treating the water as it passes through the
system. When there is a risk that water downstream of the UV system has been contaminated, it is
critical that these water lines be chemically disinfected. Disinfection of the water lines is therefore
required after initial system installation and following any period of time during which the system is
inoperative, whether due to an alarm condition, a power failure, or for any other reason. Make sure
the UV system is on during the entire disinfecting process.

2

Make sure power supply is plugged in for
entire disinfection process.

INSTALLATION

1

4

5

OPERATION

B LE AC

H

(sodium hypochlorite)

3

6

MAINTENANCE

7

WARRANTY
11

OVERVIEW
INSTALLATION

8

Allow water to fill
UV chamber.

9

12

Go to a water outlet and allow the cold
water to flow until you can smell bleach,
then stop the flow. Allow hot water (if
present) to flow until you can smell bleach,
then stop the flow. Repeat procedure at
all water outlets. Remember to include all
faucets, washing machines, toilets, outside
taps, and other water outlets. Note: You will
likely run out of bleach; if you cannot smell
bleach at a given outlet, turn off the main
water supply, depressurize and add more
bleach to the filter housing.

13

14

MAINTENANCE

OPERATION

10

11

WARRANTY

15

12

Let the bleach sit in the water lines for at
least four hours.

20

Flush all water outlets until bleach can no
longer be smelled (at least 5 minutes).

INSTALLATION

17

OVERVIEW

16

21

OPERATION

18

MAINTENANCE

19

WARRANTY
13

OVERVIEW

CONTROL PANEL

2

A

3

B

C

INSTALLATION

1

Buttons and Display

OPERATION

For all models.
A

Lamp timer
display

Counts down from 365 days to show time for annual lamp replacement.

B

Lamp timer
reset

After installing a new lamp, press and hold for five seconds to reset Lamp timer to
365.

C

Mute

Press to silence audible alarm.
When the alarm is due to the lamp's age, the mute button will silence the audible
alarm for 7 days; this may be repeated up to a maximum of 4 times. After that, the
button will silence for only 24 hours.

MAINTENANCE

When the alarm is due to any other issue, the mute button will silence the audible
alarm for 24 hours.

Indicator lights
Indicator lights only indicate a problem with the component when flashing red.

1

Green

Yellow*

Flashing red

Lamp operating normally

Warning; lamp will require Lamp disconnected; unplug system,
replacement shortly
reconnect lamp and plug-in system again

Solid red
Lamp inactive due to power
supply failure

Lamp failure; replace lamp

2

Power supply operating
normally

Air temperature around
system is too warm

Power supply failure; replace power
supply

WARRANTY

* Yellow indicator lights are a function of PUV-8 and PUV-16 models only.

14

Power supply inactive due
to lamp failure

OVERVIEW

TROUBLESHOOTING
The table below is a list of possible causes and solutions. Before replacing parts, please contact VIQUA
Technical Assistance for any new troubleshooting techniques : 1-800-265-7246

Possible cause

Possible solution

No power

GFCI and/or breaker tripped

Reset GFCI and/or breaker

Transient voltage surge suppressor (TVSS)
damaged

Replace TVSS

Power supply damaged

Replace power supply and use a TVSS

Connection between lamp and lamp plug
is wet

Clean and dry lamp pins and lamp plug,
check unit for leaks or condensation

GFCI or breaker
repeatedly trips

Short-circuit in the electrical assembly

Replace power supply

Leak at inlet or outlet

Threaded pipe fittings are leaking

Clean threads, reseal with Teflon tape and
retighten

Leak detected from
area of UV chamber

Condensation of moist air on cold chamber
(slow accumulation)

Control humidity or relocate unit

INSTALLATION

Symptom

O-ring damaged, deteriorated or incorrectly Inspect and replace if deteriorated
installed
Lamp/sleeve assembly not properly installed
(too tight or not tight enough)

System is operating
but water tests
reveal bacterial
contamination

See Control Panel section
Equipment downstream of UV system is
acting as a breeding ground for pathogens
Pathogens are residing in the distribution
lines post-UV
Recontamination from pipe dead-ends

Lamp timer does not
read anything

See Control Panel section

OPERATION

Alarm

Tighten assembly hand-tight

Ensure UV is the last piece of treatment
equipment
Ensure all distribution lines have been
disinfected with chlorine - see Disinfecting
the Water Lines section
Remove any pipe dead-ends and flush with
chlorine - see Disinfecting the Water Lines
section
Plug unit into AC power outlet

No power at AC power outlet

Replace fuse or reset breaker

Power cord is damaged

Replace power cord

Power surge caused damage to electrical
assembly

Replace power supply and use a surge
protector

MAINTENANCE

Unit is unplugged

WARRANTY
15

OVERVIEW

SLEEVE CLEANING & LAMP REPLACEMENT
Sleeve cleaning
Minerals in the water slowly form a coating on the sleeve. This coating must be removed because it
reduces the amount of UV light reaching the water, thereby reducing purification performance.
Basic models: please clean the sleeve regularly (3-4 times per year, or more often depending on
water quality).

INSTALLATION

When only cleaning is required, follow instructions and re-install the current lamp.
Lamp replacement
The amount of UV light created by the lamp decreases over time, requiring that the lamp be replaced
every 12 months. NOTE: The UV system is designed to operate continuously and should not be shut
off for short periods of time, such as over a period of less than three weeks.
PUV-Basic Model: Please keep track of your lamp's life. After 12 months follow these instructions to
replace system with a new lamp.

OPERATION

PUV-8 and PUV-16 Models : The system will automatically notify you after 12 months to replace the
lamp. Follow these instructions.

MAINTENANCE

Equipment required:

WARRANTY

Clean cotton,
latex or plastic
gloves are
preferred.

16

Scale remover
such as vinegar
or a citrus-based
product.

Cloth must be
soft, lint-free, and
chemical-free. No
clean-wipes.

Cotton swab.
(For Plus models
only)

OVERVIEW

6

1

2
1

Open a tap downstream of the UV unit to
release pressure. Then, close this tap.

3

Strain relief
wires should
remain
connected.

8

Hold by
sleeve bolt
to remove
lamp/sleeve
assembly.

9

2

OPERATION

4

7

INSTALLATION

2

Squeeze
tabs

1

For sleeve cleaning only:

MAINTENANCE

5

Let the system cool for 10 minutes.

Skip to step 14.
Note: Sleeve must be replaced if it cannot be
completely cleaned or if it appears scratched or
cracked.

WARRANTY

For lamp or sleeve replacement:
Clean sleeve and follow steps 10-13.

17

OVERVIEW

10

13

Screw lamp into sleeve hand-tight.
Caution: Over tightening will break the
sleeve.

2

1

2

INSTALLATION

Lamp
tab
1
Sleeve
bolt

OPERATION

11

14

Make sure lamp/sleeve
assembly is centered.
Caution: Over tightening
will break the sleeve.

1
2

Remove o-rings
and sleeve bolt
from sleeve.

15

MAINTENANCE

12

WARRANTY

Reinstall sleeve bolt
with 2 new o-rings.

18

Align
connections
by rotating
ring clamp (if
equipped) to
push lamp plug
onto end of
lamp.

ring
clamp

Push safety
cap into
place.

If lamp was replaced and you have
a PUV-8 and PUV-16 model:
Press and hold Lamp timer reset button for
5 seconds. Display should read 365.

22

Disinfect the water lines. Refer to
Disinfecting the Water Lines in Installation
section.

INSTALLATION

17

21

OVERVIEW

16

18

OPERATION

19

Check for leaks.

MAINTENANCE

20

WARRANTY
19

OVERVIEW

WARRANTY
Our Commitment
VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have manufactured your UV
purification system to the highest quality standards and value you as our customer. Should you need any support, or have questions about your
system, please contact our Technical Support team at 1.800.265.7246 or technicalsupport@viqua.com and we will be happy to assist you.
We sincerely hope you enjoy the benefits of clean, safe drinking water after the installation of your UVMAX® purification system.

How to Make a Warranty Claim
NOTE: To maximise the disinfection performance and reliability of your UVMAX® product, the system must be properly sized, installed and
maintained. Guidance on the necessary water quality parameters and maintenance requirements can be found in your Owner’s Manual.

INSTALLATION

In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your dealer. If you are unsure
whether an equipment problem or failure is covered by warranty, contact our Technical Support team at 1.800.265.7246 or e-mail technicalsupport@
viqua.com . Our fully trained technicians will help you troubleshoot the problem and identify a solution. Please have available the model number
(system type), the date of purchase, the name of the dealer from whom you purchased your UVMAX® product (“the source dealer”), as well as a
description of the problem you are experiencing.
To establish proof of purchase when making a warranty claim, you will either need your original invoice, or have previously completed and returned
your product registration card via mail or online.

Specific Warranty Coverage
Warranty coverage is specific to the following UVMAX® products: Models PUV-Basic, PUV-8 and PUV-16. Warranty coverage is subject to the
conditions and limitations outlined under the heading “General Conditions and Limitations” below.

Ten-Year Limited Warranty for UV Chamber

OPERATION

VIQUA warrants the UV chamber on the UVMAX® product to be free from defects in material and workmanship for a period of ten (10) years from
the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective UVMAX® UV chamber. Please return the defective
part to your dealer who will process your claim.

Three-Year Limited Warranty for Electrical and Hardware Components
VIQUA warrants the electrical (power supply) and hardware components to be free from defects in material and workmanship for a period of three
(3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty. Please
return the defective part to your dealer who will process your claim.

One-Year Limited Warranty for Lamps, Sleeves and UV Sensors
VIQUA warrants lamps, sleeves and UV sensors to be free from defects in material and workmanship for a period of one (1) year from the date of
purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty. Your dealer will process your
claim and advise whether the defective item needs to be returned for failure analysis.

MAINTENANCE

IMPORTANT NOTE: Use only genuine UVMAX® replacement lamps and sleeves in your system. Failure to do so may seriously compromise
disinfection performance and affect warranty coverage.

General Conditions and Limitations
None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections
that do not materially impair the operation of the product. The warranties do not cover products that are not installed as outlined in the applicable
Owner's Manual.
Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period applicable to the original part.
The above warranties do not include the cost of shipping and handling of returned items.
The limited warranties described above are the only warranties applicable to the UVMAX® products listed in the "Specific Warranty Coverage"
section. These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products, whether the
claim is based on contract, tort (including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether
written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any of these
products.

WARRANTY

VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products. VIQUA shall
not in any event be liable for special, incidental, indirect or consequential damages. VIQUA's liability shall, in all instances, be limited to repair or
replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period.

20

Printed in Canada. Copyright ©2014, VIQUA – a Trojan Technologies Business, Guelph, Ontario, Canada.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Create Date                     : 2014:04:28 13:30:44-04:00
Creator                         : Adobe InDesign CC (Windows)
Modify Date                     : 2014:05:15 14:00:59-04:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Instance ID                     : uuid:1170bd30-1fa3-431a-987c-2e3d12ca6d46
Original Document ID            : adobe:docid:indd:30131fc5-365a-11dd-a90a-b7eef804229d
Document ID                     : xmp.id:328ec91e-18ce-e945-bb18-96e3daafd68a
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:f6508c2c-7df8-b743-b5e1-f3d3823d5c9e
Derived From Document ID        : xmp.did:f6508c2c-7df8-b743-b5e1-f3d3823d5c9e
Derived From Original Document ID: adobe:docid:indd:30131fc5-365a-11dd-a90a-b7eef804229d
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Windows)
History Changed                 : /
History When                    : 2014:04:28 13:30:44-04:00
Metadata Date                   : 2014:05:15 14:00:59-04:00
Creator Tool                    : Adobe InDesign CC (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Postscript Name                 : Times-Roman, Univers-Condensed, UniversLTStd-Light, UniversLTStd-LightObl, UniversLTStd-Obl, UniversLTStd, UniversLTStd-Bold, UniversLTStd-BoldObl
Profile Blob                    : 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, , 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, 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, AAADcAAAAALK/kWzAAAAAHJzbmYAAANgK59JSgAAAA1lbWFuAAAAmbm+9D4AAAAAAg8VAAAAABACDwAOAQEAAAAAAh4ACgIBAAAAAAH0ABsDAQAAAAACDwAZBAEAAAAAAU4ANAUBAAAAAAH/ABAGAQAAAAACQQAPCQEAAAAAAigAGQsBAAAAAAG0ACIBAwABBAkCUAAMAgMAAQQJARgANgMDAAEECQEuACAEAwABBAkAsABoBQMAAQQJAS4AIAYDAAEECQHWAB4JAwABBAkBggAyCwMAAQQJAE8AVABGACAAMQAuADAAMgA5ADsAUABTACAAMAAwADEALgAwADAANAA7AEMAbwByAGUAIAAxAC4AMAAuADMAMwA7AG0AYQBrAGUAbwB0AGYALgBsAGkAYgAxAC4ANAAuADEANQA4ADUAMQAuADAAMgA5ADsAQQBEAEIARQA7AFUAbgBpAHYAZQByAHMATABUAFMAdABkAC0ATwBiAGxPVEYgMS4wMjk7UFMgMDAxLjAwNDtDb3JlIDEuMC4zMzttYWtlb3RmLmxpYjEuNC4xNTg1AGgAdAB0AHAAOgAvAC8AdwB3AHcALgBhAGQAbwBiAGUALgBjAG8AbQAvAHQAeQBwAGUAVQBuAGkAdgBlAHIAcwAgAEwAVAAgAFMAdABkACAANQA1AEEAZAByAGkAYQBuACAARgByAHUAdABpAGcAZQByMS4wMjk7QURCRTtVbml2ZXJzTFRTdGQtT2JsVW5pdmVycyBMVCBTdGQgNTUgT2JsaXF1ZWh0dHA6Ly93d3cuYWRvYmUuY29tL3R5cGVBZHJpYW4gRnJ1dGlnZXIASQB0AGEAbABpAGNmeWxnAAAABQAASEHQUiEtAAAAACB4dG0AAAAFAAAEGDXwCvYAAAAAeG1mZgAAAAUAAAIW35cbXAAAAAAgIG1iAAAABQAAAAD/////AAAAAHRuZm4AAAAFAAAAAP////8AAAAAIGNuZQAAAAYAAAdwarV0GQAAAAAAAP//bmVycAAAAAUAAAhapGxI9AAAAAB5YWxhAAAABQAAGghb05+/AAAAAG5yZWsAAAAFAAAAAP////8AAAAAbnJrZgAAAAUAABcQpJxT9AAAAAB5YWx3AAAABQAAAAgLU8jaAAAAACB0bWYAAAADT1RUTw==, 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, AAADiAAAAALK/kWzAAAAAHJzbmYAAAN4NNiIhwAAAA1lbWFuQAAAn6NdLR0AAAAAAjcXAAAAABACNwAOAQEAAAAAAl0ABwIBAAAAAAICABwDAQAAAAACTgAWBAEAAAAAAVAANAUBAAAAAAINABEGAQAAAAACZAAPCQEAAAAAAh4AGQsBAAAAAAG2AC4BAwABBAkBSAAIAgMAAQQJARgAOAMDAAEECQEuACIEAwABBAkAsABoBQMAAQQJAS4AIgYDAAEECQHkAB4JAwABBAkBhAAyCwMAAQQJAE8AVABGACAAMQAuADAAMgA5ADsAUABTACAAMAAwADEALgAwADAANAA7AEMAbwByAGUAIAAxAC4AMAAuADMAMwA7AG0AYQBrAGUAbwB0AGYALgBsAGkAYgAxAC4ANAAuADEANQA4ADUAMQAuADAAMgA5ADsAQQBEAEIARQA7AFUAbgBpAHYAZQByAHMATABUAFMAdABkAC0AQgBvAGwAZE9URiAxLjAyOTtQUyAwMDEuMDA0O0NvcmUgMS4wLjMzO21ha2VvdGYubGliMS40LjE1ODUAaAB0AHQAcAA6AC8ALwB3AHcAdwAuAGEAZABvAGIAZQAuAGMAbwBtAC8AdAB5AHAAZQBVAG4AaQB2AGUAcgBzACAATABUACAAUwB0AGQAIAA0ADUAIABMAGkAZwBoAHQAQQBkAHIAaQBhAG4AIABGAHIAdQB0AGkAZwBlAHIxLjAyOTtBREJFO1VuaXZlcnNMVFN0ZC1Cb2xkaHR0cDovL3d3dy5hZG9iZS5jb20vdHlwZVVuaXZlcnMgTFQgU3RkIDQ1IExpZ2h0VW5pdmVycyBMVCBTdGQgNjUgQm9sZEFkcmlhbiBGcnV0aWdlcgBmeWxnAAAABQAARlX22nrtAAAAACB4dG0AAAAFAAAEGJ70vGYAAAAAeG1mZgAAAAUAAAIW6K/JNQAAAAAgIG1iAAAABQAAAAD/////AAAAAHRuZm4AAAAFAAAAAP////8AAAAAIGNuZQAAAAYAAAdwarV0GQAAAAAAAP//bmVycAAAAAUAAAhbVpcvEwAAAAB5YWxhAAAABQAAG9BYgYc1AAAAAG5yZWsAAAAFAAAAAP////8AAAAAbnJrZgAAAAUAAB4MgVKoEAAAAAB5YWx3AAAABQAAAAgLU8jaAAAAACB0bWYAAAADT1RUTw==, 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
Page Count                      : 24
EXIF Metadata provided by EXIF.tools

Navigation menu