INSTALLATION and OPERATION INSTRUCTIONS
FLOJET Beer Pump Panels
MODEL NO.
66134-1
66134-2
66134-3
66134-4

IMPORTANT INFORMATION
This manual has been prepared to assist you in the
operation of Perlick Beer Pump Panel System.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualified service agents. For
your own protection, never return merchandise for
credit without our approval.

Table of Contents
Installing the Panel............................................... 2
Panel Diagram...................................................... 3
How to Operate the Beer Panel........................... 4
Beer Pump Diagram............................................. 5
Cleaning Diagram................................................. 6
Cleaning Instructions............................................ 7
Winterizing a System with Beer Pumps............... 7
Replacement Parts............................................... 7

We thank you for selecting a Perlick product and
assure you of our continuing interest in your
satisfaction.

8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
Form No. Z2149A
Rev. 10.11.06

Installation – Beer Pump Panels
Important Notes

■	 U
 se panel as a template to mark where holes
should be drilled on cooler wall. Beer pump
panels should not be installed with a height
of greater than 5 feet from the cooler floor. A
height greater than 5 feet will potentially cause
flow issues and require system re-balancing.
(Note: Make sure panel is level and pumps are
in the vertical position).

◆	 CAUTION: If using CO2 as a pressure supply for 	
	 pumps, pump exhaust must be vented to a well 	
	 ventilated area to avoid possible asphyxiation.
◆	
	
	
	

■	 Drill 9/64” pilot holes in cooler wall. Use fasteners 	
	 provided in installation kit to mount the beer 	
	 pump panel to the cooler wall.

◆	 Pump panels should never be installed more 	
	 than 5 (five) feet above the cooler floor. A height 	
	 in excess of 5 (five) feet causes additional
	 pressure drop between the keg and pump inlet 	
	 which may cause degassing or premature Smart 	
Coupler shut-off.

■	 Push CO2 supply line over barbed CO2 supply 	
	 inlet. (See diagram on page 3). Position clamp 	
	 over joint and tighten. Always use 3/8” I.D.
	 braided tubing for gas supply line. Gas supply line 	
should have drops going to each panel. (Never 	
	 connect supply line in a series hook-up.
	 Push beer line (from trunk housing) over barbed 	
liquid outlet on flow reversal valve. (See
	 diagram on page 3). Position clamp over
	 joint and tighten.
■	
	
	
	
	
	
	
	

Never use a single keg to supply more than one 	
beer pump. Using a single keg to supply more 	
than one pump will create flow problems, pump 	
burn out or premature Smart Coupler shut-off.

◆	
	
	
	

Beer pumps must be used in combination with 	
an empty keg sensing device. If an empty keg 	
sensing device is not used premature pump
failure will occur.

◆	 If using compressed air as pressure source to 	
	 drive pumps, pump and keg regulators need to 	
	 be seperated. Air must be clean and dry.

Push connector hose over liquid inlet on beer 	
pump flow reversal valve inlet fitting. (See
diagram on page 3). Position clamp over joint 	
and tighten. (NOTE: Connector hose should not 	
exceed 10 feet in length).
Install washer into hex nut on opposite end of 	
connector hose. Connect to top threaded fitting 	
of Perlick Smart Coupler.

■	 C
 ut a piece of CO2 tubing (red 9/16” vinyl tubing)
and push one end onto barbed CO2 outlet to
Keg Couplers (See diagram on page3). Position
clamp over joint and tighten. Push the other end
over the barbed gas inlet on the Perlick Smart
Coupler. Position clamp over joint and tighten.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2149A
Rev. 10.11.06

2

Diagram – Beer Pump Panel Diagram

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

3

Form No. Z2149A
Rev. 10.11.06

How to Operate – Beer Pump Panels
■	 A
 djust primary CO2 regulator by turning
adjusting screw counterclockwise until it turns
freely, then turn hand valve counterclockwise
on CO2 cylinder to the fully open position. Next,
turn regulator adjusting screw clockwise until
required system pressure plus an additional 15
psig is reached.

■	 C
 onnect the coupler to a regulated water supply
with pressure less than 30 psig. Note: Pump
damage may occur with pressure higher
than 30 psig.
■	 Open the water supply. Then open probe valve
on Perlick Smart coupler to the 45° position.
See figure 2. The beer pump will slowly pump
up the beer line in the trunk housing to set psig.
Note: If pump continues to run for longer than
expected, check lines for possible leaks at one
or more of the connections.
■	 Gradually increase secondary regulator
pressure to the designed system pressure to
achieve a flow rate of one gallon per minute
from the dispensing head. Note: Maximum
beer pump operating pressure is 90 psig.
■	 Open dispensing head faucet to purge air
trapped within the tubing.
■	 Check all gas and liquid line fittings and
connections for leaks.
■	 Close probe valve on Perlick Smart Coupler.
(See figure 1) and disconnect coupler from
regulated water source.
■	 Clean beer system. After cleaning and rinsing 	
	 the system, make sure the beer line is full of 	
	 cold water (beer dispensing from warm beer 	
	 lines will be poor quality).
■	 Tap fresh keg with Perlick Smart Coupler. Open
dispensing head faucet until clear beer flows.

Note: If CO2 is only being used for keg- 	
applied pressure, adjust to approximately
40 psig.
Note: If using air to drive beer pumps,
adjust the air compressor output regulator
pressure to a minimum of 15 psig. greater
than the maximum required system
pressure required to operate the beer
pumps. Maximum setting 100 psig.
■	 A
 djust secondary CO2 regulator which
supplies the keg pressure located on the
beer pump panel to the proper pressure
setting. Setting depends on beer brand and
temperature. Desired goal is to maintain the
natural carbonation in the beer. Open the shutoff valves.
■	 Ensure the Probe Valve on the Perlick Smart
Coupler is in closed position. See figure 1.
Ensure the Beer Pump Flow Reversal/Dispense
handle is in the dispense position. Adjust the
Secondary Air/ CO2 regulator located on the
beer pump panel to a minimum operating
pressure of 10 psig.

Smart Coupler Probe Valve Lever Positions

Figure 1
Closed Position

Figure 2
45° or Cleaning Position

Figure 3
Open Position

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2149A
Rev. 10.11.06

4

Diagram #2 – Beer Pump

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

5

Form No. Z2149A
Rev. 10.11.06

Diagram #3 – Cleaning Diagram

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2149A
Rev. 10.11.06

6

Cleaning Instructions
General Information

■	 W
 hen a beer system with beer pumps will be
shut down for an extended period, clean the
system thoroughly. After completing the rinsing step, prepare a mixture of 50% food grade
Glycerine and 50% water. Load the lines with
this mixture and make sure both ends of the
system are closed. Glycerine/water mixture
should remain in the lines for the duration of
the shutdown period.

■	 T
 he cleaning of beer lines with the new integral flow reversal feature incorporated into the
Perlick Beer Pump gives the line cleaner
numerous configurations for line cleaning.
Although the Perlick Beer Pump can be used
as an in-line pump for moving the solution from
the coupler to the faucet due to its capability of
working with negative lift, the following is the
recommended method for cleaning beer lines
with the Perlick Beer Pump with integral flow
reversal installed.

Replacement Parts

Cleaning Beer Lines using Smart Couplers
■	
	
	
■	

■	
	
	
	
	
■	
	
	
■	
■	

	
	
	
	
	
	
	
	
■	
■	
	
	
■	

44................... Air valve
40115.............. Regulator body
40129............. Regulator body
43553A........... Regulator repair kit
63706............. Flow reversal valve
63707............. Elbow, flow reversal, 2/bag
63708............. Fitting, tee, gas, barbed 1/4” with
		
check valve
63709.............. Fitting, elbow, gas, barbed 1/4” with
		
check valve
43817............. Beer pump, Flo-Jet, w/CO elbow
		
& tee

Disconnect Smart Coupler from beer connector 	
lines and soak Smart Couplers in cleaning
solution.
Couple the two beer connectors together using
Perlick’s double male adapter part # 186 with
beer washers.
Determine which sets of lines will be cleaned 	
together and rotate the Dispense/Reverse Flow 	
handle to the Reverse Flow position on the line 	
which fluid will be circulated from the faucet, to 	
the tap.
Remove the faucet from the line to which the 	
Beer Line Cleaner pump will be connected. Soak 	
faucets and brush clean before reinstalling.
Connect Beer Line Cleaner pump to the shank.
Follow standard beer line cleaning procedures.
Perlick recommends that the lines first be flushed
with clean warm water (Water temperature not
to exceed 100 degrees). Mix line-cleaning
solution per manufacturerís directions.
Circulate the solution thoroughly (Time for
circulation dependent on length of the system
and pump capabilities). Rinse the lines using 	
clean cold water (Ensure all line cleaning solution 	
has been removed from the lines to prevent
hazardous results).
Disconnect line-cleaning pump and reinstall beer
faucets.
Reconnect couplers to beer connector lines and 	
return Beer Pump Dispense/ Reverse Flow valve 	
to the dispense position.
Reconnect couplers to keg and open dispensing
head faucets until clear beer flows.

2

Winterizing Systems with Beer Pumps
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

7

Form No. Z2149A
Rev. 10.11.06

8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Form No. Z2149A
Rev. 10.11.06



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1.1-111
Instance ID                     : uuid:c3e47892-598c-11db-a3b2-000a9594fea0
Document ID                     : adobe:docid:indd:45132eaa-5af3-11db-aa67-a99f9634d959
Rendition Class                 : proof:pdf
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:C2FB0B3E5A0911DBBA86B647DEE85155, uuid:C10B77E65AEF11DBBAFFBB8EE2D389D8, uuid:2E200CDC5AF211DBB9A1EA53D10D30C2, uuid:54677EFE5A0411DBA1F6B7808E6A7CE4
Manifest Reference Document ID  : uuid:C2FB0B3D5A0911DBBA86B647DEE85155, uuid:C10B77E55AEF11DBBAFFBB8EE2D389D8, uuid:2E200CDB5AF211DBB9A1EA53D10D30C2, uuid:54677EFB5A0411DBA1F6B7808E6A7CE4
Create Date                     : 2006:10:11 19:58:07-05:00
Modify Date                     : 2006:10:11 19:58:25-05:00
Metadata Date                   : 2006:10:11 19:58:25-05:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10178 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS2 (4.0)
EXIF Metadata provided by EXIF.tools

Navigation menu