Philio Technology PAT02 Flood Multi Sensor User Manual

Philio Technology Corporation Flood Multi Sensor

User Manual

Flood Multisensor PAT02-A/B/C                 The flood multisensor PAT02 has flood, temperature and humidity, 3sensors function in one, based on Z-WaveTM technology.It is the  Z-WaveTM  plus product, it support the security, OTA... Thosenewest   features  of   the  Z-WaveTM  technology.  Z-WaveTM  is   a   wirelesscommunication protocol designed for home automation, specifically toremotely   control   applications   in   residential   and   light   commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.This product can be included and operated in any Z-WaveTM  networkwith other Z-WaveTM certified devices from other manufacturers and/orother applications.  All non-battery operated nodes within the networkwill act as repeaters regardless of vendor to increase reliability of thenetwork. The device adopt the Z-WaveTM  500 series chip, when your Z-WaveTMnetwork   system   is   all   made   by   Z-WaveTM  500   series   devices.   Thenetwork system will have the advantages as below.•Concurrent multi-channel support reduces external interference.•Better RF range, improve about 10 meters in indoor.•Support 100 Kbps transmit speed, speed up communication.Function Compare A/B/CFlood Temperature HumidityPAT02-A V V VPAT02-B V VPAT02-C VAdd to/Remove from Z-WaveTM NetworkThere are one tamper keys in the back side of the device, It can add,remove, reset or association from the Z-WaveTM network.In the first time, add the device into the Z-WaveTM network.  First, makesure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device.The device will auto start the NWI (Network Wide Inclusion) mode. Andit should be included in 5 seconds. You will see the LED light ON one second.Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”.  Excluding a node ID allocated by Z-WaveTM  Controller means “Remove” or “Exclusion”.1
Function DescriptionAdd1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.Remove1. Have Z-WaveTM Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the exclusion mode.Node ID has been excluded.ResetNotice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.Association1. Have Z-WaveTM Controller entered association mode.2. Pressing tamper key three times within 1.5 secondsto enter the association mode.Note: The device support 2 groups. The group 1 is for receiving the report message, like triggered event, temperature, humidity etc. The group 2 is for the light control, the device will send the “Basic Set” command to this group. And each group support 8 nodes maximum.•Failed or success in add/remove the node ID can be viewed from Z-WaveTM Controller.Notice 1: Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM network Notice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout after 30 seconds. You can press the tamper key 3 times to abort the NWI mode.Z-WaveTM NotificationAfter the device adding to the network, it will wake-up once per day indefault. When it wake-up it will broadcast the “Wake Up Notification”message   to   the   network,   and   wake-up   10   seconds   for   receive   thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.Press the tamper key once. The device will wake-up 10 seconds.Z-WaveTM Message ReportWhen the flood triggered the device will report the trigger event andalso report the battery status, temperature and humidity.In default the   device  will   using  Notification   Report  to  represent  thetrigger event, it can be changed to Sensor Binary Report by setting theconfiguration NO. 7 Bit4 to 1.* Flood Report:When the flood triggered, the device will unsolicited to send the reportto the nodes in the group 1.Notification Report (V4)Notification Type: Water Alarm (0x05)Event: Water Leak detected,  Unknown Location (0x02)2
Sensor Binary Report (V2)Sensor Type: Water (0x06)Sensor Value: 0xFFAnd after the flood trigger clear, the device will unsolicited to send thereport to the nodes in the group 1.Notification Report (V4)Notification Type: Water Alarm (0x05)Event: 0x00Sensor Binary Report (V2)Sensor Type: Water (0x06)Sensor Value: 0x00* Tamper Report:The tamper key pressed over 5 seconds. The device will into the alarmstate.   In   that   state,   if   the   tamper   key  be   released,   the   device   willunsolicited to send the report to the nodes in the group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Tampering. Product covering removed (0x03)Sensor Binary Report (V2)Sensor Type: Tamper (0x08)Sensor Value: 0xFF* Temperature Report:When   the   flood   triggered   or   the   temperature   differential   over   1Fahrenheit (in default), the device will unsolicited to send the “SensorMultilevel Report” to the nodes in the group 1.Sensor Type: Temperature (0x01)Note:   To   disable   send   temperature  report   after   the   flood   triggered,please setting the configuration N0.5 bit5 to 1.*** Temperature differential report ***This function default is enabled, to disable this function by setting theconfiguration NO.21 to 0.In the default, when the temperature is changed to plus or minus onedegree   Fahrenheit   (0.56   degree   Celsius),   the   device   will   reporttemperature information to the nodes in the group 1. The device will measure the temperature in every 10 seconds. And ifthe temperature is over 140 degree Fahrenheit (60 degree Celsius), thedevice will always report in each measurement. * Humidity Report:When the flood triggered or the humidity differential over 5 percent (indefault),   the   device   will   unsolicited   to   send   the   “Sensor   MultilevelReport” to the nodes in the group 1.Sensor Type: Humidity (0x05)Note: To disable send humidity report after the flood triggered, pleasesetting the configuration N0.6 bit6 to 1.*** Humidity differential report ***This function default is enabled, to disable this function by setting theconfiguration NO.23 to zero.Enable this functionality, the device will measure the humidity in every10 seconds. And if the humidity is changed to plus or minus the value(setting by the configuration NO.23), the device will report humidityinformation to the nodes in the group 1. * Timing Report:Beside   the   event   triggered   could   report   message,   the   device   alsosupport the timing unsolicited report of the status.•Battery level report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 10.3
•Low battery report: When the battery level is too low, every 30minutes will report once.•Temperature report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 13.•Humidity report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 14.•Flood state report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 15.Notice:  The configuration NO. 10, 13, 14 and 15 could be setting tozero to disable the auto report. And the configuration NO. 20 couldchange the tick interval, the default value is 30, if setting to 1, thatmeans the minimum auto report interval will be one minute. And pleasenotice if setting this value to zero, that means disable all of the timingreport except the low battery detection.Power Up Procedure* Battery Power CheckWhen the device power up, the device will detect the power level of thebattery immediately. If the power level is too low, the LED will continueflash about 5 seconds. Please change another new battery.* NWIWhen the device power on, the device will check is it already adding tothe network? If doesn't, it will auto start the NWI mode. The LED willflash in every second and continue 30 seconds. Until timeout or thedevice successful to inclusion by controller. The use can presses thetamper key 3 times to abort the NWI mode.* WakeWhen the device power on, the device will wake about 20 seconds. Inthis duration, the controller can communicate with the device. Normallythe device is always sleeping to save the battery energy.Over The Air (OTA) Firmware UpdateThe device support the Z-Wave firmware update via OTA.Let the controller into the firmware update mode, and then press thetamper key once to start the update.After finish the firmware download, the LED will start flash in every 0.5second. At that time, please don't remove the battery, otherwise itwill cause the firmware broken, and the device will no function.After the LED stop flash, it is recommended that the user power up thedevice.  Caution:   After   remove   the   battery,   please   wait   about   30seconds, and then re-install the battery.Security NetworkThe device support   the   security function.  When  the device includedwith a security controller, the device will auto switch to the securitymode. In the security mode, the follow commands need using SecurityCC wrapped to communicate, otherwise it will not response.COMMAND_CLASS_BATTERYCOMMAND_CLASS_NOTIFICATION_V4COMMAND_CLASS_ASSOCIATION_V2COMMAND_CLASS_CONFIGURATIONCOMMAND_CLASS_SENSOR_BINARY_V2COMMAND_CLASS_SENSOR_MULTILEVEL_V5COMMAND_CLASS_WAKE_UP_V24
Battery InstallationWhen   the   device   report   the   low   battery   message.   The   user   shouldreplace the battery to new one. The battery type is CR123A, 3.0V.The   way  to   open   the   front   cover   please   press   the   top   position,   torelease the cover.Replace the new battery and install the cover back.1. Put the front cover bottom, and press down.2. Push the front cover top. Installation1. To mount the device on the wall, you can choose using the tape,  orthe screw.2. Using the screw to fix the flood detector.5112
Z-Wave Configuration SettingsNotice: * All of the configuration, the data size is 1.* The configuration mark with star(*), means after the remove the settingstill   keep,   don't   reset   to   factory   default.   Unless   the   user   execute   the“RESET” procedure.* The reserve bit or not supported bit is allowed any value, but no effect. NO. Name Def. Valid A B C Description1Basic Set OFF Level 0All Setting the BASIC command value.When the flood trigger off(0x00), sendthe BASIC CC to the group 2.2Basic Set ON Level 0xFF All Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2.5(*)OperationModeAll 0 33 32 Operation mode. Using bit to control.0Bit0: Disable the Flood function.0Bit1: Reserve.0Bit2: Reserve.0Bit3: Setting the temperature scale.  0: Fahrenheit, 1:Celsius0Bit4: Reserve.0Bit5: Disable the temperature report after event triggered.  (1:Disable, 0:Enable)0Bit6: Reserve.0Bit7: Reserve.6(*)Mult-Sensor Function SwitchAll 0 64 64 Multisensor function switch. Using bit to control.0Bit0: Reserve.0Bit1: Reserve.0Bit2: Reserve.0Bit3: Reserve.0Bit4: Reserve.0Bit5: Reserve.6
NO. Name Def. Valid A B C Description0Bit6: Disable the humidity report afterevent triggered.  (1:Disable, 0:Enable)0Bit7: Reserve.7(*)CustomerFunctionAll 0 0 0 Customer function switch, using bit control.0Bit0: Reserve.0Bit1: Reserve.0Bit2: Reserve.0Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)0Bit4: Notification Type,          0: Using Notification Report.         1: Using Sensor Binary Report.0Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)0Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable)0  Bit7: Reserve.10Auto Report Battery Time12 0 ~127   The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.NO. Name Def. Valid A B C Description13Auto ReportTemperature Time12 0 ~127   The interval time for auto report the temperature. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.14Auto ReportHumidity Time120 ~127The interval time for auto report the humidity. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.15Auto ReportFlood Time120 ~127The interval time for auto report the flood state. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.20Auto ReportTick Interval30 0 ~0xFF   The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte21 Temperature Differential Report10 ~0x7FThe temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every 10 seconds. And when the temperature is over 140degree Fahrenheit, it will continue report.7
NO. Name Def. Valid A B C Description23Humidity Differential Report50 ~60   The humidity differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every 10 seconds. Z-Wave Supported Command ClassCOMMAND_CLASS_ZWAVEPLUS_INFO_V2COMMAND_CLASS_BATTERYCOMMAND_CLASS_NOTIFICATION_V4COMMAND_CLASS_ASSOCIATION_V2COMMAND_CLASS_CONFIGURATIONCOMMAND_CLASS_MANUFACTURER_SPECIFIC_V2COMMAND_CLASS_VERSION_V2COMMAND_CLASS_SENSOR_BINARY_V2COMMAND_CLASS_SENSOR_MULTILEVEL_V5COMMAND_CLASS_WAKE_UP_V2COMMAND_CLASS_ASSOCIATION_GRP_INFOCOMMAND_CLASS_POWERLEVELCOMMAND_CLASS_DEVICE_RESET_LOCALLYCOMMAND_CLASS_MULTI_CMDCOMMAND_CLASS_SECURITYCOMMAND_CLASS_FIRMWARE_UPDATE_MD_V2COMMAND_CLASS_MARKCOMMAND_CLASS_BASICSpecificationsPower by CR123A lithium battery.Signal (Frequency):868.40 MHz, 869.85 MHz(EU), 908.40 MHz, 916.00 MHz(US), 922~927 MHz(JP/TW),921.40 MHz, 919.80 MHz(ANZ),869.00 MHz(RU),   865.20 MHz(IN), 916.00 MHz(IL), Range: Minimum 40 meters indoor, 100 meters outdoor line of sight.Operating Temperature: -10oC ~ 40oCFor indoor use only.Specifications   subject   to   change   without   notice   due   to   continuingproduct improvement.                                                           FCC ID: RHHPAT02                                                         8
FCC Interference Statement This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits  are  designed to provide reasonable protection  against harmfulinterference in a residential installation. This equipment generates, usesand can radiate radio frequency energy and, if not installed and used inaccordance with the instructions,   may cause harmful interference toradio   communications.         However,     there   is   no   guarantee   thatinterference will not occur in a particular installation.  If this equipmentdoes cause harmful interference to radio or television reception,  whichcan be determined by turning the equipment off and on,   the user isencouraged to try to correct the interference by one of the followingmeasures:•Reorient or relocate the receiving antenna.•Increase the separation between the equipment and receiver.•Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected.•Consult   the   dealer   or   an   experienced   radio/TV   technician   forhelp.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) This device may not cause harmful interference, and(2)   This   device   must   accept   any   interference   received,   includinginterference that may cause undesired operation.  FCC Caution: Any changes or modifications not expressly approved bythe party responsible for compliance could void the user's authority tooperate this equipment.  This  transmitter  must  not   be   co-located   or  operating  in  conjunctionwith any other antenna or transmitter.WarningDo not dispose  of electrical appliances as unsorted municipal waste,use   separate   collection   facilities.   Contact   your   local   government   forinformation   regarding   the   collection   systems   available.   If   electricalappliances are disposed of in landfills or dumps, hazardous substancescan leak into the groundwater and get into the food chain, damagingyour health and well-being.When  replacing old appliances with  new once,  the retailer  is legallyobligated to take back your old appliance for disposal at least for freeof charge.9