PSP04 & PSP05 PIR Motion Sensor
Support 100 Kbps transmit speed, speed up communication.
Add to/Remove from Z-WaveTM Network
There are two tamper keys in the device, one is in the back side,
another is in the front side. Both of them can add, remove, reset or
association from Z-WaveTM network.
PSP04
In the first time, add the device into the Z-Wave TM network. First,
make sure the primary controller is in the add mode. And then power
on the device, just take out the insulation Mylar in the back side of the
device. The device will auto start the NWI (Network Wide Inclusion)
mode. And it should be included in 5 seconds. You will see the LED
light ON one second.
PSP05
The PSP04 & PSP05 has PIR motion sensor function in one, based on
Z-WaveTM technology.
It is the Z-WaveTM plus product, it support the security, OTA... Those
newest features of the Z-WaveTM technology. Z-WaveTM is a wireless
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
Notice: Including a node ID allocated by Z-WaveTM Controller means
“Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM
Controller means “Remove” or “Exclusion”.
This product can be included and operated in any Z-Wave TM network
with other Z-WaveTM certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
Function
Add
The device adopt the Z-WaveTM 500 series chip, when your Z-Wave TM
network system is all made by Z-WaveTM 500 series devices. The
network system will have the advantages as below.
•
•
Remove
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Description
1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the inclusion mode.
3. After add successful, the device will wake to
receive the setting command from Z-WaveTM
Controller about 20 seconds.
1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the exclusion mode.
Node ID has been excluded.
Reset
Association
•
default. When it wake-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
Notice: Use this procedure only in the event
that the primary controller is lost or
otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4th
pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default.
1. Have Z-WaveTM Controller entered association
mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the association mode.
Note: The device support 2 groups. The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. The group 2 is for light
control, the device will send the “Basic Set” command
to this group. And each group support 8 nodes
maximum.
If the user want to wake-up the device immediately, please remove the
front cover, and press the tamper key once. The device will wake-up 10
seconds.
Z-WaveTM Message Report
When the PIR motion triggered, the device will report the trigger event
and also report the battery status, temperature and illumination level.
In default the device will using Notification Report to represent the
trigger event, it can be changed to Sensor Binary Report by setting the
configuration NO. 7 Bit4 to 1.
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the
report to the nodes in the group 1.
Notification Report (V4)
Failed or success in add/remove the node ID can be viewed
from Z-WaveTM Controller.
Notification Type: Home Security (0x07)
Event: Motion Detection, Unknown Location (0x08)
Notice 1: Always RESET a Z-WaveTM device before trying to add it to a
Z-WaveTM network
Sensor Binary Report (V2)
Sensor Type: Motion (0x0C)
Sensor Value: 0xFF
Notice 2: When the device into NWI mode, the sensor functionality
will useless. The NWI mode will timeout after 30 seconds. You can
press the tamper key 3 times to abort the NWI mode.
Caution 1: Enable this functionality, it will cause the PIR Motion to
disable detection when the temperature measurement. In other words,
The PIR motion will blind one second in every one minute.
Z-WaveTM Notification
After the device adding to the network, it will wake-up once per day in
device successful to inclusion by controller. The use can presses the
tamper key 3 times to abort the NWI mode.
* Timing Report:
Beside the event triggered could report message, the device also
support the timing unsolicited report of the status.
• Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 10.
• Low battery report: When the battery level is too low, every 30
minutes will report once.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.
Security Network
Notice: The configuration NO. 10, 11, 12 and 13 could be setting to
zero to disable the auto report. And the configuration NO. 20 could
change the tick interval, the default value is 30, if setting to 1, that
means the minimum auto report interval will be one minute. And please
notice if setting this value to zero, that means disable all of the timing
report except the low battery detection.
The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
CC wrapped to communicate, otherwise it will not response.
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_WAKE_UP_V2
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* PIR Warm Up
When the device power on, the PIR need to warm up before the
operation. The warm up time about 1 minute, the LED will flash in
every 2 seconds. After finish the procedure the LED will light ON three
times.
Operation Mode
* NWI
When the device power on, the device will check is it already adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in every second and continue 30 seconds. Until timeout or the
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. But in the “Test
Mode” the LED also will light ON one second.
There are two modes “Test” and “Normal”.
“Test Mode” is for the user test the sensor function when installation.
“Normal Mode” for the normal operation.
When the event triggered, the device will report the messages to the
nodes in the group 1. The messages also include the battery level, the
temperature and the illumination level. The user can switch the report
by setting the configuration NO. 5 bit4 (illumination) and bit5
(temperature), and the configuration NO. 7 bit6 (battery).
Choosing a Suitable Location
1. The recommended mounting height is 160cm
2. Don't let the device facing the window or the sunlight.
3. Don't let the device facing the source of heat. For instance the
heater or the air-condition.
When the event triggered, if the environment luminance is less than
the setting of the value of the configuration NO. 4, the device will emit
the signal to turn ON the lighting equipment, those nodes are in the
group 2. And delay a while to turn OFF the lighting equipment. The
delay time is setting by the configuration NO. 9.
Installation
1. In the first time, add the device into the Z-Wave TM network. First,
make sure the primary controller is in the inclusion mode. And then
power on the device, just take out the insulation Mylar in the back side
of the device. The device will auto start the NWI (Network Wide
Inclusion) mode. And it should be included in 5 seconds. You will see
the LED light ON one second.
The PIR motion re-detected interval, in the “Test Mode” fixed to 6
seconds. In the “Normal Mode”, it according to the setting of the
configuration NO. 8.
Notice: When the tamper key of the back side is released, the device
always in the “Test Mode”, no matter the DIP switch setting.
2. Let the controller associate with the device into the first group, any
light switch that intend to be turned on when the device trig please
associate with the device into the second group.
Battery Installation
3. In the accessory pack. There are two type of double coated tape,
one is thicker (hereinafter referred to as A tape) and another is thinner
(hereinafter referred to as B tape), you can use A tape for the test at
the beginning. The right way for A tape installation is stick it to the
position below tamper key. The thicker tape won't let the tamper key
pressed, so the sensor will enter the test mode, You may test if
installed position is good or not by this way.
When the device report the low battery message. The user should
replace the battery to new one. The battery type is CR123A, 3.0V.
The way to open the front cover please follow below steps.
1. Using a tool to press the 1-1 position, to release the cover.
2. Hold the front cover and pull back
3. Hold the front cover and pull up
After finish the test and decide to fix, then you can remove tape A, and
mounting the sensor by using tape B. The tamper key will pressed and
let the sensor enter normal mode.
Replace the new battery and install the cover back.
1. Put the front cover bottom to 1-1, and press down.
2. Push the front cover top to 2-1.
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting
still keep, don't reset to factory default. Unless the user execute the
“RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect.
NO
Name
Basic Set
Level
3 PIR
(*) Sensitivity
4 Light
Threshold
Def.
0xFF
80
99
Vali
All
0~
99
0~
100
B C



NO
Description
Name
Setting the BASIC command value to
turn on the light. The 0xFF(-1) means
turn on the light. For dimmer
equipment 1 to 100 means the light
strength.
0 means turn off the light.
Caution: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
Def.
Vali
All
5 Operation
(*) Mode
Setting the illumination threshold to
turn on the light. When the event
triggered and the environment
illumination lower then the threshold,
the device will turn on the light.
0 means turn off illumination detected
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination
detected function. And always turn on
the light.
Description
B C
Operation mode. Using bit to control.
Caution: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
   Bit0: Reserve.
PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected
long distance, but if there is more
noise signal in the environment, it will
re-trigger too frequency.
Bit1: 1 means test mode,
0 means normal mode.
Notice:
This bit only effect by the DIP Switch
setting to “customer mode”, otherwise
it decides by DIP Switch setting to
Test or Normal Mode.

Disable the door/window
   Bit2:
function. (1:Disable, 0:Enable)
Setting the temperature scale.
   Bit3:
0: Fahrenheit, 1:Celsius
   after event triggered.
   after event triggered.
   Bit6: Reserve.
   into test mode.
Bit4: Disable the illumination report
(1:Disable,
0:Enable)
Bit5: Disable the temperature report
(1:Disable,
0:Enable)
Bit7: Disable the back key release
Notice: In none test mode, only the
value in 1 to 99 will enable the
illumination detected function and
update the illumination value.
(1:Disable,
0:Enable)
7 Customer
(*) Function
All
Customer function switch, using bit
control.
Caution: The value is unsigned byte,
NO
Name
Def.
Vali
NO
Description
B C
Name
Def.
Vali
B C
the range is from 0x00 ~ 0xFF.
received the trigger signal too
frequently. Also can save the battery
energy.
Notice: If this value bigger than the
configuration setting NO. 9. There is a
period after the light turned off and
the PIR not start detecting.
   Bit0: Reserve.

Bit1: Enable sending motion OFF
report. (0:Disable, 1:Enable)
Note: Depends on the Bit4,
0: Report Notification CC,
Type: 0x07, Event: 0xFE
1: Sensor Binary Report,
Type: 0x0C, Value: 0x00
Turn Off
9 Light
Time
Bit2: Enable PIR super sensitivity
mode. (0:Disable, 1:Enable)

   after door closed. (1:Disable,
0~
127

After turn on the lighting, setting the
delay time to turn off the lighting
when the PIR motion is not detected.
8 seconds per tick, default tick is 4 (32
seconds).
0 means never send turn off light
command.

The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time
can setting by the configuration No.20.
Bit3: Disable send out BASIC OFF
0:Enable)
Auto
Report
10
Battery
Time
Bit4: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.

   (1:Disable, 0:Enable)
   when the device triggered. (1:Disable,
Bit5: Disable Multi CC in auto report.
20
0:Enable)
8 PIR ReDetect
Interval
Time
1~
127
12
0~
127
   The interval time for auto report each
30
Bit6: Disable to report battery state
Description
   Bit7: Reserve.
   In the normal mode, after the PIR
motion detected, setting the re-detect
time. 8 seconds per tick, default tick is
3 (24 seconds).
Setting the suitable value to prevent
Auto Report
Tick
Interval
0~
0xFF
tick. Setting this configuration will
effect configuration No.10, No.11,
No.12 and No.13.
The unit is 1 minute.
Caution1: Setting to 0 means turn
off all auto report function.
Caution2: The value is unsigned
byte, the range is from 0x00 ~ 0xFF.
For indoor use only.
Z-Wave Supported Command Class
Specifications subject to change without notice due to continuing
product improvement.
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_MULTI_CMD
COMMAND_CLASS_SECURITY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
FCC ID: RHHPSP05
Disposal
This marking indicates that this product should not be
disposed with other household wastes throughout the EU.
To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the
return and collection systems or contact the retailer where
the product was purchased. They can take this product for
environmental safe recycling.
Company of License Holder:Philio Technology Corporation
Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang
Dist., New Taipei City 24257, Taiwan(R.O.C)
Specifications
Power by CR123A lithium battery.
Signal (Frequency):
PSP04 & PSP05: 868.40 MHz, 869.85 MHz(EU),
PSP04 & PSP05: 908.40 MHz, 916.00 MHz(US),(Canada)
PSP04 & PSP05: 922~927 MHz(JP/TW),
PSP04 & PSP05: 921.40 MHz, 919.80 MHz(ANZ),
RF Maximum Power: +5dBm
Range:
Minimum 40 meters indoor,
100 meters outdoor line of sight.
Operating Temperature: -10oC ~ 40oC
FCC Interference Statement
Warning
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions,
may cause harmful
interference to radio communications.
However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
your health and well-being.
When replacing old appliances with new once, the retailer is legally
obligated to take back your old appliance for disposal at least for free
of charge.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to
operate this equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 9
Language                        : zh-TW
Creator                         : Writer
Producer                        : LibreOffice 5.0
Create Date                     : 2016:06:22 15:44:44+08:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RHHPSP05

Navigation menu