Philips Lighting North America LFC8400 WIRELESS AREA CONTROLLER User Manual

Philips Lighting North America Corporation WIRELESS AREA CONTROLLER

User Manual

CE declaration Example       <Marketing provided Philips II Format example – is required in the commercial version, not required for UL submission>                                                                                            WARNING  Do not connect DyNet or Ethernet to mains.      DyNet and Ethernet networks are SELV / Class 2 and they must be isolated and segregated from mains and other wiring and installed per local wiring rules. This is a Class 2 device and must only be connected to Class 2 wiring. Use Class 2 approved power supplies only. To reduce the risk of fire or electric shock and to avoid damage to the unit, before installation or servicing, disconnect network & device power at circuit breakers or remove fuses.  Qualified licensed installers shall perform this installation only.  Do not expose this device to rain or moisture. In the installations where RS485 is used, connect the cable shield to the provided shield termination on a device connection port.RS485 cable shield must  be earthed by terminating the to the nearest grounding conductor of the supply branch circuit. Installation, programming and maintenance must be carried out by qualified personnel.                   LFC8400 “Envision” Wireless Area Controller    Installation Guide Electrical diagram …………………………………………………………………………………………………………………….... Installation  We recommend that you read carefully these instructions prior to installation.   Installation must be done in accordance to the local wiring code.  Installation of the home and building automation and control system shall comply with HD60364-4-41 where applicable. Check Connections Check and tighten all screw connections prior to energizing the device.  Power Sources This device supports any of the following three power sources: -  Ethernet PoE IEEE802.3at Type 2 -  Commercial grade 12/24Vdc Class 2 / SELV power supply -  12/24Vdc from DyNet network This device should only be operated from the types of supply specified.   Mounting Location Install in a dry, well-ventilated indoor location away from the sources of heat and electrical (RF) interference. It is recommended not to install within 3 meters (10 feet) distance from any Wi-Fi access point/ router or any other RF transmitting device operating in the 2.4GHz band. Keep away from large metallic objects and do not install in metal enclosures as they may affect the communication range. Ensure the distance to the nearest device on the same RF network is not exceeding 10 meters (30 feet).  Data Cable Use approved CAT5/6 cables only. For RS485 DyNet (where required) use screened stranded STP RS485 data cable with three twisted pairs. Segregate from mains / Class 2 cables by 300mm minimum or as per the local wiring code. Connect RS485 DyNet devices in a ‘daisy chain’. Do not cut or terminate energized data cables. In the installations with RS485 DyNet port used, shield terminal must be earthed on at least 1 point on the network per EIA485 requirements by terminating to the nearest grounding conductor of the supply branch circuit.    Special Programming Once powered and terminated correctly this device will operate in a pre-determined configuration. This device is commissioned using Philips Dynalite’s EnvisionProject PC software.  General Description  The Philips Envision Wireless Area Controller provides the essential device to integrate wireless ZigBee Luminaires and Wireless UI (UID8450, UID8451 UID8460 or UID8461) in a Connected Lighting installation.  The Wireless ZigBee Luminaires can have an integrated presence and daylight sensor.   The maximum number of Luminaires and or wireless devices (Wireless UI’s) which can be linked to a single Envision Wireless Area Controller is 50. Next to these Luminaires a maximum of 25 Luminaire based sensors can be linked.  There is no limitation of number of Envision Wireless Area Controllers in a connecting lighting network.  Simple Installation – Product can be mounted straight to any flat surface using screw tabs, mounting plate or be mounted directly to DIN Rail.
                                   Network connection  EWAC Rev F.docx. Specifications subject to change without notice. Philips Dynalite manufactured by WMGD Pty Ltd (ABN 33 097 246 921) Unit 6, 691 Gardeners Road, Mascot NSW 2020 Australia  Tel: +61 2 8338 9899 Fax: +61 2 8338 9333 Email: dynalite.info@philips.com  Web: http://philips.com/dynalite         Product specifications: Supply options:       Communication Ports Supported Ethernet Protocols Supported ZigBee protocols Input / Output Terminals    User Controls Compliance Operating Environment Transport and Storage Conditions Construction Dimensions Weight   Option 1: PoE, IEEE 802.3at Class 0 Type 2, 37-57Vdc, 8W max   Option 2: Commercial grade Power Supply 12/24Vdc SELV/Class 2, 100mA max plus DyNet load @12Vdc / 60mA max plus DyNet load @24Vdc  Option 3: from DyNet network:  100mA max@12Vdc  / 60mA max@24Vdc SELV/Class 2 Contribution to DyNet network:  max. 120mA load  @ 12Vdc (Option 1) or   voltage equal to external Power Supply output  (Option 2) Allowed supply ripple (Option 2 & 3): 1Vpp max Power consumption: max.2W (excluding DyNet and ILB) 10/100BaseT Ethernet port,  RS485 DyNet serial port, ILB port, Zigbee port, Infra-RED RC5 EnvisonIP/DyNet2, TFTP, xCLIP, IPv6 ZHA/ZLO, Green Power Ethernet PoE: RJ45 External Power Supply: 2-pole 5mm pluggable header, 1 x 2.5mmsq conductor size DyNet: 6-pole 5mm pluggable header, 1 x 2.5mmsq conductor size ILB: RJ10  Service / Pairing Push Button, Multifunction status LED (RGB), RC5 IR receiver, 100/100BT status LED CE, RCM, UL, FCC, ICES -5C to  +50C ( 23F to 122F), 0-90% RH non-condensing -25C to +70 C ( -13F to 158F), 0-90% RH non-condensing Low Profile Din Rail Polycarbonate (6 unit), UL94-V0 rated H 97mm  x W 110mm  x D 39mm (pluggable terminal connectors will add 9mm to the total height) Packed weight 0.23kg       Installation steps Only qualified licensed installers shall perform this installation. Prior to commencing, ensure all power sources, power and data cables are de-energized and isolated (touch safe) 1. Ensure mains supply input for DC power supply, PoE Ethernet network and DyNet network are all de-energized before terminating. 2. Select an appropriate mounting location indoors only following recommendations from the Mounting Location section. Mount the device and power supply as required by local wiring rules. Use Philips EWAC mounting accessories as required for surface or rack installations. To mount the device on DIN rail or mounting plate, slide the two DIN clips at the bottom of the device downwards with a screwdriver. Click the device onto the rail and slide the clips back into place. This device is approved for plenum installation. 3. External PS and DyNet only:  a. Strip-off around 30 mm of cables outer insulation jacket  b. Neatly wrap the stripped area of cable with insulating tape leaving approximately 20mm of inner wires free for termination c.  External PS option only: Strip and terminate power supply Class 2 output wires to the SUPPLY IN terminals of EWAC. Ensure correct polarity.  d. Strip and terminate DyNet port wires as required. Ensure correct connection. e. Where used, AUX dry contact input wiring cable length should be less than 10m (30 feet). Use of twisted pair wires is recommended to minimize noise coupling Ensure wires are segregated and fully inserted with no exposed copper outside terminals to prevent shorts.          All Class 2 / SELV cables shall be segregated from Class 1 wiring per local wiring code.  To minimize noise coupling on long parallel cable runs, it’s recommended to provide at least 300mm (1 foot) separation between data and mains cables (except for  installations with steel conduits used). 4. Connect Ethernet, Supply and Data cables as required. 5. Energize supply and network and check for correct operation. If programming is required use a PC with EnvisionProject Software.  FCC/IC compliance statement This device complies with part 15 of the FCC rules for the United States and Industry Canada (IC) license‐exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by Philips could void the user’s authority to operate this equipment. This product is intended for commercial use only.  DÉCLARATION DE CONFORMITÉ À LA FCC/IC Ce dispositif est conforme à la partie 15 des règles de la Federal Communications Commission (FCC) des États‐Unis et d'Industrie Canada (IC) exempts de licence RSS norme(s). Son fonctionnement est assujetti aux deux conditions suivantes: (1) Ce dispositive ne doit pas provoquer de brouillage préjudiciable, et (2) il doit accepter tout brouillage reçu, y compris le brouillage pouvant entraîner un mauvais fonctionnement. Tous les changements ou modifications non expressément approuvés par Philips, sont susceptibles d’annuler le droit de l’utilisateur à se servir de cet équipement. Ce produit est exclusivement destiné à un usage commercial.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.    DyNet Network 12/24VDC Class 2 / SELV

Navigation menu