Philips Lighting LCGEN2LP Living Colors gen2 Lamp User Manual LivingColors Mini IFU

Philips Lighting Company Living Colors gen2 Lamp LivingColors Mini IFU

User Manual

Download: Philips Lighting LCGEN2LP Living Colors gen2 Lamp User Manual LivingColors Mini IFU
Mirror Download [FCC.gov]Philips Lighting LCGEN2LP Living Colors gen2 Lamp User Manual LivingColors Mini IFU
Document ID1182436
Application ID1AxpJmV/6m+46sSJZWDs8Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.93kB (199087 bits)
Date Submitted2009-10-13 00:00:00
Date Available2009-10-13 00:00:00
Creation Date2009-09-28 09:35:06
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2009-09-28 09:35:07
Document TitleLivingColors Mini IFU
Document CreatorAcrobat PDFMaker 9.0 für Word
Document Author: nly99784

LivingColors Instruction for Use
Thank you for buying Philips LivingColors!
LivingColors has been especially designed to create your own ambiance at home, through color
and light.
Using LivingColors for the first time, please read these instructions carefully and save them for
future reference. By following our guidelines, you will enjoy the full functionality of Philips
LivingColors.
Important:
- Carefully remove the parts from the packaging.
- Check whether all parts are available.
Getting started:
1. Open the battery compartment of the remote control by sliding the button at the back.
Insert 3 AAA batteries (+ and – as indicated) (drawing a).
2. Place LivingColors at a selected location on a flat and stable surface.
Direct LivingColors towards the wall (the optimal distance is 20 inch), insert the
connection plug into the lamp (drawing b), and then plug it into the wall socket.
LivingColors will show a short introduction of the color possibilities.
3. Switch on LivingColors by briefly pressing the “I” (on) on the on/off button placed on the
remote control (drawing c).
4. Create your own ambiance by:
Touching the desired color on the color wheel. You can move your finger over the color
wheel to refine the color (drawing d)
Changing the color saturation (adding more white to the current color). Press on (logo
saturation up) for a deep color or on (logo saturation down) for a more pastel color
(drawing a). Ultimately you will reach the white color.
Dimming. Increase (logo dim up) or decrease (logo dim down) the light intensity via the
dimming buttons (drawing f).
5. Switch off LivingColors by pressing the “0” (off) button briefly. LivingColors will remember
your last color setting for your next usage (drawing c).
Do more with LivingColors:
1. Automatic color-changing mode
Sweep your finger around the color wheel (one full circle) and briefly press on “I” (“On”);
LivingColors will then turn into the automatic color-changing mode: the lamp will start changing
colors automatically.
You can adjust the speed with which colors change. Speed can be adjusted clockwise, from fast
(dark blue color on the color wheel) to slow (purple) (drawing g). You can tap anywhere on the
color wheel. While in the automatic color changing mode, you can also adjust the saturation and
brightness of the colors.
To switch back to static color mode, sweep around the color wheel again, then press “0”.
Alternatively, you can switch LivingColors off “0” and on “I” again. (drawing a)
2. Linking LivingColors lamps
1. You can operate multiple LivingColors with one remote control. The LivingColors lamps will
then project the same color (or will change colors simultaneously). In order to link several
LivingColors to one remote control, bring the remote close to the Philips logo on the top of the
lamp and press on “I” (“On”). LivingColors will flash 3 times, and then shortly flash in green color.
You can release the button now. The linked lamps will turn to the last setting of the remote
control.
- Repeat this operation for each LivingColors lamp that you want to link with the others.
- To use the LivingColors separately again, link it to another remote control in the same way as
described above.
2. It is also possible to control one LivingColors lamp with several remote controls. In order to do
so, first reset one of the remotes by pressing and holding the “0” and the (icon brightness down)
buttons simultaneously for 5 seconds. Then hold two remote controls close to each other and
press the “I” button on both for 7 seconds. You can now link the new remote control to the
LivingColors in the same way as described above.
- LivingColors that are linked to two (or more) remote controls can be controlled by either remote
control.
- To unlink a remote control from a LivingColors, hold the remote control close to the LivingColors
and press “0” for three seconds. The LivingColors will flash 3 times. Hold the “0” button a little
longer and it will slowly fade to off. The remote control and the LivingColors are now unlinked.
3. Compatibility with timers
You can use LivingColors with a timer (not included). When switched on with a timer, the
LivingColors will show your last setting (static color or automatic color-changing mode)
Fault tracing:
Problem
LivingColors is not
providing light
LivingColors does not
respond to the remote
control
Possible cause
The lamp is not plugged
in correctly
Remote control is not
working
Remote control is not
working
Remote control is not
linked to the lamp
Heavy traffic on a
wireless data network
(e.g. wireless router)
Solution
Check connections of the cord to the lamp
Check if the plug is correctly placed in the wall
socket
See the following section
Check the batteries in the remote control. The
batteries should be rightly placed (+ and -)
and should be loaded. If the remote control is
still not working, try replacing the batteries.
Link the remote to the LivingColors lamp by
following the procedure under “2. Linking
LivingColors lamps”
Move LivingColors away from the wireless
access point
Make sure that all LivingColors connected to
this remote are on; otherwise they will not
respond after this action.
Press simultaneously on “0” and (icon
saturation up) for at least 5 seconds to switch
to another channel (all LivingColors will flash
green to confirm). You can repeat this
procedure up to 3 times, preferrably from
another position.
I cannot link multiple
LivingColors lamps
“I” button wasn’t pressed
long enough
The LivingColors lamps
belong to different
versions
I cannot start the
automatic color changing
mode
LivingColors is still not
working up to standards
The sweep movement
was not correct
Other problem
Redo the procedure under “2. Linking
LivingColors lamps”. If it was linked
successfully, the lamp will give 1 green flash;
if the linking was unsuccessful it will revert to
its previous settings immediately without
flashing green.
Check if the lamps you cannot link both have
a “G2” sign on the back of the remote control
and at the bottom of the lamp itself. If one of
the lamps does not have it, it cannot be linked
with another lamp that does (but it can still be
linked with other lamps that do not have the
G2 sign).
If color changes to another (static) color, but
no color loop starts, then your sweep
movement was not correct; please try again
Contact the Philips Lighting Contact center
(see Warranty and Service)
Cleaning and maintenance:
Remove the plug from the wall socket.
To avoid scratching, the LivingColors lamp, remote control and adaptor should only be cleaned
with a soft dry cloth.
Do not use cleaning agents.
Safety instructions:
Keep the plug and LivingColors away from liquids and humidity.
LivingColors is for indoor use only. Do not use in wet locations, e.g. bathrooms or
outdoors.
LivingColors is not a toy designed to be played with by children.
Do not place on hot surfaces
For safety reasons and under the terms of the warranty, the LivingColors and plug must
not be opened.
Only use the adaptor supplied: using a different adaptor can damage your LivingColors.
Environment:
If you discard the appliance in due course, dispose of it in accordance with the instructions of the
local authority. Remove the batteries when you discard the remote control. Do not throw the
batteries away with normal household waste. They must be handed in at an official collection
point or at a Philips Dealer, both of which will dispose of the batteries in an environmental friendly
way.
Plug specifications:
AC adapter
Model:
Input:
Output:
EADP-10EB C (EU type)
100 - 240V ~ 0.3A
50-60 Hz
18.5V
0.83 A
Power consumption of the luminaire: up to 15.4 W
Remote Control:
Batteries:
Wireless specifications:
3 x Philips Powerlife Alkaline AAA LR03, 1.5 V.
Wireless RF mode frequency band:
Wireless communications protocol:
Operating channels:
2405~2475 MHz
IEEE 802.15.4)
channels 11, 15, 20 or 25
Environmental specifications:
Temperature (operation):
Temperature (storage):
Relative humidity:
40...104 °F
-13...140 °F
5...95 % non condensing
Warranty:
Philips two years warranty is valid if the product is used in accordance with the instructions and
for its intended purpose. Claims will only be accepted on submission of the original proof of
purchase (invoice, sales slip or receipt) stating the purchase date, the name of the dealer and a
description of the product.
The Philips warranty lapses if:
- Anything has been changed, crossed out, deleted or rendered illegible on the purchase docket
or product description.
- Failures caused by damage, faulty connections or abuse.
- A defect is caused by extreme circumstances not inherent to the LivingColors, for example,
lighting, flooding, fire, incorrect use or negligence.
- The LivingColors has been opened or disassembled.
Legal notices:
This device complies with Part 15 of the FCC Rules [and with RSS-210 of Industry Canada].
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Changes or modifications made to this equipment not expressly approved by Philips may void the
FCC authorization to operate this equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm
(approx. 8 inch) between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Service:
For your information and in case of any problem, please visit the Philips website at
www.philips.com/livingcolors or contact Philips Lighting Contact Centre toll-free: 00800-PHILIPSL
or 00800-74454775

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : nly99784
Company                         : Philips
Create Date                     : 2009:09:28 09:35:06+02:00
Modify Date                     : 2009:09:28 09:35:07+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : Acrobat PDFMaker 9.0 für Word
Metadata Date                   : 2009:09:28 09:35:07+02:00
Format                          : application/pdf
Creator                         : nly99784
Title                           : LivingColors Mini IFU
Document ID                     : uuid:0a2543e0-48f2-4360-8e03-a3f8428465ae
Instance ID                     : uuid:bc7e4e24-6d0d-44a8-8e16-c51865a57117
Page Layout                     : OneColumn
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CIW-LCGEN2LP

Navigation menu