Philips Medical Systems North America WMTS-MODULE M2638A 1.4GHz WMTS ITS RADIO MODULE User Manual CPY
Philips Medical Systems North America Co. M2638A 1.4GHz WMTS ITS RADIO MODULE CPY
Contents
- 1. Users Manual Application Note
- 2. USERS MANUAL
USERS MANUAL
DOCUMENT NAME Application Note: Philips M2638A Instrument Telemetry Module (1.4 GHz / Wireless Medical Telemetry Service ”WMTS") DOCUMENT IDENTIFIER A-M4840»90130-B Notice UNCONTROLLED IN PRINTED FORM UNLESS STAMPED IN RED Document The document owner is listed below: Ownership Function Title R&D Design Engineer Printed Name Signatur [Date Juan Brea g 2 g 6//3/0J7 Document The document approver(s) is/are listed below: Approver(s) Title Name (Printed) Signature/Date Program Manager Melissa Holmes 5 I /3 g/mgw7 Rev Revision Description Date Originator B Added Dual- and Tri—Band Antennas in addition to whip 12-June~2007 Juan Brea A Release l4-March-2005 Juan Brea Application Note: M2638A Instrument Telemetry Module Document Number M4840-9OI30 Rev B Page 1 of6 1 Introduction The Module is a serial network adapter designed to be used with specialized medical devices manufactured by Philips Medical Systems (Figure 1). It enables the host medical device to wirelessly establish bi— directional communication with other remote devices using the Philips’ WMTS infrastructure, RF antenna +5 Vdc _ . 1Coaxial RF cable Serial Data : , Radio Module l Ground ¢__ Figure 1: Module Block Diagram 2 Host Interface The Module interfaces to the host though a single U0 connector (Figure 2). Via this connector the host supplies DC power, signal ground and modulating data to the radio Module. The communication between the host device and the Module is a two wire asynchronous serial interface (Table 1). an 2 4 e WMTSRadio 6 pin header AMP 7 438069-6 Figure 2: Module Interface Host Connector Application Note: M2638A Instrument Telemetry Module Document Number M4840-90130 Rev B Page 2 of6 Pin Name 1/0 Function 1 Ground First of two ground connections for the Module. 2 ITSfiTx OUT Serial data to host, 3 ITSfiRx TN Serial data from host. 4 Ground Second ofrwo ground connections for the Module. 5 +5 vdc + 5 vdc +/- 5%, Sinks 35 mA avera c, 280 mA Peak durinv radio Tx/Rx 6 Not Connected Table 1: Host Connector pin assignment 3 Serial Connection Serial Specification: The interface to the Host is a serial communication link (Table 2): 9 Flow Control: 9 Baud Rate: 9 Parity: 9 Bits: 9 Logic Levels: Tx, Rx; no hardware flow control 1 15.2 kbaud; No parity bit 8 bits of data, plus 1 Start/Stop bits TTL levels, 5 volt tolerant. Logical Zero Logical One Conditions LOW HIGH 0.1 V max lOOuA sink lTSiTx 0.55V max 24mA sink 2.9V min lOOuA load 2.3V min 24mA load ITS Rx 0.6V max 2.2V min ~ Table 2: Serial Lines, Electrical DC Characteristics Maximum User Data Rate: The maximum user data rate that the radio supports is 12 kbits/second in each direction. This maximum over the air data rate is fixed by design and cannot be modified by the user. 4 Module RF Shielding. The Module contains all necessary RF shielding. The host device does not need to provide additional shielding. Application Note: M263 8A Instrument Telemetry Module Document Number M4840—90130 Rev B Page 3 of 6 5 Module Mounting Considerations. The Module is selfecontained and can be mounted anywhere using the supplied threaded pem nuts. No special heat sinking considerations are required. There are no orientation constraints. 6 RFInput/Output,Antenna The Module is only approved for use with the antennas specified by Philips, listed here: 1. Dipole Whip Philips Part Number M4842»61300 2. Tri-Band Philips Part Number M3002-66493 3, Dual-Band Philips Part Number M8100»66490 These antennas cannot be replaced with antennas of a different type. However, antennas of equivalent type with equal or lower gain to the listed antennas can be used. The RF input and output of the Module is matched to 50 ohms. A coaxial cable brings the RF outside the metal enclosure. This cable uses a unique non standard connector manufactured by JST (JST part number AYUl-lS-12676-221). For the dipole whip, the coaxial cable connects to a JST-to»reversed-TNC adapter made by Amphenol (Amphenol part number 03l»6101)where the antenna plugs in. 7 RF Transmitter Specifications The following table summarizes general transmitter specifications (Table 3). For complete details (including details on the receiver section) refer to ES-M4840—90108: 1. Frequency ranges: Bands: 1395 - 1400 MHZ and 1427 - 1432 MHZ 2, RF Output Power 8 dBm +2/—3dB, 6.3 mW (3.2 mW to 10 mW), into Antenna load. Calibrated into 50 ohms. 3. RF Output Power control a) Transmitter chain gain shall be calibrated at time of manufacture (env temp 25+/-5deg.C). b) Over power algorithm deployed to prevent excess power and also includes temperature compensation. 4. Transceiver frequency accuracy +/—15KHZ relative to channel frequency, includes temperature compensation & aging effects. 5. Reference Frequency Calibration <42pm 6. Modulation type FSK with Root Raised Cosine filtering (1M60Q7D) Table 3: Module, Transmitter Specifications 8 Fault Conditions Over/ Under Voltage The input voltage from the DC power source to the Module must remain between the values specified in Table 1. Operating the radio Module from a voltage lower source lower than 4.75 vdc or higher than 5.25 vdc can cause the regulator section to shut down ceasing operation of the Module. Application Note: M2638A Instrument Telemetry Module Document Number M4840-90130 Rev B Page 4 of6 Excessive Signal Level on Serial Input The data input signal levels must be observed as specified in Table 2. Driving the input data line over 5 vdc can cause damage to the Module input buffers, causing interruption of data transfer, Excessive Data Rate an Serial Input The host serial communication data rate is fixed at 115.2 kbaud. Clocking data at different baud rates will result in incorrect data transfer. The maximum host/user over the RF link data rate is 12 kbps. Attempting to send data at a faster rate will result in data buffer overrun and data loss, 9 Accompanying Documentation for products incorporating the Module Products which incorporate this device will be labeled “Contains FCC ID: PQC-WMTS-MODULE”, and their accompanying documentation should prominently display the following: OPERATION OF THIS EQUIPMENT REQUIRES THE PRIOR COORDINATION WITH A FREQUENCY COORDINATOR DESIGNATED BY THE FCC FOR THE WIRELESS MEDICAL TELEMETRY SERVICE, THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE CONDITION THAT THIS DEVICE DOES NOT CAUSE HARMFUL INTERFERENCE Application Note: M2638A Instrument Telemetry Module Document Number M4840-90130 Rev B Page 5 016 10 Radio Specifications 1. Frequency ranges: Bands: 1395 - 1400 MHZ and 1427 - 1432 MHZ Channel Spacing: 1.6 MHZ, see table below . RF Output Power (into 50 ohms) 3 dBm +z/73 dB (32 tho 10 mW) 3. Frequency accuracy (relative to channel frequency +/-15 kHz, includes temperature compensation & a ing effects. 4. Modulation type FSK with Root Raised Cosine filtering (1 M60Q7D) 5. Modulation deviation (relative to channel frequency) Bit 11+288 kHz +/-25 kHz Bit O: 488 kHz +/-25 kHZ 6. Transmitter output broadband noise < -58.9 dBm in 1 MHZ band, outside channel in use. 7. Out of band spurious emission levels: S1394MHZ, 21401 MHZ 51426MHZ, Z 1433 MHZ < -41dBm in 1 MHZ bandwidth for FCC limit 8. Channel Occupied Bandwidth (as defined by power in 99% BW per FCC 47CFR Ch. 1 Subpart 2.202) S +/— 800 KHZ WMTS Channel Frequencies in the 1395 — 1400 MHZ Band Lower band edge 1395.0000 MHZ Channel 1 1395.8977 MHZ Channel 2 1397.4970 MHZ Channel 3 13990963 MHZ Upper Band Edge 1400.0000 MHZ Channel Spacing 1.6 MHZ WMTS Channel Frequencies in the 1427 —1432 MHZ Band Lower band ed e 1427.0000 MHZ Channel 4 14278979 MHZ Channel 43 (H) 14302410 MHZ Channel 5 (*) 1429.4972 MHZ Channel 6 (*) 1431.0965 MHZ Upper Band Edge 1432.0000 MHZ Note: (”‘) Not available in special geographic areas, i.e. “Carve-Out Areas" (**) Available in special geographic areas only, i.e. “Carve-Out Areas” Application Note: M2638A Instrument Telemetry Module Document Number M4840-90130 Rev B Page 6 of 6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 6 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:82cabe7d-f063-4b77-8c81-b0af2c73f890 Modify Date : 2007:06:14 10:42:10-04:00 Create Date : 2007:06:14 10:42:10-04:00 Metadata Date : 2007:06:14 10:42:10-04:00 Document ID : uuid:4c900269-7381-458a-860d-b9d7e5a641dd Format : application/pdf Title : CPY DocumentEXIF Metadata provided by EXIF.tools