Philips 85900P User Manual Eagle Eye Platinum Digital IVUS Catheters 600649.001.006 EEP Data Sheet
User Manual: Philips 85900P Eagle Eye Platinum digital IVUS catheters Philips Volcano - Eagle Eye Platinum Digital IVUS catheter85900P
Open the PDF directly: View PDF .
Page Count: 2
Choice of physicians
for intravascular
imaging*
*Millenium Research
Group, US Marketrack
internal sales data
on le
Eagle Eye Platinum
RX digital
IVUS catheter
Eagle Eye
Platinum ST
catheter
Eagle Eye
Platinum
catheter
Fast, plug-and-play
simplicity
Designed for exceptional
deliverability and ease of use
• Soft, tapered tip with lowest available
entry prole and choice of two lengths1
• GlyDx hydrophilic coating
• Long rapid exchange lumen for pushability
• Radial access appropriate; ts through all 5F guides.2
Radiopaque markers for quick,
convenient length estimation
• Three markers not oered by other IVUS catheters
• 10 mm spacing facilitates length estimation without
a pullback device or marker wire.
ChromaFlo imagingGrayscale IVUS imaging SyncVision precision
guidance
VH IVUS imaging3
Provides advanced imaging with SyncVision
© 2016 Koninklijke Philips N.V. All rights reserved.
Trademarks are the property of Koninklijke Philips
N.V. or their respective owners.
600649-001/006
Philips Volcano
3721 Valley Centre Drive, Suite 500
San Diego, CA 92130 USA
www.volcanocorp.com
1. Millenium Research Group, US Marketrack internal sales data on le
2. 0.019" entry prole, data on le; tip to transducer lengths oered include 2.5 mm and 10 mm
3. Fits through guide catheters with inner diameters as low as 0.056"; data on le at Philips Volcano
4. Safety and eectiveness of system for use in the characterization of vascular lesions and tissue types has not been established.
5. Elgendy IY et al. Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug eluting stents.
Circ Cardiovasc Interv.2016;9:e003700
6. Ahn JM, Kang SJ, Yoon SH, et al. Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients
enrolled in three randomized trials and 14 observational studies. Am J Cardiol. 2014;113:1338-1347. Hyperlink “http://www.ajconline.org/article/S0002-9149(14)00549-9/abstract”
7. Witzenbichler B, et al. Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: The ADAPT-DES study. Circulation. 2014 Jan: 129,4;463-470.
8. Singh V, Badheka AO, Arora S, et al. Comparison of in-hospital mortality, length of hospitalization, costs, and vascular complications of percutaneous coronary interventions guided
by ultrasound versus guided by angiography. Am J Cardiol. Online 18 Feb 2015.
10 mm
Imaging Plane
1 mm
10 mm 10 mm 10 mm
14 mm 2.5 mm
Distal tip and RO marker detail
IVUS is now supported by large randomized and observational
studies.5,6 It is associated with a 74% change in PCI strategy, improved
outcomes and quality metrics.5,6,7,8
PIM connector
Brachial and femoral
shaft markers
Guide wire
exit port
≤ 0.014"
(0.36 mm)
Transducer
3.5 F
Tapered tip
O.D. 0.019”
150 cm
2.9 F 3.3 F
100 cm
24 cm
GlyDx hydrophilic coating
Eagle Eye Platinum / Platinum ST
RX digital IVUS catheter
Technical specications
Minimum guide catheter Maximum guide wire Maximum eld of view Working length Frequency Ordering information
5F (I.D. ≥ .056") 0.014 20 mm 150 cm 20 MHz 85900P Platinum
85900PST Platinum ST