Philips DS560S User Manual Product Brochure System One REMstar Sleep Therapy 049bd2b508a94156a36fa77c015a19b3

User Manual: Philips DS560S Product Brochure Philips System One REMstar Sleep therapy system Philips - REMstar Auto with A-Flex Sleep therapy systemDS560S

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadPhilips DS560S  User Manual Product Brochure System One REMstar Sleep Therapy 049bd2b508a94156a36fa77c015a19b3
Open PDF In BrowserView PDF
A simple solution for
your complex patients

The market-leading servo ventilation device – System One BiPAP autoSV
Advanced – simplifies treating complex sleep-disordered breathing patients

Developed for your
most challenging patients
Complex Sleep Apnea is a combination of Obstructive
Sleep Apnea (OSA) and Central Sleep Apnea. It occurs
when a patient being treated for OSA develops Central
Sleep Apnea during the application of Continuous
Positive Airway Pressure (CPAP).
Airflow

Effort

50 percent of heart failure patients display sleepdisordered breathing in the form of Cheyne-Stokes
Respiration (CSR)4 – a periodic breathing disorder
characterized by an alternating pattern of waxing
and waning tidal volumes during periods of central
apnea or hypopnea along with deep, rapid
breathing (hyperventilation).
Airflow

Effort

BiPAP autoSV Advanced features:
• Clinically-proven Servo Ventilation algorithm
• Auto EPAP for a patient’s changing needs
• Real-time access to patient data via modems
• Improved humidity output and control
• System One resistance control
• Bi-Flex for comfort
• Encore data management and reporting
• New patient waveform reports
• 15mm tubing option
• Intuitive patient controls
• Smaller and quieter design
• Assembled in USA
• Heated tube option available

1 Morganthaler, et al. SLEEP 2006;29(9):1203-1209.
2 Artz M, et al. Effects of Dynamic Bilevel Positive Airway Pressure
Support on Central Sleep Apnea in Men with Heart Failure. Chest
2008;134:61-66.
3 Wells Fargo Securities, LLC Q3 2010 Sleep Center Survey.
4 Javaheri, T. J. et al. Sleep Apnea in 81 Ambulatory Male Patients
with Stable Heart Failure: Types and Prevalences, Consequences,
and Presentations. Circulation, 1998:97;2154-2159.

BiPAP autoSV Advanced was specifically designed to treat
these conditions and, with improved real-time access
to patient’s data, to monitor medical stability in these
complex patients. BiPAP autoSV Advanced unifies
sophisticated Philips Respironics technologies – such
as Digital Auto-Trak and the REMstar Auto titration

5 Artz M. et al.
6 Kasai, T. et al.; CIRC Heart Fail 2010;3;140-148.
The uses described in the information have not been approved or
cleared by the FDA.

algorithm – to assure that with each and every breath,
the patient is appropriately ventilated.

Allies

in Better Sleep
and Breathing

The BiPAP autoSV Advanced is
just one more way we are

working with you as Allies in
Better Sleep and Breathing.

Making the complex
simpler to manage

What if you could easily and effectively treat your most complicated sleep-disordered
breathing (SDB) patients – stay connected to them at home as their needs change,
and improve your at-home management to positively impact long-term compliance?
Up to 20 percent of your current SDB population already consists of complicated
patients that present with disease states like Complex Sleep Apneas (CSA), Central
Apneas (CA), Mixed Sleep Apneas or those who suffer with Periodic Breathing, such
as Cheyne-Stokes Respiration (CSR).1 These complicated patients could benefit from

specialized Servo-Ventilation (SV) treatment.2 A recent Sleep Center survey reports that
approximately 68 percent of these complex patients are now being treated with servo
ventilators3 and those numbers are likely to grow as older technologies are replaced.
BiPAP autoSV Advanced was specifically designed and clinically validated to give you the
peace of mind to not only treat these worrisome patients, but the ability to manage
their future needs in an effective and cost-efficient manner.

• Improved real time access to patient’s data provides doctors and
home healthcare providers with daily patient usage, compliance
and efficacy data to help assess the success of treatment.
• Clinically proven algorithms, including the innovative Auto
EPAP, continually monitor and adjust to a patient’s changing
therapy needs.
• Demonstrated Bi-Flex technology enhances patient comfort
for long-term efficacy.

Easy and efficient patient management
The BiPAP autoSV Advanced incorporates more device intelligence
so that you can make the most informed and timely decisions for
your patients. By combining the proven autoSV Advanced algorithm
with the System One platform, the BiPAP autoSV Advanced:

• Incorporates our state-of-the-art Encore patient data
management and reporting system to automatically gather
vital patient information through a secured-access website
available via any computer.

• Monitors sleep assessment parameters – including AHI, leak,
and flow limitation – to provide optimum feedback for your
most complicated patients.
• Provides detailed patient-flow waveform data, and is able
to recognize indicators beyond classic OSA symptoms.
• Provides valuable information in real time with the addition
of the modem options to simplify patient management.

The BiPAP autoSV Advanced puts timely, accurate patient information
at your fingertips, allowing you to instantly change prescriptions or
communicate as necessary. The intelligence is easily accessible and can
be collected through wireless modems for remote access, helping to
link a team of clinicians in separate locations together.

Patient comfort sits at the core of compliance

BiPAP autoSV Advanced delivers comfortable therapy through an
advanced humidification system. Our humidity-control technology
analyzes ambient temperature, relative humidity and patient flow
to provide the most comfortable therapy to the patient.

In addition, Bi-Flex pressure relief technology makes it easier and
more natural for patients who have difficulty adjusting or sustaining
therapy. This pioneering technology offers pressure relief at inhalation
and exhalation to make bi-level therapy more like natural breathing
for the patient.

Simplifying patient care
Sometimes a complex problem really can have a simple answer. Thanks to sophisticated clinically-proven technologies,
BiPAP autoSV Advanced makes patient management nearly automatic and provides optimal therapy for even your most
complicated sleep-disordered breathing cases. Here’s how BiPAP autoSV Advanced takes on some of the most common
challenges of managing your complicated patients.

BiPAP autoSV Advanced
Challenge

Solution: System One

Obstructive component
Complex cases of sleep-disordered breathing
present with varying degrees of obstructive
versus central components. Maintaining a patent
airway is vital, but oftentimes very difficult, making
for particularly challenging titrations.

Auto EPAP
• Automatically distinguishes between obstructed
and clear airway apneas
• Increases EPAP only when necessary to maintain a patent airway
• Automatic adjustment of EPAP simplifies titration and achieves
proven efficacy at the minimum pressure levels
• Adapts pressure to your patients’ needs as their conditions
change (e.g., weight, alcohol use, medication, lifestyle)

Central component
In the presence of central apneas, it is
important for the patient to receive sufficient
ventilation while still allowing natural pauses in
breathing. Care must be taken not to over- or
under-ventilate a patient with central apnea.

Advanced back-up rate
• Timing of the back-up breath delivery is calculated to
encourage spontaneous breathing at the patient’s own
natural rate as necessary
• Clinically-proven technology assures therapy is highly synchronous
with the patient’s spontaneous breathing
• Delivery of automatically calculated back-up breaths has
been shown to be effective on a wide variety of complicated
sleep-disordered breathing patients

Unstable breathing
Patients with more complex sleep apnea
conditions often demonstrate irregular and
unstable breathing patterns. Standard CPAP
or bi-level therapies were not designed to
treat these patients.

Servo ventilation (SV) algorithm
• Clinically-proven5 SV algorithm monitors peak flow and
changes pressure support breath by breath to stabilize the
breathing pattern
• By establishing a targeted peak flow, the SV algorithm can
rapidly normalize unstable breathing patterns with quick
adjustments of pressure support

Patient comfort and compliance
Therapy is only effective if the patient uses it
consistently. Unfortunately, exhaling against
pressure can be very difficult for many patients.

Bi-Flex technology
• Clinically-proven6 way to enhance patient comfort and compliance
• Provides pressure relief during exhalation and at the
critical transition points from exhalation to inhalation
and back to exhalation
• Makes it easier and more natural for those having difficulty
adjusting or adhering to therapy

Patient management
Complex patients’ needs may change over time.
Stay connected to them easily and efficiently.

Patient reporting
• Encore Anywhere patient compliance management system
• SleepMapper self-management system
• Patient flow waveform reports
• SD, Bluetooth or wireless modems

Philips Healthcare is part of
Royal Philips Electronics

Philips Respironics

Philips Respironics Deutschland

1010 Murry Ridge Lane

+49 8152 93 06 0

Murrysville, PA 15668
How to reach us

Philips Respironics France

www.philips.com/healthcare

Customer Service

healthcare@philips.com

+1 724 387 4000
800 345 6443 (toll free, US only)

Asia

+33 2 51 89 36 00
Philips Respironics Italy
+39 039 203 1

+49 7031 463 2254

Philips Respironics International
Headquarters

Philips Respironics Sweden

+33 1 47 28 30 82

+46 8 120 45 900

Philips Respironics Asia Pacific

Philips Respironics Switzerland

+65 6882 5282

+41 6 27 45 17 50

Philips Respironics Australia

Philips Respironics United Kingdom

North America

+61 (2) 9947 0440

+44 800 1300 845

+1 425 487 7000

1300 766 488 (toll free Australia only)

Europe, Middle East, Africa
+49 7031 463 2254
Latin America
+55 11 2125 0744

800 285 5585 (toll free, US only)

www.philips.com/respironics
Philips Respironics China
+86 400 828 6665
+86 800 828 6665

Respironics, autoSV, Auto-Trak, Bi-Flex, BiPAP, EncoreAnywhere, Flex Family, REMstar, and System One are trademarks of Respironics, Inc. and its affiliates.
All rights reserved.

Please visit www.philips.com/respironics

© 2013 Koninklijke Philips Electronics N.V.
All rights are reserved.
Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.
CAUTION: US federal law restricts these devices to sale by or on the order of a physician.
Geyer SB 3/1/13 MCI 4105456 PN 1082037



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2013:03:07 13:49:29-05:00
Creator                         : QuarkXPress(R) 9.1
Modify Date                     : 2013:03:07 14:06:32-05:00
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : QuarkXPress(R) 9.1
Metadata Date                   : 2013:03:07 14:06:32-05:00
Producer                        : QuarkXPress(R) 9.1
Format                          : application/pdf
Title                           : Layout 1
Document ID                     : uuid:2efc9144-5682-404a-ac7d-c3cb1de7ea10
Instance ID                     : uuid:0ed7da48-fcfb-4657-aae0-0175ebb4472e
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu