Next generation sensor
for Sidestream CO2
monitoring
Philips offers a high-quality Sidestream CO2
sensor and a family of disposable cannulas and
airway adapter sets for use on intubated and
non-intubated patients.
The Philips M2741A Sidestream CO2 Sensor
uses sophisticated infrared absorption
spectroscopy to measure EtCO2 and
respiration rate. The sensor delivers a clear,
precise capnogram for respiratory rates up to
150 breaths per minute. And with a sampling
rate of 50 ml/min, it is ideal for use with infants
and smaller patients.
The M2741A Sidestream CO2 Sensor is used
with Philips Capnography Measurement Server
Extension (M3014A) in combination with the
IntelliVue Multi Measurement Server.
Philips offers airway adapter sets for intubated
patients that require close monitoring of their
EtCO2 levels. Nasal and oral-nasal cannulas
are available for non-intubated patients who
undergo procedural sedation.
M2741A Sidestream CO2 Sensor Features/
Benets:
• Application Environment. Ideal for the
General Ward, ICU, CCU, ER, OR and EMS.
• Compatible. M2741A Sensor is compatible
with the entire family of IntelliVue patient
monitors (Release D.0 or later).
• Dependable. Delivers a clear, precise
measurement of EtCO2.
• Reliable. Rugged solid-state design.
• Innovative.Samplingcellandlterare
attached to the disposable sampling kits,
preventinguidsfromcontaminatingthe
sensor.
• Easy. Plug and play functionality. Intuitive and
easy to use. No regular calibration required.
M2741A Sidestream CO2 Sensor
InitializationTime Fullspecicationswithin2minutes,waveformdatainlessthan20seconds
at an ambient temperature of 25oC.
CO2 Measurement Range 0 to 150 mm Hg, 0 to 19.7%, 0 to 20kPa (at 760 mm Hg)
CO2 Accuracy 0-40 mm Hg +_ 2 mm Hg
41-70 mm Hg +_ 5% of reading
71-100 mm Hg +_ 8% of reading
101-150 mm Hg +_ 10% of reading
Note:Allspecicationsare+_ 12% for respiration rates above 80 BPM
Sample Flow Rate 50 ml/min +_ 10 ml/min
CO2 Stability ShortTermDrift:Driftoverfourhoursshallnotexceed0.8mmHgmax.
LongTermDrift:Accuracyspecicationwillbemaintainedovera120-hourperiod.
Calibration No routine user calibration required.
PhysicalCharacteristics Height:<38.1mm
Width:<66.1mm
Depth:<88.9mm
TemperatureandHumidity Operating:0to40oC, 10 to 90% RH, non-condensing
Storage:40to70oC,<90%RH,non-condensing
Water Resistant (Sensor) IPX4-Splash-proof
Shock Resistance IEC TR 60721-4-7 Class 7M3
IEC 60068-2-27 Shock
Data Output CO2 gas concentration (mm Hg), End-tidal CO2, Inspired minimum CO2, Airway
Respiratory Rate
Product Number
M2744A CO2 Nasal Cannula, Adult
M2745A CO2 Nasal Cannula, Pediatric
M2746A CO2 Nasal Cannula, Infant
M2750A CO2/O2 Nasal Cannula, Adult
M2751A CO2/O2 Nasal Cannula, Pediatric
989803144471 CO2/O2 Nasal Cannula, Infant
M2756A CO2 Oral-Nasal Cannula , Adult
M2757A CO2 Oral-Nasal Cannula , Pediatric
M2760A CO2/O2 Oral-Nasal Cannula, Adult
M2761A CO2/O2 Oral-Nasal Cannula Pediatric
Single-Patient Disposable Cannulas — Non-Intubated
All-in-onesingle-patient-usesamplecell,lterandfulllineof
adult, pediatric and infant nasal cannula sampling kits for non-
intubated patients.
Model Endotracheal Tube Size
M2768A Airway Adapter Set greater than 4.0 mm
989803144531 Airway Adapter Set equal to or less than 4.0 mm
M2772A Airway Adapter Set H greater than 4.0 mm
M2773A Airway Adapter Set H equal to or less than 4.0 mm
M2776AStraightSampleLine(non-humidied)recommendedforHMElter
M2777AStraightSampleLineH(humidied)recommendedforHMElter
Airway Adapter Sets — Intubated
Specications
All-in-one single-patient-use airway adapter kits for long- and short-term EtCO2
monitoring of intubated adult, pediatric and infant patients.
Is the patient intubated?
Short Term
Up to 12 hours
(patientnon-humidied)
Long Term
Up to 120 hours
(patienthumidied)
Yes No
Key applications:
(Operating Room, Recovery Room)
M2768A Airway Adapter Set
(ET Tube >4.0mm)
Does the patient need oxygen?
Yes No
Nasal
Up to 12 hours
Monitoring O2 / CO2
Nasal
Up to 12 hours
Monitoring O2 / CO2
Oral/Nasal
Up to 12 hours
Key applications:
(ED, EMS, Transport,
Conscious Sedation)
Key applications:
(ED, EMS, Transport,
Conscious Sedation)
Key applications:
(Sleep Lab, ED, EMS, Transport,
Conscious Sedation, Critical Care Areas)
M2750A
Adult CO2 / O2
Nasal Cannula
M2751A
Pediatric CO2 / O2
Nasal Cannula
M2760A
Adult CO2 / O2
Oral/Nasal Cannula
M2744A
Adult CO2 Nasal Cannula
M2745A
Pediatric CO2 Nasal Cannula
M2756A
Adult CO2 Oral/Nasal
Cannula
M2757A
Pediatric CO2 Oral/Nasal
Cannula
M2761A
Pediatric CO2 / O2
Oral/Nasal Cannula M2746A
Infant CO2 Nasal Cannula
Sidestream Sample Kit Selection Guide
M2772A Airway Adapter Set H
(ET Tube >4.0mm)
M2773A Airway Adapter Set H
(ET Tube =/<4.0mm)
Key applications:
(Sleep Lab, ED, EMS, Transport,
Conscious Sedation, Critical Care Areas)
Oral/Nasal
Up to 12 hours
M2776A Straight Sample Line
(recommended for Heat Moisture
Exchangerlter)
M2777A Straight Sample Line H
(recommended for Heat Moisture
Exchangerlter)
Key applications:
(Critical Care Areas, Operating Room)
989803144531 Airway Adapter Set
(ET Tube <4.0mm)
989803144471
Infant CO2 / O2
Nasal Cannula
Philips Healthcare is part of
Royal Philips Electronics
How to reach us
www.philips.com/healthcare
healthcare@philips.com
fax: +31 40 27 64 887
Asia
+852 2821 5888
Europe, Middle East, Africa
+49 7031 463 2254
Latin America
+55 11 2125 0744
North America
+1 425 487 7000
800 285 5585 (toll free, US only)
Philips Healthcare
Global Information Center
P.O. Box 1286
5602 BG Eindhoven
The Netherlands
© 2008 Koninklijke Philips Electronics N.V.
All rights are reserved.
Philips Healthcare reserves the right to make changes in specications and/or to discontinue any product at any time without notice or