Philips Ballasts For Fluorescent Lamps Users Manual
Ballasts For Fluorescent Lamps to the manual 78958096-dd0d-45c2-88eb-56e38d1ea047
2015-02-05
: Philips Philips-Ballasts-For-Fluorescent-Lamps-Users-Manual-386908 philips-ballasts-for-fluorescent-lamps-users-manual-386908 philips pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
excellent lighting begins with us www.lighting.philips.com 12 2 0 808 01S 03/2002 Printed in Hong Kong Philips Lighting Electronics Malaysia – Philips Luminaires Asia Pacific Headquarters & Maltronics Sdn Bhd Building 1, no. 8 89 Yishan Road No. 3 Jalan Perunding Shanghai 200233, China U1/17, Section 41 Tel: + 86 21 6485 5330 Hicom-Glenmarie Industrial Park Fax: + 86 21 6485 2213 40150 Shah Alam, Malaysia E-mail: kieu.huynh-dinh@philips.com Tel: + 603 7872 7272 Fax: + 603 7872 7273 Australia – Philips Lighting (Australia) Ballasts E-mail: men.sun.sim@philips.com 65 Epping Road, North Ryde Sydney, NSW 2113, Australia Pakistan – Philips Lighting Pakistan Tel: + 61 2 9947 0311 F-54, S.I.T.E. Fax: + 61 2 9947 0319 Karachi-75730, Pakistan E-mail: philip.sampson@philips.com Tel: + 92 256 0071 for fluorescent lamps Fax: + 92 256 1067 China – Philips Lighting Electronics E-mail: zubair.siddiqui@philips.com (Shanghai) Co. Ltd. Building 1, No. 8 89 Yishan Road Philippines – Philips Electronics & Lighting, Inc. Shanghai 200233, China 106 Valero St. Salcedo Village Tel: + 86 21 6485 5330 1227 Makati City, Makati City, Philippines Fax: + 86 21 6485 2213 Tel: + 63 2 810 0161 E-mail: jonathan.zhang@philips.com Fax: + 63 2 894 6280 E-mail: dennis.p.nazario@philips.com Hong Kong – Philips Electronics Hong Kong Ltd. Singapore – Philips Electronics 28th Floor, Hopewell Centre Singapore Pte Ltd. 17 Kennedy Road,Wanchai, Hong Kong 620A Lorong I Toa Payoh Singapore 319762 Tel: + 852 2821 5204 Tel: + 65 6882 3112 Fax: + 852 2876 7713 Fax: + 65 6253 2343 E-mail: alison.lee@philips.com E-mail: men.sun.sim@philips.com India – Philips India Ltd. Taiwan – Philips Lighting Taiwan Ltd. P-65 Taratolla Road 5F, 96 Sec. 1 Chien Kuo N. Road Calcutta-700 088, India Taipei,Taiwan R.O.C. Tel: + 91 33 401 3216/4245-9 Tel: + 886 2 2134 2735 Fax: + 91 33 401 4123 Fax: + 886 2 2134 2678 E-mail: c.r.datta@philips.com E-mail: calvin.wang@philips.com Indonesia – PT. Philips Ralin Electronics Thailand – Philips Electronics Gedung Philips (Thailand) Ltd. JI. Buncit Raya Kav. 99 -100 515 Moo 4, Pattana 3 Road, Jakarta 12510, Indonesia Bangpoo Industrial Estate Tel: + 62 21 7940 040 ext.4402 Preaksa Samutprakarn 10280,Thailand Fax: + 62 21 7940 050 Tel: + 66 (0)2 709 3300-29 E-mail: kelana.adisaputra@philips.com Fax: + 66 (0)2 709 3344 Japan – Philips Japan Ltd. E-mail: isara.haritaworn@philips.com + 66 (0)2 323 0775 Philips Bldg, 2F 13-37, Kohnan 2-Chome Minato-ku,Tokyo 108-8507 Japan Tel: + 81 3 3740 5156 Fax: + 81 3 3740 5163 E-mail: yuuji.yamasaki@philips.com EB-STANDARD In the Asia Pacific region mains voltage fluctuation can be a daily occurrence affecting the output of fluorescent lamps and impeding ignition. The EB-STANDARD range of electronic ballasts gives you back control over lighting conditions. The range is designed to suit the spectrum of rated mains voltages in the region – from 220-240V, 50 and/or 60Hz – and to handle mains voltage fluctuations from 216-247V without affecting performance. Additionally, the lamps will continue to operate well even if mains voltage drops to 184V Benefits or rises to 264V. Philips EB -STANDARD electronic ballasts start rapidly and operate The manufacture of the EB -STANDARD in an ISO 9001 without noise or flicker, making life better for everyone whose environment further guarantees the reliability of the electronic life they illuminate. E B -STANDARD ballasts also lighten the bottom ballast. ISO 14001 certification gives customers the peace of mind line: they use only 80% of the energy of traditional ballasts and, that comes from knowing the products they use are manufactured by preheating lamp filaments, give longer lamp life. in an environmentally responsible way. Long lamp life and long ballast lifetimes make the EB -STANDARD ideal for situations with The EB -STANDARD is designed to meet the diverse requirements frequent switches per day or where demands on the ballast are of projects and the various regional standards in Asia Pacific. heavy. The EB -STANDARD is built to meet the varied requirements It does this by complying with demanding international safety and of projects and regional standards across the Asia-Pacific region. performance standards, including compliance with the I EC 928 safety standard and I EC 929 performance standard.The versatile E B-STANDARD range works with an extensive combination of different lamp wattages. Without compromising comfort, the EB -STANDARD range of electronic ballasts optimised energy use and extends lamp Product portfolio Lamp family Wattage Quantity of lamps on one ballast ‘TL’D 18W, 36W, 58W 1, 2, 3 or 4 lamps PL-L 18W, 36W, 58W 1 or 2 lamps Energy saving calculation Step 1 Determine traditional ‘TL’D 36W, 45W System power electromagnetic system (T8+ballast+starter) Step 2 Determine new electronic system ‘TL’D 36W, 36W System power (T8+EB-S ballast) Step 3 Determine average burning hours per year 4,000 hours DESIGNED BY PHILIPS DESIGN HONG KONG 2002 (Typical office building) Step 4 Determine cost per KWH US$0.10 (Depending on local supply condition) Annual cost saving = (Step 1 - Step 2) x Step 3 x Step 4 1000 Example: Annual cost saving = (45-36) x 4000 x US$0.10* = US$3.60 1000 Savings per lamp * data subject to change and ballast lifetimes.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2002:05:14 19:05:03Z Modify Date : 2002:05:21 14:06:38+08:00 Page Count : 2 Has XFA : No Creation Date : 2002:05:14 19:05:03Z Producer : Acrobat Distiller 4.0 for Macintosh Mod Date : 2002:05:21 14:06:38+08:00 Metadata Date : 2002:05:21 14:06:38+08:00EXIF Metadata provided by EXIF.tools