Manuel
Technical Note communication systems Development Manuel Campus S FM Transmitter (TX2S) US Version Doc.: Vers.: Page: Date: TN010906.doc V1 1 of 5 06.09.01 Distribution: Montena EMC SA, CH-1728 Rossens, Mr Manfred Portman Path: Marquis:> D:/data/phonak/T_memos/Englisch/TN010906.doc Name F. Marquis F. Marquis F. Marquis Produced by Approved Released Date 06.09.01 06.09.01 06.09.01 Visum FMa FMa FMa Manuel Campus S FM Transmitter (TX2S) History: Version V1.0 Date 06.09.01 Modifications New document Pages all Technical Note communication systems Development Manuel Campus S FM Transmitter (TX2S) US Version Doc.: Vers.: Page: Date: TN010906.doc V1 2 of 5 06.09.01 Background Hearing impaired persons use hearing aids (HA), which are electroacoustic amplifiers including a microphone and an earphone and having frequency response and dynamic characteristics specific to each hearing loss. BTE (Behind-The-Ear) hearing aids have the possibility to be connected to an external microphone, by means of electrical contacts placed on the bottom of the apparatus. A wireless solution for a remote microphone still exists: an FM radio receiver is connected to the HA, via the electrical contact system for the external microphone. This FM radio receiver can be either : • In form of a little box, self powered by its own battery, and connected to the contact system by a cable (for example Microvox R), or • A new system, fully miniaturised (Phonak Microlink), having the form of a piece of sugar, powered by the hearing aid battery, an clipped on the bottom of the BTE-HA. A previous FM transmitter (Microvox TX2) is still in use for application in schools. The microphone is connected with a cable to the small transmitter having the form of a little box. The transmitter is fixed to the clothes by a clip and the microphone by a small cord around the neck or a needle to the shirt. The Campus S (TX2S) is a more convenient remote microphone for hearing impaired persons. Campus S has an integrated synthesizer which allows to change the frequency of the transmitting channel. TX2S is the development name of Campus S. Product description The Phonak Campus S is a FM transmitter (channel bandwidth of 25 kHz) for FM receivers, as the Phonak MicroLink or MicroVox, connected to hearing aid instruments. Its frequency for north america is from 216 to 217MHz. The Campus S is equipped with 2 audio inputs: • Microphone-input for speech transmission (teacher) • Audio-input for external audio source (CD-player, radio, ...) The microphone can be switched as omnidirectional or directional. The Campus S has 2 modes of operation: off and active (transmitting). The status of the Campus S is indicated with the LCD display. When in off sate, the LCD display is blank. When transmitting, the Channel number is indicated on the LCD display. It can manually be switched on and off. The Audio-input adds the left and right channels of a stereo signal to generate a mono signal. The Campus S is powered by a prismatic NimH accumulator. A DC power supply (wallcharger) is used to charge the accumulator. The Campus S is protected against polarity inversion and false voltage (too high or AC). The microphone cable is used as transmitter antenna. Technical Note communication systems Development Manuel Campus S FM Transmitter (TX2S) US Version Doc.: Vers.: Page: Date: TN010906.doc V1 3 of 5 06.09.01 Operating description Before starting, charge the accumulator of the Campus S during at least 12 hours. To do this, connect the plug of the Wall-Charger to the DC input shown on figure 1. The DC input voltage must be between 3VDC and 6 VDC. fig. 1 1. Campus S, audio and DC input Switching ON/OFF To switch the Campus S ON, press during 1 second on the "ON/OFF" button. Then the channel number will be displayed. The accumulator charge status is displayed. The Campus S is transmitting on the displayed channel. fig. 2 LCD and buttons To switch the Campus S OFF, press during 1 second on the "ON/OFF" button. The LCD display will become blank. The Campus S is in OFF state and is no more sending. Technical Note communication systems Development 2. Manuel Campus S FM Transmitter (TX2S) US Version Doc.: Vers.: Page: Date: TN010906.doc V1 4 of 5 06.09.01 Channel change To change the transmitting channel of the Campus S, press button "channel UP" or "channel DOWN" shown on fig. 3. Then the new channel number will be displayed and the Campus S is transmitting on the new channel. "Channel UP" will increment to the next available channel and "channel DOWN" will decrement to the next available channel. There are 23 channels programmed in the Campus S (see list in para 6. channel UP channel DOWN Remote Control fig. 3 3. LCD and buttons Remote Control function By pushing the "Remote Control" button, the Campus S will inductively send a command to synchronize future receivers to the same frequency. 4. External audio source An external audio source (CD player, Radio, ...) can be connected to the Campus S via the audio input Jack (3.5mm). The audio level will be adapted with an AGC circuit (Automatic Gain Control). The signal will be mixed with the signal of the MM8 microphone. The microphone can be switched OFF. Audio Input fig. 4 Campus S, audio and DC input Technical Note communication systems Development Manuel Campus S FM Transmitter (TX2S) US Version Doc.: Vers.: Page: Date: TN010906.doc V1 5 of 5 06.09.01 MM8 microphone The MM8 microphone can be set in 3 different modes by rotation of the upper part of the microphone. In fig. 5, the MM8 microphone is set in "OFF" position. In this case, only the external audio signal will be transmitted. In fig. 6, the MM8 microphone is set in "OMNI" position. In this case, the microphone has an omni-directional characteristic In fig. 7, the MM8 microphone is set in "DIR" position. In this case, the microphone has an directional characteristic fig. 5 Position "OFF" fig. 6 Frequency list of the 23 channels Position "OMNI" Phonak Channel Frequency [MHz] N01 216.0125 N02 216.0375 N04 216.0875 N05 216.1125 N08 216.1875 N09 216.2125 N12 216.2875 N13 216.3125 N16 216.3875 N17 216.4125 N18 216.4375 N61 216.5125 N62 216.5375 N64 216.5875 N65 216.6125 N68 216.6875 N69 216.7125 N72 216.7875 N73 216.8125 N76 216.8875 N77 216.9125 N79 216.9625 N80 216.9875 fig. 7 Position "DIR"
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Producer : Acrobat Distiller 4.05 for Windows Creator : Microsoft Word 8.0 Modify Date : 2001:09:17 12:36:21+02:00 Author : MARQUIS FRANCOIS Subject : Microvox RX2 Title : Design Specification Create Date : 2001:09:17 12:34:52 Page Count : 5 Page Mode : UseNoneEXIF Metadata provided by EXIF.tools