Phonak WALLP Phonak WallPilot User Manual WallPilot User Guide

Phonak Inc Phonak WallPilot WallPilot User Guide

Manual

Download: Phonak WALLP Phonak WallPilot User Manual WallPilot User Guide
Mirror Download [FCC.gov]Phonak WALLP Phonak WallPilot User Manual WallPilot User Guide
Document ID428734
Application IDOlpEAMLTMLNP2/XzakQ1+w==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize41.92kB (523963 bits)
Date Submitted2004-06-07 00:00:00
Date Available2004-06-17 00:00:00
Creation Date2004-04-01 15:15:52
Producing SoftwareAcrobat Distiller 6.0.0 for Macintosh
Document Lastmod2004-04-02 14:20:40
Document TitleWallPilot User Guide
Document Author: Phonak AG

GA 029-0171-02 GB Englisch
hearing systems
WallPilot
User Guide
TM
Contents
Page
Description
Welcome to the world of multi-frequency FM communication
Main components
Installation
Choosing the right location
Preparing for installation
Mounting to the wall
Battery replacement
Selecting the channel
Adjusting the range
Key lock
Daily use
Important notes
Phonak distributors worldwide
Service and Warranty
10
11
12
13
15
GA 029-0171-02 GB Englisch
Description
10
Main unit
Frame with built-in antenna
Antenna cable connection to main unit
(not visible on this diagram)
Power cord
On/Off switch
Channel selector (up/down)
LCD display
10
3-position coarse range adjustment
(F1/F2/F3)
Rotary control for continuous fine
range adjustment
(not visible on this diagram)
Fixation screws
Welcome to the world of multi-frequency FM
communication
Thank you for choosing the WallPilot, a fully automatic, wireless frequency
synchronizer especially developed for use with multi-frequency MicroLink receivers.
The WallPilot ensures that FM users entering a room are automatically switched to
the right channel. The process is fully automatic and completely independent of the
channel previously in use by the FM receiver. The WallPilot is ideal for schools and
other buildings where FM is used in several rooms at once.
The WallPilot is a Swiss quality product that will give many years of excellent service.
GA 029-0171-02 GB Englisch
Main components
12
13
WallPilot with integral main unit
Power cord
Audio cable for optional software programming of the main unit
Fixation screws and screw anchors for wall mounting
Hole drilling template for wall mounting
Choosing the right location
Outside of
WallPilot
range
Correct
Within
WallPilot range
Incorrect
The choice of location depends on local conditions. Please consider the following:
• The WallPilot range is continuously adjustable from zero to two meters.
• The WallPilot synchronization signal reaches any FM receiver within the set range.
For this reason, FM users who are already in the room should not remain permanently within the reception range of the WallPilot signal (see figure).
The WallPilot transmits its synchronization signal equally in all directions (360°).
The signal can pass through walls, meaning it may also be picked up by an FM
receiver outside the room.
GA 029-0171-02 GB Englisch
The WallPilot is designed for mounting to a wall. Possible locations for the unit are:
• Inside the room, adjacent to the entrance door
The WallPilot then covers the room entry zone, which is the ideal location if there is
sufficient space. However, classroom desks and other working areas must be out of
range of the WallPilot.
• In a vacant area within the room
The floor can be marked to show where people should walk past in order to receive
the WallPilot synchronization signal. This option allows reduction of the operating
range to a minimum.
• In an entry corridor
This is the recommended position when the room is at the end of a corridor, and FM
users pass through the corridor solely for classroom access.
Preparing for installation
• Determine the approximate location according to the previous criteria.
• Put the WallPilot into operation (see next section) and either hold it against the wall
or rest it on a chair (standing up, not lying flat).
• Turn the range adjustment control (see page 11) fully clockwise (max.) and set the
range switch to ‘F1’ (short range).
• Do practical tests with hearing instruments and FM receivers.
• If the range is too great:
Decrease the range as necessary using the rotary control (turn counter-clockwise)
GA 029-0171-02 GB Englisch
• If the range is too small:
Set the range switch to ‘F2’ (medium range) and again turn the rotary range control
fully clockwise.
• Keep testing until the optimum range is adjusted. Once the range is optimized, test
to ensure that the WallPilot signal does not reach FM users at undesired locations
(e.g. in the corridor outside, sitting at desks, en route to the blackboard, etc.). In
case of problems, select a different location for the WallPilot. An alternative is to
restrict the range as necessary; in this case we recommend marking the floor to
indicate the WallPilot reception area.
• After finding a good location in this way, proceed to mounting the WallPilot to
the wall.
Mounting to the wall
~5 cm (feet)
~1.1 m (feet)
•
•
•
•
Drill fixation holes using the supplied template as a guide
Insert the screw anchors
Secure the WallPilot to the wall using the supplied fixation screws
Plug the power cord into the socket marked on the main unit.
The WallPilot can operate directly using the power cord, or on rechargeable batteries
(for approx. 12 hours)
☞ Mains power is recommended for ease of use.
GA 029-0171-02 GB Englisch
Battery replacement
Push up to open lid
Remove main unit
Remove antenna cable
The WallPilot main unit includes a removable rechargeable battery. The battery and
power cord are the same types used with the Campus S.
Selecting the channel
As with the Campus S, a pair of channel selection buttons sets the FM channel.
Press one of the channel selection buttons for 2 seconds
▲ = selects a higher channel ▼ = selects a lower channel
☞ Ensure that the WallPilot is set to the designated channel for the room. This should
correspond to the channel used by the FM transmitter (e.g. the Campus S) operating
in the same room.
10
GA 029-0171-02 GB Englisch
Adjusting the range
Rotary control on the side of the main unit.
Range switch
F1 = Close range
F2 = Medium range
F3 = Long range
Re-check the range after WallPilot installation and readjust if necessary.
☞ It is recommended to check the range regularly.
11
Key lock
The WallPilot has a built-in key lock. Similar to mobile telephones, it avoids unintentionally operating the keys. When activated, the key lock also prevents tampering by
children.
To lock keys: Press both keys simultaneously for 2 seconds. A « »-symbol appears
in the LCD display.
To unlock keys: Press the same keys simultaneously for 2 seconds.
12
GA 029-0171-02 GB Englisch
Daily use
Putting into operation:
1 Switch on the WallPilot (press the On/Off button for 2 seconds)
2 Check the channel and battery charge state on the LCD
3 Activate the key lock if needed (see page 12 key lock)
13
When FM users enter the room:
The multi-frequency FM user’s receivers are set automatically to the channel selected
in the WallPilot.
Depending on how the multi-frequency MicroLink receivers are programmed, a brief
signal in the hearing instrument may indicate the change of channel.
Switching off:
• Switch off the WallPilot (press the On/Off button for 2 seconds)
If the WallPilot is operated with the rechargeable battery, simply plugging in the power
cord recharges the battery. The three battery segments in the LCD display blink to indicate charging.
14
GA 029-0171-02 GB Englisch
Important notes
1. The hearing instrument and FM receiver must be switched on before the WallPilot
can change the receiver channel.
2. Ensure that the WallPilot is properly fixed and that the power cord is safely secured.
3. Avoid simultaneous use of multiple WallPilots with overlapping transmission ranges.
4. External influences such as interference from computer monitors can reduce the
WallPilot’s operating range.
15
Phonak distributors worldwide
Group companies:
Australia
Austria
Belgium
Canada
Denmark
France
Germany
Italy
Japan
Jordan
Netherlands
New Zealand
Norway
Spain
Sweden
Switzerland
United Kingdom
USA
Independent
general agents:
Manufacturer:
(detailed information on www.phonak.com)
Phonak Australasia Pty. Ltd., Baulkham Hills N. S. W. 2153
Hansaton Akustische Geräte GmbH, 5020 Salzburg
Lapperre N.V., 1702 Groot-Bijgaarden
Phonak Canada Limited, Mississauga, Ontario L5S 1V9
Phonak Danmark A/S, Nitivej 10, 2000 Frederiksberg
Phonak France SA, 69500 Bron
Phonak GmbH, 70736 Fellbach-Oeffingen
Phonak Italia S.r.l., 20159 Milano
Phonak Japan Co., Ltd., Tokyo 101-0044
Phonak Middle East, 11181 Amman
Phonak B.V., 3439 ME Nieuwegein
Phonak New Zealand Ltd., Takapuna, Auckland 9
Phonak AS, 0105 Oslo
Phonak Laem S.A., 03008 Alicante
Phonak AB, 117 34 Stockholm
Phonak AG, Phonak Schweiz, 8712 Stäfa
Phonak UK Limited, Warrington, Cheshire WA1 1PP
Phonak Inc., Warrenville, IL 60555-3927
A complete list of Phonak distributors is available at Phonak's Internet site:
www.phonak.com. Please visit us or ask your hearingcare professional
for information.
Phonak AG, Laubisrütistrasse 28, CH-8712 Stäfa, Switzerland
GA 029-0171-02 GB Englisch
Notes
Notes
Service and Warranty
Phonak offers you a comprehensive global warranty which becomes effective on the
date of purchase. Please ask your hearingcare professional for details and duration. This
warranty covers any repairs due to defects in material and/or workmanship. The warranty
does not cover damage from improper handling or care, exposure to chemicals, immersion in water or undue stress. Damage caused by third parties or non-authorized service
centers renders the Phonak warranty null and void. This warranty does not include any
services performed by a hearingcare professional in their office. This warranty applies to
the Phonak products listed below:
Serial number:
Date of purchase:
029-0171-02/V00 0204 Printed in Switzerland © Phonak AG All rights reserved
Your hearingcare professional:

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 22
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:c467563a-fbb9-42a9-9c25-70b5aa298471
Producer                        : Acrobat Distiller 6.0.0 for Macintosh
Create Date                     : 2004:04:01 15:15:52+02:00
Modify Date                     : 2004:04:02 14:20:40+02:00
Metadata Date                   : 2004:04:02 14:20:40+02:00
Document ID                     : uuid:bc4d926c-83de-11d8-b8e2-0003930c9bdc
Format                          : application/pdf
Title                           : WallPilot User Guide
Description                     : WallPilot User Guide
Creator                         : Phonak AG
Author                          : Phonak AG
Keywords                        : 029-0171-02
Subject                         : WallPilot User Guide
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KWCWALLP

Navigation menu