Phonak WFT1 Wireless Functional Test Device (WFT) User Manual

Phonak Inc Wireless Functional Test Device (WFT)

User Manual

Download: Phonak WFT1 Wireless Functional Test Device (WFT) User Manual
Mirror Download [FCC.gov]Phonak WFT1 Wireless Functional Test Device (WFT) User Manual
Document ID2642936
Application IDi21bGgHvQjqwt67AiFp9AA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize134.34kB (1679200 bits)
Date Submitted2015-06-10 00:00:00
Date Available2015-06-10 00:00:00
Creation Date2015-05-26 15:07:40
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2015-05-26 15:08:09
Document TitleUser Manual
Document CreatorAdobe InDesign CS6 (Windows)

Work Instruction / User Guide
Wireless Functional Test Device
Version 2
000.000.015.286.pdf
Page:
1 of 15
Number of local copies:
Date of print:
Uncontrolled copy if printed
Contact:
technical.support@phonak.com
Version: 1.00
File:
Written:
2015-04-10 11bwestcott
Approved:
2015-04-20 1bkrajnovic
Released:
2015-04-21 11zbudrovic
Electrostatic discharge sensitive devices
Take ESD precautionary measures whenever handling electronic devices
Table of Contents
General Description
Wireless Functional Test Device
Wireless Functional Test Setup
Wireless Functional Test Device Self Test
Wireless Functional Test Device Test Modes
Wireless Functional Test Device Operation
Compliance Information
Information and Description of Symbols
Important Safety Information
Revision History
Workplace Ergonomics:
Health and Safety
Adjust table and chair to elbow height.
Elbow height = table
The angle between your thigh and lower leg should
be at least 90°.
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
2 / 15
General Description
The Wireless Functional Test (WFT) device is used to perform a wireless functional quality test (Go/NoGo test) of the proprietary HIBAN link (10.6
MHz) by generating an audio stream from the WFT device to a hearing instruments or compatible Digital Wireless Accessories (DWA).
WFT device interacts as a simple remote control and can be used to test remote control functionality by decreasing the volume and changing the
program of a hearing instrument.
Following platforms are supported:
•
P3: Palio 3 Platform with a new chip realizing the HiBAN 2 with 8-DPSK (DQPSK) modulation.
All hearing aids starting by Audeo V and Digital Wireless Accessories of the “II” generation.
•
P2: Palio 2 Platform with a chip realizing the HiBAN 1 with F1D / FSK modulation. All wireless hearing aids till Audeo V.
Please read this user guide carefully to benefit from all the features of the WFT.
Intended Use
The WFT device is designed for trained and certified custom product manufacturing and repair centers within Phonak and Unitron Group Companies
(GCs) and by qualified distributors.
The WFT device is used for performing a functional test of the HIBAN link of a Device Under Test (DUT).
The WFT device is not capable to program nor manipulate any setting of hearing instrument or a DWA.
The WFT does not give pass/fail output. Rating needs to be done by operator.
Wireless Functional Test
Purpose
This document is an outline of the user interface menu for the Wireless Functional Test (WFT) of the WFT device.
This test is compatible with both Palio 2 (P2) & Palio 3 (P3) hearing instruments (HI) & Palio 3 Digital Wireless Accessories (DWA).
There are different tests available for the two platforms due to the wireless processor used.
Palio 2 HI remote control test & the Palio 3 remote control test & wireless functional test for both P3 HI & P3 DWA.
The HI will always have a side designation, left or right. The WFT device is able to test the HI without the operator selecting a specific side.
The WFT device will automatically connect to a DWA under test regardless of the fitting side status, left or right, or binaural.
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
3 / 15
Power on WFT Device
Select Platform
Palio 3
Select Test Mode
Palio 2
HI Remote Control Test
Palio 3
Hearing Instrument Test
P3 HI
Remote Control Test
P3 HI Select
Test Mode
P3 HI
Wireless Functional Test
Palio 3
CROS Test
P3 CROS
Select Test Mode
P3 CROS
Remote Control Test
Palio 3
Digital Wireless Accessory Test
P3 CROS
Wireless Functional Test
P3 DWA
Remote Control Test
P3 DWA
Wireless Functional Test
Start HI Test
No
End HI Test
Platform
change needed
for next order
Yes
HI Passed Test
No
HI needs repair action.
May be kicked out to
troubleshooting
Return to Select Platform
menu for the next test
All devices
tested
Power off WFT Device
Test the next device
P3 DWA
Select Test Mode
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
4 / 15
Test Preconditions
Hearing Instruments
The HI can have either a generic or product firmware loaded.
In either FW the default settings (also called manufacturing settings) should be set.
In the default settings configuration all audio inputs (omni mic, dir mic, T’coil etc.) & all user controls are active.
The HI is set to full on gain output, therefore the volume remote control command is to decrease the HI volume.
The program change command is to toggle to the next program in a loop. Once the last program is reached the HI will change to the first program.
Digital Wireless Accessories
For the DWA remote control function to work the client settings must be used.
The remote control can be setup for a monaural or binaural fitting.
For streaming function the DWA can be in a "Generic grouping" or a fitted state.
Regardless of the fitting state of the DWA the WFT device will detect the DWA a stream the audio accordingly.
Failure Test
In the event that a HI or DWA fails the test repair actions are to be taken.
These actions are not in the scope of this document.
Functional Test
P2 & P3 HI Remote Control Test
The WFT device will send a RC command to the HI.
The operator will listen to the HI to confirm the correct function. i.e. Change Program – HI changes program.
P3 HI Wireless Functional Test
The WFT device will send a sine wave to the HI.
The operator listens to the WFT device output via a Stethoclip & judges the quality of the audio streamed to the WFT device.
P3 DWA & P3 CROS II Remote Control Test
The WFT device will receive the remote control command from the DWA or CROS II & display what the command was.
The operator will compare the displayed result to the action they performed. i.e. VC up is pressed, WFT device displays "Volume UP".
P3 DWA & P3 CROS Wireless Functional Test
The DWA or P3 CROS II streams an audio signal to the WFT device.
The operator has to judge the quality of the audio based on what he/she hears at the receiver of the WFT device.
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Menu functions
Palio 2
Palio 3
Page:
5 / 15
Test functions
Navigate list
Decrease volume
Select
Program change / Start /
Stop test
Back to previous menu
Back to previous menu
Select Platform
Palio 2
Palio 3
Screen display
P2 HI RC
Button Function
Screen display
•
•
Version:
•
•
Screen display
P3 HI
P3 DWA
P3 CROS
•
•
Screen display
P3 CROS RC
P3 CROS WFT
Screen display
P3 CROS WFT
Start test
Stop test
Select test mode
Select test mode
Screen display
P3 DWA
Screen display
P3 DWA WFT
Start test
•
•
P3 CROS RC
Screen display
P3 DWA RC
P3 DWA WFT
Stop test
Select test mode
Screen display
P3 DWA RC
P3 HI
•
•
Screen display
P3 HI RC
P3 HI WFT
Screen display
P3 HI WFT
Start test
Stop test
Select test mode
Screen display
P3 HI RC
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
6 / 15
Wireless Functional Test Device
The Wireless Functional Test device should be used at any process step to check the wireless function of the hearing instrument
or digital wireless accessory.
For example, diagnose, component exchange & quality control as a part of the repair process & kit preparation or drilling & wiring,
closing & quality control as apart of the ITE new production process.
The WFT device is to replace the Lab myPilot for checking the wireless function of Palio 2 & Palio 3 hearing instruments.
In addition it is also possible to check the function of Palio 3 digital wireless accessories.
Product Compatibility Table
Ambra
Bolero
Solana
Virto
Cassia
Naìda Q
Naìda S
Sky Q
Nios S
Audéo Q
WH30
WH22
Palio 2 HI
Palio 3 HI
Palio 3 DWA
Audéo V
ComPilot II
Bolero V
ComPilot Air II
PilotOne II
Audéo S
The WFT device has a display and 3 touch pads to control the device.
It is powered by a mini USB cable connected to a PC or to the power socket.
There is also an acoustic out to connect a stethoclip to listen to the streamed
audio signal from DWAs & CROS II products.
The WFT device has an external HIBAN antenna which must be connected
to the Palio 2 or Palio 3 socket depending on which platform product is being
tested.
POWER
3.3V
iWiPro
Palio2
WIRELESS FUNCTIONAL TEST
Marconi
Palio3
Functional Test
Palio3 / Palio2
LINK
ACT
Mini-Din Mini USB
Acoustic Out
Wireless Functional Test Setup
A template will be provided to produce a control guide for the WFT. The control guide will show the acceptable working range for both Palio2 &
Palio3 hearing instruments. The test distance for the WFT device with hearing instruments is 18 to 22cm.
•
Power the WFT device via a mini-USB connected to a free USB port on a computer. Use a powered USB hub if there are no free USB ports on
your computer.
•
For a hearing instrument test connect the stethoclip to the HI.
The HI HIBAN antenna & the WFT
device antenna must be aligned
Palio2
POWER
3.3V
LINK
ACT
The HI functions correctly within
the control range of 18 – 22 cm
Palio 2
Vol-down
Prog
WIRELESS FUNCTIONAL TEST
Antenna
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
7 / 15
The WFT device can be used to test the remote control & the wireless streaming function of the P3 DWA.
•
The remote control test distance for PilotOne II & ComPilot II (without neckloop) is still 105cm.
•
For the ComPilot II streaming test the WFT device should be placed inside the ComPilot II neckloop.
•
For testing the ComPilot Air II for both remote control & streaming function the test distance in 35 cm.
•
For a DWA streaming test connect the stethoclip to the WFT device
ComPilot II streaming test, place the WFT
device in the middle of the neck loop
Palio3
POWER
3.3V
P3 DWA WFT
ON
LINK
ACT
WIRELESS FUNCTIONAL TEST
Antenna
ComPilot Air II remote control test 35cm
in either direction as shown.
Palio3
POWER
3.3V
P3 DWA RC
GoTo Next
LINK
ACT
Wireless Functional Test Device Self Test
Palio3
During Boot-up touch all three pads simultaneously to enter the “Self Test” mode.
•

•
Press any pad to continue.
- will be displayed in two rows across the LCD display.
•
Check LED – The “Link” LED is blinking
•
Press any pad to continue.
•
Audio Check – Clear beep is heard without distortion
•
Press any pad to continue.
•
Press & Release – touch the pad indicated with the #
•
After pressing all 3 pads the self test is complete.
•
When “Functional Test – Palio3” is displayed the device is ready for use.
Antenna
POWER
3.3V
LINK
ACT
Functional Test
Palio3
WIRELESS FUNCTIONAL TEST
WIRELESS FUNCTIONAL TEST
Antenna
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
8 / 15
Wireless Functional Test Device Test Modes
Palio3
HI RC – Test mode
•
Listen to the hearing instrument under test.
•
Use the WFT device to decrease the HI volume
•
Use the WFT device to change the HI program
POWER
3.3V
P3 HI RC
Vol-down
LINK
ACT
Prog
WIRELESS FUNCTIONAL TEST
Antenna
•
Use the remote control buttons on the DWA
•
Read the WFT Ddvice display to confirm the button function
Palio3
Antenna
P3 DWA RC
Volume UP
LINK
ACT
POWER
3.3V
P3 DWA RC
Volume DOWN
LINK
ACT
WIRELESS FUNCTIONAL TEST
Palio3
Antenna
WIRELESS FUNCTIONAL TEST
POWER
3.3V
Palio3
Antenna
POWER
3.3V
P3 DWA RC
GoTo Next
LINK
ACT
WIRELESS FUNCTIONAL TEST
DWA RC – Test mode
Palio 3 CROS
Palio3
POWER
3.3V
Palio3
P3 CROS
LINK
ACT
WIRELESS FUNCTIONAL TEST
Antenna
Begin with the P3 CROS RC. For the wireless function test a Stethoclip must be connected to the WFT device to listen to the streamed signal from
the CROS II hearing instrument. Use a good battery, position the CROS II HI within test range before turning on the CROS II HI.
Do not start the test until the CROS II HI is powered on.
Palio 3 CROS RC
POWER
3.3V
If no compatible device is found an error message will be displayed.
LINK
ACT
P3 CROS RC
Ready
WIRELESS FUNCTIONAL TEST
Enter the P3 CROS RC test mode.
The WFT device will search for a CROS II hearing instrument.
“Ready” will be displayed once the connection with the HI is made.
Palio3
Antenna
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
9 / 15
Palio3
Repeatedly pressing the same button will not change the display.
Alternating between user controls is recommended when possible.
POWER
3.3V
LINK
ACT
Palio 3 CROS Wireless Functional Test
Enter the P3 CROS WFT test mode.
The WFT device will search for a CROS II HI & set the CROS device to the streaming program.
“On” will be displayed once the connection made.
“Wait . . . . “ will be displayed during setup.
If no compatible device is found an error message will be displayed.
P3 CROS RC
Go To Next
WIRELESS FUNCTIONAL TEST
Test all available user controls.
Palio3
Antenna
POWER
3.3V
Palio 3
P3 CROS WFT
LINK
ACT
WIRELESS FUNCTIONAL TEST
To check the remote control function use the user controls on the CROS II HI, PS & VC.
The WFT device will display the received command. i.e. Program button = Go To Next.
Antenna
Palio3
POWER
3.3V
P3 CROS WFT
On
LINK
ACT
Wireless Functional Test Device Operation
Functional Test
Palio3
•
Use down arrow to scroll between P3 HI & P3 DWA.
•
Use carriage return to select.
•
Use back arrow to return to the previous menu.
Palio3
Antenna
POWER
3.3V
LINK
ACT
Palio3
P3 HI
WIRELESS FUNCTIONAL TEST
WIRELESS FUNCTIONAL TEST
Due to the noise environment & test set up it might not be possible to clearly hear
the “Streamed audio” from the CROS II HI.
Using you finger lightly rub across the microphone inlets.
Alternatively lightly blow across the microphone inlets to check the streaming function.
Antenna
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
P3 HI
•
Use back arrow to return to the previous menu.
Palio3
Antenna
POWER
3.3V
Use down arrow to decrease the volume.
•
Use carriage return to change the program.
•
Use back arrow to return to the previous menu.
Palio3
Antenna
POWER
3.3V
Use carriage return to turn on & off the sine stream.
•
Use back arrow to return to the previous menu.
P3 HI RC
Vol-down
LINK
ACT
Antenna
POWER
3.3V
P3 HI WFT
On
LINK
ACT
P3 DWA
P3 DWA RC Digital Wireless Accessory remote control test
•
Use down arrow to scroll between
P3 DWA RC test & P3 DWA WFT test.
•
Use carriage return to select.
•
Use back arrow to return to the previous menu.
Prog
Palio3
P3 HI
P3 HI WFT Streaming test from the WFT Device to the HI
•
P3 HI
P3 HI RC
LINK
ACT
P3 HI
P3 HI RC Hearing instrument remote control test
•
WIRELESS FUNCTIONAL TEST
Use carriage return to select.
10 / 15
WIRELESS FUNCTIONAL TEST
•
Page:
WIRELESS FUNCTIONAL TEST
Use down arrow to scroll between P3 HI RC test & P3 HI WFT test.
Palio3
Antenna
POWER
3.3V
LINK
ACT
P3 DWA
P3 DWA RC
WIRELESS FUNCTIONAL TEST
•
Version:
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
•
Use back arrow to return to the previous menu.
Antenna
POWER
3.3V
LINK
ACT
Palio3
P3 DWA
P3 DWA WFT Streaming test from the DWA to the WFT device
•
Use carriage return to turn on & off the test mode.
•
Use back arrow to return to the previous menu.
Antenna
POWER
3.3V
Use down arrow to scroll between Palio3 & Palio2 test modes.
•
Use carriage return to select.
•
Use back arrow to return to the previous menu.
Palio3
Antenna
POWER
3.3V
Use down arrow to decrease the volume.
•
Use carriage return to change the program.
•
Use back arrow to return to the previous menu.
Functional Test
Palio2
LINK
ACT
P2
P2 HI RC Hearing instrument remote control test
•
P3 DWA WFT
On
LINK
ACT
Palio2
•
P3 DWA RC
GoTo NEXT
WIRELESS FUNCTIONAL TEST
The WFT device displays which DWA button was pressed.
11 / 15
WIRELESS FUNCTIONAL TEST
•
Page:
Palio3
Antenna
POWER
3.3V
LINK
ACT
Palio2
Vol-down
Prog
WIRELESS FUNCTIONAL TEST
Use carriage return to turn on & off the test mode.
Palio3
P3 DWA
P3 DWA RC Digital Wireless Accessory remote control test
•
Version:
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
12 / 15
Compliance Information
Europe:
Declaration of conformity
Hereby Phonak AG declares that this Phonak product is in compliance with the essential requirements of the Radio and Telecommunications
Terminal Equipment Directive 1999/5/EC.
The full text of the Declaration of Conformity can be obtained from the manufacturer.
Notice 1:
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received, including interference that may cause undesired operation.
Ce produit répond aux exigences de la section 15 de la réglementation FCC et à la norme RSS-210 d’Industrie Canada. Son fonctionnement est
soumis aux deux conditions suivantes:
(1) cet appareil ne doit pas causer d’interférences nuisibles, et
(2) cet appareil doit accepter toutes les interférences reçues, y compris celles pouvant provoquer un fonctionnement préjudiciable.
Notice 2:
Changes or modifications made to this device not expressly approved by Phonak may void the FCC authorization to operate this device.
Notice 3:
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003
of Industry Canada.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the device and receiver.
•
Connect the device into an outlet on a circuit different from that to which the receiver is connected.
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
13 / 15
Information and Description of Symbols
With the CE symbol, Phonak AG confirms that
this Phonak product meets the requirements
of the R&TTE Directive 1999/5/EC on radio and
telecommunications equipment
This symbol indicates that it is important for the
user to read and take into account the relevant
information in this user guide.
This symbol indicates that it is important for the
user to pay attention to the relevant warning
notices in these user guides.
Important information for handling and product
safety.
Humidity transportation and storage:
<90% (non-condensing).
Humidity operation:
<95% (non condensing)
EMC and radio communications compliance label
Australia.
Operating
conditions
The device is designed such that it functions
without problems or restrictions if used as
intended, unless otherwise noted in this user
guide.
Temperature transport and storage:
–20° to +60° Celsius
(–4° to +140° Fahrenheit).
Temperature operation:
15° to 40° Celsius
(+60° to +104° Fahrenheit)
Keep dry
The symbol with the crossed-out garbage bin is to
make you aware that this device may not be thrown
away as normal household waste.
Please dispose of old or unused device, at waste
disposal sites intended for electronic waste, or
return it to your group company for disposal.
Proper disposal protects the environment and health.
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
14 / 15
Important Safety Information
The following pages contain important safety information.
Hazard warnings
For persons with active implantable medical devices
(i.e. pacemakers, defibrillators, etc.) the use of this device
is not permitted.
Only use accessories approved by Phonak AG, to avoid
any electrical shock.
Keep this device out of reach of children and mentally
challenged people or pets.
Using the device, its connectors or cables in any way
contradictory to their intended purpose as described in
this user guide can cause injury.
Changes or modifications to the device that were not
explicitly approved by Phonak are not permitted. Phonak
is not responsible for situations resulting from a modified
device.
The mini-USB port is to be used for the described
purpose only.
Opening the device might damage it. If problems occur
which cannot be resolved by following the remedy
guidelines consult your Phonak representative.
Do not use the device in explosive areas (mines or
industrial areas with danger of explosions, oxygen rich
environments or areas where flammable anesthetics are
handled) or where electronic equipment is prohibited.
Dispose of electrical components in accordance with your
local regulations.
Information on product safety
Protect the device from excessive moisture or heat
Keep the device of at least 10 cm away from any
kind of magnets.
Do not drop the device. Dropping it onto a hard surface
can damage the device.
Do not connect an USB cable exceeding 3 meters (9 feet)
in length to the device.
Protect the device connectors and plugs from dirt and
debris. Clean the device using a damp cloth. Never use
household cleaning products (washing powder, soap, etc.)
or alcohol to clean the device. Never use a microwave or
other heating devices to dry the device.
The mini-USB port is to be used for the described
purpose only.
The digitally-coded, inductive transmission technology
used in the device is highly reliable and experiences
virtually no interference from other devices. It should be
noted, however, that when operating the hearing system
near computer equipment, larger electronic installation or
other strong electromagnetic fields, it may be necessary
to be at least 60 cm (24”) away from the interfering
device to ensure proper operation.
When the device is not in use, disconnect from power
cable.
File:
000.000.015.286.pdf
Title:
Work Instruction Wireless Functional Test Device
Version:
Page:
15 / 15
Other Important Information
If you use several devices in the same building,
be aware that their inductive field can disturb one another if within a range of 2 meters (6 feet).
This may even occur when used in different rooms.
High-powered electronic equipment, larger electronic
installations and metallic structures may impair and
significantly reduce the operating range.
Revision History
Version:
Details:
First Release
Added French text page 12 (Notice 1)
Written:
see page 1
2015-05-26
11mgraeter
Approved:
Released:
see page 1
see page 1

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Instance ID                     : uuid:cfc48ca3-713f-4871-ba60-3b4892abe7f2
Original Document ID            : adobe:docid:indd:bed65562-c228-11df-8fa6-8576dc139522
Document ID                     : xmp.id:7AD46630A803E5119F94EC838A14AB97
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:FE970316A803E5119F94EC838A14AB97
Derived From Document ID        : xmp.did:3A30178749B7E4119770F1BEA5D3D4FB
Derived From Original Document ID: adobe:docid:indd:bed65562-c228-11df-8fa6-8576dc139522
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2015:05:26 15:07:40+02:00
Create Date                     : 2015:05:26 15:07:40+02:00
Modify Date                     : 2015:05:26 15:08:09+02:00
Metadata Date                   : 2015:05:26 15:08:09+02:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 15
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KWC-WFT1

Navigation menu