Phychips RED4S RFID Module User Manual

Phychips Inc. RFID Module

User Manual

Download: Phychips RED4S RFID Module User Manual
Mirror Download [FCC.gov]Phychips RED4S RFID Module User Manual
Document ID3769230
Application IDUyZ922i2krihv8yJfuqISw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize26.46kB (330812 bits)
Date Submitted2018-03-05 00:00:00
Date Available2018-09-01 00:00:00
Creation Date2018-03-02 17:06:50
Producing SoftwareAcrobat Distiller 15.0 (Windows)
Document Lastmod2018-03-02 17:06:50
Document TitleMicrosoft Word - RED4S User's Manuals_English_수정_20180302.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: jjlee

RED4S User’s Manuals
RED4S User’s Manuals - Preliminary Version
Contents
1.1
2.1
2.2
2.3
2.4
Pin Description ..................................................................................................................................3
RED4S Pin Description .......................................................................................................................3
Operation Method..............................................................................................................................5
Power Supply ......................................................................................................................................5
UART ...................................................................................................................................................5
RF In/Out .............................................................................................................................................7
GUI Control .........................................................................................................................................7
Specification ....................................................................................................................................12
2 March 2018
2 of 14
RED4S User’s Manuals - Preliminary Version
Pin Description
VCC36
GND
NC
NC
NC
NC
ISP_MO DEb
CSE
NC
P15
35
P00_RXD0
34
P01_TXD0
33
32
NC
31
NC
RESETb
SWCLK
30
29
28
27
NC
SWDIO
GND
GND
P12
13
23
GND
NC
14
GND
GND
15
16
22
21
20
VCC36P
GND
GND
19
GND
GND
GND
24
P16
RFIO
26
25
P17
10
11
12
17
18
VCC36P
Figure 1 Pin Description
1.1 RED4S Pin Description
No.
Pin Name
VCC36
GND
P04_SPI_TXD
P05_SPI_RXD
P06_SPI_CLK
P07_SPI_CS
ISP_MODEb
CSE
NC
10
P15
11
P16
2 March 2018
Description
DC Power for Reader SOC
Ground
Quasi-bi directional I/O port or SPI Output
Quasi-bi directional I/O port or SPI Input
Quasi-bi directional I/O port or SPI Clock
Quasi-bi directional I/O port or SPI Chip Select
When ISP_MODEb is Logic ‘Low’, ISP mode is set as shown below table
Pin No.
12
11
10
MODE
ISP_MODEb
P17
P16
P15
Normal
GPIO/INT GPIO/INT GPIO/INT
UART ISP
SPI ISP
[CAUTION] Except ISP mode, ISP_MODEb should be set logic ‘High’ for
robust stability for FLASH memory
Chip Select enable / module power enable 0:Disable 1: Enable
Not Connection
Quasi-bi directional I/O port
[NOTE] This pin is already used internally. So this pin should be only for ISP mode
Quasi-bi directional I/O port or External Interrupt 4
3 of 14
RED4S User’s Manuals - Preliminary Version
12
P17
13
P12_SCL
14
P11_SDA
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
GND
GND
GND
RF IO
GND
VCC36P
VCC36P
GND
GND
GND
GND
GND
GND
SWDIO
SWCLK
RESETb
NC
NC
NC
P01_TXD0
P00_RXD0
2 March 2018
Quasi-bi directional I/O port or External Interrupt 5
Quasi-bi directional I/O port I2C Clock
The pull-up resistor is always switched on.
Reserved Address : 0x70, 0x71
Quasi-bidirectional I/O port I2C Data In / Out
The pull-up resistor is always switched on.
Reserved Address : 0x70, 0x71
Ground
Ground
Ground
Rx Input / Tx Output
Ground
DC Power for Power Amp
DC Power for Power Amp
Ground
Ground
Ground
Ground
Ground
Ground
Serial Wire Debug data in out
Serial Wire Debug Clock
Reader SOC Reset signal 0: reset
Not Connection
Not Connection
Not Connection
Quasi-bi directional I/O port or UART0 Output
Quasi-bi directional I/O port or UART0 Input
4 of 14
RED4S User’s Manuals - Preliminary Version
Operation Method (Installation guide for power supply)
LDO
U2
VIN
VOUT
VCC=3.3V
EN
V_battery
to HOST
ENABLE
When ENABLE is high, RED4S ON
P15
P16
P17
P12
U1
10
11
12
13
14
15
16
RED4S
VCC36
GND1
NC1
NC2
NC3
NC4
ISP_MODE
CSE
NC5
P15
P16
P17
P12
NC6
GND2
GND3
GND4
RF I/O
GND5
17
18
19
RED4S
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
P00_RXD0
P01_TXD0
NC9
NC8
NC7
RESET
SWCLK
SWDIO
GND11
GND10
GND9
GND8
GND7
GND6
VCC36P
VCC36P
P00_RXD0
P01_TXD0
to HOST
UART TXD
UART RXD
SWCLK
SWDIO
SW1
J3
(optional)
CON3
(optional)
1RF_IO
V_battery
J1
GND
P17
CSE
ISP_MODEb
P15
P16
VCC36P
Figure 2 Application Circuit
V_battery
VCC=3.3V
SW1
U1
VOUT VIN
V_battery
EN
UART TXD
UART RXD
to HOST
GND
P00_RXD0
P01_TXD0
RESETb
VCC36
VCC36
VCC36P
10
12
14
11
13
J1
BM24-10DP/2-0.35V
(optional)
ENABLE
When ENABLE is high, RED4S ON
Figure 3 Application circuit: DC/Signal connector
2.1 Power Supply
DC power to operate RED4S is separated by 2 kinds. VCC36 is to supply for PR9200 which power range is
3.3 to 3.6 volts, VCC36P is to supply for power amp which power range is 3.3 to 4.2 volts.
In mobile device with battery, VCC36P can be connected to battery power directly. VCC36 pins need to
external LDO (or another device). As the Host control the LDO’s enable, user control power down mode of
module. If you do not control external LDO, you can control CSE pin to enter power down mode instead.
2.2 UART
The serial interface is assigned with two wires. RXD0, which pin is assigned to pin 35, is for receiving
command from host and TXD0, which pin is assigned to pin 34, is for transmitting response to host. Pin
connection is shown as below figure.
2 March 2018
5 of 14
RED4S User’s Manuals - Preliminary Version
Figure 4 Host MCU Connection
Following configuration is used for interfacing to USB transceiver.
Figure 5 USB transceiver Connection
2 March 2018
6 of 14
RED4S User’s Manuals - Preliminary Version
2.3 RF In/Out
RF I/O which assigned to Pin 18 is optimized with 50ohm impedance.
2.4 GUI Control
The RED Utility helps the user to start working with RED DK RFID reader quickly.
Follow below steps to run GUI.
Windows Start button  Program Menu  RED Utility_vX.X.X
Figure 6 RED Utility_vX.X.X
2 March 2018
7 of 14
RED4S User’s Manuals - Preliminary Version
2.4.1
Mode Change
RED Utility provides two view modes. User can select view mode depending on purpose of use between
Basic View Mode and Extended View Mode.
Figure 7 Basic View Mode
To change View Mode, click the extension button marked red in Figure 7 above.
2 March 2018
8 of 14
RED4S User’s Manuals - Preliminary Version
Figure 8 Extended View Mode
Always use Extended View Mode for measurement.
2.4.2
RED4S Connection
If hardware connection is valid, RED utility connect module REDx automatically.
If utility cannot connect hardware, please follow below step
Click “Connection->Connect” to connect to REDx-DK through USB-to-UART at main window
GUI will find the Device and synchronize parameters with REDx module automatically. If the GUI cannot find
the device automatically, Click “Connection->Port Setting” and select other Device. Default Baud rate is
115200 bit/s.
If the Device connected successfully, status bar will display “OPEN” state and device number and so on.
2 March 2018
9 of 14
RED4S User’s Manuals - Preliminary Version
2.4.3
Hardware Control
Click ‘H/W Control Tab.’ To control hardware.
2.4.3.1 Band(Region) Setting
To select operating band, band setting should be required. Select band in combo box and click Set button to
set operating band in group box ‘Frequency Control.’
2.4.3.2 Power Class Setting
Some countries classify channel number by power class. Click Get button and choose required power class.
And then click Set button to set finally.
2.4.3.3 Output Power setting
To set RED output power, select the Output Power combo box and click Set button.
2.4.3.4 CW (Continuous Wave) setting
It is only used for hardware debugging.
To set CW on, click Turn Tx CW on button. To set CW off, click Tx CW off button.
2 March 2018
10 of 14
RED4S User’s Manuals - Preliminary Version
2.4.4
Tag Inventory Procedure
Click Start button in Tag Information Tab to read UHF RFID tag with RED Utility.
Click Start button and Tag’s EPC information is displayed.
2 March 2018
11 of 14
RED4S User’s Manuals - Preliminary Version
Specification
Item
Unit
Frequency Range
Tx Power
Spurious
Impedance
VCC36P
DC Power
VCC36
Operating Temperature
Operating Humidity
Power Down
Current
Idle
Active
MHz
dBm
dBm
Ω
Size
mm
24.0 * 24.0 * 3.0
10
Weight
Test Condition
Specification
Typ.
max
No.
917.1
26
mA
926.9
27
Remark
PEAK
US (FCC 15C)
3.3
3.3
-20
°C
uA
min
Active current is
measured at 25dBm
with 50ohm load
50
3.6
RF I/O
4.2
3.6
70
90
20
20
•Device Name(Model Name) : RED4S
•FCC ID: Y3D-RED4S
•Name of Grantee: PHYCHIPS Inc.
•Production year, month, date:
•Manufacturer/Country: Korea
2 March 2018
12 of 14
RED4S User’s Manuals - Preliminary Version
FCC Information to User
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:
(1) the device may not cause interference, and
(2) the device must accept any interference, including interference that may cause undesired operation of this
device.
Caution : Any changes or modifications in construction of this device which are not expressly approved by the
party responsible for compliance could void the user's authority to operate the equipment
This device generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technical for help.
End Product Labeling
The module is labeled with its own FCC. If the FCC ID is not visible when the module is installed inside
another device, then the outside of the device into which the module is installed must also display a label
referring to the enclosed module. In that case, the final end product must be labeled in a visible area with the
following:
“Contains FCC ID: Y3D-RED4S”
OEM Responsibilities to comply with FCC
The module has been certified for integration into products only by OEM integrators under the following
condition:
- The antenna(s) must be installed such that a minimum separation distance of at least 20 cm
ismaintained between the radiator (antenna) and all persons at all times.
- The module is limited to installation in mobile or fixed applications.
- The transmitter module must not be co-located or operating in conjunction with any other antenna
ortransmitter except in accordance with FCC multi-transmitter product procedures.
- Separate approval will be required for all other operating configurations, including
portableconfigurations with respect to Part 2.1093 and different antenna configurations other than
suppliedantennas.
- The end product must have a power supply regulation circuit.
The supply voltage for this module is 3.3~3.6V. Please refer to the installation guide.(on page 5)
As long as the condition above is met, further transmitter testing will not be required. However, the OEM
integrator is still responsible for testing their end-product for any additional compliance requirements required
with this module installed (for example, digital device emissions, PC peripheral requirements, etc.).
In the event that these conditions cannot be met, then the FCC authorizations are no longer considered valid
and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be
responsible for re-evaluating the end product including this module and obtaining separate FCC authorizations.
- This device is intended only for OEM integrators
- For OEM integration only – device cannot be sold to general public.
- Manual Information to the End User
The OEM integrator has to be aware not to provide information to the end user regarding how
to install or remove this RF module in the user’s manual of the end product which integrates
this module.
2 March 2018
13 of 14
RED4S User’s Manuals - Preliminary Version
This device may only operate using an antenna of a type and maximum (or lesser) gain approved by
Phychips. Antenna types not included in the list, having a gain greater than the maximum gain indicated
for that type, are strictly prohibited for use with this transmitter.
Note
Peak Gain
Part Name
ANT
3.72 dBi
KSA – 921A6015B100B
2 March 2018
14 of 14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : jjlee
Create Date                     : 2018:03:02 17:06:50+09:00
Modify Date                     : 2018:03:02 17:06:50+09:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Format                          : application/pdf
Title                           : Microsoft Word - RED4S User's Manuals_English_수정_20180302.docx
Creator                         : jjlee
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:67501ca1-c7a1-4130-915a-2e1d44a6aa41
Instance ID                     : uuid:98f8fb0a-e7c2-4107-bbaf-bdcad9c1a5ae
Page Count                      : 14
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Y3D-RED4S

Navigation menu