Physik Instrumente P721T0007 P 721 PIFOC Z Drives
P721T0007_P-721_PIFOC_Z_Drives PD72Z1x PIFOC® Objective Scanning System 100 µm
User Manual: Physik Instrumente P-721 PIFOC® Piezo Flexure Objective Scanner
Open the PDF directly: View PDF .
Page Count: 22
Download | |
Open PDF In Browser | View PDF |
User Manual KSch/CBo, 2017-03-29 P721T0007, valid for P-721 P-721 Fast PIFOC® Piezo Nanofocusing Z Drive Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 2 / 22 2017-03-29 P721T0007, valid for P-721 Contents About this Document ......................................................................................................... 3 Symbols and Typographic Conventions ........................................................................................3 Figures..........................................................................................................................................3 Safety................................................................................................................................... 3 Intended Use ................................................................................................................................3 Safety Precautions ........................................................................................................................4 Product Description ........................................................................................................... 5 Model Overview ............................................................................................................................5 Product View.................................................................................................................................6 Product Labeling ...........................................................................................................................6 Scope of Delivery ..........................................................................................................................7 Accessories ..................................................................................................................................7 Suitable Electronics ......................................................................................................................8 Installation........................................................................................................................... 9 Connecting the P721 to a Protective Earth Conductor .................................................................9 Affixing the P-721 to the Microscope ...........................................................................................10 Installing the Objective ................................................................................................................10 Start-Up and Operation .................................................................................................... 11 General Notes on Start-Up and Operation ..................................................................................11 Starting Up and Operating the P-721 ..........................................................................................12 Discharging the P-721 ...................................................................................................... 12 Maintenance ...................................................................................................................... 13 Cleaning the P-721 .....................................................................................................................13 Customer Service ............................................................................................................. 14 Technical Data .................................................................................................................. 14 P-721 Fast PIFOC® Nanofocusing Z Drive .................................................................................14 Dimensions ....................................................................................................................... 16 P-721.xxQ, P-721.SL2 ................................................................................................................16 P-721.xDA ..................................................................................................................................17 Pin Assignments .............................................................................................................. 18 P-721.CLQ, P-721.0LQ...............................................................................................................18 P-721.SL2...................................................................................................................................19 P-721.CDx ..................................................................................................................................20 P-721.SDA..................................................................................................................................20 Maximum Ratings ............................................................................................................. 21 Ambient Conditions and Classifications ........................................................................ 21 Old Equipment Disposal .................................................................................................. 22 Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 3 / 22 2017-03-29 P721T0007, valid for P-721 About this Document Symbols and Typographic Conventions The following symbols and typographic conventions are used in this user manual: CAUTION Dangerous situation If not avoided, the dangerous situation will result in minor injury. Actions to take to avoid the situation. NOTICE Dangerous situation If not avoided, the dangerous situation will result in damage to the equipment. Actions to take to avoid the situation. INFORMATION Information for easier handling, tricks, tips, etc. Figures For better understandability, the colors, proportions, and degree of detail in illustrations can deviate from the actual circumstances. Photographic illustrations may also differ and must not be seen as guaranteed properties. Safety Intended Use The P-721 Z drive is a laboratory device as defined by DIN EN 61010-1. It is intended to be used in interior spaces and in an environment which is free of dirt, oil and lubricants. Based on its design and realization, the P-721 is intended for positioning and shifting microscope objectives in one axis. The P-721 can be mounted horizontally or vertically. The specifications refer to a vertically mounted P-721. The intended use of the P-721 is only possible in a completely assembled and connected state. The P-721 must be operated with a suitable controller that is available from PI. The controller is not included in the scope of delivery of the P-721. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 4 / 22 2017-03-29 P721T0007, valid for P-721 Safety Precautions CAUTION Dangerous voltage and residual charge on piezo actuators! The P-721 is driven by piezo actuators. Temperature changes and compressive stresses can induce charges in piezo actuators. After being disconnected from the electronics, piezo actuators can also stay charged for several hours. Touching or short-circuiting the contacts in the connector of the P-721 can lead to minor injuries. In addition, the piezo actuators can be destroyed by an abrupt contraction. Do not open the P-721. Discharge the piezo actuators before installation: Connect the Z drive to the switched-off PI controller for 10 seconds. Do not pull out the connector from the electronics during operation. For P-721 with sub-D connector: Touching the contacts in the connector can lead to an electric shock (max. 120 V DC) and minor injuries. Do not touch the contacts in the connector. Secure the connector of the piezo actuator with screws against being pulled out of the controller. CAUTION Risk of electric shock if the protective earth conductor is not connected! If a protective earth conductor is not or not properly connected, dangerous touch voltages can occur and there is a risk of electric shock. In the case of malfunction or failure of the system, touching the P-721 can result in minor injuries. Connect the P-721 to a protective earth conductor before start-up. Do not remove the protective earth conductor during operation. Use electrically conductive materials (e.g., screws and flat washers) for mounting the protective earth conductor. Make sure that the contact resistance is <0.1 Ω at 25 A at all connection points relevant for mounting the protective earth conductor. If the protective earth conductor has to be temporarily removed (e.g., for modifications), reconnect the P-721 to the protective earth conductor before starting it up again. NOTICE Unsuitable cables! Unsuitable cables can damage the electronics. Only use cables from PI for connecting the P-721 to the electronics. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 5 / 22 2017-03-29 P721T0007, valid for P-721 INFORMATION Extended cables can affect the performance of the P-721. Do not use cable extensions. If you need longer cables, contact our customer service department (p. 14). Product Description Model Overview The models of the P-721 differ in terms of: Sensor Connector Thread adapter Product number Description P-721.CLQ Fast PIFOC® nanofocusing Z drive, 100 µm, direct metrology, capacitive sensor, LEMO connector(s), for QuickLock thread adapters P-721.CDQ Fast PIFOC® nanofocusing Z drive, 100 µm, direct metrology, capacitive sensor, Sub-D connector, for QuickLock thread adapters P-721.CDA Fast PIFOC® nanofocusing Z drive, 100 µm, direct metrology, capacitive sensor, Sub-D connector, for large aperture QuickLock thread adapters P-721.SL2 Fast PIFOC® nanofocusing Z drive, 100 µm, SGS sensor, LEMO connector(s), for QuickLock thread adapters P-721.SDA Fast PIFOC® nanofocusing Z drive, 100 µm, SGS sensor, Sub-D connector, for large aperture QuickLock thread adapters P-721.0LQ Fast PIFOC® nanofocusing Z drive, 100 µm, open-loop, LEMO connector(s), for QuickLock thread adapters Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 6 / 22 2017-03-29 P721T0007, valid for P-721 Product View Figure 1: Components of the Z drive, example of a P-721.SDA, here without labeling 1 Cable exit 2 Threaded aperture 3 Base body 4 Protective earth connection Product Labeling Labeling Description P-721.SDA Product number (example), the digits after the period refer to the model 117013291 Serial number (example), individual for each P721 Meaning of the places (counting from left): 1 = internal information 2 and 3 = manufacturing year 4 to 9 = consecutive numbers PIFOC® Brand name Country of origin: Germany Country of origin Warning sign "Observe manual!" Old equipment disposal (p. 22) WWW.PI.WS Manufacturer's address (website) CE conformity mark Manufacturer's logo Symbol for the protective earth conductor (p. 9), marks the protective earth connection of the P721 Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 7 / 22 2017-03-29 P721T0007, valid for P-721 Scope of Delivery Product number Description P-721 Fast PIFOC® nanofocusing Z drive according to order (p. 5) 000036450 M4 screw set for protective earth, consisting of: 1 M4x8 flat-head screw with cross recess, ISO 7045 2 safety washers 2 flat washers PZ240EK Short instructions for piezo positioning systems P721T0002 Technical note for QuickLock thread option Accessories Extension tubes Product number Description P-721.90Q Extension tube, 12.5 mm, thread W0.8 x 1/36’’ P-721.91Q Extension tube, 12.5 mm, thread M25 x 1/36’’ P-721.92Q Extension tube, 12.5 mm, thread M26 x 1/36’’ P-721.93Q Extension tube, 12.5 mm, thread M27 x 1/36’’ P-721.94Q Extension tube, 12.5 mm, thread M28 x 1/36’’ P-721.95Q Extension tube, 12.5 mm, thread M32 x 1/36’’ P-721.96Q Extension tube, 12.5 mm, thread M26 x 1/36’’ P-721.98Q Extension tube, 12.5 mm, thread M19 x 1/36’’ QuickLock thread adapters Product number Description Only for P-721.xxQ / .SL2 P-721.02Q QuickLock thread adapter, M26 x 0.75 mm, Ø 21 mm P-721.03Q QuickLock thread adapter, M27 x 0.75 mm, Ø 21 mm P-721.04Q QuickLock thread adapter, M28 x 0.75 mm, Ø 21 mm P-721.05Q QuickLock thread adapter, M32 x 0.75 mm, Ø 21 mm P-721.06Q QuickLock thread adapter, M26 x 1/36’’, Ø 21 mm P-721.08Q QuickLock thread adapter, M19 x 0.75 mm, Ø 14 mm P-721.11Q QuickLock thread adapter, M25 x 0.75 mm, Ø 21 mm P-721.12Q QuickLock thread adapter, W0.8 x 1/36’’, Ø 14 mm Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 8 / 22 2017-03-29 P721T0007, valid for P-721 Product number Description Only for P-721.xxA P-721.02A QuickLock thread adapter for large apertures, M26 x 0.75 mm, Ø 23 mm P-721.03A QuickLock thread adapter for large apertures, M27 x 0.75 mm, Ø 24 mm P-721.04A QuickLock thread adapter for large apertures, M28 x 0.75 mm, Ø 25 mm P-721.05A QuickLock thread adapter for large apertures, M32 x 0.75 mm, Ø 29 mm P-721.06A QuickLock thread adapter for large apertures, M26 x 1/36’’, Ø 23 mm P-721.11A QuickLock thread adapter for large apertures, M25 x 0.75 mm, Ø 22 mm Adapter cables Product number Description P-895.1DLC Adapter cable Sub-D 7W2 (f) to LEMO for piezo actuator nanopositioning systems with capacitive sensors, 1 channel, 0.3 m. Fits controllers with LEMO connectors (1× voltage, 2× sensor). P-895.1LDC Adapter cable LEMO to sub-D 7W2 (m) for piezo actuator nanopositioning systems with capacitive sensors, 1 channel, 0.3 m. Fits motion controllers with Sub-D 7W2 (f) socket. Suitable Electronics Model / Mechanics Model / Electronics Capacitive sensor, Sub-D connection: E-621 controller module E-625 servo controller, bench-top P-721.CDQ E-665 display servo controller, with digital interface, bench-top P-721.CDA E-754 single-channel digital controller E-709 single-channel digital controller E-610 servo controller / amplifier E-500 modular piezo controller system with E-505 high-performance amplifier module and E-509 controller SGS sensor, Sub-D connection: E-721.SDA E-709 single-channel digital controller SGS sensor, LEMO connection: E-721.SL2 E-610 servo controller / amplifier E-625 servo controller, bench-top E-665 display servo controller, with digital interface, bench-top No sensor, LEMO connection: E-500 modular piezo controller system with E-505 high-performance amplifier module P-721.0LQ E-610.00 amplifier Capacitive sensor, LEMO connection: P-721.CLQ Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 9 / 22 2017-03-29 P721T0007, valid for P-721 Installation Connecting the P721 to a Protective Earth Conductor INFORMATION Observe the applicable standards for mounting the protective earth conductor. The P721 is equipped with an M4 hole for fastening the protective earth conductor. This hole is marked with the protective earth conductor symbol (see " Dimensions", p.16). Requirements You have read and understood the safety precautions (p. 4). The P-721 is not connected to the electronics. Tools and accessories Suitable protective earth conductor: Cross-sectional area of the cable ≥0.75 mm2 Supplied M4 protective earth screw set (p. 7) for connecting the protective earth conductor Suitable screwdriver Figure 2: Mounting of the protective earth conductor (profile view) 1 Base body of the P721 2 Flat washer 3 Safety washer 4 Screw 5 Cable lug 6 Protective earth conductor Connecting the P721 to the protective earth conductor 1. If necessary, fasten a suitable cable lug to the protective earth conductor. 2. Use the M4 screw (together with the washers and self-locking washers) to affix the cable lug of the protective earth conductor to the protective earth connection of the P-721 as shown in the profile view. 3. Tighten the M4 screw with a torque of 1.2 Nm to 1.5 Nm. 4. Make sure that the contact resistance at all connection points relevant for mounting the protective earth conductor is <0.1 Ω at 25 A. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 10 / 22 2017-03-29 P721T0007, valid for P-721 Affixing the P-721 to the Microscope Requirements You have read and understood the safety precautions (p. 4). Tools and accessories P721T0002 technical note for PIFOC® QuickLock thread option (p. 7) QuickLock thread adapter (p. 7) (not included) Affixing the P-721 to the Microscope Install the P-721 as described in the P721T0002 technical note for PIFOC® QuickLock thread option (p. 7). Installing the Objective Correct: Figure 3: Center of load close to aperture Incorrect: Mounting the load incorrectly causes high strain on the flexure guides in the Z drive, high torques and the danger of oscillations. Figure 4: Center of load far below the aperture Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 11 / 22 2017-03-29 P721T0007, valid for P-721 Requirements You have read and understood the safety precautions (p. 4). You have affixed the P-721 to the microscope (p. 10). Tools and accessories P721T0002 technical note for PIFOC® QuickLock thread option (p. 7) QuickLock thread adapter (p. 7) (not included) Objective to be installed (not included) Suitable tools Installing the objective Screw the objective into the P-721. See the P721T0002 technical note (p. 7) for details. Start-Up and Operation General Notes on Start-Up and Operation NOTICE Destruction of the piezo actuator by electric flashovers! The use of the P-721 in environments that increase the electrical conductivity can lead to the destruction of the piezo actuator by electric flashovers. Electric flashovers can be caused by moisture, high humidity, liquids and conductive materials such as metal dust. In addition, electric flashovers can also occur in certain air pressure ranges due to the increased conductivity of the air. Avoid operating the P-721 in environments that can increase the electric conductivity. Only operate the P-721 within the permissible ambient conditions and classifications (p. 21). NOTICE Destruction of the piezo actuator by continuously high voltage! The constant application of high voltage to piezo actuators can lead to leakage currents and flashovers that destroy the ceramic. If the P-721 is not used, but the controller is to remain switched on to ensure temperature stability: Set the piezo voltage to 0 V on the controller. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 12 / 22 2017-03-29 P721T0007, valid for P-721 NOTICE Uncontrolled oscillation! Oscillations can cause irreparable damage to the P-721. Oscillations are indicated by a humming and can result from the following causes: The load and/or dynamics of operation differ too much from the calibration settings. The P-721 is operated near its resonant frequency. If you notice oscillations, stop the P-721 immediately. INFORMATION Systems are calibrated at the factory to achieve optimum performance. Replacing the system components will cause a loss in performance when Z drives without ID chip are used, or whose ID chip does not contain any calibration data, or when Z drives with LEMO connectors or analog controllers are used. Only P-721.CDQ and P-721.CDA Z drives are equipped with an ID chip. Note the assignment of the Z drive axis to the controller channel, which is given by the calibration label of the piezo servo controller. For systems without ID chip: If the piezo servo controller or the Z drive has to be replaced, recalibrate the axis displacement (see controller manual) or contact our customer service department (p. 14). Starting Up and Operating the P-721 Requirements You have read and understood the safety precautions (p. 4). You have read and understood the general notes on start-up and operation (p. 11). Starting up and operating the P-721 Follow the instructions in the manual of the piezo controller used for start-up and operation of the P-721. Discharging the P-721 The P-721 must be discharged before demounting. Demounting is necessary e.g., before cleaning or transporting the P-721 as well as for modifications. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 13 / 22 2017-03-29 P721T0007, valid for P-721 Discharging a P-721 that is connected to the controller In closed-loop operation: 1. Switch off the servo mode on the controller. 2. Set the piezo voltage to 0 V on the controller. In open-loop operation: Set the piezo voltage to 0 V on the controller. Discharging a P-721 that is not connected to the controller Connect the P-721 to the switched-off PI controller for 10 seconds. Maintenance NOTICE Misalignment from loosening screws on the base body! The P-721 is maintenance-free and precisely aligned. Only loosen screws according to the instructions in this manual. Do not open the P-721. Cleaning the P-721 Requirements You have discharged the piezo actuators of the P-721. You have disconnected the P-721 from the controller. Cleaning the P-721 Clean the surface of the P-721 with a cloth that is lightly dampened with a mild cleanser or disinfectant (e.g., ethanol or isopropyl alcohol). Do not do any ultrasonic cleaning. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 14 / 22 2017-03-29 P721T0007, valid for P-721 Customer Service For inquiries and orders, contact your PI sales engineer or send us an email (info@pi.ws). If you have questions concerning your system, have the following information ready: − − − − Product and serial numbers of all products in the system Firmware version of the controller (if present) Version of the driver or the software (if present) Operating system on the PC (if present) If possible: Take photographs or make videos of your system that can be sent to our customer service department if requested. The latest versions of the user manuals are available for download on our website (www.pi.ws). Technical Data P-721 Fast PIFOC® Nanofocusing Z Drive Model P-721.CDQ P-721.SL2 P-721.0LQ Units Tolerance P-721.CDA P-721.SDA open-loop version Z Z Z Z Integrated sensor Capacitive Capacitive SGS - Open-loop travel, -20 to +120V 140 140 140 140 µm min. (+20 %/ -0 %) Closed-loop travel 100 100 100 - µm calibrated Open-loop resolution 0.5 0.5 0.5 0.5 nm typ. Closed-loop resolution 0.7 0.7 5 - nm typ. Linearity, closedloop 0.03 0.03 0.2 - % typ. Repeatability ±5 ±5 ±10 - nm typ. Runout θX, θY 13 13 13 13 µrad typ. Crosstalk in X, Y 100 100 100 100 nm typ. 0.3 0.3 0.3 0.3 N/µm ± 20 % Active axes P-721.CLQ Motion and positioning Mechanical properties Stiffness in motion direction Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 15 / 22 2017-03-29 P721T0007, valid for P-721 Model P-721.CLQ P-721.CDQ P-721.SL2 P-721.0LQ P-721.CDA P-721.SDA open-loop version Units Tolerance Unloaded resonant frequency 580 580 580 580 Hz ± 20 % Resonant frequency @ 120 g 235 235 235 235 Hz ± 20 % Resonant frequency @ 200 g 180 180 180 180 Hz ± 20 % Push/pull force capacity in motion direction 100 / 20 100 / 20 100 / 20 100 / 20 N max. Ceramic type PICMA® P-885 PICMA® P-885 PICMA® P-885 PICMA® P-885 Electrical capacitance 3.1 3.1 3.1 3.1 µF ± 20 % Dynamic operating current coefficient 3.9 3.9 3.9 3.9 µA/(Hz x µm) ± 20 % Operating temperature range* -20 to 80 -20 to 80 -20 to 80 -20 to 80 °C Material Aluminum Aluminum Aluminum Aluminum Max. objective diameter 39 39 39 39 mm Mass 0.24 0.24 0.22 0.22 kg Maximum objective diameter 39 39 39 39 mm Cable length 1 1 1 1 m LEMO Sub-D special Drive properties Miscellaneous Sensor- / voltage connection LEMO / Sub-D special ±5% ±10 mm LEMO (no sensor) *Specifications assured from 17°C to 23°C. The Z drive has to be recalibrated for temperatures outside this range. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 16 / 22 2017-03-29 P721T0007, valid for P-721 Dimensions Dimensions in mm. Note that the decimal places are separated by a comma in the drawings. P-721.xxQ, P-721.SL2 Figure 5: P-721.xxQ, P-721.SL2 (P-721.xxQ adapter to be ordered separately) Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 17 / 22 2017-03-29 P721T0007, valid for P-721 P-721.xDA Figure 6: P-721.xDA (P-721.xxA adapter to be ordered separately) Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 18 / 22 2017-03-29 P721T0007, valid for P-721 Pin Assignments P-721.CLQ, P-721.0LQ Figure 7: LEMO connectors of P-721.CLQ (top) and P-721.0LQ (bottom) 1 LEMO coaxial connector for capacitive sensor (Probe) 2 LEMO coaxial connector for capacitive sensor (Target) 3 LEMO coaxial connector for piezo voltage LEMO coaxial connectors Figure 8: LEMO coaxial connectors Connector Signal Function P Probe Probe sensor signal (moving part Cable shield of the capacitive sensor) T Target Target sensor signal (non-moving Cable shield part of the capacitive sensor) PZT PZT Piezo voltage Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Connector shell Ground of piezo voltage on cable shield Page 19 / 22 2017-03-29 P721T0007, valid for P-721 P-721.SL2 Figure 9: LEMO connectors of P-721.SL2 1 4-pin LEMO connector for strain gauge sensor 2 LEMO coaxial connector for piezo voltage LEMO connector for strain gauge sensor (front view): Pin Function 1 Vref 2 Sensor 1 (-) 3 Sensor 2 (+) 4 GND LEMO coaxial connector for piezo voltage: See LEMO connector PZT as used in “LEMO coaxial connectors” on p. 18. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 20 / 22 2017-03-29 P721T0007, valid for P-721 P-721.CDx Figure 10: Sub-D 7W2 (m) connector, front view Pin Signal Function A1 inner conductor Input Piezo voltage + A2 inner conductor Output Probe sensor signal (nonmoving part of the capacitive sensor) A2 outer conductor GND Shield 1 Bidirectional Data line for ID chip 2 GND Shield of Target Ground of ID chip when switched on 3 Input Piezo voltage – 4 N.C. Not connected 5 Input Target sensor signal (movable part of the capacitive sensor) The connector shell is connected to the cable shield. P-721.SDA Connector type: Sub-D 9 male, front view Pin Function 1 PZT + 2 Not connected 3 Not connected 4 SGS + 5 SGS GND 6 PZT GND 7 Not connected 8 SGS Ref. 9 SGS - The connector shell is connected to the cable shield. Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 21 / 22 2017-03-29 P721T0007, valid for P-721 Maximum Ratings The P-721 is designed for the following maximum ratings: Maximum operating Maximum operating Maximum power voltage frequency consumption (unloaded) -20 to 120 V 193 Hz 8.6 W Ambient Conditions and Classifications The following ambient conditions and classifications must be observed for the P-721: Area of application For indoor use only Maximum altitude 2000 m Air pressure 1100 hPa to 1013 hPa Relative humidity Highest relative humidity 80 % for temperatures up to 31 °C Decreasing linearly to 50 % relative humidity at 40 °C Storage temperature -20°C to 80°C Transport temperature -25°C to 85°C Overvoltage category II Protection class I Degree of pollution 1 Degree of protection according to IEC 60529 IP20 Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws Page 22 / 22 2017-03-29 P721T0007, valid for P-721 Old Equipment Disposal In accordance with EU law, electrical and electronic equipment may not be disposed of in EU member states via the municipal residual waste. Dispose of your old equipment according to international, national, and local rules and regulations. In order to fulfil its responsibility as the product manufacturer, Physik Instrumente (PI) GmbH & Co. KG undertakes environmentally correct disposal of all old PI equipment made available on the market after 13 August 2005 without charge. Any old PI equipment can be sent free of charge to the following address: Physik Instrumente (PI) GmbH & Co. KG Auf der Roemerstr. 1 D-76228 Karlsruhe, Germany Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Author : Schade, Kerstin Company : Polytec Create Date : 2017:06:30 09:22:35+02:00 Modify Date : 2017:07:07 12:45:57+02:00 Source Modified : D:20170630072228 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2017:07:07 12:45:57+02:00 Creator Tool : Acrobat PDFMaker 10.1 für Word Document ID : uuid:48ab8717-b5ac-477d-b364-2093d37cf417 Instance ID : uuid:d253ec87-a83c-4183-a1f1-eaade66f58bd Subject : 228 Format : application/pdf Creator : Schade, Kerstin Producer : Adobe PDF Library 10.0 Page Layout : OneColumn Page Count : 22EXIF Metadata provided by EXIF.tools