Physik Instrumente User Manual PL1x T0001

User_Manual_PL1xT0001 PICMA® Piezo Bender Actuators

User Manual: Physik Instrumente P-871 PICMA® Multilayer Bending Actuators

Open the PDF directly: View PDF PDF.
Page Count: 9

User Manual
MMa, 2017-02-20
PL1XT0001, valid for PL112 PL140
© 2017 PI Ceramic GmbH
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
PL112 PL140
Rectangular PICMA® Bender Piezo Actuators
Figure 1: Different rectangular PICMA® bender actuator models
INFORMATION
Before soldering, installing and operating the actuator, read these descriptions and
instructions carefully!
Safety
The following instructions will help you to obtain maximum performance from your actuator and avoid failures.
Failure to heed warnings in this document may result in injuries (caution) or material damage (notice).
CAUTION
Risk of electric shock!
These devices require adequately trained and experienced operating personnel.
Since temperature changes and compressive stresses can induce charges in piezo
actuators, even unused actuators may be a source of electric shocks.
To avoid electric shock:
Do not disassemble the piezoelectric actuator.
Make sure the bare piezoelectric actuator is discharged before touching it and
keep the soldering pads or wires shorted before installation.
Use gloves and safety glasses during handling.
User Manual
Page 2 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
NOTICE
Risk of damage from inadequate handling!
Inadequate shorting or handling may damage the actuator.
When shorting the wires or soldering pads of a possibly charged actuator,
always use a 10 kΩ current limiting resistor. Shorting a charged actuator without
limiting the discharge current can fracture the PZT ceramics due to the extremely
high dynamic forces caused by the rapid discharge.
Do not operate the actuator at higher voltages or different polarity than stated in
this document. For polarity information, see below.
Power off the actuator immediately if you hear or see any resonant behavior. For
the unloaded resonant frequency see Technical Data. Any resonant operation
should generally be avoided. Due to self-heating effects, the specified operating
temperature range of the actuator could be exceeded rapidly and irreparable
damage may occur.
Do not exceed the operating temperatures stated in the Technical Data section.
Before operating, check whether the instructions on soldering (if applicable),
installation and handling have been obeyed.
If you use a conductive support for fixing the actuator, electrically insulate the
corresponding parts of the soldering contacts.
Do not drop the piezo actuator; avoid subjecting it to any kind of mechanical
shock.
Do not exceed the maximum load (blocking force) specified in the Technical
Data.
NOTICE
Risk of damage from inadequate environmental conditions!
The actuator is sensitive to moisture, high relative humidity, liquids and contact with
any other conductive material.
Avoid storing or operating actuators under these environmental conditions since
they can cause dielectric breakdown.
Ensure that moisture is as low as possible.
User Manual
Page 3 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
NOTICE
Risk of damage from contamination!
To avoid contamination:
Do not handle the actuator with unprotected fingers.
Always use latex or nitrile gloves. The gloves must not be powdered.
Use parallel-action non-metallic tweezers to handle the actuator.
Use isopropanol to remove contaminants.
NOTICE
Risk of damage from thermal and mechanical stress
Be sure that the solder joint is not subject to “peeling” forces.
On the actuator surface, do not exceed 150 °C (302 °F). Except for soldering
(see below), this limitation applies to all processing steps as well as to operation.
Consider that the operation of the actuator can cause heating-up.
Do not file, sand or roughen the sides of the actuator.
Features
INFORMATION
Custom designs or different specifications on request.
Feel free to contact PI Ceramic GmbH!
Actuators with high reliability
Low temperature drift. Bidirectional displacements. Ceramic insulation, polymer-free. UHV-compatible to
10-9 hPa, no outgassing, high bakeout temperature. Reliable even under extreme conditions.
Fields of application
Research and industry, pneumatic valves, printing heads, vacuum applications. For medical technology, laser
control, sensor systems, automation tasks.
Suitable drivers
E-650 piezo amplifier for multilayer bender actuators, available from PI.
User Manual
Page 4 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
Product Details
Figure 2: Details of the actuator
1 Wire (only with PL1xx.11 models)
2 Plus or dot mark indicating positive (U+) contact position (not necessarily on the left side)
3 Soldering pad
4 Actuator body
Design and Functional Principle
Figure 3: Displacement ΔL effected by contraction (schematic; for single-side fixation)
The actuator, shown in Figure 3, is built up from thin piezoceramic layers and internal electrodes. The internal
electrodes extend to the rear end of the actuator and are connected to three external electrodes (called
“soldering pads” in the following text). The thickness of the piezo layers expands and the length contracts if a
voltage of the correct polarity is applied to the soldering pads. The bending movement (hence displacement) is
caused by the contraction (“d31-effect).
1
3
2
4
1
1
3
3
User Manual
Page 5 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
Installation
Mounting Wires / Soldering
We recommend ordering the actuator with already mounted wires (PL1xx.11). For PL1xx.10, follow the
instructions below.
The following extra materials are required for the soldering process:
o Solder: lead-free, made of the system L-Sn95..97 Ag3..4 Cu0.5..1.0
o Flux: defined as 1.1.1 or 1.1.3 accordingly to DIN EN 29454 Part 1 or defined as ROLO or
ROMO according to ANSI J-STD-004
o Wires: Stranded wires, ideal: AWG 32 (max. AWG 30)
Soldering wires to a PL1xx.10-type actuator
INFORMATION
The following procedure applies for each of the three wires and soldering pads
intended for connection to the piezo amplifier.
1. Twist and tin the stripped end of the wire. Trim to 2 mm.
Tin
Cut to 2 mm
Figure 4: Wire preparation steps (schematic)
2. Apply flux to the tinned end and to the soldering pad. Hold the wire flat with its end at that point.
3. Coat the soldering tip with a small amount of solder. The soldering temperature must not exceed
350 °C (662 °F).
4. On the soldering pad (flat top), hold the soldering tip against the tinned end of the wire for 1 to max.
2 seconds, until the solder flows. The solder joint must be flat or hemispherical.
Figure 5: Left: Solder joint shape (sectional view); right: sensitive edges; do not solder here!
During long and consecutive soldering, the soldering pad can be dissolved in the melt solder. Overall
soldering time has to be limited to 2 seconds.
Do not solder on the edge of the soldering pad (where the soldering contact is bent). Minimum distance
of the wire insulation to the edge of the soldering contact should be 0.5 mm.
5. Remove flux residues in a cleaning process by applying ethanol or a higher alcohol type. Use of an
ultrasonic bath is recommended.
min
.
0.5
Solder joint
Soldering pad of
actuator
Wire
User Manual
Page 6 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
Mechanical Installation
Single-sided fixation
For some applications, it is recommended to attach the actuator to metal or ceramic supports. This applies
especially to stiffer benders with a free length LF below 20 mm and lower displacements in applications with high
inducible force and resonance frequency requests. This avoids additional drift and elastic compliance which
could occur with soft polymer materials. Supports are not included in the delivery.
Epoxy adhesives are recommended for mechanical assembling. The curing temperature should be as low as
possible to reduce thermo-mechanical stress in the support.
Figure 6: Actuator in a single-sided configuration with free length LF
The actuator is mostly assembled in a single-sided (“cantilever”) configuration.
When fixing the actuator, note that the specified free length LF has to be maintained to achieve the nominal
values for the displacement as well as for the blocking force. Mounting it with a reduced free length would
reduce the displacement in a square relation and increase the blocking force in a linear relation.
We recommend fixation with an epoxy adhesive and according to the figure above. Alternative mounting
techniques include gluing the bender into a slot, clamping it between two soft layers or at least one soft layer
and one stiff layer or using an injection molding technique. These alternative configurations have to be tested
comprehensively before the actuator is used for serial production. Clamping pressures should be as low as
possible for the mechanical stability of the assembly.
Two-sided fixation
The actuators can also be mounted with two-sided fixation (see figure below). This assembly results in four
times higher induced force as well as four times lower displacement for the same bender at the same free
length compared to the single-sided fixation.
Figure 7: Actuator with two-sided fixation by rotational supports (clamps), with central output and free length LF
A central output can be realized by gluing a metal or ceramic part to the actuator. The assembly can be
supported by a central hole which is not included in the standard product. A low-curing two-component standard
epoxy adhesive is recommended.
L
F
LF
User Manual
Page 7 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
Figure 8: Metal flex configuration Figure 9: Soft/stiff-combination cylinder assembly
Figure 8 and Figure 9 show two possible configurations for the assembly at the two outer sides of the actuator.
For longer models with free length above 20 mm, it may be necessary to consider not only the rotational but
also the lateral softness because the bender contracts laterally during operation.
The mounting shown in Figure 8 comprises folded metal clamps which are axially stiff and glued to the bender
with an insulating epoxy adhesive. The pivot point of the metal flexes should be as close to the bender as
possible. In Figure 9, a soft polymer cylinder presses the bender against stiffer rotatable metal or ceramic
cylinders beneath the actuator.
These mounting types have to be comprehensively tested before application in serial production, especially for
clamped assemblies. The soldering pads have to be appropriately insulated from the mounting.
Electric Connection
INFORMATION
We recommend using the E-650 piezo amplifier available from PI.
Figure 10: Electric connection scheme with
(1) – (3) Soldering pads No.1, 2, 3 (and for PL1xx.11: related wires)
See Figure 10: In relation to the dot or “plus” mark, the nearest soldering pad No. 3 (or red wire respectively, if a
PL1xx.11 model is used) must be connected to U+ and the most distant soldering pad No. 1 (or yellow wire for
PL1xx.11) has to be attached to U- respectively. Soldering pad No. 2 (or blue wire for PL1xx.11) is intended for
connection to the control voltage Uc generated by the piezo amplifier.
User Manual
Page 8 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
Operation
NOTICE
Improper polarity and voltage can destroy the actuator.
Do not reverse polarity.
Between soldering pads / wires No. 3 and 1 and for Uc: Do not exceed 60 V. See
Figure 10.
Controlling the Displacement via Applied Voltages
Single voltage control
If a voltage is applied between two soldering pads, the actuator bends in one direction only (example: for
PL127.10 with 60 V and single-sided fixation, a displacement of max. 450 μm is reached at the end opposite to
the fixation. The active piezo layers contract in length, and the other layers become passive (no shape change).
Full differential-voltage control (recommended)
Based on the full differential-voltage control (see Figure 10), bending can be controlled over the full range in
both directions.
Operating options
Regarding the voltages, the options shown in the table below apply.
Soldering contact / wire no. (according to Figure 10)
1
2
3
Voltage designation
U-
Uc
U+
Option 1
GND
0 V to 60 V
60 V
Option 2
-30 V
-30 V to 30 V
30 V
Displacement direction
If the soldering pads of the bender point to the top and the bender is driven with a positive voltage at contact
no. 3 and 2 and GND at contact no. 1, its free end bends to the top for single sided fixation, or its center bends
to the bottom for two-sided fixation, respectively.
Storage
Store the components in a dry place (non-condensing) at room temperature.
User Manual
Page 9 / 9
2017-02-20
PL1XT0001, valid for PL112 PL140
PI Ceramic GmbH Keramische Technologien und Bauelemente, Lindenstraße, D- 07589 Lederhose
Phone: +49 36604 882-0, Fax: +49 36604 882-4109, Email: info@piceramic.de, www.piceramic.de
Dimensions
For the type-specific values, see Technical Data below. Tolerance values in mm.
Figure 11: Dimension designations of the PL1xx with
(1) Recommended position of a support for single-sided fixation (“clamping”; see dashed lines;
support is not included in the delivery)
Technical Data
* depending on electric connection option, see above
** at Upp = 1 V (differential peak voltage), 1 kHz, 20 °C
*** at Upp = 1 V, without mass load
Note: Specifications may vary depending on the actual clamping / mounting conditions and on the applied
mechanical load. Values in italics only applicable for single-sided mounting with free length LF!
PL112.10 PL122.10 PL127.10 PL128.10 PL140.10 Unit Tole-
rance
Operating
voltage*
0 to 60 or
-30 to 30
0 to 60 or
-30 to 30
0 to 60 or
-30 to 30
0 to 60 or
-30 to 30
0 to 60 or
-30 to 30
V
Displacement ±100 ±310 ±450 ±450 ±1000 μm ±20%
Free length LF 12 22 27 28 40 mm
Length L 18 25 31 36 45 mm ±0.5 mm
Width W 9.60 ±0.2 9.60 ±0.2 9.60 ±0.2 6.15 ±0.1 11.00 ±0.2 mm
Height H 0.67 0.67 0.67 0.67 0.55 mm ±0.1 mm
Blocking force ±2.1 ±1.25 ±1.1 ±0.55 ±0.5 N ±20%
Electrical
capacitance** 2 * 1.1 2 * 2.5 2 * 3.4 2 * 1.2 2 * 4.1 μF ±20%
Resonant
frequency*** 1800 600 420 360 160 Hz ±20%
Operating
temperature -20 to 150 -20 to 85 -20 to 85 -20 to 150 -20 to 85 °C
Piezo ceramic
type PIC252 PIC 251 PIC 251 PIC252 PIC 251
L
L
F
W