Pismolabs Technology P1AC1DUO Peplink / Pepwave / Pismo Labs wireless product User Manual

Pismo Labs Technology Limited Peplink / Pepwave / Pismo Labs wireless product Users Manual

Users Manual

 Pepwave MAX and Surf User Manual http://www.pepwave.com  101    Copyright @ 2016 Pepwave   Application Compatibility highest application compatibility. Normal Application Compatibility Outbound traffic from a source LAN device to the same destination Internet IP address will be routed through the same WAN connection persistently, regardless of protocol. This option provides high compatibility to most applications, and users still benefit from WAN link load balancing when multiple Internet servers are accessed. Custom  Outbound traffic behavior can be managed by defining rules in a custom rule table. A default rule can be defined for connections that cannot be matched with any of the rules.  The default policy is Normal Application Compatibility. Tip Want to know more about creating outbound rules? Visit our YouTube Channel for a video tutorial!  http://youtu.be/rKH4AS_bQnE 15.2  Custom Rules for Outbound Policy Click    in the Outbound Policy form. Choose Custom and press the Save button.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  102    Copyright @ 2016 Pepwave   The bottom-most rule is Default. Edit this rule to change the device’s default manner of controlling outbound traffic for all connections that do not match any of the rules above it. Under the Service heading, click Default to change these settings.  To rearrange the priority of outbound rules, drag and drop them into the desired sequence.   By default, Auto is selected as the Default Rule. You can select Custom to change the algorithm to be used. Please refer to the upcoming sections for the details on the available algorithms.  To create a custom rule, click Add Rule at the bottom of the table. Note that some Pepwave routers display this button at Advanced>PepVPN>PepVPN Outbound Custom Rules.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  103    Copyright @ 2016 Pepwave    New Custom Rule Settings Service Name  This setting specifies the name of the outbound traffic rule. Enable This setting specifies whether the outbound traffic rule takes effect. When Enable is checked, the rule takes effect: traffic is matched and actions are taken by the Pepwave router based on the other parameters of the rule. When Enable is unchecked, the rule does not take effect: the Pepwave router disregards the other parameters of the rule.  Click the drop-down menu next to the checkbox to apply a time schedule to this custom rule. Source  This setting specifies the source IP address, IP network, or MAC address for traffic that matches the rule. Destination This setting specifies the destination IP address, IP network, or domain name for traffic that matches the rule.  If Domain Name is chosen and a domain name, such as foobar.com, is entered, any outgoing accesses to foobar.com and *.foobar.com will match this criterion. You may enter a wildcard (.*) at the end of a domain name to match any host with a name having the domain name in the middle. If you enter foobar.*, for example, www.foobar.com, www.foobar.co.jp, or foobar.co.uk will also match. Placing wildcards in any other position is not supported. NOTE: if a server has one Internet IP address and multiple server names, and if one of the names is defined here, accesses to any one of the server names will also match this rule.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  104    Copyright @ 2016 Pepwave   Protocol and Port This setting specifies the IP protocol and port of traffic that matches this rule. Algorithm This setting specifies the behavior of the Pepwave router for the custom rule. One of the following values can be selected (note that some Pepwave routers provide only some of these options):   Weighted Balance  Persistence  Enforced  Priority  Overflow  Least Used  Lowest Latency The upcoming sections detail the listed algorithms. Terminate Sessions on Link Recovery This setting specifies whether to terminate existing IP sessions on a less preferred WAN connection in the event that a more preferred WAN connection is recovered. This setting is applicable to the Weighted, Persistence, and Priority algorithms. By default, this setting is disabled. In this case, existing IP sessions will not be terminated or affected when any other WAN connection is recovered. When this setting is enabled, existing IP sessions may be terminated when another WAN connection is recovered, such that only the preferred healthy WAN connection(s) is used at any point in time.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  105    Copyright @ 2016 Pepwave   15.2.1 Algorithm: Weighted Balance This setting specifies the ratio of WAN connection usage to be applied on the specified IP protocol and port. This setting is applicable only when Algorithm is set to Weighted Balance.  The amount of matching traffic that is distributed to a WAN connection is proportional to the weight of the WAN connection relative to the total weight. Use the sliders to change each WAN’s weight. For example, with the following weight settings: • Ethernet WAN1:  10 • Ethernet WAN2: 10 • Wi-Fi WAN: 10 • Cellular 1: 10 • Cellular 2: 10 • USB:  10 Total weight is 60 = (10 +10 + 10 + 10 + 10 + 10). Matching traffic distributed to Ethernet WAN1 is 16.7% = (10 / 60 x 100%. Matching traffic distributed to Ethernet WAN2 is 16.7% = (10 / 60) x 100%. Matching traffic distributed to Wi-Fi WAN is 16.7% = (10 / 60) x 100%. Matching traffic distributed to Cellular 1 is 16.7% = (10 / 60) x 100%. Matching traffic distributed to Cellular 2 is 16.7% = (10 / 60) x 100%. Matching traffic distributed to USB is 16.7% = (10 / 60) x 100%.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  106    Copyright @ 2016 Pepwave   15.2.2 Algorithm: Persistence The configuration of persistent services is the solution to the few situations where link load distribution for Internet services is undesirable. For example, for security reasons, many e-banking and other secure websites terminate the session when the client computer’s Internet IP address changes mid-session.   In general, different Internet IP addresses represent different computers. The security concern is that an IP address change during a session may be the result of an unauthorized intrusion attempt. Therefore, to prevent damages from the potential intrusion, the session is terminated upon the detection of an IP address change. Pepwave routers can be configured to distribute data traffic across multiple WAN connections. Also, the Internet IP depends on the WAN connections over which communication actually takes place. As a result, a LAN client computer behind the Pepwave router may communicate using multiple Internet IP addresses. For example, a LAN client computer behind a Pepwave router with three WAN connections may communicate on the Internet using three different IP addresses. With the persistence feature, rules can be configured to enable client computers to persistently utilize the same WAN connections for e-banking and other secure websites. As a result, a client computer will communicate using one IP address, eliminating the issues mentioned above.   There are two persistent modes: By Source and By Destination.   By Source:  The same WAN connection will be used for traffic matching the rule and originating from the same machine, regardless of its destination. This option will provide the highest level of application compatibility. By Destination:  The same WAN connection will be used for traffic matching the rule, originating from the same machine, and going to the same destination. This option can better distribute loads to WAN connections when there are only a few client machines. The default mode is By Source. When there are multiple client requests, they can be distributed (persistently) to WAN connections with a weight. If you choose Auto in Load Distribution, the weights will be automatically adjusted according to each WAN’s Downstream Bandwidth which is specified in the WAN settings page). If you choose Custom, you can customize the weight of each WAN manually by using the sliders.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  107    Copyright @ 2016 Pepwave   15.2.3 Algorithm: Enforced This setting specifies the WAN connection usage to be applied on the specified IP protocol and port. This setting is applicable only when Algorithm is set to Enforced.  Matching traffic will be routed through the specified WAN connection, regardless of the health check status of the WAN connection. Starting from Firmware 5.2, outbound traffic can be enforced to go through a specified SpeedFusionTM connection. 15.2.4 Algorithm: Priority This setting specifies the priority of the WAN connections used to route the specified network service. The highest priority WAN connection available will always be used for routing the specified type of traffic. A lower priority WAN connection will be used only when all higher priority connections have become unavailable.   Starting from Firmware 5.2, outbound traffic can be prioritized to go through SpeedFusionTM connection(s). By default, VPN connections are not included in the priority list.  Tip Configure multiple distribution rules to accommodate different kinds of services. 15.2.5 Algorithm: Overflow The traffic matching this rule will be routed through the healthy WAN connection that has the highest priority and is not in full load. When this connection gets saturated, new sessions will be routed to the next healthy WAN connection that is not in full load.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  108    Copyright @ 2016 Pepwave    Drag and drop to specify the order of WAN connections to be used for routing traffic. Only the highest priority healthy connection that is not in full load will be used. 15.2.6 Algorithm: Least Used  The traffic matching this rule will be routed through the healthy WAN connection that is selected in Connection and has the most available download bandwidth. The available download bandwidth of a WAN connection is calculated from the total download bandwidth specified on the WAN settings page and the current download usage. The available bandwidth and WAN selection is determined every time an IP session is made. 15.2.7 Algorithm: Lowest Latency  The traffic matching this rule will be routed through the healthy WAN connection that is selected in Connection and has the lowest latency. Latency checking packets are issued periodically to a nearby router of each WAN connection to determine its latency value. The latency of a WAN is the packet round trip time of the WAN connection. Additional network usage may be incurred as a result. Tip The roundtrip time of a 6M down/640k uplink can be higher than that of a 2M down/2M up link because the overall round trip time is lengthened by its slower upload bandwidth, despite its higher downlink speed. Therefore, this algorithm is good for two scenarios: • All WAN connections are symmetric; or
 Pepwave MAX and Surf User Manual http://www.pepwave.com  109    Copyright @ 2016 Pepwave   • A latency sensitive application must be routed through the lowest latency WAN, regardless of the WAN’s available bandwidth. 15.2.8 Expert Mode  Expert Mode is available on some Pepwave routers for use by advanced users. To enable the feature, click on the help icon and click turn on Expert Mode. In Expert Mode, a new special rule, SpeedFusionTM Routes, is displayed in the Custom Rules table. This rule represents all SpeedFusionTM routes learned from remote VPN peers. By default, this bar is on the top of all custom rules. This position means that traffic for remote VPN subnets will be routed to the corresponding VPN peer. You can create custom Priority or Enforced rules and move them  above the bar to override the SpeedFusionTM routes.  Upon disabling Expert Mode, all rules above the bar will be removed.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  110    Copyright @ 2016 Pepwave   16 Inbound Access 16.1  Port Forwarding Service Pepwave routers can act as a firewall that blocks, by default, all inbound access from the Internet. By using port forwarding, Internet users can access servers behind the Pepwave router. Inbound port forwarding rules can be defined at Advanced>Port Forwarding.  To define a new service, click Add Service.   Port Forwarding Settings Enable This setting specifies whether the inbound service takes effect. When Enable is checked, the inbound service takes effect: traffic is matched and actions are taken by the Pepwave router based on the other parameters of the rule. When this setting is disabled, the inbound service does not take effect: the Pepwave router disregards the other parameters of the rule. Service Name This setting identifies the service to the system administrator. Valid values for this setting consist of only alphanumeric and underscore “_” characters. IP Protocol The IP Protocol setting, along with the Port setting, specifies the protocol of the service as TCP, UDP, ICMP, or IP. Traffic that is received by the Pepwave router via the specified protocol at the specified port(s) is forwarded to the LAN hosts specified by the Servers setting. Please see below for details on the Port and Servers settings. Alternatively, the Protocol Selection Tool drop-down menu can be used to automatically fill in the protocol and a single port number of common Internet services (e.g. HTTP, HTTPS, etc.).  After selecting an item from the Protocol Selection Tool drop-down menu, the protocol and port number remain manually modifiable.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  111    Copyright @ 2016 Pepwave   Port The Port setting specifies the port(s) that correspond to the service, and can be configured to behave in one of the following manners: Any Port, Single Port, Port Range, Port Map, and Range Mapping  Any Port: all traffic that is received by the Pepwave router via the specified protocol is forwarded to the servers specified by the Servers setting. For example, with IP Protocol set to TCP, and Port set to Any Port, all TCP traffic is forwarded to the configured servers.  Single Port: traffic that is received by the Pepwave router via the specified protocol at the specified port is forwarded via the same port to the servers specified by the Servers setting.  For example, with IP Protocol set to TCP, and Port set to Single Port and Service Port 80, TCP traffic received on port 80 is forwarded to the configured servers via port 80.  Port Range: traffic that is received by the Pepwave router via the specified protocol at the specified port range is forwarded via the same respective ports to the LAN hosts specified by the Servers setting. For example, with IP Protocol set to TCP, and Port set to Port Range and Service Ports 80-88, TCP traffic received on ports 80 through 88 is forwarded to the configured servers via the respective ports.  Port Mapping: traffic that is received by Pepwave router via the specified protocol at the specified port is forwarded via a different port to the servers specified by the Servers setting.   For example, with IP Protocol set to TCP, and Port set to Port Mapping, Service Port 80, and Map to Port 88, TCP traffic on port 80 is forwarded to the configured servers via port 88. (Please see below for details on the Servers setting.)  Range Mapping: traffic that is received by the Pepwave router via the specified protocol at the specified port range is forwarded via a different port to the servers specified by the Servers setting. Inbound IP Address(es) This setting specifies the WAN connections and Internet IP address(es) from which the service can be accessed. Server IP Address This setting specifies the LAN IP address of the server that handles the requests for the service.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  112    Copyright @ 2016 Pepwave   16.1.1 UPnP / NAT-PMP Settings UPnP and NAT-PMP are network protocols which allow a computer connected to the LAN port to automatically configure the router to allow parties on the WAN port to connect to itself. That way, the process of inbound port forwarding becomes automated.  When a computer creates a rule using these protocols, the specified TCP/UDP port of all WAN connections' default IP address will be forwarded. Check the corresponding box(es) to enable UPnP and/or NAT-PMP. Enable these features only if you trust the computers connected to the LAN ports.  When the options are enabled, a table listing all the forwarded ports under these two protocols can be found at Status>UPnP / NAT-PMP.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  113    Copyright @ 2016 Pepwave   17 NAT Mappings NAT mappings allow IP address mapping of all inbound and outbound NAT’dt raffic to and from an internal client IP address. Settings to configure NAT mappings are located at Advanced>NAT Mappings.  To add a rule for NAT mappings, click Add NAT Rule.   NAT Mapping Settings LAN Client(s) NAT mapping rules can be defined for a single LAN IP Address, an IP Range, or an IP Network. Address This refers to the LAN host’s private IP address. The system maps this address to a number of public IP addresses (specified below) in order to facilitate inbound and outbound traffic. This option is only available when IP Address is selected. Range The IP range is a contiguous group of private IP addresses used by the LAN host. The system maps these addresses to a number of public IP addresses (specified below) to facilitate outbound traffic. This option is only available when IP Range is selected. Network The IP network refers to all private IP addresses and ranges managed by the LAN host. The system maps these addresses to a number of public IP addresses (specified below) to facilitate outbound traffic. This option is only available when IP Network is selected.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  114    Copyright @ 2016 Pepwave   Inbound Mappings This setting specifies the WAN connections and corresponding WAN-specific Internet IP addresses on which the system should bind. Any access to the specified WAN connection(s) and IP address(es) will be forwarded to the LAN host. This option is only available when IP Address is selected in the LAN Client(s) field.  Note that inbound mapping is not needed for WAN connections in drop-in mode or IP forwarding mode. Also note that each WAN IP address can be associated to one NAT mapping only. Outbound Mappings This setting specifies the WAN IP addresses that should be used when an IP connection is made from a LAN host to the Internet. Each LAN host in an IP range or IP network will be evenly mapped to one of each selected WAN's IP addresses (for better IP address utilization) in a persistent manner (for better application compatibility).   Note that if you do not want to use a specific WAN for outgoing accesses, you should still choose default here, then customize the outbound access rule in the Outbound Policy section. Also note that WAN connections in drop-in mode or IP forwarding mode are not shown here. Click Save to save the settings when configuration has been completed. Important Note Inbound firewall rules override the Inbound Mappings settings.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  115    Copyright @ 2016 Pepwave   18 QoS 18.1  User Groups LAN and PPTP clients can be categorized into three user groups: Manager, Staff, and Guest. This menu allows you to define rules and assign client IP addresses or subnets to a user group. You can apply different bandwidth and traffic prioritization policies on each user group in the Bandwidth Control and Application sections (note that the options available here vary by model). The table is automatically sorted by rule precedence. The smaller and more specific subnets are put towards the top of the table and have higher precedence; larger and less specific subnets are placed towards the bottom.  Click the Add button to define clients and their user group. Click the   button to remove the defined rule. Two default rules are pre-defined and put at the bottom. They are All DHCP reservation clients and Everyone, and they cannot be removed. The All DHCP reservation client represents the LAN clients defined in the DHCP Reservation table on the LAN settings page. Everyone represents all clients that are not defined in any rule above. Click on a rule to change its group.    Add / Edit User Group Subnet / IP Address From the drop-down menu, choose whether you are going to define the client(s) by an IP Address or a Subnet. If IP Address is selected, enter a name defined in DHCP reservation table or a LAN client's IP address. If Subnet is selected, enter a subnet address and specify its subnet mask. Group  This field is to define which User Group the specified subnet / IP address belongs to.  Once users have been assigned to a user group, their internet traffic will be restricted by rules defined for that particular group. Please refer to the following two sections for details.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  116    Copyright @ 2016 Pepwave    18.2  Bandwidth Control You can define a maximum download speed (over all WAN connections) and upload speed (for each WAN connection) that each individual Staff and Guest member can consume. No limit can be imposed on individual Manager members. By default, download and upload bandwidth limits are set to unlimited (set as 0).  18.3  Application 18.3.1 Application Prioritization On many Pepwave routers, you can choose whether to apply the same prioritization settings to all user groups or customize the settings for each group.   Three application priority levels can be set: ↑↑↑↑High,━━━━ Normal, and↓↓↓↓Low. Pepwave routers can detect various application traffic types by inspecting the packet content. Select an application by choosing a supported application, or by defining a custom application manually. The priority preference of supported applications is placed at the top of the table. Custom applications are at the bottom.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  117    Copyright @ 2016 Pepwave   18.3.2 Prioritization for Custom Applications Click the Add button to define a custom application. Click the button   in the Action column to delete the custom application in the corresponding row. When Supported Applications is selected, the Pepwave router will inspect network traffic and prioritize the selected applications. Alternatively, you can select Custom Applications and define the application by providing the protocol, scope, port number, and DSCP value.   18.3.3 DSL/Cable Optimization DSL/cable-based WAN connections have lower upload bandwidth and higher download bandwidth. When a DSL/cable circuit's uplink is congested, the download bandwidth will be affected. Users will not be able to download data at full speed until the uplink becomes less congested. DSL/Cable Optimization can relieve such an issue. When it is enabled, the download speed will become less affected by the upload traffic. By default, this feature is enabled.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  118    Copyright @ 2016 Pepwave   19 Firewall A firewall is a mechanism that selectively filters data traffic between the WAN side (the Internet) and the LAN side of the network. It can protect the local network from potential hacker attacks, access to offensive websites, and/or other inappropriate uses. The firewall functionality of Pepwave routers supports the selective filtering of data traffic in both directions:  Outbound (LAN to WAN)  Inbound (WAN to LAN)  The firewall also supports the following functionality:  Intrusion detection and DoS prevention  Web blocking  With SpeedFusionTM enabled, the firewall rules also apply to VPN tunneled traffic.  19.1  Outbound and Inbound Firewall Rules 19.1.1 Access Rules The outbound firewall settings are located at Advanced>Firewall>Access Rules>Outbound Firewall Rules.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  119    Copyright @ 2016 Pepwave     Click Add Rule to display the following screen:  Inbound  firewall  settings  are  located  at Advanced>Firewall>Access  Rules>Inbound Firewall Rules.  Click Add Rule to display the following screen:  Rules are matched from top to bottom. If a connection matches any one of the upper rules, the matching process will stop. If none of the rules match, the Default rule will be applied. By default, the Default rule is set as Allow for both outbound and inbound access.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  120    Copyright @ 2016 Pepwave   Inbound / Outbound Firewall Settings Rule Name  This setting specifies a name for the firewall rule. Enable This setting specifies whether the firewall rule should take effect. If the box is checked, the firewall rule takes effect. If the traffic matches the specified protocol/IP/port, actions will be taken by the Pepwave router based on the other parameters of the rule. If the box is not checked, the firewall rule does not take effect. The Pepwave router will disregard the other parameters of the rule.  Click the dropdown menu next to the checkbox to place this firewall rule on a time schedule. WAN Connection (Inbound) Select the WAN connection that this firewall rule should apply to. Protocol This setting specifies the protocol to be matched. Via a drop-down menu, the following protocols can be specified: • TCP • UDP • ICMP • IP  Alternatively, the Protocol Selection Tool drop-down menu can be used to automatically fill in the protocol and port number of common Internet services (e.g., HTTP, HTTPS, etc.)   After selecting an item from the Protocol Selection Tool drop-down menu, the protocol and port number remains manually modifiable. Source IP & Port This specifies the source IP address(es) and port number(s) to be matched for the firewall rule. A single address, or a network, can be specified as the Source IP & Port setting, as indicated by the following screenshot:  In addition, a single port, or a range of ports, can be specified for the Source IP & Port settings. Destination IP & Port This specifies the destination IP address(es) and port number(s) to be matched for the firewall rule. A single address, or a network, can be specified as the Destination IP & Port setting, as indicated by the following screenshot:  In addition, a single port, or a range of ports, can be specified for the Destination IP & Port settings. Action This setting specifies the action to be taken by the router upon encountering traffic that matches the both of the following: • Source IP & port • Destination IP & port With the value of Allow for the Action setting, the matching traffic passes through the router (to be routed to the destination). If the value of the Action setting is set to Deny, the matching traffic does not pass through the router (and is discarded).
 Pepwave MAX and Surf User Manual http://www.pepwave.com  121    Copyright @ 2016 Pepwave   Event Logging This setting specifies whether or not to log matched firewall events. The logged messages are shown on the page Status>Event Log. A sample message is as follows: Aug 13 23:47:44 Denied CONN=Ethernet WAN SRC=20.3.2.1  DST=192.168.1.20 LEN=48 PROTO=TCP SPT=2260 DPT=80 • CONN:  The connection where the log entry refers to • SRC:  Source IP address • DST:  Destination IP address • LEN:  Packet length • PROTO:  Protocol • SPT:  Source port • DPT:  Destination port Click Save to store your changes. To create an additional firewall rule, click Add Rule and repeat the above steps. To change a rule’s priority, simply drag and drop the rule: • Hold the left mouse button on the rule. • Move it to the desired position. • Drop it by releasing the mouse button.  Tip If the default inbound rule is set to Allow for NAT-enabled WANs, no inbound Allow firewall rules will be required for inbound port forwarding and inbound NAT mapping rules. However, if the default inbound rule is set as Deny, a corresponding Allow firewall rule will be required.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  122    Copyright @ 2016 Pepwave   19.1.2 Apply Firewall Rules to PepVpn Traffic   When this option is enabled, Outbound Firewall Rules will be applied to PepVPN traffic. To turn on this feature, click  , check the Enable check box, and press the Save button.  19.1.3 Intrusion Detection and DoS Prevention  Pepwave routers can detect and prevent intrusions and denial-of-service (DoS) attacks from the Internet. To turn on this feature, click  , check the Enable check box, and press the Save button. When this feature is enabled, the Pepwave router will detect and prevent the following kinds of intrusions and denial-of-service attacks. • Port scan o NMAP FIN/URG/PSH o Xmas tree o Another Xmas tree o Null scan o SYN/RST o SYN/FIN • SYN flood prevention • Ping flood attack prevention
 Pepwave MAX and Surf User Manual http://www.pepwave.com  123    Copyright @ 2016 Pepwave   19.2  Content Blocking   19.2.1 Application Blocking Choose applications to be blocked from LAN/PPTP/PepVPN peer clients' access, except for those on the Exempted User Groups or Exempted Subnets defined below. 19.2.2 Web Blocking Defines web site domain names to be blocked from LAN/PPTP/PepVPN peer clients' access except for those on the Exempted User Groups or Exempted Subnets defined below.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  124    Copyright @ 2016 Pepwave   If "foobar.com" is entered, any web site with a host name ending in foobar.com will be blocked, e.g. www.foobar.com, foobar.com, etc. However, "myfoobar.com" will not be blocked.  You may enter the wild card ".*" at the end of a domain name to block any web site with a host name having the domain name in the middle. If you enter "foobar.*", then "www.foobar.com", "www.foobar.co.jp", or "foobar.co.uk" will be blocked. Placing the wild card in any other position is not supported.  The device will inspect and look for blocked domain names on all HTTP traffic. Secure web (HTTPS) traffic is not supported. 19.2.3 Customized Domains Enter an appropriate website address, and the Peplink Balance will block and disallow LAN/PPTP/SpeedFusionTM peer clients to access these websites. Exceptions can be added using the instructions in Sections 20.1.3.2 and 20.1.3.3. You may enter the wild card ".*" at the end of a domain name to block any web site with a host name having the domain name in the middle. For example, If you enter "foobar.*," then "www.foobar.com," "www.foobar.co.jp," or "foobar.co.uk" will be blocked. Placing the wild card in any other position is not supported. The Peplink Balance will inspect and look for blocked domain names on all HTTP traffic. Secure web (HTTPS) traffic is not supported. 19.2.4 Exempted User Groups Check and select pre-defined user group(s) who can be exempted from the access blocking rules. User groups can be defined at QoS>User Groups section. Please refer to Section 17.1 for details. 19.2.5 Exempted Subnets With the subnet defined in the field, clients on the particular subnet(s) can be exempted from the access blocking rules. 19.2.6 URL Logging Click enable, and the enter the ip address and port (if applicable) where your remote syslog server is located.  19.3  OSPF & RIPv2 The  Peplink  Balance  supports  OSPF  and  RIPv2  dynamic  routing  protocols.  Click  the Network tab from the top bar, and then click the OSPF & RIPv2 item on the sidebar to reach the following menu:
 Pepwave MAX and Surf User Manual http://www.pepwave.com  125    Copyright @ 2016 Pepwave    OSPF Router ID  This field determines the ID of the router. By default, this is specified as the LAN IP address. If you want to specify your own ID, enter it in the Custom field. Area  This is an overview of the OSPFv2 areas you have defined. Click on the area name to configure it. To set a new area, click Add. To delete an existing area, click   .   OSPF Settings Area ID  Determine the name of your Area ID to apply to this group. Machines linked to this group will send and receive related OSPF packets, while unlinked machines will ignore it. Link Type  Choose the network type that this area will use.  Authentication Choose an authentication method, if one is used, from this drop-down menu. Available options are MD5 and Text. Enter the authentication key next to the drop-down menu. Interfaces  Determine which interfaces this area will use to listen to and deliver OSPF packets
 Pepwave MAX and Surf User Manual http://www.pepwave.com  126    Copyright @ 2016 Pepwave   To access RIPv2 settings, click  .  RIPv2 Settings Authentication Choose an authentication method, if one is used, from this drop-down menu. Available options are MD5 and Text. Enter the authentication key next to the drop-down menu. Interfaces  Determine which interfaces this group will use to listen to and deliver RIPv2 packets.  19.4  Remote User Access a Networks routed by a Peplink Balance can be remotely accessed via L2TP with IPsec or PPTP. To configure this feature, navigate to Network > Remote User Access
 Pepwave MAX and Surf User Manual http://www.pepwave.com  127    Copyright @ 2016 Pepwave    Remote User Access Settings Enable  Click the checkbox to enable Remote User Access. VPN Type  Determine whether remote devices can connect to the Balance using L2TP with IPsec or PPTP. For greater security, we recommend you connect using L2TP with IPsec. Preshared Key Enter your preshared key in the text field. Please note that remote devices will need this preshared key to access the Balance. Listen On  This setting is for specifying the WAN IP addresses where the PPTP server of the router should listen on. User Accounts This setting allows you to define the PPTP User Accounts. Click Add to input username and password to create an account. After adding the user accounts, you can click on a username to edit the account password. Click the button X to delete the account in its corresponding row.  Click the   button to switch to enters user accounts by pasting the information in.CSV format.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  128    Copyright @ 2016 Pepwave   Miscellaneous Settings The miscellaneous settings include configuration for high availability, PPTP server, service forwarding, and service passthrough. 19.5  High Availability Many Pepwave routers support high availability (HA) configurations via an open standard virtual router redundancy protocol (VRRP, RFC 3768). In an HA configuration, two Pepwave routers provide redundancy and failover in a master-slave arrangement. In the event that the master unit is down, the slave unit becomes active. High availability will be disabled automatically where there is a drop-in connection configured on a LAN bypass port.  In the diagram, the WAN ports of each Pepwave router connect to the router and to the modem. Both Pepwave routers connect to the same LAN switch via a LAN port. An elaboration on the technical details of the implementation of the virtual router redundancy protocol (VRRP, RFC 3768) by Pepwave routers follows:  In an HA configuration, the two Pepwave routers communicate with each other using VRRP over the LAN.  The two Pepwave routers broadcast heartbeat signals to the LAN at a frequency of one heartbeat signal per second.    In the event that no heartbeat signal from the master Pepwave router is received in 3 seconds (or longer) since the last heartbeat signal, the slave Pepwave router becomes active.  The slave Pepwave router initiates the WAN connections and binds to a previously configured LAN IP address.  At a subsequent point when the master Pepwave router recovers, it will once again become active.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  129    Copyright @ 2016 Pepwave    You can configure high availability at Advanced>Misc. Settings>High Availability. Interface for Master Router Interface for Slave Router  High Availability Enable  Checking this box specifies that the Pepwave router is part of a high availability configuration. Group Number This number identifies a pair of Pepwave routers operating in a high availability configuration. The two Pepwave routers in the pair must have the same Group Number value. Preferred Role This setting specifies whether the Pepwave router operates in master or slave mode. Click the corresponding radio button to set the role of the unit. One of the units in the pair must be configured as the master, and the other unit must be configured as the slave. Resume Master Role Upon Recovery This option is displayed when Master mode is selected in Preferred Role. If this option is enabled, once the device has recovered from an outage, it will take over and resume its Master role from the slave unit. Configuration Sync. This option is displayed when Slave mode is selected in Preferred Role. If this option is enabled and the Master Serial Number entered matches with the actual master unit's, the master unit will automatically transfer the configuration to this unit. Please make sure the LAN IP Address and the Subnet Mask fields are set correctly in the LAN settings page. You can refer to the Event Log for the configuration synchronization status. Master Serial Number If Configuration Sync. is checked, the serial number of the master unit is required here for the feature to work properly. Virtual IP  The HA pair must share the same Virtual IP. The Virtual IP and the LAN Administration IP must be under the same network. LAN Administration IP This setting specifies a LAN IP address to be used for accessing administration functionality. This address should be unique within the LAN. Subnet Mask  This setting specifies the subnet mask of the LAN.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  130    Copyright @ 2016 Pepwave   Important Note For Pepwave routers in NAT mode, the virtual IP (VIP) should be set as the default gateway for all hosts on the LAN segment. For example, a firewall sitting behind the Pepwave router should set its default gateway as the virtual IP instead of the IP of the master router.   In drop-in mode, no other configuration needs to be set.    Please note that the drop-in WAN cannot be configured as a LAN bypass port while it is configured for high availability.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  131    Copyright @ 2016 Pepwave   19.6  PPTP Server  Pepwave routers feature a built-in PPTP server, which enables remote computers to conveniently and securely access the local network. PPTP server settings are located at Advanced>Misc. Settings>PPTP Server. Check the box to enable PPTP server functionality. All connected PPTP sessions are displayed at Status>Client List. Please refer to Section 22.3 for details. Note that available options vary by model.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  132    Copyright @ 2016 Pepwave   PPTP Server Settings Listen On  This setting is for specifying the WAN connection(s) and IP address(es) that the PPTP server should listen on. Authentication This setting is for specifying the user database source for PPTP authentication. Three sources can be selected: Local User Accounts, LDAP Server, or RADIUS Server. Local User Accounts - User accounts are stored in the Pepwave router locally. You can add/modify/delete accounts in the User Accounts table. LDAP Server - Authenticate with an external LDAP server. This has been tested with Open LDAP servers where passwords are NTLM hashed. Active Directory is not supported. (You can choose to use RADIUS to authenticate with a Windows server.) RADIUS Server - Authenticate with an external RADIUS server. This has been tested with Microsoft Windows Internet Authentication Service and FreeRADIUS servers where passwords are NTLM hashed or in plain text. User Accounts This setting allows you to define PPTP user accounts for authentication via local user accounts. Click Add to input username and password to create an account. After adding the user accounts, you can click on a username to edit the account password. Click   to delete the account in its corresponding row. 19.7  Certificate Manager  This section allows you to assign certificates for local VPN and web admin SSL. The local keys will not be transferred to another device by any means. 19.8  Service Forwarding Service forwarding settings are located at Advanced>Misc. Settings>Service Forwarding.  Service Forwarding SMTP Forwarding When this option is enabled, all outgoing SMTP connections destined for any host at TCP port 25 will be intercepted. These connections will be redirected to a specified SMTP server and port number. SMTP server settings for each WAN can be specified
 Pepwave MAX and Surf User Manual http://www.pepwave.com  133    Copyright @ 2016 Pepwave   after selecting Enable. Web Proxy Forwarding When this option is enabled, all outgoing connections destined for the proxy server specified in Web Proxy Interception Settings will be intercepted. These connections will be redirected to a specified web proxy server and port number. Web proxy interception settings and proxy server settings for each WAN can be specified after selecting Enable. DNS Forwarding When this option is enabled, all outgoing DNS lookups will be intercepted and redirected to the built-in DNS name server. If any LAN device is using the DNS name servers of a WAN connection, you may want to enable this option to enhance the DNS availability without modifying the DNS server setting of the clients. The built-in DNS name server will distribute DNS lookups to corresponding DNS servers of all available WAN connections. In this case, DNS service will not be interrupted, even if any WAN connection is down. Custom Service Forwarding When custom service forwarding is enabled, outgoing traffic with the specified TCP port will be forwarded to a local or remote server by defining its IP address and port number.  19.8.1 SMTP Forwarding Some ISPs require their users to send e-mails via the ISP’s SMTP server. All outgoing SMTP connections are blocked except those connecting to the ISP’s. Pepwave routers support intercepting and redirecting all outgoing SMTP connections (destined for TCP port 25) via a WAN connection to the WAN’s corresponding SMTP server.  To enable the feature, select Enable under SMTP Forwarding Setup. Check Enable Forwarding for the WAN connection(s) that needs forwarding. Under SMTP Server, enter the ISP’s e-mail server host name or IP address. Under SMTP Port, enter the TCP port number for each WAN.   The Pepwave router will intercept SMTP connections. Choose a WAN port according to the outbound policy, and then forward the connection to the SMTP server if the chosen WAN has enabled forwarding. If the forwarding is disabled for a WAN connection, SMTP connections for the WAN will be simply be forwarded to the connection’s original destination. Note If you want to route all SMTP connections only to particular WAN connection(s), you should create a custom rule
 Pepwave MAX and Surf User Manual http://www.pepwave.com  134    Copyright @ 2016 Pepwave   in outbound policy (see Section 14.2).  19.8.2 Web Proxy Forwarding  When this feature is enabled, the Pepwave router will intercept all outgoing connections destined for the proxy server specified in Web Proxy Interception Settings, choose a WAN connection with reference to the outbound policy, and then forward them to the specified web proxy server and port number. Redirected server settings for each WAN can be set here. If forwarding is disabled for a WAN, web proxy connections for the WAN will be simply forwarded to the connection’s original destination. 19.8.3 DNS Forwarding  When DNS forwarding is enabled, all clients’ outgoing DNS requests will also be intercepted and forwarded to the built-in DNS proxy server.    19.8.4 Custom Service Forwarding  After clicking the enable checkbox, enter your TCP port for traffic heading to the router, and then specify the IP Address and Port of the server you wish to forward to the service to.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  135    Copyright @ 2016 Pepwave   19.9  Service Passthrough Service passthrough settings can be found at Advanced>Misc. Settings>Service Passthrough.  Some Internet services need to be specially handled in a multi-WAN environment. Pepwave routers can handle these services such that Internet applications do not notice being behind a multi-WAN router. Settings for service passthrough support are available here. Service Passthrough Support SIP Session initiation protocol, aka SIP, is a voice-over-IP protocol. The Pepwave router can act as a SIP application layer gateway (ALG) which binds connections for the same SIP session to the same WAN connection and translate IP address in the SIP packets correctly in NAT mode. Such passthrough support is always enabled, and there are two modes for selection: Standard Mode and Compatibility Mode. If your SIP server’s signal port number is non-standard, you can check the box Define custom signal ports and input the port numbers to the text boxes. H.323  With this option enabled, protocols that provide audio-visual communication sessions will be defined on any packet network and pass through the Pepwave router. FTP FTP sessions consist of two TCP connections; one for control and one for data. In a multi-WAN situation, they must be routed to the same WAN connection. Otherwise, problems will arise in transferring files. By default, the Pepwave router monitors TCP control connections on port 21 for any FTP connections and binds TCP connections of the same FTP session to the same WAN. If you have an FTP server listening on a port number other than 21, you can check Define custom control ports and enter the port numbers in the text boxes. TFTP The Pepwave router monitors outgoing TFTP connections and routes any incoming TFTP data packets back to the client. Select Enable if you want to enable TFTP passthrough support. IPsec NAT-T This field is for enabling the support of IPsec NAT-T passthrough. UDP ports 500, 4500, and 10000 are monitored by default. You may add more custom data ports that your IPsec system uses by checking Define custom ports. If the VPN contains IPsec site-to-site VPN traffic, check Route IPsec Site-to-Site VPN and choose the WAN connection
 Pepwave MAX and Surf User Manual http://www.pepwave.com  136    Copyright @ 2016 Pepwave   to route the traffic to. 19.10 GPS Forwarding Using the GPS forwarding feature, some Pepwave routers can automatically send GPS reports to a specified server. To set up GPS forwarding, navigate to Advanced>GPS Forwarding.    GPS Forwarding Enable  Check this box to turn on GPS forwarding. Server Enter the name/IP address of the server that will receive GPS data. Also specify a port number, protocol (UDP or TCP), and a report interval of between 1 and 10 seconds. Click   to save these settings. GPS Report Format  Choose from NMEA or TAIP format for sending GPS reports. NMEA Sentence Type If you’ve chosen to send GPS reports in NMEA format, select one or more sentence types for sending the data (GPRMC, GPGGA, GPVTG, GPGSA, and GPGSV). Vehicle ID  The vehicle ID will be appended in the last field of the NMEA sentence. Note that the NMEA sentence will become customized and non-standard. TAIP Sentence Type/TAIP ID (optional) If you’ve chosen to send GPS reports in TAIP format, select one or more sentence types for sending the data (PV—Position / Velocity Solution and CP—Compact Velocity Solution). You can also optionally include an ID number in the TAIP ID field.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  137    Copyright @ 2016 Pepwave   20 AP Controller The AP controller acts as a centralized controller of Pepwave AP devices. With this feature, users can customize and manage multiple APs from a single Pepwave router interface. Special Note Each Pepwave router can control a limited number of routers without additional cost. To manage more, a Full Edition license is required. Please contact your Authorized Reseller or the Peplink Sales Team for more information and pricing details.  To configure, navigate to the AP tab. 20.1  Wireless SSID This menu is the first one that appears after clicking the AP tab. This screen can also be reached by clicking AP>Wireless SSID. Note the appearance of this screen varies by model.   AP Controller AP Management The AP controller for managing Pepwave APs can be enabled by checking this box. When this option is enabled, the AP controller will wait for management connections originating from APs over the LAN on TCP and UDP port 11753. It will also wait for captive portal connections on TCP port 443. An extended DHCP option, CAPWAP Access Controller addresses (field 138), will be added to the DHCP server. A local DNS record, AP Controller, will be added to the local DNS proxy. Permitted AP Access points to manage can be specified here. If Any is selected, the AP controller will manage any AP that reports to it. If Approved List is selected, only APs with serial numbers listed in the provided text box will be managed.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  138    Copyright @ 2016 Pepwave    Current SSID information appears in the SSID section. To edit an existing SSID, click its name in the list. To add a new SSID, click Add. Note that the following settings vary by model.  SSID Settings SSID  This setting specifies the SSID of the virtual AP to be scanned by Wi-Fi clients. Enable  Select Yes to enable the virtual AP. VLAN ID This setting specifies the VLAN ID to be tagged on all outgoing packets generated from this wireless network (i.e., packets that travel from the Wi-Fi segment through the Pepwave AP One unit to the Ethernet segment via the LAN port). The default value of this setting is 0, which means VLAN tagging is disabled (instead of tagged with zero). Broadcast SSID  This setting specifies whether or not Wi-Fi clients can scan the SSID of this wireless network. Broadcast SSID is enabled by default. Data Rate A Select Auto to allow the Pepwave router to set the data rate automatically, or select Fixed and choose a rate from the displayed drop-down menu. Multicast FilterA This setting enables the filtering of multicast network traffic to the wireless SSID.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  139    Copyright @ 2016 Pepwave   Multicast RateA This setting specifies the transmit rate to be used for sending multicast network traffic. The selected Protocol and Channel Bonding settings will affect the rate options and values available here. IGMP Snooping A To allow the Pepwave router to listen to internet group management protocol (IGMP) network traffic, select this option. DHCP Option 82 A If you use a distributed DHCP server/relay environment, you can enable this option to provide additional information on the manner in which clients are physically connected to the network. Network Priority (QoS) A Select from Gold, Silver, and Bronze to control the QoS priority of this wireless network’s traffic. Layer 2 Isolation A Layer 2 refers to the second layer in the ISO Open System Interconnect model. When this option is enabled, clients on the same VLAN, SSID, or subnet are isolated to that VLAN, SSID, or subnet, which can enhance security. Traffic is passed to upper communication layer(s). By default, the setting is disabled.  Band Steering A Band steering allows the Pepwave router to steer AP clients from the 2.4GHz band to the 5GHz band for better usage of bandwidth. To make steering mandatory, select Enforce. To cause the Pepwave router to preferentially choose steering, select Prefer. The default for this setting is Disable. A - Advanced feature. Click the   button on the top right-hand corner to activate.   Security Settings Security Policy This setting configures the wireless authentication and encryption methods. Available options are Open (No Encryption), WPA/WPA2 - Personal, WPA/WPA2 – Enterprise and Static WEP.   Access Control Restricted Mode The settings allow administrator to control access using MAC address filtering. Available options are None, Deny all except listed, Accept all except listed, and RADIUS MAC Authentication.  When WPA/WPA2 - Enterprise is configured, RADIUS-based 802.1 x authentication is enabled. Under this configuration, the Shared Key option should be disabled. When using
 Pepwave MAX and Surf User Manual http://www.pepwave.com  140    Copyright @ 2016 Pepwave   this method, select the appropriate version using the V1/V2 controls. The security level of this method is known to be very high. When WPA/WPA2- Personal is configured, a shared key is used for data encryption and authentication. When using this configuration, the Shared Key option should be enabled. Key length must be between eight and 63 characters (inclusive). The security level of this method is known to be high. The configuration of Static WEP parameters enables pre-shared WEP key encryption. Authentication is not supported by this method. The security level of this method is known to be weak.   MAC Address List Connection coming from the MAC addresses in this list will be either denied or accepted based the option selected in the previous field.    RADIUS Server Settings Host  Enter the IP address of the primary RADIUS server and, if applicable, the secondary RADIUS server. Secret  Enter the RADIUS shared secret for the primary server and, if applicable, the secondary RADIUS server. Authentication Port In field, enter the UDP authentication port(s) used by your RADIUS server(s) or click the Default button to enter 1812. Accounting Port In field, enter the UDP accounting port(s) used by your RADIUS server(s) or click the Default button to enter 1813.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  141    Copyright @ 2016 Pepwave    20.2  Settings On many Pepwave models, the AP settings screen (AP>Settings) looks similar to the example below:   AP Settings AP Profile Name  This field specifies the name of this AP profile. SSID These buttons specify which wireless networks will use this AP profile. You can also select the frequencies at which each network will transmit. Please note that the Peplink Balance does not detect whether the AP is capable of transmitting at both frequencies. Instructions to transmit at unsupported frequencies will be ignored by the AP. Operating  This drop-down menu specifies the national / regional regulations which the AP should
 Pepwave MAX and Surf User Manual http://www.pepwave.com  142    Copyright @ 2016 Pepwave   Country  follow.   • If a North American region is selected, RF channels 1 to 11 will be available and the maximum transmission power will be 26 dBm (400 mW).   • If European region is selected, RF channels 1 to 13 will be available. The maximum transmission power will be 20 dBm (100 mW). NOTE: Users are required to choose an option suitable to local laws and regulations. Per FCC regulation, the country selection is not available on all models marketed in US. All US models are fixed to US channels only. Preferred Frequency These buttons determine the frequency at which access points will attempt to broadcast. This feature will only work for APs that can transmit at both 5.4GHz and 5GHz frequencies. 5 GHz Protocol  This section displays the 5 GHz protocols your APs are using. 5GHz Channel Bonding There are three options: 20 MHz, 20/40 MHz, and 40 MHz. With this feature enabled, the Wi-Fi system can use two channels at once. Using two channels improves the performance of the Wi-Fi connection.  5 GHz Channel This drop-down menu selects the 5 GHz 802.11 channel to be utilized. If Auto is set, the system will perform channel scanning based on the scheduled time set and choose the most suitable channel automatically. 2.4 GHz Protocol This section displays the 2.4 GHz protocols your APs are using. 2.4 GHz Channel Bonding There are three options: 20 MHz, 20/40 MHz, and 40 MHz. With this feature enabled, the Wi-Fi system can use two channels at once. Using two channels improves the performance of the Wi-Fi connection. 2.4 GHz Channel This drop-down menu selects the 802.11 channel to be utilized. Available options are from 1 to 11 and from 1 to 13 for the North America region and Europe region, respectively. (Channel 14 is only available when the country is selected as Japan with protocol 802.11b.) If Auto is set, the system will perform channel scanning based on the scheduled time set and choose the most suitable channel automatically. Management VLAN ID This field specifies the VLAN ID to tag to management traffic, such as AP to AP controller communication traffic. The value is 0 by default, meaning that no VLAN tagging will be applied. NOTE: change this value with caution as alterations may result in loss of connection to the AP controller. Operating Schedule Choose from the schedules that you have defined in System>Schedule. Select the schedule for the integrated AP to follow from the drop-down menu. Power BoostA With this option enabled, the AP under this profile will transmit using additional power. Please note that using this option with several APs in close proximity will lead to increased interference. Output PowerA This drop-down menu determines the power at which the AP under this profile will broadcast. When fixed settings are selected, the AP will broadcast at the specified power level, regardless of context. When Dynamic settings are selected, the AP will adjust its power level based on its surrounding APs in order to maximize performance.  The Dynamic: Auto setting will set the AP to do this automatically. Otherwise, the Dynamic: Manual setting will set the AP to dynamically adjust only of instructed to do so. If you have set Dynamic:Manual, you can go to AP>Toolbox>Auto Power Adj. to
 Pepwave MAX and Surf User Manual http://www.pepwave.com  143    Copyright @ 2016 Pepwave   give your AP further instructions. Max number of ClientsA This field determines the maximum clients that can be connected to APs under this profile.  Client Signal Strength ThresholdA This field determines that maximum signal strength each individual client will receive. The measurment unit is megawatts. Beacon RateA This drop-down menu provides the option to send beacons in different transmit bit rates. The bit rates are 1Mbps, 2Mbps, 5.5Mbps, 6Mbps, and 11Mbps. Beacon IntervalA This drop-down menu provides the option to set the time between each beacon send. Available options are 100ms, 250ms, and 500ms. DTIMA This field provides the option to set the frequency for beacon to include delivery traffic indication messages (DTIM). The interval unit is measured in milliseconds. RTS ThresholdA This field provides the option to set the minimum packet size for the unit to send an RTS using the RTS/CTS handshake. Setting 0 disables this feature. Fragmentation ThresholdA Determines the maximum size (in bytes) that each packet fragment will be broken down into. Set 0 to disable fragmentation. Distance/Time ConverterA Select the distance you want your Wi-Fi to cover in order to adjust the below parameters. Default values are recommended. Slot TimeA This field provides the option to modify the unit wait time before it transmits. The default value is 9μs. ACK TimeoutA This field provides the option to set the wait time to receive acknowledgement packet before doing retransmission. The default value is 48μs. Frame AggregationA With this feature enabled, throughput will be increased by sending two or more data frames in a single transmission. Frame Length  This field is only available when Frame Aggregation is enabled. It specifies the frame length for frame aggregation. By default, it is set to 50000.  A - Advanced feature. Click the   button on the top right-hand corner to activate.  Web Administration Settings
 Pepwave MAX and Surf User Manual http://www.pepwave.com  144    Copyright @ 2016 Pepwave   Enable  Check the box to allow the Pepwave router to manage the web admin access information of the AP. Web Access Protocol These buttons specify the web access protocol used for accessing the web admin of the AP. The two available options are HTTP and HTTPS. Management Port This field specifies the management port used for accessing the device. HTTP to HTTPS Redirection This option will be available if you have chosen HTTPS as the Web Access Protocol. With this enabled, any HTTP access to the web admin will redirect to HTTPS automatically. Admin User Name This field specifies the administrator username of the web admin. It is set as admin by default. Admin Password This field allows you to specify a new administrator password. You may also click the Generate button and let the system generate a random password automatically.          Navigating to AP>Settings on some Pepwave models displays a screen similar to the one shown below:
 Pepwave MAX and Surf User Manual http://www.pepwave.com  145    Copyright @ 2016 Pepwave   Wi-Fi Radio Settings Operating Country  This option sets the country whose regulations the Pepwave router follows.  Wi-Fi Antenna  Choose from the router's internal or optional external antennas, if so equipped.  Important Note Per FCC regulations, the country selection is not available on all models marketed in the US. All US models are fixed to US channels only.  Wi-Fi AP Settings Protocol This option allows you to specify whether 802.11b and/or 802.11g client association requests will be accepted. Available options are 802.11ng and 802.11na. By default, 802.11ng is selected.  Channel  This option allows you to select which 802.11 RF channel will be used. Channel 1 (2.412 GHz) is selected by default.  Channel Width  Auto (20/40 MHz) and 20 MHz are available. The default setting is Auto (20/40 MHz), which allows both widths to be used simultaneously.  Output Power This option is for specifying the transmission output power for the Wi-Fi AP. There are 4 relative power levels available – Max, High, Mid, and Low. The actual output power will be bound by the regulatory limits of the selected country. Beacon RateA This option is for setting the transmit bit rate for sending a beacon. By default, 1Mbps is selected.  Beacon IntervalA This option is for setting the time interval between each beacon. By default, 100ms is selected.  DTIMA This field allows you to set the frequency for the beacon to include a delivery traffic indication message. The interval is measured in milliseconds. The default value is set to 1 ms. Slot TimeA This field is for specifying the wait time before the Surf SOHO transmits a packet. By default, this field is set to 9 µs.  ACK TimeoutA This field is for setting the wait time to receive an acknowledgement packet before performing a retransmission. By default, this field is set to 48 µs. Frame AggregationA This option allows you to enable frame aggregation to increase transmission throughput. Guard IntervalA This setting allows choosing a short or long guard period interval for your transmissions. A - Advanced feature, please click the   button on the top right-hand corner to activate. 20.3  Toolbox Tools for managing firmware packs can be found at AP>Toolbox.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  146    Copyright @ 2016 Pepwave    Firmware Packs Here, you can manage the firmware of your AP. Clicking on   will result in information regarding each firmware pack. To receive new firmware packs, you can click Check for Updates to download new packs, or you can click Manual Upload to manually upload a firmware pack. Click Default to define which firmware pack is default.           21 System Settings 21.1  Admin Security There are two types of user accounts available for accessing the web admin: admin and user. They represent two user levels: the admin level has full administration access, while the user level is read-only. The user level can access only the device's status information; users cannot make any changes on the device.    Admin account UI  User account UI
 Pepwave MAX and Surf User Manual http://www.pepwave.com  147    Copyright @ 2016 Pepwave   A web login session will be logged out automatically when it has been idle longer than the Web Session Timeout. Before the session expires, you may click the Logout button in the web admin to exit the session. 0 hours 0 minutes signifies an unlimited session time. This setting should be used only in special situations, as it will lower the system security level if users do not log out before closing the browser. The default is 4 hours, 0 minutes.  For security reasons, after logging in to the web admin Interface for the first time, it is recommended to change the administrator password. Configuring the administration interface to be accessible only from the LAN can further improve system security. Administrative settings configuration is located at System>Admin Security.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  148    Copyright @ 2016 Pepwave   Admin Settings Router Name This field allows you to define a name for this Pepwave router. By default, Router Name is set as MAX_XXXX or Surf_SOHO_XXXX, where XXXX refers to the last 4 digits of the unit’s serial number. Admin User Name  Admin User Name is set as admin by default, but can be changed, if desired. Admin Password  This field allows you to specify a new administrator password. Confirm Admin Password  This field allows you to verify and confirm the new administrator password. Read-only User Name  Read-only User Name is set as user by default, but can be changed, if desired. User Password This field allows you to specify a new user password. Once the user password is set, the read-only user feature will be enabled. Confirm User Password  This field allows you to verify and confirm the new user password. Web Session Timeout This field specifies the number of hours and minutes that a web session can remain idle before the Pepwave router terminates its access to the web admin interface. By default, it is set to 4 hours. Authentication by RADIUS With this box is checked, the web admin will authenticate using an external RADIUS server. Authenticated users are treated as either "admin" with full read-write permission or “user” with read-only access. Local admin and user accounts will be disabled. When the device is not able to communicate with the external RADIUS server, local accounts will be enabled again for emergency access. Additional authentication options will be available once this box is checked. Auth Protocol  This specifies the authentication protocol used. Available options are MS-CHAP v2 and PAP. Auth Server  This specifies the access address and port of the external RADIUS server. Auth Server Secret  This field is for entering the secret key for accessing the RADIUS server. Auth Timeout  This option specifies the time value for authentication timeout. Accounting Server  This specifies the access address and port of the external accounting server. Accounting Server Secret  This field is for entering the secret key for accessing the accounting server. Network Connection This option is for specifying the network connection to be used for authentication. Users can choose from LAN, WAN, and VPN connections. CLI SSH   The CLI (command line interface) can be accessed via SSH. This field enables CLI
 Pepwave MAX and Surf User Manual http://www.pepwave.com  149    Copyright @ 2016 Pepwave   support. For additional information regarding CLI, please refer to Section 21.16. CLI SSH Port  This field determines the port on which clients can access CLI SSH. CLI SSH Access This menu allows you to choose between granting access to LAN and WAN clients, or to LAN clients only.  Security This option is for specifying the protocol(s) through which the web admin interface can be accessed: • HTTP • HTTPS  • HTTP/HTTPS Web Admin Port This field is for specifying the port number on which the web admin interface can be accessed. Web Admin Access This option is for specifying the network interfaces through which the web admin interface can be accessed: • LAN only  • LAN/WAN If LAN/WAN is chosen, the WAN Connection Access Settings form will be displayed.   WAN Connection Access Settings Allowed Source IP Subnets This field allows you to restrict web admin access only from defined IP subnets. • Any - Allow web admin accesses to be from anywhere, without IP address restriction. • Allow access from the following IP subnets only - Restrict web admin access only from the defined IP subnets.  When this is chosen, a text input area will be displayed beneath: The allowed IP subnet addresses should be entered into this text area. Each IP subnet must be in form of w.x.y.z/m, where w.x.y.z is an IP address (e.g., 192.168.0.0), and m is the subnet mask in CIDR format, which is between 0 and 32 inclusively (For example, 192.168.0.0/24). To define multiple subnets, separate each IP subnet one in a line. For example:
 Pepwave MAX and Surf User Manual http://www.pepwave.com  150    Copyright @ 2016 Pepwave   • 192.168.0.0/24 • 10.8.0.0/16 Allowed WAN IP Address(es) This is to choose which WAN IP address(es) the web server should listen on.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  151    Copyright @ 2016 Pepwave   21.2  Firmware Pepwave router firmware is upgradeable through the web admin interface. Firmware upgrade functionality is located at System>Firmware.  There are two ways to upgrade the unit. The first method is through an online download. The second method is to upload a firmware file manually. To perform an online download, click on the Check for Firmware button. The Pepwave router will check online for new firmware. If new firmware is available, the Pepwave router will automatically download the firmware. The rest of the upgrade process will be automatically initiated. You may also download a firmware image from the Peplink website and update the unit manually. To update using a firmware image, click Choose File to select the firmware file from the local computer, and then click Manual Upgrade to send the firmware to the Pepwave router. It will then automatically initiate the firmware upgrade process. Please note that all Peplink devices can store two different firmware versions in two different partitions. A firmware upgrade will always replace the inactive partition. If you want to keep the inactive firmware, you can simply reboot your device with the inactive firmware and then perform the firmware upgrade.  Important Note The firmware upgrade process may not necessarily preserve the previous configuration, and the behavior varies on a case-by-case basis. Consult the release notes for the particular firmware version before installing. Do not disconnect the power during firmware upgrade process. Do not attempt to upload a non-firmware file or a firmware file that is not supported by Peplink. Upgrading the Pepwave router with an invalid firmware file will damage the unit and may void the warranty.  Important Note If the firmware is rolled back from 5.x to 4.x, the configurations will be lost.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  152    Copyright @ 2016 Pepwave   21.3  Time Time Settings enables the system clock of the Pepwave router to be synchronized with a specified time server. Time settings are located at System>Time.  Time Settings Time Zone This specifies the time zone (along with the corresponding Daylight Savings Time scheme). The Time Zone value affects the time stamps in the Pepwave router’s event log and e-mail notifications. Check Show all to show all time zone options. Time Server  This setting specifies the NTP network time server to be utilized by the Pepwave router. 21.4  Schedule Enable and disable different functions (such as WAN connections, outbound policy, and firewalls at different times, based on a user-scheduled configuration profile. The settings for this are located at System > Schedule    Enable scheduling, and then click on your schedule name or on the New Schedule button to begin.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  153    Copyright @ 2016 Pepwave     Edit Schedule Profile Enabling  Click this checkbox to enable this schedule profile. Note that if this is disabled, then any associated features will also have their scheduling disabled. Name  Enter your desired name for this particular schedule profile. Schedule  Click the drop-down menu to choose pre-defined schedules as your starting point. Please note that upon selection, previous changes on the schedule map will be deleted.  Schedule Map  Click on the desired times to enable features at that time period. You can hold your mouse for faster entry.  21.5  Email Notification  Email notification functionality provides a system administrator with up-to-date information on network status. The settings for configuring email notifications are found at System>Email Notification.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  154    Copyright @ 2016 Pepwave    Email Notification Settings Email Notification This setting specifies whether or not to enable email notification. If Enable is checked, the Pepwave router will send email messages to system administrators when the WAN status changes or when new firmware is available. If  Enable is not checked, email notification is disabled and the Pepwave router will not send email messages. SMTP Server  This setting specifies the SMTP server to be used for sending email. If the server requires authentication, check Require authentication. SSL Encryption Check the box to enable SMTPS.  When the box is checked, SMTP Port will be changed to 465 automatically. SMTP Port This field is for specifying the SMTP port number. By default, this is set to 25; when SSL Encryption is checked, the default port number will be set to 465. You may customize the port number by editing this field. Click Default to restore the number to its default setting.  SMTP User Name / Password This setting specifies the SMTP username and password while sending email. These options are shown only if Require authentication is checked in the SMTP Server setting. Confirm SMTP Password  This field allows you to verify and confirm the new administrator password. Sender’s Email Address  This setting specifies the email address the Pepwave router will use to send reports. Recipient’s Email Address This setting specifies the email address(es) to which the Pepwave router will send email notifications. For multiple recipients, separate each email addresses using the enter key.  After you have finished setting up email notifications, you can click the Test Email Notification button to test the settings before saving. After Test Email Notification is
 Pepwave MAX and Surf User Manual http://www.pepwave.com  155    Copyright @ 2016 Pepwave   clicked, you will see this screen to confirm the settings:  Click Send Test Notification to confirm. In a few seconds, you will see a message with detailed test results.   21.6  Event Log Event log functionality enables event logging at a specified remote syslog server. The settings for configuring the remote system log can be found at System>Event Log.  Event Log Settings Remote Syslog This setting specifies whether or not to log events at the specified remote syslog server. Remote Syslog Host  This setting specifies the IP address or hostname of the remote syslog server.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  156    Copyright @ 2016 Pepwave   Push Events The Pepwave router can also send push notifications to mobile devices that have our Mobile Router Utility installed. Check the box to activate this feature.   For more information on the Router Utility, go to: www.peplink.com/products/router-utility
 Pepwave MAX and Surf User Manual http://www.pepwave.com  157    Copyright @ 2016 Pepwave   21.7  SNMP SNMP or simple network management protocol is an open standard that can be used to collect information about the Pepwave router. SNMP configuration is located at System>SNMP.  SNMP Settings SNMP Device Name  This field shows the router name defined at System>Admin Security. SNMP Port  This option specifies the port which SNMP will use. The default port is 161. SNMPv1  This option allows you to enable SNMP version 1. SNMPv2  This option allows you to enable SNMP version 2. SNMPv3  This option allows you to enable SNMP version 3.  To add a community for either SNMPv1 or SNMPv2, click the Add SNMP Community button in the Community Name table, upon which the following screen is displayed:
 Pepwave MAX and Surf User Manual http://www.pepwave.com  158    Copyright @ 2016 Pepwave    SNMP Community Settings Community Name  This setting specifies the SNMP community name. Allowed Source Subnet Address This  setting  specifies  a  subnet  from  which  access  to  the  SNMP server  is  allowed.  Enter subnet address here (e.g., 192.168.1.0) and select the appropriate subnet mask. To define a user name for SNMPv3, click Add SNMP User in the SNMPv3 User Name table, upon which the following screen is displayed: SNMPv3 User Settings User Name  This setting specifies a user name to be used in SNMPv3. Authentication Protocol This setting specifies via a drop-down menu one of the following valid authentication protocols:  • NONE • MD5  • SHA When MD5 or SHA is selected, an entry field will appear for the password. Privacy Protocol This setting specifies via a drop-down menu one of the following valid privacy protocols:  • NONE  • DES When DES is selected, an entry field will appear for the password.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  159    Copyright @ 2016 Pepwave   21.8  InControl  InControl is a cloud-based service which allows you to manage all of your Peplink and Pepwave devices with one unified system. With it, you can generate reports, gather statistics, and configure your devices automatically. All of this is now possible with InControl. When this check box is checked, the device's status information will be sent to the Peplink InControl system. This device's usage data and configuration will be sent to the system if you enable the features in the system. Alternately, you could also privately host InControl. Simply check the box beside the “Privately Host InControl” open, and enter the IP Address of your InControl Host. You can sign up for an InControl account at https://incontrol2.peplink.com/. You can register your devices under the account, monitor their status, see their usage reports, and receive offline notifications.                  21.9  Configuration
 Pepwave MAX and Surf User Manual http://www.pepwave.com  160    Copyright @ 2016 Pepwave   Backing up Pepwave router settings immediately after successful completion of initial setup is strongly recommended. The functionality to download and upload Pepwave router settings is found at System>Configuration. Note that available options vary by model.  Configuration Restore Configuration to Factory Settings The Restore Factory Settings button is to reset the configuration to factory default settings. After clicking the button, you will need to click the Apply Changes button on the top right corner to make the settings effective. Download Active Configurations Click Download to backup the current active settings.  Upload Configurations To restore or change settings based on a configuration file, click Choose File to locate the configuration file on the local computer, and then click Upload. The new settings can then be applied by clicking the Apply Changes button on the page header, or you can cancel the procedure by pressing discard on the main page of the web admin interface. Upload Configurations from High Availability Pair In a high availability (HA) configuration, a Pepwave router can quickly load the configuration of its HA counterpart. To do so, click the Upload button. After loading the settings, configure the LAN IP address of the Pepwve router so that it is different from the HA counterpart.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  161    Copyright @ 2016 Pepwave   21.10 Feature Add-ons Some Pepwave routers have features that can be activated upon purchase. Once the purchase is complete, you will receive an activation key. Enter the key in the Activation Key field, click Activate, and then click Apply Changes.   21.11 Reboot This page provides a reboot button for restarting the system. For maximum reliability, the Pepwave router can equip with two copies of firmware. Each copy can be a different version. You can select the firmware version you would like to reboot the device with. The firmware marked with (Running) is the current system boot up firmware. Please note that a firmware upgrade will always replace the inactive firmware partition.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  162    Copyright @ 2016 Pepwave   21.12  Ping The ping test tool sends pings through a specified Ethernet interface or a SpeedFusionTM VPN connection. You can specify the number of pings in the field Number of times, to a maximum number of 10 times. Packet Size can be set to a maximum of 1472 bytes. The ping utility is located at System>Tools>Ping, illustrated below:  Tip A system administrator can use the ping utility to manually check the connectivity of a particular LAN/WAN connection.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  163    Copyright @ 2016 Pepwave   21.13  Traceroute Test The traceroute test tool traces the routing path to the destination through a particular Ethernet interface or a SpeedFusionTM connection. The traceroute test utility is located at System>Tools>Traceroute.  Tip A system administrator can use the traceroute utility to analyze the connection path of a LAN/WAN connection.  21.14  PepVPN Test The PepVPN Test tool can help to test the throughput between different VPN peers. You can define the Test Type, Direction, and Duration of the test, and press Go! to perform the throughput test. The VPN test utility is located at System>Tools>PepVPN Test, illustrated as follows:
 Pepwave MAX and Surf User Manual http://www.pepwave.com  164    Copyright @ 2016 Pepwave   21.15 Wake-on-LAN Peplink routers can send  special “magic  packets” to  any client specified from the Web UI. To access this feature, navigate to System > Tools > Wake-on-LAN    Select a client from the drop-down list and click Send to send a “magic packet”  21.16 CLI (Command Line Interface Support) The CLI (command line interface) can be accessed via SSH. This field enables CLI support. The below settings specify which TCP port and which interface(s) should accept remote SSH CLI access. The user name and password used for remote SSH CLI access are the same as those used for web admin access.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  165    Copyright @ 2016 Pepwave   22 Status 22.1  Device System information is located at Status>Device.   System Information Router Name  This is the name specified in the Router Name field located at System>Admin Security.  Model  This shows the model name and number of this device.  Product Code  If your model uses a product code, it will appear here. Hardware Revision  This shows the hardware version of this device. Serial Number  This shows the serial number of this device. Firmware  This shows the firmware version this device is currently running. PepVPN Version  This shows the current PepVPN version. Modem Support Version This shows the modem support version. For a list of supported modems, click Modem Support List. Host Name  The host name assigned to the Pepwave router appears here. Uptime  This shows the length of time since the device has been rebooted.  System Time  This shows the current system time. Diagnostic Report  The Download link is for exporting a diagnostic report file required for system investigation.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  166    Copyright @ 2016 Pepwave   Remote Assistance  Click Turn on to enable remote assistance.   The second table shows the MAC address of each LAN/WAN interface connected. To view your device’s End User License Agreement (EULA), click  . Important Note If you encounter issues and would like to contact the Pepwave Support Team (http://www.pepwave.com/contact/), please download the diagnostic report file and attach it along with a description of your issue. In Firmware 5.1 or before, the diagnostic report file can be obtained at System>Reboot. 22.1.1 GPS Data The MAX HD2 and HD2 IP67 automatically store up to seven days of GPS location data in GPS eXchange format (GPX). To review this data using third-party applications, click Status>Device and then download your GPX file. The Pepwave MAX BR1, HD2, and HD2 IP67 export real-time location data in NMEA format through the LAN IP address at TCP port 60660. It is accessible from the LAN or over a SpeedFusion connection. To access the data via a virtual serial port, install a virtual serial port driver. Visit http://www.peplink.com/index.php?view=faq&id=294 to download the driver.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  167    Copyright @ 2016 Pepwave   22.2  Active Sessions Information on active sessions can be found at Status>Active Sessions>Overview.  This screen displays the number of sessions initiated by each application. Click on each service listing for additional information. This screen also indicates the number of sessions initiated by each WAN port. In addition, you can see which clients are initiating the most sessions.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  168    Copyright @ 2016 Pepwave   You can also perform a filtered search for specific sessions. You can filter by subnet, port, protocol, and interface. To perform a search, navigate to Status>Active Sessions>Search.  This Active Sessions section displays the active inbound/outbound sessions of each WAN connection on the Pepwave router. A filter is available to sort active session information. Enter a keyword in the field or check one of the WAN connection boxes for filtering.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  169    Copyright @ 2016 Pepwave   22.3  Client List The client list table is located at Status>Client List. It lists DHCP and online client IP addresses, names (retrieved from the DHCP reservation table or defined by users), current download and upload rate, and MAC address.  Clients can be imported into the DHCP reservation table by clicking the   button on the right. You can update the record after import by going to Network>LAN.  If the PPTP server (see Section 19.2), SpeedFusionTM (see Section 12.1), or AP controller (see Section 20) is enabled, you may see the corresponding connection name listed in the Name field.  22.4  WINS Client The WINS client list table is located at Status>WINS Client.      The WINS client table lists the IP addresses and names of WINS clients. This option will only be available when you have enabled the WINS server (navigation: Network>Interfaces>LAN). The names of clients retrieved will be automatically matched into the Client List (see previous section). Click Flush All to flush all WINS client records.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  170    Copyright @ 2016 Pepwave    22.5  UPnP / NAT-PMP The table that shows the forwarded ports under UPnP and NAT-PMP protocols is located at Status>UPnP/NAT-PMP. This section appears only if you have enabled UPnP / NAT-PMP as mentioned in Section 16.1.1.  Click   to delete a single UPnP / NAT-PMP record in its corresponding row. To delete all records, click Delete All on the right-hand side below the table. Important Note UPnP / NAT-PMP records will be deleted immediately after clicking the button   or Delete All, without the need to click Save or Confirm.  22.6  SpeedFusion Status Current SpeedFusionTM status information is located at Status>SpeedFusionTM. Details about SpeedFusionTM connection peers appears as below:    Click on the corresponding peer name to explore the WAN connection(s) status and subnet information of each VPN peer.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  171    Copyright @ 2016 Pepwave    Click the   button for a chart displaying real-time throughput, latency, and drop-rate information for each WAN connection.   When pressing the   button, the following menu will appear:
 Pepwave MAX and Surf User Manual http://www.pepwave.com  172    Copyright @ 2016 Pepwave      After clicking the icon, the following menu appears:    Select the L2 protocol (TCP/UDP), direction, and duration and click the Start button to begin the general throughput test.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  173    Copyright @ 2016 Pepwave     The bandwidth bonding feature of PepVPN occurs when multiple WAN lines from one end merge with multiple WAN lines from the other end. For this to happen, each WAN line needs to form a connection with all the WAN lines on the opposite end. The function of the PepVPN analyzer is to report the throughput, packet loss, and latency of all possible combinations of connections. Please note that the PepVPN Analyzer will temporarily interrupt VPN connectivity and will restore after test.  After clicking the icon, the analyzer will require several minutes to perform its analysis depending the number of WAN links in the SpeedFusionTM Tunnel. Once the test the complete, the report will appear:    "O" indicates that specific WAN / Tunnel is active for that particular test.  "Tx Avg." is the averaged throughput across the full 10 seconds time, while "Tx Max." is the averaged throughput of the fastest 30% of time.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  174    Copyright @ 2016 Pepwave   22.7  Event Log Event log information is located at Status>Event Log.  The log section displays a list of events that has taken place on the Pepwave router. Check Auto Refresh to refresh log entries automatically. Click the Clear Log button to clear the log.  22.8  Bandwidth This section shows bandwidth usage statistics and is located at Status>Bandwidth. Bandwidth usage at the LAN while the device is switched off (e.g., LAN bypass) is neither recorded nor shown.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  175    Copyright @ 2016 Pepwave   22.8.1 Real-Time The Data transferred since installation table indicates how much network traffic has been processed by the device since the first bootup. The Data transferred since last reboot table indicates how much network traffic has been processed by the device since the last bootup.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  176    Copyright @ 2016 Pepwave   22.8.2 Hourly This page shows the hourly bandwidth usage for all WAN connections, with the option of viewing each individual connection. Select the desired connection to check from the drop-down menu.            22.8.3 Daily
 Pepwave MAX and Surf User Manual http://www.pepwave.com  177    Copyright @ 2016 Pepwave   This page shows the daily bandwidth usage for all WAN connections, with the option of viewing each individual connection.  Select the connection to check from the drop-down menu. If you have enabled the Bandwidth Monitoring feature, the Current Billing Cycle table for that WAN connection will be displayed. Click on a date to view the client bandwidth usage of that specific date. This feature is not available if you have selected to view the bandwidth usage of only a particular WAN connection. The scale of the graph can be set to display megabytes (MB) or gigabytes (GB).  All WAN Daily Bandwidth Usage
 Pepwave MAX and Surf User Manual http://www.pepwave.com  178    Copyright @ 2016 Pepwave   22.8.4 Monthly This page shows the monthly bandwidth usage for each WAN connection. If you have enabled the Bandwidth Monitoring feature, you can check the usage of each particular connection and view the information by Billing Cycle or by Calendar Month. Click the first two rows to view the client bandwidth usage in the last two months. This feature is not available if you have chosen to view the bandwidth of an individual WAN connection. The scale of the graph can be set to display megabytes (MB) or gigabytes (GB).  All WAN Monthly Bandwidth Usage
 Pepwave MAX and Surf User Manual http://www.pepwave.com  179    Copyright @ 2016 Pepwave    Ethernet WAN Monthly Bandwidth Usage Tip By default, the scale of data size is in MB. 1GB equals 1024MB.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  180    Copyright @ 2016 Pepwave   Appendix A. Restoration of Factory Defaults To restore the factory default settings on a Pepwave router, follow the steps below:  1. Locate the reset button on the front or back panel of the Pepwave router. 2. With a paper clip, press the reset button and hold it for at least 10 seconds, until the unit reboots itself.  After the Pepwave router finishes rebooting, the factory default settings will be restored.  Important Note All previous configurations and bandwidth usage data will be lost after restoring factory default settings. Regular backup of configuration settings is strongly recommended.
Pepwave MAX and Surf User Manual http://www.pepwave.com  181   Copyright @ 2016 Pepwave Appendix B: Declaration 1. The device supports time division technology2. Federal Communication Commission and Industry Canada InterferenceStatementThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. IMPORTANT NOTE FCC Radiation Exposure Statement (for MAX BR1 mini) This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. FCC Radiation Exposure Statement (for MAX Hotspot / HD2 IP67/ BR1/ Surf SOHO) This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC Radiation Exposure Statement (for MAX On-The-Go) This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
Pepwave MAX and Surf User Manual http://www.pepwave.com  182   Copyright @ 2016 Pepwave 1. 20cm minimum when the product is operated alone without co-transmitting with aplug-in 3G USB dongle device.2. 65cm minimum when the product is operated with a plug-in 3G USB device whichhas maximum of 7W ERP output power.3. For co-transmission scenario which is not covered above, please consult the RFtechnician or device supplier.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination.
Pepwave MAX and Surf User Manual http://www.pepwave.com  183   Copyright @ 2016 Pepwave Industry Canada Statement (for MAX Hotspot/ Surf SOHO/ MAX HD2 / MAX BR1 mini) This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2)  this  device  must  accept  any  interference,  including  interference  that  may  cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout  brouillage  radioélectrique  subi,  même  si  le  brouillage  est  susceptible  d'en compromettre le fonctionnement. To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons. Mise  en  garde_:  Pour  assurer  la  conformité  aux  directives  relatives  à  l'exposition  aux fréquences radio, le jouet doit êtreplacé à au moins 20_cm des personnes à proximité. Caution : (i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; (ii) the maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate; and  (iii) Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  184    Copyright @ 2016 Pepwave    Avertissement: (i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; (ii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5725 à 5 850 MHz) doit être conforme à la limite de la p.i.r.e. spécifiée pour l'exploitation point à point et l’exploitation non point à point, selon le cas;  (iii) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. Radiation Exposure Statement: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.  Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.   3. CE Statement for Pepwave Routers Europe – EU Declaration of Conformity This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R&TTE Directive 1999/5/EC:  - EN 60950-1: 2006 + A11 : 2009+A1 : 2010+ A12: 2011 Safety of Information Technology Equipment  - EN50385 : 2002 / Article 3(1)(a) Product standard to demonstrate the compliance of radio base stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related to human exposure to radio frequency electromagnetic fields (110MHz - 40 GHz) - General public
 Pepwave MAX and Surf User Manual http://www.pepwave.com  185    Copyright @ 2016 Pepwave    EN 300 328 V1.7.1: 2006 Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive  - EN 301 908-1 V5.2.1:  2011 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS), Repeaters and User Equipment (UE) for IMT-2000 Third-Generation cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and common requirements, covering essential requirements of article 3.2 of the R&TTE Directive  - EN 301 511 V9.0.2: 2003 Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC)  - EN 301 489-1 V1.9.2: 2008 Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements  - EN 301 489-7 V1.3.1: 2005 ElectroMagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment ad services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)  - EN 301 489-17 V2.2.1: 2012 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment   - EN 301 489-24 V1.5.1: 2010 Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment 0081  Česky [Czech] [Jméno výrobce] tímto prohlašuje, že tento [typ zařízení] je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  186    Copyright @ 2016 Pepwave   Dansk [Danish] Undertegnede [fabrikantens navn] erklærer herved, at følgende udstyr [udstyrets typebetegnelse] overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch [German] Hiermit erklärt [Name des Herstellers], dass sich das Gerät [Gerätetyp] in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian] Käesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tüüp = type of equipment] vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English  Hereby, [name of manufacturer], declares that this [type of equipment] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español [Spanish] Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική [Greek] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [name of manufacturer] ∆ΗΛΩΝΕΙ ΟΤΙ [type of equipment] ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ Ο∆ΗΓΙΑΣ 1999/5/ΕΚ. Français [French] Par la présente [nom du fabricant] déclare que l'appareil [type d'appareil] est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Italiano [Italian] Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski [Latvian] Ar šo [name of manufacturer  / izgatavotāja nosaukums] deklarē, ka [type of equipment / iekārtas tips] atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Lietuvių [Lithuanian]  Šiuo [manufacturer name] deklaruoja, kad šis [equipment type] atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlands [Dutch] Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Malti [Maltese] Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Magyar [Hungarian] Alulírott, [gyártó neve] nyilatkozom, hogy a [... típus]megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Polski [Polish] Niniejszym [nazwa producenta] oświadcza, że [nazwa wyrobu] jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. Português [Portuguese] [Nome do fabricante] declara que este [tipo de equipamento] está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.
 Pepwave MAX and Surf User Manual http://www.pepwave.com  187    Copyright @ 2016 Pepwave   Slovensko [Slovenian] [Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. Slovensky [Slovak] [Meno výrobcu] týmto vyhlasuje, že [typ zariadenia]spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish] [Valmistaja = manufacturer] vakuuttaa täten että [type of equipment = laitteen tyyppimerkintä] tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Svenska [Swedish] Härmed intygar [företag] att denna [utrustningstyp] står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.  4. NCC for Pepwave Routers  For MAX Transit  WLAN [ ] MPE 1mW/cm2  24 cm    [ ] (1)          (LTE900/LTE1800)  :
   Contact Us:  Sales http://www.pepwave.com/contact/sales/  Support http://www.pepwave.com/contact/  Business Development and Partnerships http://www.pepwave.com/partners/channel-

Navigation menu