Planet Technology FT807 POF Converter User Manual EM FT807

Planet Technology Corporation POF Converter EM FT807

Users Manual

     10/100Base-TX to 100Base-FX SMI Fast Ethernet Converter  FT-807  User’s Manual
Trademarks Copyright  c  PLANET Technology Corp. 2005. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose. PLANET has made every effort to ensure that this User’s Manual is accurate; PLANET disclaims liability for any inaccuracies or omissions that may have occurred. Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User’s Manual, at any time without notice. If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and suggestions. FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at whose own expense. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). CE Mark Warning This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal         waste and have to collect such WEEE separately.
Revision PLANET Fast Ethernet Converter User’s Manual FOR MODEL: FT-807 Rev: 1.1(December, 2005) Part No. 2010-AA3330-001
Table of Content Chapter 1 Introduction .................................................................... 5 1.1 Product Description .......................................................... 5 1.2 Packet Contents ............................................................... 5 1.3 Technical Specification ..................................................... 5 1.4 Product Outlook................................................................ 6 1.5 Duplex Mode Setting ........................................................ 6 1.6 Power information ............................................................ 7 Chapter 2 Installation ...................................................................... 8 Appendix A: RJ-45 pin assignment and cable system.................... 9 A.1 10/100Mbps, 10/100Base-TX .......................................... 9 A.2 100Mbps, 100Base-FX, SMI type connector ................. 10
Chapter 1 Introduction The  PLANET  FT-807  is  a  10/100Base-TX  shielded  twisted  pair  (STP)  to  Fast Ethernet  100Base-FX  fiber  converter.  It  supports  full-duplex  operations  at  its fiber-optic interface in the form factor of SMI (Small Multimedia Interface) interface. The  converter  auto-adapts  to  the  highest  level  of  performance  supported  by  the device connected to the STP port. 1.1 Product Description The SMI (small multimedia interface) is one kind of POF (plastic optic fiber) interface that can suitable for low-cost and high-speed data transmission. The SMI patch cord meets the IEEE 1394b specification that can transmit data at S200 (250Mbps) speed for  50  meters,  the  distance  range  of  TP  port  is  100  meters.  It  will  make  the  new generation multimedia life more possible and easy installation. 1.2 Packet Contents Your FT-807 carton should contain following items:   The Fast Ethernet Media Converter. AC to DC Power Adapter (Output: 5V DC, 2A max). This User’s Manual. If any item is found missing or damaged, please contact your local reseller from whom you purchased your Fast Ethernet Converter. 1.3 Technical Specification Standard  IEEE 802.3u, 10/100Base-TX and 100Base-FX TP Connector  RJ-45 port (Auto-MDI/MDI-X) Twisted Pair, EIA568 Fiber Connector  SMI POF port (multi-mode), 650nm wavelength Data Rate  10/100Mbps (TP) ; Auto-Negotiation for duplex mode 100Mbps (FX) ; full-duplex mode TP Cable  4 pair Cat. 3 or 5 UTP, up to 100m Fiber Cable  IEEE 1394b SMI Patch cord (0.98mm /1mm), up to 50m LED indicators  PWR, TP. POF Dimensions  86 x 62 x 23 mm (W x D x H) Power Requirement  5V DC, 2A
 1.4 Product Outlook       LED Definition  POF: Lights to indicate the SMI connection is established. TP: Lights to indicate the TP connection is established. PWR: Lights to indicate the converter is powered.  1.5 Duplex Mode Setting The TP port of FT-807 supports duplex mode detection by auto-negotiation (A-N). The following is the duplex mode parameters: Fast Ethernet Device  FT-807 Duplex Mode Support Ethernet/Fast Ethernet Hub  Half-Duplex Ethernet / Fast Ethernet Switch (without A-N) Half-Duplex Fast Ethernet Devices * Support Auto-Negotiation Full-Duplex/Half Duplex
 Note: Normally, an A-N switch will detect and set to full-duplex, where a dual-speed hub will detects half. The fiber port (POF) port of FT-807 is fixed at 100Mbps full-duplex mode. The link partner should also set at 100Mbps full-duplex mode at the same time. 1.6 Power information The power jack of FT-807 is with 2.5mm in the central post and required +5VDC power input. Should you have the issue to make the power connection, please contact with your local sales representative.
Chapter 2 Installation Please follow these steps to install the converter:   Turn off the power of the device/station in a network to which the FT-807 will be attached. Ensure that there is no activity in the network. Attach POF fiber cable with SMI type connector from the FT-807 to the fiber network also using POF. Attach a Cat. 5 UTP cable from the 10/100Base-TX network to the RJ-45 port on the FT-807. Connect the 5VDC power adapter to the FT-807 and verify that the Power LED lights up. Turn on the power of the device/station, the TP and POF LED should light when all cables are attached.   Note:   1.  RJ-45/STP, UTP Cat 5, straight/crossover cable is accepted. 2.  Please note the FT-807 supports LFP function, both ends should well connected. Otherwise, both TP and fiber port will remains off if any of the port is not connected 3.  Consult for your network administrator for more information about POF network equipments. Usually, another FT-807 is required for pair installation and transmission. Warning: As an optical equipment, to reduce the risk of injury to the eyes, do not look directly into the laser light on the POF interface and do not point the laser light into anyone's eyes in short distance.
Appendix A: RJ-45 pin assignment and cable system A.1 10/100Mbps, 10/100Base-TX When connecting 10/100Mbps TP port to other devices, a straight or crossover cable is necessary. The TP port of FT-807 supports auto-MDI detection. That means you can directly connect the TP port to any Ethernet devices without making a crossover cable.  The  following  table  and  diagram  show  the  standard  RJ-45  receptacle/ connector and their pin assignments:  RJ-45 Connector pin assignment Contact MDI Media Dependant Interface MDI-X Media Dependant Interface -Cross 1  Tx + (transmit)  Rx + (receive) 2  Tx - (transmit)  Rx - (receive) 3  Rx + (receive)    Tx + (transmit) 4, 5  Not used 6  Rx - (receive)    Tx - (transmit) 7, 8  Not used The standard cable, RJ-45 pin assignment        The standard RJ-45 receptacle/connector There are 8 wires on a standard UTP/STP cable and each wire is color-coded.    The following shows the pin allocation and color of straight cable and crossover cable connection:
             Figure A-1: Straight-Through and Crossover Cable Please make sure your connected cable is with same pin assignment and color as above picture before deploying the cables into your network.  A.2 100Mbps, 100Base-FX, SMI type connector FT-807 is using POF SMI type connector that is mostly being used for IEEE1394b transmission. The followings show the basic information.  The POF Cable should be a dual wire cable with 0.98mm optic core with cladding diameter 1mm. Also with jacket in diameter: 2.2 mm.  The SMI connector will as like the figure left. You can check with your network device dealer or administrator for the availability of the cable and connector.      Part No. 2010-AA3330-001