REVISION HISTORY 64b9c0d0 D714 4e5b 8e42 Cceed1e768b0

242Ac55E-F01C-45Fe-B688-919E86Ce340A 242ac55e-f01c-45fe-b688-919e86ce340a 242ac55e-f01c-45fe-b688-919e86ce340a 24 files plexus plexuscdn 3:

9686B95D-93Ad-4Cf8-A965-160953F7Ebd4 9686b95d-93ad-4cf8-a965-160953f7ebd4 9686b95d-93ad-4cf8-a965-160953f7ebd4 96 files plexus plexuscdn 3:

Be7Cb9Cb-20Da-4Cc3-A5F6-0D522Db48E29 be7cb9cb-20da-4cc3-a5f6-0d522db48e29 be7cb9cb-20da-4cc3-a5f6-0d522db48e29 3946 plexus attachments versionhistory app_data plexuscdn 3:

2E315365-25Ec-4712-B67F-8Ce0F41Abacf 2e315365-25ec-4712-b67f-8ce0f41abacf 2e315365-25ec-4712-b67f-8ce0f41abacf 3947 plexus attachments versionhistory app_data plexuscdn 3:

1A51E9E0-Ea19-4Ee4-8901-6D172A8A91Cf 1a51e9e0-ea19-4ee4-8901-6d172a8a91cf 1a51e9e0-ea19-4ee4-8901-6d172a8a91cf 3813 plexus attachments versionhistory app_data plexuscdn 3:

2018-05-08

: Plexus 64B9C0D0-D714-4E5B-8E42-Cceed1E768B0 64b9c0d0-d714-4e5b-8e42-cceed1e768b0 3812 plexus attachments versionhistory app_data

Open the PDF directly: View PDF PDF.
Page Count: 3

Supplier Quality Requirement
Quality Code Q44D
Rev Letter: A Page 1 of 3
*Notice: This document is considered “UNCONTROLLED” when it exists in any printed form.
See the Partner Portals - Supplier section of the Plexus Web page for the current master of this Q-code.
http://www.plexus.com
REVISION HISTORY
REV
DATE
ORIGIN
REASON FOR CHANGE(S)
A
12Feb18
Paul Gettins
New
Q-CODE Q44D QUALITY REQUIREMENTS
MATERIAL/HEAT TREATMENT/NDT
With acceptance of/or receipt of product against this order the supplier agrees to allow Plexus, their
customer and regulatory authorities the right of access to their facility and all applicable records. The
following are the quality requirements for product purchased under Q-code Q44D. Unless a written waiver
is received from Plexus, the supplier agrees to abide by the quality requirements listed below. Plexus will
only give a written wavier after notifying and obtaining approval from the customer authorized person and
Certified Body.
Pre-1st Shipment (Part Number or Revision change) - Before a product will be released for production the
supplier will be required to meet the documentation and quality requirements as follows:
A. First Article Inspection Report - All dimensions must be within print tolerance. Any dimension which is
not within print specification must be approved by Plexus in writing before product can be shipped.
B. Supplier Master Document List (SMDL)
C. Manufacturing Procedure Specification
D. Starting' Bar or Material 'Mill' Test Report/Certificate
EN10204 Type 3.1 Material Inspection Certification must detail the following:
Name of Material Supplier
Material Suppliers part number
Details of the Test/Inspection Results
The Lot # and Date Code or Serial numbers for each shipment
A statement of Compliance to specification
Signed and dated by an authorised inspection representative independent of the manufacturing
department.
E. Processed Material Test Report/Certificate
EN10204 Type 3.1 Material Inspection Certification must detail as per section C
F. Heat Treatment Report
G. Fastener Test Report ISO DIS 16228 F3.1
H. Non-Destructive Testing/Examination
Hardness Test Survey/Report
Magnetic Test (MT) Report - Surface
Penetrant Test (PT) Report Surface
Positive Material Identification (PMI) Test Report
Supplier Quality Requirement
Quality Code Q44D
Rev Letter: A Page 2 of 3
*Notice: This document is considered “UNCONTROLLED” when it exists in any printed form.
See the Partner Portals - Supplier section of the Plexus Web page for the current master of this Q-code.
http://www.plexus.com
Non-Destructive Testing or Examination (NDT/NDE) Operator Qualification
I. Certificate of Conformance (COC) must also include the following:
Name of Manufacturer/OEM/OCM
Manufacturer’s/OEM’s/OCM’s part number when required
Plexus part number
Revision or EC level if applicable
Quantity
Purchase order number
Lot # and Date Code 1 or Serial numbers for each shipment
A statement of Compliance specifying compliance to the following:
The drawings and specifications provided by Plexus
The requirements of the specific PO
Signed and dated by an authorised representative
1 The minimum-required date code format shall identify the 2-digit workweek, 2-digit year (WWYY). If the
component marking contains a lot and date code, then those markings must be traceable to the COC.
All cartons, required documentation, labels, packaging and packing slips must have part number, EC level or
revision, quantity and P.O. number listed on them.
Subsequent Shipments-The documentation and quality requirements for all subsequent shipments will be as
follows:
A. Starting' Bar or Material 'Mill' Test Report/Certificate
EN10204 Type 3.1 Material Inspection Certification must detail the following:
Name of Material Supplier
Material Suppliers part number
Details of the Test/Inspection Results
The Lot # and Date Code or Serial numbers for each shipment
A statement of Compliance to specification
Signed and dated by an authorised inspection representative independent of the manufacturing
department.
B. Processed Material Test Report/Certificate
EN10204 Type 3.1 Material Inspection Certification must detail as per section A
C. Heat Treatment Report
D. Fastener Test Report ISO DIS 16228 F3.1
E. Non-Destructive Testing/Examination
Hardness Test Survey/Report
Magnetic Test (MT) Report - Surface
Penetrant Test (PT) Report Surface
Supplier Quality Requirement
Quality Code Q44D
Rev Letter: A Page 3 of 3
*Notice: This document is considered “UNCONTROLLED” when it exists in any printed form.
See the Partner Portals - Supplier section of the Plexus Web page for the current master of this Q-code.
http://www.plexus.com
Positive Material Identification (PMI) Test Report
Non-Destructive Testing or Examination (NDT/NDE) Operator Qualification
F. Certificate of Conformance (COC) must also include the following:
Name of Manufacturer/OEM/OCM
Manufacturer’s/OEM’s/OCM’s part number when required
Plexus part number
Revision or EC level if applicable
Quantity
Purchase order number
Lot # and Date Code 1 or Serial numbers for each shipment
A statement of Compliance specifying compliance to the following:
The drawings and specifications provided by Plexus
The requirements of the specific PO
Signed and dated by an authorised representative
1 The minimum-required date code format shall identify the 2-digit workweek, 2-digit year (WWYY). If the
component marking contains a lot and date code, then those markings must be traceable to the COC.
All cartons, required documentation, labels, packaging and packing slips must have part number, EC level or
revision, quantity and P.O. number listed on them.
Shipments of multiple lot and/or date codes must be identified separately on the DOC with the actual quantity
shipped for each. Each lot and/or date code shall be independently packaged (i.e., no mixed lot/date codes
within a package: reels, trays, tubes, bags, etc.).
Material received without the completion and proper execution of the Quality Requirement allows Plexus the
right to return the material as defective. For material that has been previously provided to Plexus, the
requirements under subsequent shipments will be followed.