Plugwise STEALTH Plugwise Network Device User Manual 15a ZB9 STEALTH EN

Plugwise B.V. Plugwise Network Device 15a ZB9 STEALTH EN

Contents

15a_ZB9-STEALTH_User Manual EN

Sense200.106.110211Climate monitoring and managementManual
2 3Sense ManualThank you for buying this extension to your Plugwise system. With the Sense, you can wirelessly measure the temperature and air humidity in a room. In this way, you easily obtain insight into the climate in one or more rooms. The temperature sensor has a range of 0 to 60˚C; the air-humidity sensor has a range of  5  to  95%  RH.  You  can  also  link  switch  acons  to  certain measurement values. This does not require the computer to be le on.This manual describes the  installaon  of a single Sense, but the same steps can be followed if you want to install mulple Senses at the same me. Before you start• Werecommendthatyoufollowthismanualcarefully;itisessenaltotakethestepsinthecorrectorder.• Tobeabletousethe Sense,you willrequireaPlugwisenetworkconsisngofatleastaSckorStretchandaCircle+.A  Plugwise  network  can  never  contain  more  Senses  than  5  mes  the number of Circles. What this manual explains for the Circle also applies to the Stealth and the Sng, or a combinaon thereof.• Ensure that you use the latest version of Source and that yourmoduleshavethelatestrmwareversion.YoucancheckthisbyclickingtheUpdatesbuoninSource.TheSenseisonlysupportedifallothermoduleshavermwareversion2.36(asof13-05-2011)orlater.Ifthisis not yet the case, prior to the installaon of the Sense, the othermodulesmustrstbeupdated.InSource,checkwhethertheSckandallofthemodulesareonline.• InSource,checkwhethertheckattheboomleofthescreenshowsthattheSckisonline:• InSource,checkinthetreeat‘Overviews’toseewhetheralldevicesareonline.Thisisindicatedbygreyandyellowlights:• OnlyinsertthebaerywhenyoustarttousetheSense.ASenseusesagreatdealmorepowerifitisnotconnectedtoaPlugwisenetwork.• TousetheSense,itmustbeconnectedtoaPlugwisenetwork.TheSense canthenbe mounted on awall. These steps are explained inmoredetailbelow.• Check whether all components are present. If a component ismissing,pleasecontactusassoonaspossible.Contents of the package• PerSense:1 3,6V AA baery This manual    SenseMounng plateSense200.106.110211Climate monitoring and managementManual
4 51.  Adding the Sense to your Plugwise networkÌStartSourceandselectSengs,AddModules.ÌWhen you are asked to select a network, select the network towhichtheSensemustbeadded.ÌFillintheIDoftheSense.ThisIDisindicatedonthesckersthatareaachedtotheback.ÌClick the buon with the green arrow:  Next, insert the AAbaeryintheSense.Notethe+and-marks.ÌIfyouwanttoinstallmulpleSenses,addtheIDsforalloftheSensestothelist.ThePlugwisenetworkwillthensearchfortheSenseswiththenewIDsinthelist.WaitunlSourceindicatesthattheSenseisonline.Thecirclewiththequesonmarkwillthenchangeintothefollowingicon:If the Sense is not found within several minutes, check whether the Plugwise network is operang correctly (refer to ‘Before you start’). If the Sck and the other modules are available in Source and the Sense is sll not shown as being online, follow the instrucons to delete the network sengs under ‘Delete network sengs’, see: ‘Advanced use’.ÌClick‘Next’andthen‘Finish’.ÌTheSenseisnowconnectedtoyournetwork.2.  Attaching the Sense to the wallUp/Window >< ResetÌTaketheSensetothelocaonwhereitmustbeinstalled.Thismustbewithin5to10metresofaCircle.ÌCheckwhetherSourcesllindicatesthattheSenseisonline.ItcantakeseveralminutesforthenetworktoprocessthenewlocaonoftheSense.ÌAach the Sense mounng plate to the wall. The Up/Window arrow on the inside of the mounng plate indicatesthe top. Ensure that the Plugwise logo on the front endsup in a horizontal posion (see the corresponding gure).TheopmalheightoftheSenseis1.50to1.80metresabovetheoor.Inaddion,the Sensemustnotbeinstalledindirectsunlight,abovea centralheaterand preferablynotnearadoororwindow.ThiscannegavelyimpactthefunconingoftheSense.ÌWhenthemounngplateisaachedtothewall,slidetheSensefromaboveontotheplateunlyoufeeltheSenseclickintoplace.3.  UseCommunicaon in the networkThe Sense contacts one of the Circles in your network. This CircletransmitsthemeasurementdatatotheotherCircles.IftheCirclethattheSensetriestocontactisunavailable,aconneconwillbemadewithanotherCircle.Thiscantakeseveralseconds.Themeintervalbetweentwotransmissionsofmeasurementdatacanbespecied.Asstandard,theSenseissettoatransmissionintervalof15minutes.ThecomputerdoesnotneedtobeswitchedontobeabletousetheSense.Switching and insightTheSensecanbesetuptosendswitchcommandsifcertaintemperatureorair-humidityvaluesare exceeded:an OnorO command canbesenttoappliancesorlighngspeciedinadvancewithinthePlugwisenetwork.Whiledoingso,theSensedoesnottakeintoaccountotherswitching acons in the network, such as those from the PlugwiseSwitch or Plugwise Source. As standard, switching acons from theSenseareswitchedo.ItisnotrecommendedtousetheSenseasathermostat.AnoverviewoftheoponsforlinkingswitchingaconstotheSenseinSourceaswellasothersowarefunconsisavailableinthelatestSourcemanual.Themanualisavailableatwww.plugwise.com/manuals.
6 7Removing SenseIf the Sense will (temporarily) no longer be used, it can be removed from the Plugwise network. ÌStart Source and go to Sengs, Devices. ÌThe list of ‘Non-assigned modules’ is displayed to the right of the screen. Right-click the Sense and then click ‘Delete’. ÌThe Sense will now be ignored by the network. ÌTo also physically remove the Sense from the ceiling, follow the steps as described in secon 2, ‘Aaching the Sense to the wall’, in reverse order. ÌNote: remove the baery. As long as the Sense is not assigned to a network, it will consume more power and the baery will drain more quickly.4.  Advanced useConnecng Sense to another networkAer a Sense has been removed from a network (see the explanaon above), it can  be  connected to another Plugwise system. To  do  this, follow the normal installaon procedure.Restarng SenseIn case of problems, the Sense can be restarted. For this purpose, a reset buon can be found on the back of the module, which can be acvated by inserng a long, thin object such as a pin or a paperclip (not a pencil or mechanical pencil, which can break o) in the hole marked ‘Reset’. When the LED light in the casing (on the front of the module) begins to ash, the Sense has restarted.Deleng network sengsYou can also delete all of the sengs saved on the Sense. As a result, the Sense will also forget its posion in the network. To delete all of the sengs, follow the instrucons as described in the secon ‘Restarng Sense’, but keep the reset buon pressed unl the rapid ashing of the LED light stops. This should take about 10 seconds.Firmware updatesWhen  a  new  rmware  version  is  available,  the  update  can  be downloaded  and  sent  to  the  Sense.  More  informaon  on  rmware updates is provided in the Source manual. Aer you send the rmware update  from Source, press  the  white  wake buon  on the top  of the front of the Sense. The Sense will then waken temporarily to receive and install the rmware update. 5.  Technical detailsSpecicaonsParameters Min. Nominal Max. Unit CommentsEnvironmentOperaonal 056095˚C%RH No condensaonStorage 10205060˚C%RH No condensaonTemperature measurementMeasurement range 0 60 ˚CMeasurement accuracy± 0.8 ± 0.3 ˚C Within  a  range  of  0˚C  to 60˚C ± 0.6 ˚C At 0˚C± 0.3 ˚C At 25˚C± 0.8 ˚C At 60˚CAir humidity measurementMeasurement range 5 95 %RHMeasurement accuracy± 3.5 ± 2.0 %RH Within a range of 5%RH to 95%RH± 3.2 %RH At 5%RH and at 95%RH± 2.2 %RH Between  10%RH  and 90%RHPower supplySupply voltage 3.2 3.6 3.6 Vdc A single 3.6V AA baeryBaery life 1 2 yearBased on 1 rmware update per year, a maintenance interval of 24 hours and 1 transmission of measurement data per 15 minutesPower consumpon 150 mWDimensions 86 x 80 x 21 mm Height x width x depthMemoryStorage capacity 512 kByte Used  for  ZigBee  rmware updatesService life 100,000 Cycles Programming/delengZigBee communicaeBaud rate 250 kbps O-QPSKFrequency 2400 MHz 16 channels of the 2,4GHz ISM bandBandwidth 2.0 MHz 5 MHz channel spaceRecepon sensivity -92 -97 -98 dBm @ 1% per 20-byte packetTransmission power -32 3 5 dBmLEDWhen the Sense sends data wirelessly via the Plugwise ZigBee protocol, a red LED light starts to ash in the casing.
8 96.  EnvironmentOld electrical and electronic devices oen containvaluablematerials.Therefore,neverdisposeofdiscardeddevicesasnormalhouseholdrubbish.Handthedeviceintoalocalauthoritycolleconpointforelectricalandelectronicdevices.Neverthrowbaeriesawaywiththehouseholdrubbish;insteadhandtheminatthespecialcolleconpoints.7.  Support and contactAdetailedPlugwiseSourcemanualisdisplayedifyouclickthe‘Help’buonattheboomofthescreen.Our websitecontainsa pageoffrequentlyaskedquesons:www.plugwise.comIfyousllhavequesons,pleasecontactusvia thecontactformonthesupportpageonourwebsiteorviaourservicenumber.Youcanofcoursealsocontactusifcomponentsaremissing.Wewouldalsobepleasedtohearfromyouifyouarehappywiththedeliveredproduct.