Polimaster PM1703SERIES Personal Radiation Monitor User Manual 1703

Polimaster Inc. Personal Radiation Monitor 1703

user manual

Download: Polimaster PM1703SERIES Personal Radiation Monitor User Manual 1703
Mirror Download [FCC.gov]Polimaster PM1703SERIES Personal Radiation Monitor User Manual 1703
Document ID718170
Application IDC8xxT0dLuN0xWBV63SikoQ==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize231.81kB (2897573 bits)
Date Submitted2006-10-20 00:00:00
Date Available2006-10-28 00:00:00
Creation Date2006-09-28 11:04:38
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2006-09-28 11:04:38
Document TitleMicrosoft Word - 1703 user manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Daveg

POLIMASTER
PERSONAL RADIATION DETECTORS
РМ 1703М-О
РМ 1703GNО
РМ 1703МА
РМ 1703GNА
РМ 1703МВ
РМ 1703М-О1
РМ 1703GNВ
РМ 1703М-О1А
OPERATION MANUAL
http://www.polimaster.com
CONTENTS
General......................................................................................................................................................3
Indicator composition...............................................................................................................................5
Specifications ............................................................................................................................................6
Provision of explosion protection.............................................................................................................8
FCC statement ..........................................................................................................................................8
Clamp removal and installation...............................................................................................................9
Installation and replacement of a power supply cell ...............................................................................9
Control buttons. Information on LCD.....................................................................................................9
Indicator operation...................................................................................................................................11
Indicator on/off .........................................................................................................................................11
Operation modes.......................................................................................................................................11
Testing mode.............................................................................................................................................12
Calibration mode for the background level.............................................................................................12
Searching mode. Detection and localization of sources of gamma and/or neutron radiation…............13
Measuring mode of power ambient equivalent gamma radiation dose..................................................15
Measuring mode of power ambient equivalent gamma radiation dose along with the search function
...................................................................................................................................................................15
Searching mode "0-9". .............................................................................................................................16
Gamma registration mode........................................................................................................................16
Indication mode of the average speed of gamma radiation counting over the time of accumulation. ..17
Indication mode of neutrons. ...................................................................................................................17
Indication mode of the average speed of and count of neutrons over the time of accumulation . .........17
Quick switching of sound or vibration indication ...................................................................................17
Communication mode by a radio channel with a Pocket PC.................................................................18
Setting mode .............................................................................................................................................18
n factor setting of the gamma channel.....................................................................................................19
n factor setting of the neutron channel ....................................................................................................19
Setting of the searching threshold by power ambient equivalent gamma radiation dose for the searching
mode "0-9"................................................................................................................................................20
Setting of the fixed threshold of the count of neutrons for the searching mode "0-9" ..........................20
Mode of indication setting.
On/off of the sound and/or vibration indication......................................................................................21
Setting of the sound indication volume ....................................................................................................22
Communication mode with a personal computer. Indicator parameters. .............................................23
Technical maintenance .............................................................................................................................24
Possible malfunctions ...............................................................................................................................24
Storage and transportation ......................................................................................................................24
Manufacturer’s guarantees......................................................................................................................25
Acceptance certificate...............................................................................................................................25
Limited warranty .....................................................................................................................................26
Attachment A
Chart of ordering the operation modes and functions of the device.......................................................27
We thank you for purchase of the personal radiation detector of “Polimaster”
Before the beginning of operation with the personal radiation detector you should get
acquainted with the present manual.
! During the search of radiation sources observe the existing rules of operation with radio
active materials and sources, as well as the standards of radiation safety.
GENERAL INFORMATION1
The personal radiation detector
•
•
•
•
•
•
•
•
РМ 1703М-О
РМ 1703МА
РМ 1703МВ
РМ 1703GNО
РМ 1703GNА
РМ 1703GNВ
РМ 1703М-О1
РМ 1703М-О1A
(hereinafter referred to as the indicator) is intended for searching (detection and localization) of radio
active (and nuclear materials)2 by means of the analysis of the counting speed of impulses delivered from the
detector outlet at registration of gamma (and neutron)2 radiation with indication on a LCD:
- the average counting speed of gamma radiation;
- the average counting speed of neutron radiation средней скорости счета нейтронного излучения
(in the devices having the detector of neutron radiation2);
•
- power of the ambient equivalent of a dose of gamma radiations H *(10) along the line 137Cs in the
collimated radiation (hereinafter referred to as “MED”).
The indicator is not a meter.
The indicator can be operated both in premises and in the open air. The indicator can be used by a
wide circle of consumers, who are by their mode of activities related to detection and localization of sources
of the ionizing emissions.
The indicator is made as an explosion-proof model. The indicator relates to the explosion-proof
electric equipment of group II, sub-group IIC. By the level of explosion protection the indicator relates to
the especially explosion-proof electrical equipment and is intended for the use in potentially explosion-proof
environments (zone 0). The type of indicator explosion protection is “the sparkle-proof electric circuit ia”.
The history of indicator operation is retained in the power-independent storage and can be transferred
to a personal computer (PC) via the infra-red (IR) communication channel.
In the process of indicator manufacture amendments may be entered to the electric circuit, construction, external execution and software, which do not influence
the technical and metrological specifications and, therefore, not reflected in the present manual.
РМ1703GNO, РМ1703GNA, РМ1703GNB
The indicator is manufactured in 7 modifications.
Peculiar features of modifications
Detector type
modifications
РМ1703М-О
РМ1703М-О1 РМ1703М-О1А РМ1703МА
РМ1703МВ
РМ1703GNО
ANSI 42.33(1)
• γ- CsI (Tl) scintillator 3 сm3
• γ- G-M сounter
•
•
•
•
•
•
•
scintillator 4 сm3
•
Increased pulse sensitivity of γ-detector
•
LiI (Eu) scintillator 2 сm
Increased pulse sensitivity of n-detector
Information transmission to a Pocket PC (РРС) by a radio
channel of Bluetooth type
Possibility of identification
of the radio nuclide
composition of the substance with the aid of РРС
•
•
•
ATTENTION!
The indicators may differ by the totality of included (activated) operation modes.
Operation modes are switched on/off by the manufacturer according to the preliminary order of the customer (user) in
accordance with the chart of modes.
Certain modes may be independently switched on/off by the customer (user) by using the software included to the set of
indicator delivery.
Descriptions of all modes which are possible for devices of РМ1703 series are shown in “Operation modes”.
The chart of operation modes of your indicator is shown in Attachment А.
РМ1703GNВ
ANSI 42.33(1)
• n- LiI (Eu) scintillator1 сm3
CsI (Tl)
РМ1703GNА
•
•
•
INDICATOR COMPOSITION
The supply set composition of the indicator complies with the table.
Description, type
РМ
1703M-O
Personal radiation detector РМ1703М-О
Personal radiation detector РМ1703М-О1
Personal radiation detector РМ1703М-О1А
Personal radiation detector РМ1703МА
Personal radiation detector РМ1703МВ
Personal radiation detector РМ1703GNO
Personal radiation detector РМ1703GNA
Personal radiation detector РМ1703GNВ
Disk (software on CD)
Panasonic POWER LINE АА (LR6) power supply cell 1)
Key
Housing (made of synthetic cloth)2)
IR communication channel adapter (ACT-IR220L or IR210B)2)
Pocket РС1),2)
Operation manual
Consumer’s package
Transport package
1)
2)
Quantity per model
РМ
1703М-О1
РМ
1703М-О1А
РМ
1703МА
РМ
1703МВ
РМ
1703GNO
РМ
1703GNA
РМ
1703GNВ
USE OF OTHER SIMILAR BY PARAMETERS ONES IS ALLOWED
SUPPLIED AS PER INDIVIDUAL ORDER
SPECIFICATIONS
Sensitivity of the indicator to gamma radiation,
at least
РМ 1703М-О
РМ 1703М-О1
РМ 1703М-О1А
РМ 1703GNО
70 s-1/(mcЗv/h) (0.7 s-1/(mcR/h))– for 241Am;
100 s-1/(mcЗv/h) (1.0 s-1/(mcR/h))– for 137Cs
100 s-1/(mcЗv/h) (1.0 s-1/(mcR/h))– for 241Am;
100 s-1/(mcЗv/h) (1.0 s-1/(mcR/h))– for 137Cs
РМ 1703МА
РМ 1703МВ
РМ 1703GNА
РМ 1703GNВ
Sensitivity of the indicator to neutron radiation, at least
РМ 1703GNО
РМ 1703GNВ
0.05 imp.⋅cm2/neutron - for Pu- α -Be;
1.3 imp.⋅cm2/neutron-for heat neutrons
0.1 imp.⋅cm2/neutron - for Pu- α -Be;
2.5 imp.⋅cm2/neutron-for heat neutrons
РМ 1703GNА
Range of powers of gamma radiation registration
Range of powers of neutron radiation registration
from 0,033 to 3,0 MeV
РМ 1703GNА
РМ 1703GNО
РМ 1703GNВ
From heat to 14,0 MeV
Range of indication of MED of photon radiation
РМ 1703М-О1
0,01 - 9999 mcЗv/h (1 – 1000 mR/h)
РМ 1703М-О1A
0,01 mcЗv/h - 13 Зv/h (1 mcR/h – 1300 mR/h)
РМ 1703М-О
РМ 1703GNО
РМ 1703МА
РМ 1703МВ
РМ 1703GNА
РМ 1703GNВ
0,01 - 99.99 mcЗv/h (1 – 9999 mcR/h)
Relative error of MED measurement by line 137Cs in the
collimated radiation, not exceeding:
РМ 1703М-О1
- in the range from 0,1 to 9999 mcЗv/h (10 mcR/h–1000
мР/ч)
РМ 1703М-О1А
± 30 %
- in the range from 0,1 mcЗv/h to 10 Зv/h
±(15+К1/Н+К2Н)%, wherein N-value of MED, mЗv/h
- in the range from 10 mcR/h–1000 mR/h
±(15+К1/Н+К2Н)%, wherein N-value of MED , mR/h
К1 –factor equal to 0,0045 (mЗv/h)
К2- factor equal to 0,0015 (mЗv/h)-1
К1 - factor equal to 0,45 (mR/h)
К2- factor equal to 0,000015 (mR/h)-1
- in the range from 0,1 to 70 mcЗv/h (10 – 7000 mcR/h)
РМ 1703М-О
РМ 1703GNО
РМ 1703МА
РМ 1703МВ
РМ 1703GNА
РМ 1703GNВ
± 30 %
Time of measurement
Frequency of false operations in the mode of registration
of gamma-emissions with the radiation background 0,2
mcЗv/h (20mcR/h)
Frequency of false operations in the mode of registration
of neutron emission
РМ 1703GNА
РМ 1703GNО
РМ 1703GNВ
Time of indicator continuous operation
Calibration by background level
0,25 s
No more than operation per 12 h of continuous
operation
No more than operation per 12 h of continuous
operation
At least 1000 h*
-аutomatic – in case indicator switching, change
of n factors
-аutocalibration when the background level is
changed
-forced calibration by pressing the push button
by the user
-sound
-vibration
-visual
Signaling type:
Communication with PC via IR channel
- Reading of data from storage,
- Setting of indicator working parameters
Communication with Pocket PC by the radio channel of Nuclide Identification and network data
Bluetooth type
transmission
РМ 1703MВ
РМ 1703GNВ
Quantity of recorded events to the indicator storage
Terms of operation:
- range of ambient temperatures;
by 1000
From minus 30°C to 50 °С (-22° F to 122° F)
(LCD from minus 15°C to plus 50 °С)
- relative humidity
The indicator has resistance against impact of direct and
alternate magnet fields having intensity
The indicator has resistance against impact of
electrostatic discharges
The indicator has resistance against impact of radio
frequency electro-magnetic fields (under conditions of
noise emission from digital radio telephones)
Indicator supply
Protection degree of the indicator housing
The indicator is resistant against dropping from a height
to the concrete floor
by 95 % at 35°C (+95° F)
by 400 А/m
8 kV (air discharge),
6 kV (contact discharge)
10 V/m in the range of frequencies from 20 to 1000
МHz (amplitude sinusoidal modulation having depth of
80 % and frequency 1 KHz), 30 V/m in the range of
frequencies from 800 to 960 kHz and from 1,4 to 2,0 GHz,
(amplitude rectangular modulation having the depth of
100 % and frequency 200 Hz)
1.5 V*
(one cell POWER LINE АА (LR6) or similar by
parameters)
IP65
0.7 m (2.3 ft)
(1.5 m (4.9 ft) in a special protection housing)
Overall dimensions
РМ 1703М-О
РМ 1703МА
РМ 1703GNО
РМ 1703GNА
РМ 1703М-О1
РМ 1703М-О1А
72 х 32 х 87 mm (2 13/16" х 1 ¼" х 3 7/16")
РМ 1703МВ
РМ 1703GNВ
75 х 35 х 89 mm (2 15/16" х 1 3/8 " х 3 7/8")
Mass (without a housing), not exceeding
РМ 1703М-О
РМ 1703МА
180 g (6.35 oz)
РМ 1703GNО
РМ 1703GNА
РМ 1703М-О1
РМ 1703М-О1А
200 g (7.05 oz)
РМ 1703МВ
РМ 1703GNВ
230 g (8.1 oz)
* For power supply of the indicator a rechargeable storage battery may be used (or a supply cell differing from the
shown one in specifications). It is important that the typical size should correspond to АА (LR6) and rated voltage should be
within 1,1 - 1,6 V. However, in this case duration of the continuous work and the range of working temperatures may differ
from the above shown.
ATTENTION! The manufacturer guarantees the technical parameters of the indicator as far as detection of sources
and false operations are concerned at n factors set up at the manufacturer’s. :
- for gamma radiation n=5,3;
- for neutron radiation n=52 1
PROVISION OF EXPLOSION PROTECTION
The explosion proof model of the indicators is provided by the type of explosion protection “sparklefree electric circuit ia” as per IEC 60079-11 and execution of the indicator construction in accordance with
the requirements of IEC 60079-0 owing to the following designing and circuit technical solutions:
- provision of the normal degree of mechanical strength of the indicator casing in accordance with
the requirements of IEC 60079-0;
- the use of materials in the casing of the indicator excluding inflammability from electrostatic
discharges;
- limitation of the short circuit current down to 1,0 А from a galvanic supply cell having voltage 1, 5
V with the aid of a current limiting resistor and a fuse;
- the use of a special key for unscrewing the cover of the supply cell and a warning note in the
explosion hazard area “Do not open!”;
- limitation of internal capacity of alarm to values not exceeding the intrinsic safety level;
- introduction of limiting stabilitrons, shunting the piezoceramic cell 20 mm х 0,38 mm 4 kHz;
- use of sealing by means of the voltage converter compound 1,5 V – 20 V;
- provision of the protection degree for the indicator casing IP65 as per IEC 529.
Marking of the explosion protection at the indicator casing EEx ia IIC T4.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation
РМ1703GNO, РМ1703GNA, РМ1703GNB
CLAMP INSTALLATION AND REMOVAL
A removable clamp is provided to the indicator for wearing at the waist belt. The clamp may be
removed with the aid of a screw driver, as shown in fig.1a. The clamp is installed according to fig. 1б.
By an individual order the indicator may be provided with a protecting housing made of synthetic
cloth , also providing possibility of wearing at the waist belt. When the protecting housing is used, the clamp
is recommended to be removed.
b)
а)
Figure 1
INSTALLATION AND REPLACEMENT OF POWER SUPPLY CELL
The indicator is supplied without a supply cell installed.
For installation of the supply cell a cover of the supply section is to be unscrewed (11) (figure 2) with
the aid of a special spanner included to the supply set; to be installed to the supply cell by observing polarity
(the cell electrode marked with "+", must be directed inside the indicator); the cover of the supply section is
to be restored.
When the supply cell is installed the indicator is automatically switched on.
During switching on and during operation of the indicator periodic control is effected of voltage in
the supply cell. If the voltage becomes lower than 1,1 V, a mark “ ” is induced in the left lower part of the
LCD, and a light and sound (and/or vibrating) signal is given). In this case the supply cell should be
replaced.
Note – After appearance of a discharge symbol on the LCD the device retains workability for
at least 8 hours (with the normal background level).
The user may disconnect the indicator of the supply cell discharge for approximately 30
minutes by a short pressing the MODE button. Being so, signaling by operation thresholds will be
switched on.
CONTROL BUTTONS. INDICATION AT LCD
Two push buttons for the device control are located on the front panel of the indicator: (MODE) and
(LIGHT) , a liquid crystal display (LCD), a window of the IR transmitter-receiver, a light diode (LED),
figure 2.
1 (MODE) – a push button for :
-switching on the device;
-selection of operation modes;
-recalibration by the background
level
-change of parameters in the mode
of settings
2 (LIGHT) – a push button for:
-switching
on
the
LCD
illumination;
-switching
on
The
IR
communication with the PC;
- change of parameters in the mode
of settings
-switching off the device
3- a window of the IR transmitterreceiver
4 – a LED
Figure 2
5 – the upper LCD line is intended for display of:
• count speed, s-1 (in the searching mode)
• digits from 0 to 9 (in the searching mode);
• MED values of gamma radiation, µSv/h (µR/h) (in the mode of MED measurement);
• information "test", "CAL", "OL", "OFF", "Р-1.3" etc.;
• an indication type (sound or vibration)
6 – the analogue scale consisting of 19 segments is intended for:
• time indication to completion of the internal processor tests – reduction of the number of segments up
to their disappearance;
• time indication to completion of calibration completion by the background level – increase of the
number of segments up to the full scale filling;
• visual display of the MED level in the searching mode 0-9
7 – a mark of supply cell discharge
" ";
8 – marks indicating the paramemetrs of gamma, neutron21 emissions
9 – an indicator of the size of the induced value
• «s-1» – in the mode of searching the gamma radiation;
• «s-1» – in the mode of searching the neutron2 radiation;
• «µSv/h» – in the MED indication mode (option "µR/h")
10 – the low LCD line, intended for:
РМ1703GNO, РМ1703GNA, РМ1703GNB
10
• - indication of the average statistical expected indication error of MED, %
• - indication of the count speed of neutron21 radiation, (s-1)
11 – a cover of the power supply section
12 – a power supply cell
13 – a sound indicator
14 – a geometric detector center Cesium Iodide Scintillator
15 – a geometric detector center G-M tube
16 – a geometric detector center of neutron radiation detector
INDICATOR OPERATION
Attention! In case of the indicator operation at temperature below minus 15 °С normal
operation of the LCD is not guaranteed. In this case only sound or vibrating indicators should be used
as the source detecting indicator. When the indicator returns to the conditions with the temperature
above minus 15°°С the normal operation of the LCD is restored.
INDICATOR SWITCHING ON/OFF
For switching the indicator ON in the process of operation the MODE button should be pressed.
Immediately after switching on the LCD illumination must be switched on
and all LCD segments must be illuminated at the same time approximately for 1 s
signaling (sound and/or vibrating) must be switched on, the device must be shifted to
the testing mode. In the testing mode a number of the software version (P-1.4) is is
indicated at the LCD for several seconds.
After completion of the tests the indicator must be shifted to the calibration
mode by the background level (except for devices having the search mode "0-9"), the
analogue scale is indicated on LCD with the number of segments increased in time,
as well as the “САL” message.
After calibration completion the indicator must be shifted to the working mode in accordance with
the order chart (see attachment A).
The indicator is ready for operation.
For switching off the indicator a LIGHT button is to be pressed and kept for more than 5 s. Being
so, the "OFF" appears.
Attention! The indicator is automatically switched off (“OFF” is indicated
at the LCD) after reading the indicator operation history in the mode of
communication with a PC).
OPERATION MODES
Operation modes included by the manufacturer in the given indicator modification comply with
the order chart (see attachment А).
The indicator provides the following operation modes:
• the testing mode;
• the calibration mode by the background level;
• the searching mode (indication of the average count speed, s-1);
• the mode of MED measurement;
• the mode of MED measurement along with the search function;
• the searching mode "0-9" (indication of digits 0-9);
• the mode of gamma registration (only for РМ1703М-О1)
• the mode of indication of the average count speed of gamma radiation over the time of
accumulation (only for РМ1703М-О1)
РМ1703GNO, РМ1703GNA, РМ1703GNB
11
•
•
•
•
•
•
•
the mode of registration of neutrons21
the mode of indication of the average count of neutrons over the accumulation time2
the mode of fast switching of sound and vibrating signaling
the mode of settings:
 setting the n factor of gamma channel
 setting the n factor of neutron channel
 setting the threshold by MED for the searching mode "0-9"
 setting the threshold of neutrons count for the searching mode "0-9"
the mode of indication settings:
 selection of the sound and/or vibrating indication;
 setting the sound volume of the indication;
communication mode with PC via IR channel.
Communication mode by radio channel with Pocket PC (РМ1703MB, РМ1703GNB);
TESTING MODE
The device enters this mode just after switching on.
Before the beginning of the testing process the indication (sound and/or vibrating) is switched on
approximately by 1 s. All marks, segments and pointers must be indicated on the LCD.
Then on the LCD a number of the software version (P-1.4) is indicated on the LCD for
several seconds.
In the testing mode all required tests are fulfilled. Initially, the battery
discharge level is tested. “bAtt” is indicated on the LCD, as well as quantity of
segments of the analogue scale which corresponds to the battery discharge level.
Then the “test” message is indicated and the reducing analogue scale. Tests are
performed. The time to completion of the test is displayed in relative units on the
analogue scale in the form of the reducing number of the indicated segments.
After the test completion the device is shifted to the calibration mode by the
background level. The analogue scale is indicated on the LCD with the number of
segments increasing in time, as well as the message “САL”3.
CALIBRATION MODE BY BACKGROUND LEVEL32
The indicator enters this mode automatically after completion of the testing mode, and being so,
“CAL” message is indicated on the LCD
In the calibration mode the analysis of the background level of gamma (and
neutron) emission is carried out.
Attention! Find below the principles of operation of the device gamma channel.
Functioning of the neutron channel2 is subordinate to a more complicated operation algorithm and
is not shown in details in the present manual.
The processor counts the number of impulses passed from the detection block over the preset
calibration time, and the time is indicated on the analogue scale in relative units from the calibration
beginning in the form of increasing number of the indicated segments. In case of recalibration of the
indicator by the user during operation the recalibration time may automatically be reduced along with
growth of the background level, when calibration is fulfilled.
РМ1703GNO, РМ1703GNA, РМ1703GNB
The said mode in unavailable in indicators with the switched on SERCHING MODE "0-9"
12
The processor counts the value of the gamma channel operation threshold
Operation threshold = N + n * N
N – average speed of counting impulses over the calibration time
n – number of mean square deviations ( n factor of the gamma channel).
n factor changes the value of the operation threshold (the minimum detection level), the less n
factor, the less threshold value is and the higher indicator sensitivity is. n factor is set by the user in the
mode of settings, if this is permitted in the communication mode with PC by the user-administrator (the
manufacturer sets the value of n factor equal to 5,3). The range of factor setting is equal from 1 to 9,9 with
discreteness 0,1.
For recalibration of the indicator by the background level the MODE button should be pressed (to
be kept pressed for more than 2 s), until “CAL” message is indicated on the LCD, then the push button
should be released. The analogue scale will also be indicated on the LCD along with the number of segments
increasing in time.
The automatic calibration function may be switched on in the mode of communication with the PC.
Automatic calibration makes it possible to automatically retain the high sensitivity at reduction of the
background level and avoid false operations with its slow increase.
After calibration completion the indicator is automatically shifted to the operating mode in
accordance with the chart of orders (see attachment А).
SEARCHING MODE.
DETECTION AND LOCALIZATION OF SOURCES OF GAMMA AND NEUTRON
RADIATIONS.
Being in the searching mode the indicator shows the speed of counts of the gamma channel in the LCD
upper line, s-1.
The following is indicated in the lower line:
РМ 1703М-О1
РМ 1703М-О1А
РМ 1703М-О
РМ 1703МА
РМ 1703МВ
РМ 1703GNО
РМ 1703GNА
РМ 1703GNВ
All modifications
РМ 1703GNО
РМ 1703GNА
РМ 1703GNВ
• the average statistical indication error of the average count
of gamma radiation in per cents;
• the average speed of count of neutron radiation in s-1;
• If at indicator operation in the searching mode the average
speed of count of the gamma channel exceeds the upper
limit of indication, "OL" is indicated on the LCD.
• If at indicator operation in the searching mode the average
speed of count of the gamma channel exceeds the upper
limit of indication, “999" blinking message is indicated on
LCD.
13
In this mode the indicator operation is carried out to the following thresholds:
1) The fixed threshold by MED, set up in the communication mode with the PC by the useradministrator;
When the installed threshold is exceeded by MED the indicator sends light, sound and/or vibrating
signals. Being so single-tone periodical signals are sent with the constant interval and duration 1 s by making
it possible for the user to acknowledge indication when threshold by MED is exceeded from the operation
threshold.
2) The gamma channel operation threshold (the minimum detection level) calculated in the
calibration mode and taking into account the changes in the background level. When the gamma channel
threshold is exceeded the indicator light, sound and/or vibrating signals. Being so, frequency of the received
signals is constant and is increased along with the exceeded gamma channel operation threshold.
The whole range of energies of the indicator gamma radiations is divided into four energy channels.
Three channels correspond to areas of interest for low, middle and high energies, and the 4th one – to the
whole range of energies of the gamma radiation. The operation threshold is calculated for every channel.
The processor counts impulses every 0,25 s by each channel from the detection block, and it keeps
the amount of impulses during the counting. Being so, every 0,25 s the number of impulses over the last
(new) interval is added to the current amount, and the number of impulses during the first (the oldest)
interval is deducted from the sum of impulses (the current average). So, the number of impulses stored in the
processor for each channel is renewed every 0,25 s.
The current average number of impulses is compared every 0,25 s with operation thresholds for
each channel, which are calculated in the calibration mode (clause 2.2.3). If the current average value of
the number of impulses by any channel exceeds the threshold value, indication (light, sound and/or
vibrating) is switched on.
3) The operation threshold for the neutron channel21 c (The minimum detection level), calculated
in the calibration mode and taking into account the changes in the background level. If the operation
threshold is exceeded the indicator sends light, sound and/or vibrating signals. Being so, double signals are
sent with the permanent interval and duration, what making it possible for the user to find indication when
the operation threshold of gamma channel exceeds operation of the neutron channel.
In the searching mode the device resolves the problems of detection and localization of sources of
gamma and neutron radiation.
Detection of sources of gamma and neutron 2 radiation (II)
For II detection the device should be located so that the rear side (wherein the clamp is fixed) should
be directed to the tested object . The closer the device is placed to the tested object (luggage, a human being,
a container, a vehicle, etc) and the slower it travels along the object, detection efficiency is higher.
For II detection under conditions when sound signals of the indicator may be not heard (for example,
excessive noise) the vibrating and light indicator should be used.
One should remember that indicator sensitivity and frequency of false operations depend on:
- the preset value of n factor by the gamma channel;
- the preset value of n factor by the neutron channel;
- the background level calculated by the indicator in the calibration mode by the background level.
In case when automatic calibration is switched on in the communication mode with a PC, the
indicator will automatically take into account slow changes of the background level and calibrate by a new
background level approximately after every ten minutes with the reduction of the background level or after
somewhat bigger intervals during increase of the background level. However, automatic calibration will be
carried out under conditions of absence of indicator operations or sharp changes of the background level
over certain intervals defined by the algorithm.
РМ1703GNO, РМ1703GNA, РМ1703GNB
14
It should be borne in mind that in case of false operations the signals (light, sound and/or vibrating)
are not systematic, and therefore, they differ from detection signals in case of II availability, with their
frequency being constant and increasing as far as approaching to II.
In case of II detection or if any information is available about possible II availability, II localization
is started.
Localization of sources of gamma and neutron21 radiation
For II localization the indicator should be kept at the distance of not exceeding 10 cm from the
object. The traveling speed in relation to the object shall not exceed 10 cm per second. By approaching II
frequency of signals increases.
With the switched on sound indication sound signals are heard accompanied with blinking of a red
LED. With the switched on vibrating indicator mechanical vibrations are felt inside the indicator (casing
trembling) accompanied with a red LED.
When the limit frequency of light, sound and/or vibration signals have been reached the further
localization becomes impossible without calibration by a new background level. For this purpose, if
possible, a MODE button should be pressed without changing the distance to the object, and this is to be
retained by appearance of “CAL” message on the LCD. The indicator will calibrate by a new background
level, after what II localization can be continued. If necessary, these actions cam be repeated several times
up to location of II.
During localization of the source of neutron2 or mixed gamma and neutron radiations the sound and
vibrating indication can not be used, as the indicator will send signals typical for exceeding the speed
threshold of counting the neutron channel without any reaction to source approaching and removing. In this
case localization should be visual by observing the readings of count speed (or MED) in the upper line of the
LCD (gamma channel) or count speed in the lower line of the LCD (neutron channel).
MODE OF MED MEASUREMENT.
Staying in the MED measuring mode the device in the upper LCD line indicates the MED of photon
•
radiation Н *(10), in mcЗv/h. The lower line indicates the average statistical MED indication error in
percents.
If during device operation in the measuring mode the MED value exceeds the
upper limit of the measuring range by more than 1.3, “OL” message is shown on the
LCD.
MED MEASURING MODE ALONG WITH SEARCHING FUNCTION.
•
Staying in this mode the device in its upper line of LCD induces the photon radiation MED Н *(10),
in mcЗv/h.
The following is indicated in the lower line:
РМ 1703М-О1
РМ 1703М-О1А
РМ 1703М-О
РМ 1703МА
РМ 1703МВ
РМ 1703GNО
РМ 1703GNА
РМ 1703GNВ
• average statistical error of MED indication in percents
• average speed of count of neutrons in s-1;
Attention! The indicator may perform the searching and localizing functions of the ionizing
radiation in this mode. This is stipulated in the devices, wherein the searching mode is unavailable, or
РМ1703GNO, РМ1703GNA, РМ1703GNB
15
the searching function is additionally included in the measuring mode (see the order chart – attachment
A).
SEARCH MODE "0-9".
In the searching mode "0-9" digits from 0 to 9 are indicated on the LCD display. Compliance of
MED values by γ - channel and digits indicated on the indicator LCD is shown in the table.
Indicated figure
Range of
From
≥3,6
≥7,2
≥10,8 ≥14,4 ≥18,0 ≥21,6 ≥25,2 ≥28,8 ≥32,4
indicated MEG, background <7,2 <10,8 <14,4 <18,0 <21,6 <25,2 <28,8 <32,4 <36,0
mcЗv/h
to 3,6
The analogue scale is in parallel filled in. The number of illuminating segments of the analogue scale
is proportional to the digit induced on the LCD.
In the searching mode "0-9" operation of the indicator is carried out in the following
thresholds:
1) The searching threshold by MED is set in the mode of settings from the front
panel of the indicator, as well as in the mode of communication with a PC by the user-administrator. The
range of threshold setting is equal to 15 – 7777 µR/h (0.15-77.77µSv/h), recommended - 30µR/h (0,3
µSv/h)). The preset searching threshold exceeding by MED is accompanied with light and sound signaling.
Mechanical vibrations inside the device (casing trembling) are felt with the switched on vibrating indicator
instead of sound signals. Frequency of signals increases by device approaching to the gamma radiation
source.
2) The safety threshold – the 2nd threshold by MED, is only set in the mode of communication
with a PC by the user administrator. The range of threshold setting is equal to 10 – 7000 µR/h (0.170µSv/h), the recommended one – 3mR/h (30 µSv/h)). The light, sound and/or vibrating signals are
provided in case of exceeding the safety threshold. Being so, single tone periodical signals are provided with
the permanent interval and duration of 1 s what makes it possible for the user to differentiate the indication
in case of exceeding the searching threshold by MED from the safety threshold.
Compliance of speed values by neutron21 channel and digits indicated on the device LCD
is shown in the following table.
Indicated figure
Count speed
From
≥2
≥4
≥6
≥8
≥10
≥17
≥24
≥31
≥41
backg
<4
<6
<8
<10
<17
<24
<31
<41
round
to 2
The fixed threshold of counting neutrons for the searching mode "0-9" (the range of threshold setting
is equal to 1.0 – 99.0 s-1, recommended – 1.5 s-1) is set in the mode of settings from the front indicator
panel, as well as in the communication mode with a PC by the user-administrator.
GAMMA REGISTRATION MODE (only for РМ1703М-О1)
In this mode in the upper line of LCD a γ is shown and the quantity of accumulated count impulses is
indicated in the form of:
ХХХХ – in case of indication by the value of 9999 impulses
Х.ХЕХ – in case of indication above 9999 impulses, wherein Х is any figure
from 0 to 9, ЕХ is 10х.
Time of accumulation of impulses in hours is indicated in the lower LCD line.
РМ1703GNO, РМ1703GNA, РМ1703GNB
16
INDICATION MODE OF AVERAGE SPEED OF GAMMA RADIATION INDICATION
DURING ACCUMULATION (only for РМ1703М-О1)
In this mode in the upper line of LCD a γ is blinking, and the average count time is
shown during accumulation time (s-1).
The lower LCD line shows the value of the statistical error of the average count speed
in percents.
For reset of the current value of impulse counting and accumulation renewal a MODE
button should firstly be pressed and retained by staying in this mode.
MODE OF NEUTRONS REGISTRATION21
In this mode the number of accumulated count impulses is indicated in the LCD upper line:
ХХХХ – in case of indication by the value of 9999 impulses
Х.ХЕХ – in case of indication above 9999 impulses, wherein Х – any figure
from 0 to 9, ЕХ is 10х.
n mark is blinking in the lower line of the LCD and the time of impulses
accumulation is indicated in hours.
INDICATION MODE OF AVERAGE SPEED OF NEUTRON RADIATION INDICATION DURING
ACCUMULATION 2
In this mode in the upper line of LCD the average count time is shown during accumulation time (s-1).
The lower LCD line shows the value of the statistical error of the average count speed in percents.
For reset of the current value of impulse counting and accumulation renewal a MODE
button should firstly be pressed and retained by staying in this mode.
FAST SWITCHING OF SOUND OR VIBRATING INDICATION
In this mode the user may check the preset indication or select another indication type (sound – (Aud
-on) or vibrating – (Vibr-on)).
In order to enter this mode a MODE push
button should be pressed for a short time
in any operating mode, provided that
button pressing has not been effected
during the last 15 seconds. The current
indicating type shall be displayed on the
device LCD. Selection (switching) of the
required indication type is carried out by
short pressing of LIGHT PUSH BUTTON.
It should be borne in mind that the user may change the sound volume in the mode of settings.
РМ1703GNO, РМ1703GNA, РМ1703GNB
17
COMMUNICATION MODE BY RADIO CHANNEL WITH POCKET PC41.
In the communication mode with РРС by radio channel, of Bluetooth type the modification
indicators: РМ1703МВ, РМ1703GNB make it possible to identify the radio nuclide substance composition.
For setting the communication between the indicator and the "Bluetooth" mode should be switched
on in the indicator. For this purpose a MODE push button should be started for several times until the note [–
bt–off] is indicated on the LCD. A LIGHT push button should be used for switching over the state of
«Bluetooth» to [–bt–on].
Further
the
user’s
program "Smart2003" should be
started.
Indicator operation in this mode
is described in Help site and
supplied on a CD.
Attention!
1. In case of the indicator operation in the mode of communication with РРС access to the mode of settings of the
indicator with the aid of indicator settings on the front panel will be IMPOSSIBLE. All settings are performed
with the aid of РРС.
2. It should also be taken into account that in case of inclusion of "Bluetooth" mode power supply of the
indicator essentially increases.
At switching over the "Bluetooth" mode the indicator enters after approximately 1 minute the sleeping mode,
and being so, LCD will have the following forms:
• the radio channel is on, no communication with the PРС;
• the radio channel is on, communication with the PPC has
been established;
For switching off the «Bluetooth» mode a MODE should shortly be switched on several times until
[–bt–on] note is indicated. A LIGHT button is to be used for switching over the state «Bluetooth» in [–bt–
off].
MODE OF SETTINGS
The indicator is included to the mode of settings at long (more than 5 s) pressings of MODE push
buttons. By a short pressing of MODE button the user selects the preset parameter:
-the preset n-factor value (the number of average square deviations) should be checked or a new one
is to be set up in the channel of gamma-radiation registration (the range of n factor setting is equal from 1
to9,9 with discreteness 0,1);
- the preset n-factor value or a new one is to be set up in the channel of neutron radiation registration
(РМ1703GNО, РМ1703GNА, РМ1703GNВ);
- the preset value is to be checked or a new value of the searching threshold is to be set as per MED
for the searching mode "0-9" (the threshold setting range is equal to 15 – 7777 µR/h (0.15-77.77µSv/h),
recommended - 30µR/h (0,3 µSv/h));
a PPC with the Bluetooth installed should be used for indicator operation in the said mode.
18
- the preset value is to be checked or a new value of the fixed threshold is to be set for the searching
mode "0-9" (the threshold setting range constitutes 1.0 – 99.0 s-1, recommended – 1.5 s-1) (РМ1703GNО,
РМ1703GNА, РМ1703GNВ);
-the preset states of indicators of sound and/or vibrating ones are to be set, or thay are to be replaced
(on/off);
-the preset sound volume of the sound indicator is to be checked or changed.
GAMMA-CHANNEL N-FACTOR SETTING
For setting n-factor one should be shifted to the mode of settings, for what a MODE push button
should be pressed and kept pressed for more than 5 s. "CAL." will appear on the LCD, and then the installed
value of n-factor of the gamma channel.
For changing the value of n-factor one should shortly press LIGHT push button during subsequent
four seconds. The preset value of n-factor will blink by indicating its possible change. If the LIGHT button
was not pressed during the said time interval, the indicator automatically returns to the working mode.
Subsequent pressings of the LIGHT push button increase the preset value of n factor with pitch 0,1.
Subsequent pressings of the MODE push button increase the preset value of n factor with pitch 0,1. If the
push buttons are kept pressed the values are reduced or increased accelerated with the same pitch. After
setting the required n-factor of the gamma channel after expiry of approximately 6 s after the last pressing
the push button the indicator will automatically be shifted to the calibration mode.
SETTING OF N FACTOR OF NEUTRON CHANNEL21
For setting n-factor one should shift to the mode of settings, for what a MODE push button should
be pressed and kept pressed for more than 5 s. "CAL." will appear on the LCD, and then the installed value
of n-factor of the gamma channel. A MODE push button should one be pressed and the value of n-factor of
the neutral channel will be indicated on the LCD.
For changing the value of n-factor one should shortly press LIGHT push button during subsequent
four seconds. The preset value of n-factor will blink by indicating its possible change. If the LIGHT button
was not pressed during the said time interval, the indicator automatically returns to the working mode.
РМ1703GNO, РМ1703GNA, РМ1703GNB
19
Subsequent pressings of the LIGHT push button reduce the preset value of n factor with pitch 0,1.
Subsequent pressings of the MODE push button increase the preset value of n factor with pitch 0,1. If the
push buttons are kept pressed the values are reduced or increased accelerated with the same pitch. After
setting the required n-factor of the gamma channel after expiry of approximately 6 s after the last pressing
the push button the indicator will automatically be shifted to the calibration mode.
SETTING OF SEARCHING THRESHOLD BY MED FOR SEARCHING MODE "0-9"
For setting the searching mode by MED one should shift to the mode of settings, for what a MODE
push button should be pressed and kept pressed for more than 5 s. The threshold value by MED will appear
on the LCD.
For changing the value of the threshold by MED one should shortly press LIGHT push button during
subsequent four seconds. The preset value of the searching threshold by MED will blink by indicating its
possible change.
If the LIGHT button was not pressed during the said time interval, the indicator automatically returns
to the working mode. Subsequent pressings of the LIGHT push button reduce the preset value of the
threshold by MED with pitch 0,1. Subsequent pressings of the MODE push button increase the preset value
of the threshold by MED with pitch 0,1. If the push buttons are kept pressed the values are reduced or
increased accelerated with the same pitch. After setting the required threshold value by MED after expiry
of approximately 6 s after the last pressing the push button the indicator will automatically be shifted to the
operation mode.
SETTING THE FIXED THRESHOLD OF NEUTRONS COUNTING FOR MODE "0-9"
For setting the threshold of count of neutrons one should shift to the mode of settings, for what a
MODE push button should be pressed and kept pressed for more than 5 s. The threshold value by MED will
appear on the LCD. A MODE push button is once to be pressed, and the value of the neutrons count
threshold will be indicated on the LCD.
20
For changing the value of the threshold of the neutrons count one should shortly press LIGHT push
button during subsequent four seconds. The preset threshold value will blink what shows its possible change.
If the LIGHT button was not pressed during the said time interval, the indicator automatically returns to the
working mode.
Subsequent pressings of the LIGHT push button reduce the preset value of the threshold with pitch
0,5. Subsequent pressings of the MODE push button increase the preset value of the neutrons count
threshold with pitch 0,5. If the push buttons are kept pressed the values are reduced or increased accelerated
with the same pitch. After setting the required threshold value of the neutrons count after expiry of
approximately 6 s after the last pressing the push button the indicator will automatically be shifted to the
operation mode.
MODE OF INDICATION SETTINGS
ON/OFF OF SOUND AND/OR VIBRATING INDICATION
The state selection (on/off) of vibrating and sound indicators from the front panel is possible if this mode is
allowed at setting the parameters set up in the mode of communication with a PC. If this mode is allowed
sound or vibrating indication is on/off in the following way:
- the setting mode is to be switched on, for what a MODE button should be pressed and kept for more
than 5 s. CAL." will appear on the LCD, and then the installed value of n-factor;
- a MODE push button is shortly be pressed (1 or 2 times, depending on the modification), until
“Aud-oFF” or “Aud-on” message appears.
The abbreviated "Aud" note indicates the sound indication,
"oFF" (“on”) marks for the off (on) state of the sound indication.
For changing the state of sound indication one should, when this note appears, select the required state
of the sound indication by means of the LIGHT push button. This state is left by either automatically, if
during approximately 6 s the push button was not pressed, or at sort pressing the MODE,
21
- being so, “Vibr-oFF” or “Vibr-on” message will appear on the LCD. The abbreviated note "Vibr" –
indicates the vibrating indication, notes "oFF" (“on”) – the off (on) state of the vibrating indication. Setting
of and removal from this mode is performed by actions similar to the aforesaid ones.
SETTING THE SOUND INDICATION VOLUME.
In this mode the user may set up the required sound indication level.
For changing the sound indication level one should switch on the setting mode, for what the MODE
button should be pressed and retained for more than 5 s. “CAL” note will appear on the LCD, and then the
device will enter the mode of n-factor settings. By a short pressing the “MODE” push button the mode of nfactor setting and the mode of setting the indication type (if switched on) are to be “looked through”.
- If the sound indication is switched on in the device, then at entering the mode of sound volume
setting “Aud” note will be indicated on the LCD, as well as the preset sound indicator value from 1 to 5. For
changing the sound volume a LIGHT push button should be shortly pressed. Being so, the indicated volume
value must blink. The subsequent pressing of the LIGHT push button reduces the blinking value by a unit,
and pressing the MODE push button increases it.
Change of the value is accompanied with a sound signal in compliance with the sound volume.
- If the sound indication is off in the device, then at entrance to the setting mode of the sound volume
“Vibr” note will be shown at the LCD of the sound indicator. Then a LIGHT push button should shortly be
pressed, and Aud note will be shown on the LCD as well as the blinking value of sound indicator from 1 to
5. The subsequent pressing of the LIGHT push button reduces the blinking value by a unit, and pressing the
MODE push button increases it.
Change of the value is accompanied with a sound signal in compliance with the sound volume.
22
COMMUNICATION MODE WITH PC. INDICATOR PARAMETERS
ATTENTION! Operation in the communication mode with a PC is intended for a trained user
or the user-administrator.
Access to the communication mode with a PC for an ordinary user is protected with the
password.
Communication mode with a PC by IR communication channel
For indicator operation in this mode a PC with IrDA should be used or an adapter of the IR
communication channel supplied along with the indicator by an individual order (see the complete set) and
the user’s program (ПП) РМ17ХХ_14ХХ, supplied at the CD.
Minimum requirements for the computer and its software:
-Р100;
-32 Мbyte ROM;
-Windows 98, 2000, XP (small print in Windows set);
-20 Мbyte of free space on HD plus the free space for the formed data base;
-monitor resolution 800х600;
-IrDA.
If the built-in IrDA is unavailable in the computer, the IR communication channel should be used
which is to be supplied as per individual order. For connection of the adapter of the IR communication
channel the adapter cable is to be linked with a PC communication port.
For PP setting a CD with the software should be used included to the supply set.
A SETUP.EXE program is to be started at the computer by using the installation document install.doc. (the automatic start-up is supported).
Operation with the PP is described in thе Help site in the attached textual document which are
installed along with the user’s software.
For switching on the communication mode with a PC an indicator should be
placed at the distance of 10-12 cm from an adapter window of the (IrDA)
communication channel, and a LIGHT push button should be pressed. As soon as the
indicator enters the mode of information exchange, “Ir” message will be illuminated on
the LCD.
*Note – The indicator is automatically switched off ( "OFF" note is indicated on the LCD)after
reading the indicator operation history in the mode of communication with a PC.
INDICATOR PARAMETERS
Indicator parameters are set up in the communication mode with a PC user-administrator (the access is
protected with a password).
The manufacturer sets up the access password – 1.
The indicator is supplied to the user along with initial settings which comply with the chart of orders
(see attachment A).
During operation in the communication mode with a PC the user-administrator may fulfill the
following actions:
In the information system
- to register belonging of the indicator to a specific user;
- to remember the time of indicator sending and returning;
- *to read information from the indicator storage, including the history of its operation:
-the indicator number;
-time of indicator on/off;
-current MED value by the gamma channel via the consecutive time interval set up by
the user;
23
-time and indicator readings in case of exceeding the operation threshold of the
gamma channel;
- time and indicator readings in case of exceeding the operation threshold of the
neutron channel;.
In settings of indicator/program
- to check and/or set up working parameters of the indicator:
- to switch on the sound/or vibrating indicators;
- to synchronize the time and the date of the indicator with the current time and the PC date on the
moment of information exchange – automatically during every communication of the indicator with the PC;
- to set up the values of the values of the consecutive time intervals for storing the current values of
MED in the power-independent indicator storage;
- to change the password for entrance to the file of parameters (the initial password -1);
- to check and set up the fixed threshold by MED, if exceeded, the indicator provides a light, sound
and/or vibrating signals;
- to check the preset or set up new values of n-factors by each channel determining the operation
thresholds (minimal values of gamma and neutron radiation detection);
- automatic calibration should be switched on/off;
TECHNICAL MAINTENANCE
The technical maintenance of the indicator:
- performance of preventive works (external inspection, dust removal and deactivation, check of
indicator workability (see indicator on/off). Deactivation is performed by wiping with clothes moistened in
ethyl spirit.
-replacement of a supply cell in the explosion hazard area is strictly prohibited).
In case of visible mechanical damages of the casing and protection glass of the LCD indicator (dents,
burrs, cracks) operation of the indicator is prohibited.
POSSIBLE MALFUNCTIONS
Typical malfunctions
Troubleshooting
• The indicator can not be switched on
Wrong installation of the power cell
• The LDC indicates the mark
The power cell is to be replaced
" "
Other malfunctions shall be eliminated by the manufacturer.
STORAGE AND TRANSPORTATION
Storage
Indicators must be stored at storehouses in the manufacturer’s package at the ambient temperature
from minus 15 to plus 50 °С and relative humidity by 95 % at temperature 35 °С. Storage duration shall not
exceed the average service life of the indicator – 8 years.
Indicators without packages should be stored at the ambient temperature from 10 to 35 °С and
relative humidity 80 % at temperature 25 °С.
In the storage premises there shall be no dust, vapours of acids and alkalis, aggressive gases and other
harmful admixtures causing corrosion.
Transportation
Indicators in the packaged form and switched off state allow transportation by any closed transport
type at the ambient temperature from minus 50 to plus 50оC.
The packed indicators must be fixed in a vehicle. Placement and fastening of the packed indicators in
the vehicle shall provide their stable position, exclude possibility of shocks on each other , as well as on
vehicle walls.
24
In case of transportation by the sea transport the indicators in the packed form must be placed to a
polyethylene housing with the silica gel drier.
During transportation by air the indicators in the packed form must be located in sealed sections.
MANUFACTURER’S GUARANTEES
The manufacturer hereby guarantees compliance of the indicator with the requirements of
Specifications and operation, transportation and storage rules set up in the present Operation Manual.
The warranty operation period is equal to 18 months since the date of putting the indicator into
operation within the warranty storage period.
The warranty storage period is equal to 6 months since the date of acceptance of the indicator by the
manufacturer’s Quality Control Department representative.
The warranty and post-warranty repair is to be performed by the manufacturer or organization having
the manufacturer’s permit.
The warranty does not concern the indicators:
- at expiry of the warranty operation term if the indicator is purchased within the limits of the
warranty storage period;
- in case of the non-warranty maintenance (if traces of indicator opening are visible);
- in case of mechanical damages and non-observance of operation and storage rules;
- in case of submitting the indicator for the warranty service without the operation manual.
The warranty operation period is to be prolonged for a period of the warranty repair.
The warranty obligations do not refer the supply cells. Replacement of the supply cell is not
considered the warranty repair.
ACCEPTANCE CERTIFICATE
The personal radiation detector РМ1703______
manufacturer’s No. __________________________________,
has been mane and accepted in compliance with the requirements of the state standards, the existing
technical documentation and found fit for operation.
Chief of Quality Control Department
Stamp of the QCD
______________ ___________________
Signature, deciphering of the signature
"______" __________________
25
LIMITED WARRANTY
Polimaster Inc. (“Polimaster”) warrants to the purchaser (the “Purchaser”) that the Product, including component parts, to be free from material defects in material
and workmanship, under normal use and service for a period of one year (the “Warranty Period”) provided, however, that the foregoing warranties are expressly
contingent (and shall otherwise be void) upon use of the Products in accordance with specifications and without misuse, abuse, or abnormal use, accident, damage,
alteration, or modification thereto or improper or unauthorized repairs or improper maintenance. Non-substantial variations of performance from the
documentation do not establish a warranty right.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTIES STATED HEREIN, AND FOR ANY WARRANTY, CONDITION, REPRESENTATION OR
TERM TO THE EXTENT TO WHICH THE SAME CANNOT OR MAY NOT BE EXCLUDED OR LIMITED BY LAW APPLICABLE TO PURCHASER IN
HIS/HER/ITS JURISDICTION, THE PRODUCTS AND SERVICES HEREUNDER ARE PROVIDED “AS IS AND WITH ALL FAULTS” AND, TO THE
MAXIMUM EXTENT PERMITTED BY LAW, POLIMASTER DISCLAIMS ALL OTHER WARRANTIES, OF ANY KIND, EITHER EXPRESS, OR
IMPLIED, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,
INTEGRATION, SATISFACTORY QUALITY, NONINFRINGEMENT OR ANY WARRANTIES ARISING FROM COURSE OF DEALING OR COURSE
OF PERFORMANCE. PURCHASER ASSUMES ALL RISKS AND RESPONSIBILITIES FOR SELECTION OF THE PRODUCT TO ACHIEVE
HIS/HER/ITS INTENDED RESULTS, AND FOR THE INSTALLATION OF, USE OF, AND RESULTS OBTAINED FROM THE PRODUCT. POLIMASTER
DOES NOT WARRANT THAT THE PRODUCTS AND SERVICES HEREUNDER WILL MEET PURCHASER'S OR USERS' REQUIREMENTS OR WILL
OPERATE IN THE COMBINATIONS WHICH MAY BE SELECTED BY PURCHASER OR USER OR THAT THE SERVICES HEREUNDER OR THE
OPERATION OF THE PRODUCTS WILL BE SECURE, ERROR-FREE, OR UNINTERRUPTED, AND POLIMASTER HEREBY DISCLAIMS ANY AND
ALL LIABILITY ON ACCOUNT THEREOF TO THE MAXIMUM EXTENT PERMISSIBLE UNDER APPLICABLE LAW. POLIMASTER DISCLAIMS
ANY AND ALL LIABILITY FOR THE LOSS OF DATA DURING ANY COMMUNICATIONS AND ANY LIABILITY ARISING FROM OR RELATED TO
ANY FAILURE BY POLIMASTER TO TRANSMIT ACCURATE OR COMPLETE INFORMATION TO PURCHASER.
EXCLUSIVE REMEDY. Other than termination of this Agreement due to Polimaster's breach, as Purchaser’s exclusive remedy for any defect or nonconformity in
the Product, Purchaser shall obtain from Polimaster repair or replacement of the Products containing such defect or nonconformity (“Affected Products”). In
furtherance of such undertaking, if Purchaser reasonably believes that any Product contains a defect or nonconformity for which Polimaster is responsible,
Purchaser shall inform Polimaster of the nature of such defect or nonconformity in reasonable detail and shall request authorization from Polimaster to return the
Affected Products to Polimaster for repair or replacement. All Products so returned shall be shipped prepaid or otherwise delivered to Polimaster's facility or
authorized service center. If Polimaster fails to repair or replace the Affected Products within a reasonable time after Purchaser has so returned them to Polimaster,
Purchaser shall be entitled to repayment or credit of the original price of the defective or nonconforming Product as its exclusive further remedy.
EXCLUSIONS OF DAMAGES AND LIABILITY. PURCHASER ASSUMES THE ENTIRE COST OF ANY DAMAGE RESULTING FROM THE USE OF
THE PRODUCT AND THE INFORMATION CONTAINED IN, GATHERED OR COMPILED BY THE PRODUCT, AND THE INTERACTION (OR
FAILURE TO INTERACT PROPERLY) WITH ANY OTHER HARDWARE OR SOFTWARE WHETHER PROVIDED BY POLIMASTER OR A THIRD
PARTY. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT WILL POLIMASTER OR ITS SUPPLIERS OR
LICENSORS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, ANY SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS
INFORMATION, LOSS OF DATA, LOSS OF GOODWILL, WORK STOPPAGE, HARDWARE OR SOFTWARE DISRUPTION, IMPAIRMENT OR
FAILURE, REPAIR COSTS, TIME VALUE OR OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, OR
THE INCOMPATIBILITY OF THE PRODUCT WITH ANY OTHER PRODUCT, HARDWARE, SOFTWARE OR USAGE, EVEN IF SUCH PARTIES HAVE
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Limitation on Liability. Notwithstanding any provision to the contrary herein and with the exception of the claims of intellectual property rights infringements and
the payments obligations hereunder, the liability of Polimaster for any claim whatsoever related to the Products or this Agreement, including any cause of action
sounding in contract, tort, or strict liability, shall not exceed the greater of Ten Thousand ($10,000.00) Dollars or the total amount of payments theretofore paid by
Purchaser during the previous six month period to Polimaster in connection with the Products relating to such liability. THIS LIMITATION OF LIABILITY
SHALL NOT APPLY TO LIABILITY FOR DEATH OR PERSONAL INJURY TO THE EXTENT THAT APPLICABLE LAW PROHIBITS SUCH
LIMITATION. FURTHERMORE, BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION, IF APPLICABLE, MAY NOT APPLY TO PURCHASER.
Applicability. The limitations and exclusions contained herein shall apply notwithstanding any failure of essential purpose of any limited remedy.
26
Attachment А
Order sheet of modes operation and functions of the devices:
PM1703М-О, PM1703М-О1, PM1703М-О1A, PM1703МА, PM1703МВ,
PM1703GNО, PM1703GNА, PM1703GNВ,
Modes and functions
On/off
---------set value
Note
Search mode (gamma, indication "s-1")
Measurement mode
(indication µSv/h)
Measurement mode
(indication µR/h)
Gamma registration mode:
Modes of storage of counting pulse (gamma,
indications-1) and average count rate at storage time
Can be ON autonomous or combined with modes 2 or 3
Can be ON autonomous or combined with modes 1 or 5
Mode 0…..9:
Mode of relative indication (0-9)
Can be ON autonomous or combined with modes 2 or 3
Auto calibration
Impossible in mode 5
Possible only in combining of modes 1 and 2
Or 1 and 3
Installation of thresholds DER for mode 5
- Search threshold
Search in measurement mode
- threshold DER (threshold of safety)
10
Installation of thresholds DER for modes 1-3
- threshold DER (threshold of safety))
Switch Audio/Vibr:
Fast switch of alarm mode:
audio-light or vibr-light
11
Changing of volume level:
Can be ON autonomous or combined with modes 1 or 5
Only for device PM1703М-О1
Can be ON additionally to modes 1, 2 or 3
threshold: 15 – 7777 µR/h (0.15-77.77µSv/h)
advisable30µR/h (0,3 µSv/h)
threshold 10 – 7000 µR/h (0,1-70 µSv/h)
advisable - 3mR/h (30 µSv/h)
threshold- 1 – 7000 µR/h (0.01 – 70 µSv/h)
advisable- 3mR/h (30 µSv/h)
Возможность быстрого переключения вида сигнализации без входа
в режим установок
Possibility of change of volume level of audio alarm in settings mode
Adjustment of level of audio alarm by buttons
27
Additional for GN - devices
12
13
Registration mode of neutrons:
Modes of storage of counting pulse (neutrons,
indication S-1) and average count rate at storage time
Neutron threshold:
Setting of set threshold count (neutrons)
Only for mode 5
threshold: 1.0 - 99.0 s-1 (with interval 0.5)
advisable - 1,5 s-1
Additional settings
14
15
16
17
18
19
20
21
Interval of history record, min
Resolution of coefficient variation n
Coefficient n (gamma)
Coefficient n (neutron)
Resolution of alarm variation
Audio alarm
Vibration alarm
Resolution of thresholds variation
Advisable 5.3
Advisable 5.0
Only for mode 5
28

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 28
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2006:09:28 11:04:38
Modify Date                     : 2006:09:28 11:04:38
Title                           : Microsoft Word - 1703 user manual.doc
Creator                         : PScript5.dll Version 5.2
Author                          : Daveg
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UJ6PM1703SERIES

Navigation menu