Poly Habitat Soundscaping Enclosed Waterfall Installation Guide USCAN 2017Early 2018
User Manual: Poly Habitat Soundscaping Support | Poly, formerly Plantronics & Polycom
Open the PDF directly: View PDF
.
Page Count: 23
| Download | |
| Open PDF In Browser | View PDF |
Enclosed Waterfall Installation Guide INSTALLATION + MAINTENANCE Enclosed Waterfall What you need for installation 3 What’s in the box 3 Uncrate the waterfall 4 Waterfall overview 5 Installation 6 First-time operation 9 Lighting operation (optional) 11 General operation: Valve overview 12 Troubleshooting 13 Surface cleaning and maintenance 14 Quarterly water maintenance 15 6-Month water maintenance 15 Yearly water maintenance 16 Yearly component replacement Component replacement Glossary 17 18 19 Specifications 20 Safety certifications 21 Revision date: 6.27.18 CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 2 Enclosed Waterfall What you need for installation • 4 people to help move and position waterfall • Distilled water • 14 gallons of distilled water for 8 x 4 ft. waterfall • 18 gallons of distilled water for 9 x 5 ft. and 10 x 5 ft. waterfalls REQUIRED • • • • • • • • • • • • • Distilled water is absolutely required no tap water, no spring water. Safety gloves Latex gloves (optional) Electric drill No. 2 Phillips bit Bit holder Pair of platform dollies Liquid level Ladder or scissor lift Phillips screw driver Tablespoon measuring spoon Access to 120VAC 20 AMP Duplex outlet (US Standard outlet) Extension cord (optional) Rubber mallet What’s in the box Standard Components Waterfall Oase® water pump (assembled) UV (Ultraviolet) sterilizer UV bulb and sleeve Plastic funnel Fill insert Tubing Weimans® stainless steel wipes Novus acrylic cleaner Plumber tape Leveling shims Power strip Suction cup glass holders Microfiber cloth Robelle Oxidizing Shock & Swim Monopersulfate (1 lb. bag) Optional components 39” LED lighting fixture Remote control with batteries CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 3 Enclosed Waterfall Uncrate the waterfall Uncrate the shipping container Your waterfall ships inside of a wooden crate to protect the waterfall from damage. Your container indicates which side is the front of the waterfall. 1. Position the package so that the front is facing towards the ceiling. 2. Starting with the front panel of the shipping container, use the drill with the No. 2 Phillips bit to remove all of the screws. 3. Remove the cardboard. The waterfall is wrapped in plastic and surrounded by protective insulation foam. Remove the top layer of insulation foam, but do not throw it away. You can reuse the foam to protect the stainless steel while you move it into its final position. 4. Remove the remaining wooden panel pieces and cardboard from the shipping container. 5. Once all of the wood is removed, lift the waterfall to a standing position. Leave the metal header off until the waterfall is in its final position. CAUTION Because the waterfall is very heavy, it is best to use four people to move and position it. 6. Use the platform dollies to move the waterfall near its final location, if necessary. • To position the dollies under the base, tip the base on one of the short edges. Roll one of the platform dollies under the lifted base edge. Lower the base onto the platform dolly and carefully tilt the waterfall so that the other dolly can be rolled underneath the opposite side. Move the waterfall nearest to the final location as possible. • To remove from dollies, lift one side of the waterfall, remove a dolly then rest the base onto the floor. Do the same for the other side. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 4 Enclosed Waterfall Waterfall overview Quick disconnects Spray bar HEADER WATERFALL PANEL Fill valve Primary control valve (intensity) Water pump valve Water pump Drain valve LED light fixture BASE VIEW FROM TOP UV sterilizer lamp housing UV outlet valve UV inlet valve CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 5 Enclosed Waterfall Installation Position the waterfall Use a platform dolly under each end of the waterfall to move the waterfall into position easily. Take the waterfall off the dollies and slide into its final position. Level the waterfall If the waterfall is not level, use shims to level the waterfall. 1. Placing the level on the waterfall base lid, slightly tilt the waterfall and insert the thinnest end of a shim between the floor and the bottom of the waterfall unit. Check the level again. Use a mallet to tap the shim further into the underside of the base, if necessary. Repeat the process until the base is level on all sides. 2. Once the base is level, break off or cut the exposed ends of the shims. 3. Place the header on top of the water fall. NOTE Because the header is heavy, it is best to use two people to move and position it. Install bulb in UV Using the suction cup glass holders, remove the base lids. Remove all packaging inside the base. The waterfall ships with the plumbing installed except the UV bulb and bulb sleeve to prevent damage during transit. 1. To install the bulb and sleeve, unscrew the ballast from the lamp housing. Ballast CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 6 Enclosed Waterfall Installation 2. Wearing gloves or holding the bulb with a cloth (avoid touching the bulb; oils from your skin will reduce the bulb lifespan), align the center groove on the bulb with the pin on the inside of the ballast. 3. Push the bulb in firmly. 4. Slide the bulb sleeve over the bulb until the rubber ring touches the ballast housing. 5. Slide the bulb into the lamp housing. Screw the ballast back into the lamp housing until it is hand tight. Do not overtighten! 6. Screw the lamp housing back into the base plumbing. 7. Do a quick check to make sure the UV light powers on. Look for the three translucent rings to light up. Do not leave the light on for more than 10 seconds. If it doesn’t illuminate, unscrew the ballast and check to make sure the sleeve and bulb are correctly in place. Chase cables to power Chase or run the cables for the water pump, UV sterilizer, and lighting fixture (if purchased) out of the small hole on the side/back of the waterfall base. Ensure the cords reach the outlet. If the cords don’t reach, use a power strip and an extension cord. CAUTION Do not plug in any components until you’ve filled the panel with water. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 7 Enclosed Waterfall Installation 1. Ensure the drain valve is closed (perpendicular to pipe). Drain VIEW FROM REAR 2. Connect the fill insert spout and funnel (supplied) into the fill valve. 3. Open the fill valve (parallel to pipe). CAUTION Protect your waterfall and make sure to add the water treatment before running for the first time. Treat the water 4. Pour one tablespoon of monopersulfate powdered water treatment (provided with purchase) into the funnel, which will dissolve as you add the distilled water. We recommend “Robelle Oxidizing Shock & Swim Monopersulfate.” NOTE Treat water with 1 tablespoon monopersulfate every 6 months. See maintenance instructions on p. 15. CAUTION Do not treat with any other additives or solutions including chlorine, bromine, or cleaning solvents/solutions. Fill with distilled water 5. Using distilled water only, fill the panel until the water is 10 inches from the bottom of the panel (5 inches above the base lid). NOTE: The minimum water fill line indicator is located on the clear acrylic panel near the water fill valve. REQUIRED Model # G048 G059/G060 Distilled water is required. Do not use tap water or spring water. Dimension 4 x 8 ft. 5 x 9 ft. / 5 x 10 ft. Water 14 gallons distilled water 18 gallons distilled water 6. Close fill valve before removing funnel and insert. Have towels on hand for any spills. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 8 Enclosed Waterfall First-time operation Double-check valve position Ensure the valves are in the following positions: Valve Position Drain valve Closed (perpendicular to pipe) Primary control valve Open (parallel to pipe) Water pump valve Open (parallel to pipe) Fill valve Closed (perpendicular to pipe) UV inlet valve Open (parallel to pipe) UV outlet valve Open (parallel to pipe) Connect power Connect all cables to standard US outlet or supplied power strip. There are 3 cables with the optional lighting fixture, or 2 without it. The waterfall and lighting fixture will power on. Check for leaks 1. Evaluate the waterfall and check for leaks. 2. If you notice any leaks, immediately disconnect power from the waterfall. 3. Attempt to locate the source of the leak. 4. If the quick disconnect fittings above the spray bar are leaking, tighten them. 5. If the leak is coming from elsewhere, call us at 847-679-6666. QUICK DISCONNECTS FROM ABOVE CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 9 Enclosed Waterfall First-time operation Adjust the flow Two valves control the flow of water and must be adjusted to balance the flow at the top and base of the panel. Primary control valve VIEW FROM REAR • • UV inlet valve Adjust the primary control valve to control the water flow through the spray bar to create the waterfall effect. Adjust to ensure that there are no dry spots on the panel. Adjust the UV inlet valve flow until the fountain effect protrudes approximately 1 inch above the water line on the left bottom side of the panel. Fountain effect 1 inch above waterline Adjust lighting If you have the optional lighting fixture, use the remote control to customize the lighting. See pg 11. Seal the waterfall Replace the header and base lids once you are satisfied with the water flow and lighting. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 10 Enclosed Waterfall Lighting operation (optional) The optional lighting fixture is installed in the base, just below the enclosed acrylic waterfall panel. Remote control Your unit includes an infrared lighting remote control. For best performance, stand close to the waterfall and aim the remote control down towards the lighting fixture in the base. Select color or program Press PROG to go into color program select mode. Press “+” or “-” to cycle through the 24 built-in programs (8 static colors, 8 color dreaming modes and 8 color changing modes). aim remote control down towards base Presets Press button 0 - 9 to choose a static color and the two built-in programs: 0: black 1: red 2: green 3: blue 4: cyan 5: yellow 6: purple 7: white 8: color changing mode 9: color dreaming mode Recommended presets We recommend the following for office use: color program 7: white 4: cyan 9: color dreaming mode benefits energize and focus calm and productive creativity and visual stimulation Select brightness Press R/G/B and press “+” and “-” buttons to adjust the intensity of the lighting. Select Auto Run mode Not recommended. Press “AUTO RUN” to choose Auto Run/demo mode. Press FLASH to turn on/off the flash for the Auto Run, and then pressing “+” and “-“ buttons to adjust flash speed. Press SPEED to control the speed of the Auto Run, and then pressing “+” and “-” buttons to adjust it. Select flash/ strobe effect Not recommended. Press FLASH to turn on/off strobe effect and press “+” or “-” to adjust the flash speed. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 11 Enclosed Waterfall General operation: Valve overview Primary control valve: Modifies the intensity of waterfall. This valve controls the water flow through the spray bar. UV inlet valve: Controls the water flow through the UV sterilizer and to the fountain feature at the base of the enclosed panel. UV outlet valve: Keep open (parallel to pipe) unless you are servicing the UV sterilizer. Water pump valve: Keep open (parallel to pipe) unless you are servicing the water pump. Fill valve: Keep closed (perpendicular to pipe) unless you are filling the waterfall. Drain valve: Keep closed (perpendicular to pipe) unless you are draining the waterfall. Fill valve Drain valve Primary control valve Water pump valve VIEW FROM REAR UV outlet valve UV inlet valve CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 12 Enclosed Waterfall Troubleshooting Symptom Problem Solution Uneven water flow Dry spots on panel Water flow is too low. Adjust the primary control valve to increase flow to the spray bar. Pump is loud/ has sucking sound There is not enough water inside the panel Fill panel with more distilled water if the water level is less than 4” above the base lid when waterfall is powered on. (See page 8) 4 inches Pump unresponsive Pump auto start off Ensure there is enough distilled water in the panel. Without adequate water, the pump will suck in air and produce bubbles or interruptions in the water supply to the header. Leaking water Leaking water Immediately disconnect power to the waterfall. Tighten all disconnect fittings above the spray bar. Check seal at top of enclosed panel and ensure screws are fully tightened. Lighting unresponsive Batteries are depleted Replace batteries in the remote control. Signal interrupted You may be too far away from the light fixture when using the remote control: • Stand close to the waterfall and aim the remote control downward at the base The base lids may be interrupting the signal: • Remove base lids before using remote control CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 13 Enclosed Waterfall Surface Cleaning and Maintenance Cleaning acrylic CAUTION Do not use Windex® or any ammonia-based cleaning product. It will damage the waterfall’s acrylic surface. CAUTION Use only a clean microfiber cloth to wipe the acrylic surface. Other materials may damage the surface. Use a clean microfiber cloth to remove blemishes such as fingerprints and dust. For tougher stains, use: • Novus acrylic cleaner or • Dish-detergent-and-water mixture and clean microfiber cloth We recommend Novus acrylic cleaner, a 3-part product for general cleaning, scratch removing and polishing. Follow package instructions. Cleaning stainless steel We recommend Weimans® Stainless Steel Cleaner. Follow package instructions. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 14 Enclosed Waterfall Quarterly Water Maintenance Check water level every three months and refill with distilled water if the water level is less than 4” above the base lid when waterfall is powered on. REQUIRED Distilled water is required. Do not use tap water or spring water. 6-Month Water Maintenance 1. Disconnect the waterfall from power. 2. Ensure the drain valve is closed (perpendicular to pipe). Fill valve Drain valve VIEW FROM REAR 3. Connect the fill insert spout and funnel (supplied) into the fill valve. 4. Open the fill valve (parallel to pipe). 5. Pour one tablespoon of monopersulfate powdered water treatment into the funnel, which will dissolve as you add the distilled water. We recommend “Robelle Oxidizing Shock & Swim Monopersulfate.” CAUTION: Do not treat with any other additives or solutions including chlorine, bromine, or cleaning solvents/solutions. 6. Use funnel to add distilled water to 10 inches above the bottom of the panel (5 inches above the base lid). 7. Close fill valve before removing funnel and insert. Have towels on hand for any spills. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 15 Enclosed Waterfall Yearly Water Maintenance For optimum performance, replace the water with fresh distilled water and water treatment annually. REQUIRED Drain the waterfall Distilled water is required. Do not use tap water or spring water. 1. Disconnect power to the waterfall 2. Prepare buckets for waste water 3. Remove front base lid 4. Connect the drain fitting to the drain insert and tubing (supplied) or to a hose. 5. Open the drain valve (parallel to pipe) 6. Drain the unit by siphoning manually or buying and using a pump. Add water treatment and distilled water 1. Close the drain valve (perpendicular to pipe). 2. See pg 8 for water filling instructions and water quantity. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 16 Enclosed Waterfall Yearly component replacement CAUTION UV sterilizer bulb (replace yearly) Disconnect all cables from power when servicing the waterfall. Pondmaster® UV Sterilizer • • • • • • For optimum performance, replace bulb once every year. It should remain on 24 hours per day throughout the year. The bulb has a lifespan of 9000 hours before the UV output drops below a useful level. The UV sterilizer housing has 3 rings that will glow blue if the bulb is still producing UV wavelength. The bulb will produce visible light long after it has stopped producing UV. The valves on the UV sterilizer should remain in the on (parallel to plumbing) position until you are ready to change UV sterilizer or service the bulb. Yearly bulb replacement You will need: towels, bucket 1. Disconnect power to the waterfall 2. Turn both UV valves to the OFF position (perpendicular to plumbing). This will prevent water from draining from the waterfall while servicing. Water will be inside the UV fixture, so have towels on hand. 3. Loosen the union valves at the ends of the UV to disconnect UV fixture from waterfall. 4. Carefully remove from base and discard the leftover water into a bucket or drain. 5. See instructions on page 7 to replace the UV bulb. Union valve For replacement parts contact: Danner Mfg. Inc. Islandia, New York 11749-1489 (631) 234-5261 www.dannermfg.com or www.amazon.com CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 17 Enclosed Waterfall Component replacement Pump (replace as needed) Because you are using distilled water inside of an enclosed waterfall, your waterfall pump requires little maintenance; however should your pump fall outside of warranty, you will need to replace it. To replace the pump: You will need: towels, bucket, plumbers tape 1. Disconnect power to the waterfall. 2. Remove front base lid. 3. Turn the primary control and water pump valves to the OFF position (perpendicular to pipe). This will prevent water from draining from the waterfall while servicing. However water will be inside the pump, so have towels on hand. 4. Remove the quick disconnects at the inlet and outlet of the waterfall pump. 5. Carefully remove pump from base and discard the leftover water into a bucket or drain. 6. Remove the plumbing connections and transfer them to the replacement pump. 7. Use plumbers tape on the threads of the new pump before transferring the piping to the new pump. 8. Ensure the piping is tightly threaded onto the new pump before reconnecting to the quick disconnects. 9. Turn the water supply and water pump valves to the ON position (parallel to pipe). 10. Check for leaks around the pump. Tighten fittings. 11. Connect power to the waterfall and test. CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 18 Enclosed Waterfall Glossary • Base The stainless steel enclosure that holds the plumbing assembly and optional lighting fixture. • Base lids The base lids conceal the base. To prevent damage to stainless steel, remove and replace the lids using suction cup glass holders. • Header The stainless steel cover for the acrylic panel top, spray bar and plumbing components above the waterfall panel. • Plumbing assembly Includes pump, UV sterilizer, flow control valves, drain fittings, routing. • Enclosed panel The water-tight reservoir is the focal point of the waterfall. • Drain Valved connection that releases water from waterfall panel. Header Enclosed panel Drain Base lids Base Plumbing assembly VIEW FROM REAR CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 19 Enclosed Waterfall Specifications Enclosed waterfall • Clear acrylic, enclosed panel waterfall • Low maintenance unit • 39” LED color changing RGB lighting with remote control (optional) • Ultraviolet sterilizer to keep water clean • Silent pump operation • No plumbing required Oase® Profinaut 6000 Waterfall Pump (9 x 5 ft., 10 x 5 ft.) • Power requirements 120 V / 60 Hz Oase® Neptun 2600 Waterfall Pump (8 x 4 ft.) • Power requirements 120 V / 60 Hz Pondmaster® UV Sterilizer • 40 watt output • Power consumption 720 W • Power consumption 220 W • Max flow rate to kill bacteria 2000 GPH • Input power 120/220v 39” LED lighting fixture with remote control • Power consumption 80 watts • 18 super bright 3 watt tri-color (3 in 1) LEDs • Beam angle: 40 degree • Control mode: receiving IR signal • Outdoor rated ip65 • Aluminum construction CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 20 Enclosed Waterfall Safety Certifications Oase® Profinaut 6000 Waterfall Pump Oase® Neptun 2600 Waterfall PumpCertification Record Certification Record Customer Customer OASE GmbH Aquamax 1600 SF Tecklenburger Strasse 161, OASE GmbH Hörstel Aquamax 2200 1600 SF Aquamax SF Tecklenburger Strasse Germany 161, 48477 Hörstel Aquamax 3000 2200 SF SF Aquamax Germany Class CSA File Number Class 3851-81 0.75 1600 LIQUID PUMPS-Certified to US Standards 3851-81 0.75 1600 to US 1.4 2200 LIQUID PUMPS-Certified Standards CSA File 215573 10 ft,Number 6 in. 1.4 1.8 11 ft, 6 in. 15 2200 3000 215573 10 ft, 6 in. 11 48477 Submersible or non submersible Fountain Pump, grounded, cord connected. All pumps are Aquamax 3000 SF 1.8 3000 15 ft, 6 in. Aquamax 3500 SF 2.6 3500 19 rated 120 V, 60 Hz Certified in accordance with: UL 778 fourth ed, Motor Operated Water Pumps, and power and Submersible or non submersible Fountain Pump, grounded, cord connected. All pumps are types as indicated below and power and types as indicated below rated 120 V, 60 Hz Aquamax 6000 3500 SF 2.6 3500 19 Aquamax 4.4 6000 15 Certified in accordance with: UL 778 fourth ed, Motor Operated Water Pumps, and power and types as indicated below and power and types as indicated below Aquamax 6000 Model 4.4 Current (A) 6000 Q max. (Gph) 15 Max. Height (feet) UWP Model150 Neptun 1600 2.4 Current (A) 0.8 2400 Q max. (Gph) 1600 28 Max. Height (feet) 15 ft, 6 in. UWP 150 Profinaut 6000 Neptun 1600 2.4 6.1 0.8 2400 6100 1600 28 40 15 ft, 6 in. Profinaut 6000 Profimax 7000 Neptun 2600 66.1 2.0 6100 7000 2600 40 28 20 ft Neptun 2600 2.0 2600 20 ft Submersible Filter Pump Model Profimax 7000 6 SwimSkim 25, Household, 7000 grounded, cord 28connected. The Nautilus 1600120 V, 60 Hz, 0,9 0.8A. 1600 15 pump is rated Note: additional a 40 W rating can be added Submersible Filter Pump Model grounded, cord Nautilus 1600 0.8SwimSkim 25, Household, 1600 15connected. The Nautilus 2600120 V, 60 Hz, 0,9 1.9A. 2600 21 pump is rated Note: additional a 40 W rating can be added Nautilus 2600 1.9 2600 21 Submersible or non submersible Fountain Pump, grounded, cord connected. All pumps are rated 120 V, 60 Hz Submersible or non submersible Fountain Pump, grounded, cord connected. All pumps are rated and power and types as indicated below 120 V, 60 Hz and power and types as indicated below CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 21 Enclosed Waterfall Listing Constructional Data Report (CDR) Safety Certifications 1.0 Reference and Address Report Number 100816416DAL-001 Original Issued: 29-Aug-2012 Revised: 4-Sep-2012 39” LED lighting fixture UL Standard for Safety for Luminaires, ANSI/UL 1598 and CAN/CSA C22.2#250.0, Third Standard(s) Model # HE-YLL-032-0.5M-ETL Edition, Issued: Sep 17, 2008, Revised: Jan 11, 2010 Guangzhou Huayao Electronics Co. Ltd. Listing Constructional Data Report (CDR) 4016 Harry Hines Blvd No. 70, Yuangang Road, Tianhe Address Address Dallas, TX 75219 District, Guangzhou 510650, China USA China Country Country Mr.Address Mark Reed-Walkup James Zhong Contact Contact 1.0 Reference and 650-1855 86-020-37089936 Phone Phone 100816416DAL-001 Report Number (972) Original Issued: 29-Aug-2012 Revised: 4-Sep-2012 (972) 767-3299 86-020-37093748 FAX FAX UL Standard for Safety for Luminaires, ANSI/UL 1598 and CAN/CSA C22.2#250.0, Third Standard(s) mark@wdmlighting.com Email Email Edition, Issued: Sep 17, 2008, Revised: Jan 11, 2010 james@highendled.com Applicant Wiedamark LLC Manufacturer Applicant Wiedamark LLC Manufacturer Address Country Contact Phone FAX Email 4016 Harry Hines Blvd Dallas, TX 75219 USA Mr. Mark Reed-Walkup (972) 650-1855 (972) 767-3299 mark@wdmlighting.com Address Country Contact Phone FAX Email Guangzhou Huayao Electronics Co. Ltd. No. 70, Yuangang Road, Tianhe District, Guangzhou 510650, China China James Zhong 86-020-37089936 86-020-37093748 james@highendled.com Page 1 of 18 CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 22 Enclosed Waterfall Safety Certifications Pondmaster® UV Sterilizer Model # UPC 02940 CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 23
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02 Create Date : 2018:06:27 14:46:33-07:00 Metadata Date : 2018:06:27 14:46:39-07:00 Modify Date : 2018:06:27 14:46:39-07:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Instance ID : uuid:09babbd5-6207-f142-808e-f7bc5aa30b85 Original Document ID : xmp.did:519c2dcc-48e4-5845-9ee6-35039e00e444 Document ID : xmp.id:e54a0ed3-b116-4245-adf6-4421e6e589a3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:55d241e3-50d4-4c88-a1e9-43029959763d Derived From Document ID : xmp.did:4eabf954-765d-4b66-b805-00d89ccfe945 Derived From Original Document ID: xmp.did:519c2dcc-48e4-5845-9ee6-35039e00e444 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2018:06:27 14:46:33-07:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 23 Creator : Adobe InDesign CC 2014 (Macintosh)EXIF Metadata provided by EXIF.tools