Pools Spas 2002 Highlife Pre Delivery Addendum 61781 HSS Del Rev B 02 User Manual
2017-03-28
User Manual: Pools Spas 2002-Highlife-Pre-Delivery-Addendum
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. Pre-Delivery Instructions lease take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your new spa. The following sections are guidelines on how to prepare for delivery and set-up of your new spa. Specifically covered are site selection, delivery access, ground preparation, and electrical requirements. P Remember to carefully read the Owner’s Manual that accompanies your spa, and to complete the warranty card within 10 days of delivery. These items, along with other valuable information, will be found in the Owner’s Package which has been placed in the equipment compartment of your spa, where you will also find its serial number. Watkins Manufacturing Corporation reserves the right to change features, specifications and design without notification and without incurring any obligation. DATE PURCHASED: __________________________________________________________________________ DATE INSTALLED:______________________________________________________________________________ DEALER:______________________________________________________________________________________ ADDRESS: ____________________________________________________________________________________ TELEPHONE:__________________________________________________________________________________ n most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your Hot Spring spa is equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers and as a result, is usually exempt from most barrier requirements. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your Hot Spring dealer can provide information on which permits may be required. I x Hot Spring Spa Pre-Delivery Page x Instructions x Site Selection and Preparation IMPORTANT: Site selection and preparation are your responsibility. Carefully read these instructions and consult your authorized Hot Spring® dealer if you have any questions. You probably have a spot picked out for your new spa, whether it’s indoors or outdoors, on a patio or on a deck. Just make sure you check the following: • Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal. Make certain that the location you choose can support the weight of your filled spa. • Don’t forget to level your spa before filling it. (See Spa Leveling Instructions included in Owner’s Manual.) • Locate your equipment compartment, which houses all of the electrical components, in a place where water will drain away from it. Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house’s circuit breaker. • Leave yourself easy access to the circuit breakers in the subpanel (230 volt models), or to the interrupter switch on the end of the power cord (115 volt models). • Never let water get into the subpanel (230 volt models), into the interrupter switch (115 volt models), or into the electrical outlet that your spa is plugged into. Your 115 volt Hot Spring spa will come with a protective box designed to keep out rain and water from sprinkler systems. Your 230 volt spa’s subpanel is raintight when installed correctly with the door closed. • Leave access to the equipment compartment for periodic spa care and maintenance. OUTDOOR AND PATIO INSTALLATION No matter where you install your new spa, it’s important that you have a solid foundation to support it. Structural damage to the spa resulting from incorrect installation or placement on an inadequate foundation is not covered under the spa’s limited warranty. If you install the spa outdoors, a reinforced concrete pad at least four inches thick is required for the Landmark® and Grandee® spas, and recommended for the Vanguard®, Sovereign®, Prodigy® and Jetsetter® spas. All Hot Spring spas may be installed onto a deck, provided that the load capacity of the deck is greater than the dead weight of the spa (see Deck Installation). The reinforcing rod or mesh in the pad should be attached to a bond wire (see your Owner’s Manual). If you place the spa on the ground, even temporarily, place stepping stones under the leveling areas (see Spa Leveling Instructions in your Owner’s Manual). The stones should be at least two inches thick and twelve inches square. Even with stones in place, the spa will inevitably settle and become unlevel. Plus, a spa surrounded by dirt or grass will soon be filled with dirt or grass from users’ feet; therefore, it is important to get it onto a solid foundation as soon as possible. DECK INSTALLATION To be certain your deck can support your spa, you must know the deck’s maximum load capacity. Consult a qualified building contractor or structural engineer before you place the spa on an elevated deck or indoors. To find the weight of your spa, its contents and occupants, refer to the Spa Specification chart. This weight per square foot must not exceed the structure’s rated capacity, or serious structural damage could result. INDOOR INSTALLATION Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring materials must provide a good grip when wet. Proper drainage is essential to prevent a build-up of water around the spa. When building a new room for the spa, it is recommended that a floor drain be installed. The humidity will naturally increase with the spa installed. Water may get into woodwork and produce dryrot, mildew, or other problems. Check for airborne moisture’s effects on exposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to determine if more ventilation must be installed. Your Hot Spring dealer can help you with local information such as zoning regulations and building codes. x Pre-Delivery Instructions Page 2 x x DELIVERY ACCESS First, locate the dimensions of your spa on the following chart. The dimensions shown are the measurements of the spa in the vertical position, laid on its side. Next, contact your dealer to find the height and width added by the delivery cart which the dealer will use to deliver your new spa. Use the height of the cart plus the dimension shown as H to determine the vertical clearance required to pass the spa and cart. Use the width of the cart, or dimension W, whichever is greater, to determine the maximum width of clearance necessary. NOTE: It may be necessary to allow for additional over-head clearance if the spa will be rolled up or down an incline or moved up or down a short flight of stairs. Use the information below to determine the requirements for access to your desired location. Model Width W Length L Height H Landmark® (S) 38” 8’ 4” 7’ 7” Grandee® (G) 38” 8’ 4” 7’ 7” Vanguard® (V) 36” 7’ 3” 7’ 3” Sovereign® 6’ 8” 36” 7’ 9” Sovereign® (I) (ILE) 33” 7’ 9” 6’ 8” Prodigy® (H) 33” 7’ 3” 6’ 2” Jetsetter® (J) 29” 6’ 10” 5’ 2” How is your width clearance? BACK YARD Check all gates Protruding electric meters Gas meters A/C units Do you have sufficient overhead clearance? Check low roof eaves, overhanging branches, rain gutters HOUSE Is the path clear? Move away branches, dog houses, firewood, etc. If there is a 90 turn, can we clear it? (The spa will not bend) No more than 6 consecutive stairs without a landing STREET x Page 3 x Pre-Delivery Instructions x It may be necessary to remove a gate, part of a fence, or other movable obstructions in order to roll the spa to its installation site. About ten percent of the time, a crane is the only way to install the spa by lifting it to its final destination. If the spa has to be taken off of the cart to go over a wall (either because the entry area is too narrow, the eaves are too low, the corner is too tight, or the stairway is too steep), a crane will be required. Don’t be alarmed! The crane has a truck-mounted boom which can fit right in your driveway. It is run by a licensed and insured operator. For a charge, the crane operator will lift your spa over walls, buildings, or any other obstruction and place it as close to the installation site as possible. The Hot Spring® spa delivery personnel will supervise the crane delivery and complete the spa installation. Crane delivery typically takes an average of 30 minutes to complete. NOTE: If your spa delivery requires the use of a crane, you may be required to pay for its services at the completion of the delivery. GROUND PREPARATION Your Hot Spring spa has been engineered to perform on all kinds of common yard surfaces. While a concrete slab is best for long-term use*, other foundations are acceptable so long as a level base is prepared prior to delivery. Three foundation base pictures, shown at right, represent examples of alternatives to a concrete slab for spas installed without gazebos or other accessories. *NOTE: A reinforced concrete pad at least four inches thick is required for the Landmark® and Grandee® spas, and recommended for the Vanguard®, Sovereign®, Prodigy® and Jetsetter® spas. FOUNDATIONS FOR SPAS ONLY (No accessories such as cover or gazebo) PEA GRAVEL OR CRUSHED ROCK INSTALLATION NOTES: • If stepping stones or railroad ties are selected for the spa foundation, they should be placed at the designated leveling areas of your spa to maintain even distribution of the spa weight. • It is important to note that soft surfaces, even when stepping stones are used to distribute the weight of the spa as evenly as possible, will still have a tendency to settle unevenly, resulting in an unlevel spa. • Remember, placing the spa on grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user’s feet. If you are purchasing a deck package or a gazebo with your spa, a solid foundation becomes mandatory. Placing them on any surface other than a single level pad could create problems with their installation. Pictured at right are a few of the recommended surfaces. RAILROAD TIES PRE-CAST STEPPING STONES FOUNDATIONS FOR SPAS WITH ACCESSORIES CONCRETE PADS As a homeowner, it is your responsibility to provide a suitable, level foundation for your spa. Keep in mind that most delivery crews are not equipped to level and prepare spa sites. If you are interested in having a concrete slab, brick surface, or wood deck installed, your Hot Spring dealer should be able to suggest a qualified, licensed contractor. NOTE: In order for the spa to operate properly and the internal plumbing to drain completely, you must ensure that the spa is leveled after it has been installed. The diagrams on the following pages indicate the recommended shimming points on your spa’s base support system. Your Hot Spring spa delivery crew can help you perform the procedure. Pre-Delivery Instructions Page 4 BRICK SURFACES WOOD DECKING Landmark® (Model S) Dimensions 24" (61 cm) 33 3/4" (85.7 cm) MAIN DRAIN 41 3/4" (106 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 48 1/4" (122.5 cm) 38" (96.5 cm) 34 1/2" (87.6 cm) 3 1/2" (8.9 cm) 23 1/2" (60 cm) (Front view) 26" (66 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. 65" (165 cm) SECONDARY DRAIN 91" (2.31 m) 24 1/4" (61.6 cm) U PS ID E (Bottom view) 19" (48.3 cm) D O W N VI EW O F SP A 19" (48.3 cm) 24 1/4" (61.6 cm) 69 (175.3 cm) 52 1/2" (133.3 cm) 42 1/2" (108 cm) 100" (2.54 m) DOOR SIDE NOTE: Watkins Manufacturing Corporation requires that the Landmark be installed on a minimum 4” thick reinforced concrete pad. WARNING: The Landmark must not be shimmed in any manner. x Page 5 x Pre-Delivery Instructions x Grandee® (Model G) Dimensions 23 1/2" (59.7 cm) 33" (83.8 cm) MAIN DRAIN 41" (104.8 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 48 1/4" (122.6 cm) 38" (96.5 cm) 26" (66 cm) 3 1/2" (8.9 cm) 23 1/2" (60 cm) (Front view) 34 1/2" (87.6 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. 64 1/4" (163.2 cm) SECONDARY DRAIN 91" (2.31 m) 24 1/4" (61.6 cm) U PS ID E (Bottom view) 19" (48.3 cm) D O W N VI EW O F SP A 19" (48.3 cm) 24 1/4" (61.6 cm) 68 1/2" (174.0 cm) 53 1/2" (136 cm) 41 1/2" (105.4 cm) 100" (2.54 m) DOOR SIDE NOTE: Watkins Manufacturing Corporation requires that the Grandee be installed on a minimum 4” thick reinforced concrete pad. WARNING: The Grandee must not be shimmed in any manner. x Pre-Delivery Instructions Page 6 x x Vanguard ® (Model V) Dimensions 19" (48.3 cm) 24" (61 cm) MAIN DRAIN 35 3/4" (90.8 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 37 1/2" (95.3 cm) 54 1/2" (161.3 cm) SECONDARY DRAIN 22 1/4" (56.5 cm) U PS ID E D O 19" (48.3 cm) W N VI EW O F SP A 16 1/2" (42 cm) (Bottom view) 87" (221 cm) 24 1/4" (61.6 cm) 60 1/2" (153.7 cm) 18" (45.7 cm) 18" (45.7 cm) 41 1/2" (105.4 cm) 41 1/2" (105.4 cm) 87" (221 cm) DOOR SIDE • 15 Leveling Points (place shims approx. 18” in from edge, then center middle shims). x Page 7 x Pre-Delivery Instructions x 36" (91.4 cm) 32 1/2" (82.5 cm) 3 1/2" (8.9 cm) 23 1/2" (60 cm) (Front view) 25 1/2" (64.8 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. Sovereign® (Model ILE) Dimensions 19 1/2" (49.5 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 37 1/2" (94 cm) MAIN DRAIN 31 1/2" (80 cm) SECONDARY DRAIN 32" (81.3 cm) 49 1/4" (125.1 cm) 36" (91.4 cm) 25" (63.5 cm) 3 1/2" (8.9 cm) 23 1/4" (59.1 cm) (Front view) 32 1/2" (82.5 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. 57" (144.8 cm) 38" (96.5 cm) 38" (96.5 cm) 18" (46 cm) 18" (46 cm) 93" (2.36 m) O F VI EW D O W N U PS ID E 23 1/4" (59 cm) 20" (50.8 cm) (Bottom view) SP A 20" (50.8 cm) 24 1/4" (61.6 cm) CENTER MIDDLE SHIMS 80" (2.03 m) DOOR SIDE • 15 Leveling Points (place shims approx. 18” in from edge, then center middle shims). x Pre-Delivery Instructions Page 8 x x Sovereign® (Model I) Dimensions 19 1/2" (49.5 cm) 24 1/2" (62.2 cm) MAIN DRAIN 31 1/2" (80 cm) SECONDARY DRAIN 32" (81.3 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 48 1/2" (123.2 cm) 33" (83.8 cm) 22" (55.9 cm) 3 1/2" (8.9 cm) 20 1/4" (51.4 cm) (Front view) 29 1/2" (74.9 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. 57" (144.8 cm) 38" (96.5 cm) 38" (96.5 cm) 18" (46 cm) 18" (46 cm) 93" (2.36 m) O F VI EW D O W N U PS ID E 23 1/4" (59 cm) 20" (50.8 cm) (Bottom view) SP A 20" (50.8 cm) 24 1/4" (61.6 cm) CENTER MIDDLE SHIMS 80" (2.03 m) DOOR SIDE • 15 Leveling Points (place shims approx. 18” in from edge, then center middle shims). Page 9 Pre-Delivery Instructions Prodigy ® (Model H) Dimensions 15" (38 cm) 16 1/4" (41.3 cm) MAIN DRAIN 19 1/2" (49.5 cm) 40 1/4" (102.2 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 33" (83.8 cm) 29 1/4" (74.3 cm) 3 1/2" (8.9 cm) 20 1/4" (51.4 cm) (Front view) 21 3/4" (55.3 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. 43 1/2" (110.5 cm) 54 1/4" (137.8 cm) SECONDARY DRAIN 74" (1.88 m) 15" (28 cm) 19" (48.3 cm) 19" (48.3 cm) 23 1/4" (59 cm) U PS ID E D O W N VI EW 87" (2.21 m) (Bottom view) O F SP A 23 1/4" (59 cm) 15" (28 cm) 70 3/4 (179.7 m) DOOR SIDE 10 Leveling Points (place shims apporx. 15" in from edge.) x Pre-Delivery Instructions Page Page10 x x Jetsetter ® (Model J) Dimensions 25" (63.5 cm) 28" (71.1 cm) 43 1/4" (109.9 cm) SECONDARY DRAIN 29" (73.7 cm) 25 1/2" (63.5 cm) 18" (45.7 cm) 14 1/2" (36.8 cm) 1 3/4" (3.8 cm) ELECTRICAL CUTOUT (location may vary 1/2" (1.3 cm) ) 3 1/2" (8.9 cm) (Front view) 19" (48.3 cm) NOTE: All dimensions are approximate; measure your spa before making critical design or pathway decisions. 45 3/4" (116.2 cm) MAIN DRAIN 62" (157.5 cm) 82" (2.08 m) 15" (38 cm) U PS ID E D O W N (Bottom view) 62" (1.57 m) VI EW 58" (147.3 cm) O F SP A 15" (38 cm) 78" (198.1 cm) 20 3/4" (52.7 cm) 18 1/4" (46.4 cm) 18 1/4" (46.4 cm) 20 3/4" (52.7 cm) DOOR SIDE 10 Leveling Points (place shims apporx. 15" in from edge.) x Page Page11 x Pre-Delivery Instructions x ELECTRICAL REQUIREMENTS To ensure you will have an opportunity to use your spa soon after delivery, it is very important that the required electrical service has been installed. Unless otherwise stipulated by your dealer, THIS IS YOUR RESPONSIBILITY. IMPORTANT: All electrical circuits must be installed by a qualified, licensed electrician. Hot Spring® spas are manufactured in two different electrical versions. The Landmark®, Grandee®, Vanguard® and Sovereign® Limited Edition models are available with a 230 volt continuous heating system. These spas cannot be converted to 115 volt operation. The remaining spa models, the Sovereign®, Prodigy® and Jetsetter® models‚ are available as 115/230 volt convertible heating systems. These models come standard from the factory with 115 volt heating systems; however, with the addition of a subpanel and a control box wiring change, they can be converted to 230 volt operation. See the following sections for the electrical requirements for 115 volt operation, 230 volt operation and 230 volt converted operation. 115 VOLT OPERATION REQUIREMENTS The 115 volt spa requires a dedicated 20 amp, 115 volt circuit. This circuit must be properly wired; that is, it must have a 20 amp GFCI breaker in the main electrical service panel, and #12 AWG wire (including ground wire) and the correct polarity throughout the circuit. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maximum voltage drop of 3% be used when calculating the larger wire size. NOTE: The term “dedicated” means that only the spa operates on the circuit. Each 115 volt model comes equipped with approximately 15 feet of usable power cord. (This is the maximum length allowed by Underwriters Laboratory.) When the spa is installed, the power cord will come out of the bottom of the equipment compartment. In addition to the dedicated 20 amp, 115 volt GFCI protected circuit, your spa requires a 20 amp single receptacle. This receptacle, which contains an outdoor-rated, weather-resistant receptacle cover plate, will be provided to you. The single receptacle and cover plate should be installed by your electrician prior to the delivery of your spa. For your safety, when your electrician is installing the electrical outlet, it should be no closer than five (5) feet and no farther than ten (10) feet from the spa. (Reference National Electric Code 680-6a(1) and 680-41a.) WARNINGS: Do not connect your spa to an extension cord! The 115 volt GFCI switch and the receptacle must be protected from weather and landscape sprinklers–they should never get wet. NOTE: If you require the services of a licensed electrician, your Hot Spring Dealer should be able to suggest one for you. Your Hot Spring spa has been carefully engineered to provide maximum safety against electric shock. Remember, connecting the spa to an improperly wired circuit will negate many of its safety features. 230 VOLT OPERATION REQUIREMENTS All models require a 50 amp, single phase, 230 volt circuit breaker in the main electrical service panel. NOTE: WE RECOMMEND THAT A SUBPANEL BE USED TO SUPPLY POWER AND PROTECT THE SPA. On the Landmark, Grandee, Vanguard and Sovereign® Limited Edition models, the subpanel containing GFCI breakers is included with the spa. On the 230 volt Sovereign, Prodigy and Jetsetter models, the subpanel containing GFCI breakers must be purchased separately. All 230 volt Hot Spring® spas must be wired in accordance with applicable local electrical codes, and all electrical work must be done by a licensed electrician. x Pre-Delivery Instructions Page Page12 x x A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the subpanel, and from the sub-panel to the spa per the appropriate wiring diagram as illustrated below. The grounding conductor must be at least #10 AWG. Your electrician should mount the subpanel in the vicinity of the spa but it should not be closer than five (5) feet from the spa water edge (NEC 680-38 to 41-A-3). INSTALLATION NOTE: After the spa has been installed by the dealer’s delivery crew, your electrician can connect the conduit from the subpanel to the spa’s IQ Landmark® (Model S), Grandee® (Model G) and Vanguard® (Model V) 2020® Control Box and then Sovereign Limited Edition® (Model ILE) 230 volt permanently connected models complete the wiring WARNING! The exact physical location of the terminals connections in the control on the GFCI breaker will vary between manufacturers. box. Connecting the hot wire to the neutral terminal will HEATER GROUND cause irreversible damage to the control box. 230V, 50 Amp, 2–POLE, CIRCUIT BREAKER (NON GFCI) TB1 N 1 L1 #8 AWG WHITE, NUETRAL L2 L2 #12 AWG RED L1 #12 AWG BLUE N #12 AWG WHITE #10 AWG GREEN, GROUND GRD 20A #8 AWG BLUE, L1 50A #8 AWG RED, L2 L2 #10 AWG RED 30A L1 #10 AWG BLUE MAIN SERVICE ELECTRICAL PANEL 2 3 4 5 IMPORTANT NOTE: Two different wiring diagrams are shown: one for Landmark, Grandee and Vanguard models‚ and one for Sovereign, Prodigy and Jetsetter models. Always follow the wiring diagram for your specific model. GROUND #10 AWG GREEN NOTE: Complete step-bystep Installation and Wiring Instructions for all 230 volt Hot Spring models are included in the Owner’s Manual and with each subpanel, which can be obtained from your dealer. WARNING: Removing or bypassing the GFCI breakers in the subpanel at any time will result in an unsafe spa and will void the warranty. NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker. *PROVIDED WITH SPA. NOTE: ALL WIRING SHOULD BE COPPER. Sovereign® (Model I), Prodigy® (Model H) and Jetsetter® (Model J) 230 volt converted models WARNING! The exact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control box. 230V, 50 Amp, 2–POLE, CIRCUIT BREAKER (NON GFCI) TB1 N L1 #8 AWG WHITE, NUETRAL L2 #10 AWG GREEN, GROUND GRD #8 AWG BLUE, L1 50A HEATER GROUND L1 #12 AWG BLUE N #12 AWG WHITE 20A #8 AWG RED, L2 L2 #10 AWG RED L1 #10 AWG BLUE 30A MAIN SERVICE ELECTRICAL PANEL GROUND #10 AWG GREEN LESS THAN 100 FT. See owner’s manual or control box schematic for electrical conversion and connection GRD details. 2 3 4 5 Refer to the Wiring Diagrams to the right for the electrical requirements of the 230 volt models. CONTROL BOX LESS THAN 100 FT. 1 WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maximum voltage drop of 3% be used when calculating the larger wire size. GRD CONTROL BOX NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker. *AVAILABLE FROM DEALER. NOTE: ALL WIRING SHOULD BE COPPER. x Page Page13 x Pre-Delivery Instructions x Landmark® (Model S) 7'7" x 8'4" 2.31m x 2.54m Grandee® (Model G) 7'7" x 8'4" 2.31m x 2.54m Vanguard® (Model V) 7'3" x 7'3" 2.20m x 2.20m Sovereign® Limited Edition (Model ILE) 6'8" x 7'9" 2.03m x 2.36m Sovereign® (Model I ) 6'8" x 7'9" 2.03m x 2.36m Prodigy® (Model H) 6'2" x 7'3" 1.88m x 2.21m Jetsetter® (Model J) 5'2" x 6'10" 1.57m x 2.08m 38" .96 m 38" .96 m 36" .91 m 36" .91 m 33" .84 m 33" .84 m 29" .74 m Ef filtefectiv ra e re He a a (W ter att s) Wa ca ter pa city Dr yw eig ht Fil led we igh t* De ad we igh Ele t* Re ctric qu al ire me nts Fo dim otpri en nt sio ns He igh t Spa Specifications 150 square feet 6,000 525 gallons 1,987 litres 877 lbs. 398 kg. 6,195 lbs. 2,810 kg. 115 lbs. per square foot 230 volt, 50 amp Single phase GFCI protected circuit 150 square feet 6,000 500 gallons 1,893 litres 877 lbs. 398 kg. 6,167 lbs. 2,797 kg. 115 lbs. per square foot 230 volt, 50 amp Single phase GFCI protected circuit 120 square feet 6,000 400 gallons 1,514 litres 686 lbs. 311 kg. 4,988 lbs. 110 lbs. per square foot 230 volt, 50 amp Single phase GFCI protected circuit 365 gallons 1,382 litres 705 lbs. 320 kg. 4,675 lbs. 105 lbs. per square foot 230 volt, 50 amp Single phase GFCI protected circuit 105 lbs. per square foot 115 volt, 20 amp Dedicated GFCI protected circuit or 230 volt, 50 amp Single phase GFCI protected circuit 115 volt, 20 amp Dedicated GFCI protected circuit or 230 volt, 50 amp Single phase GFCI protected circuit 115 volt, 20 amp Dedicated GFCI protected circuit or 230 volt, 50 amp Single phase GFCI protected circuit 2,263 kg. 120 square feet 6,000 90 square feet 1,500 or 6,000 355 gallons 1,344 litres 620 lbs. 4,556 lbs. 281 kg. 2,067 kg. 90 square feet 1,500 or 6,000 325 gallons 1,230 litres 533 lbs. 4,051 lbs. 242 kg. 1,838 kg. 105 lbs. per square foot 90 square feet 1,500 or 6,000 215 gallons 814 litres 365 Lbs. 166 kg. 2,638 lbs. 1,197 kg. 90 lbs. per square foot 2,121 kg. CAUTION: Watkins Manufacturing Corporation suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck. * NOTE: The “Filled weight” and “Dead weight” of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs). x Pre-Delivery Instructions Page Page14 x x CONTRACTOR SUGGESTIONS Electrician Name: ______________________________________________________________________________________ Telephone: ______________________________________________________________________________________ Name: ______________________________________________________________________________________ Telephone: ______________________________________________________________________________________ Masonry Name: ______________________________________________________________________________________ Telephone: ______________________________________________________________________________________ Name: ______________________________________________________________________________________ Telephone: ______________________________________________________________________________________ General Name: ______________________________________________________________________________________ Telephone: ______________________________________________________________________________________ Name: ______________________________________________________________________________________ Telephone: ______________________________________________________________________________________ SERVICES AVAILABLE FROM YOUR HOT SPRING® SPA DEALER Service Cost Pre-Delivery site inspection Deliver spa to installation site Unwrap spa and haul away packaging material Set up & level spa Fill the spa with water Connect the spa to its power source (115 volt models) Explain and test the spa’s operation • Jet system • Moto-Massage® jet • Install and test lamp • Set temperature control Explain the safety features • GFCI • Heater high limit General spa operation & maintenance orientation Water quality and maintenance orientation Adjust the water’s Total Alkalinity, Calcium Hardness and pH Sanitize the water Inspect the spa cover, place on spa Review winterizing instructions Review Owner’s Manual & Warranty Card Follow-up call In-store spa water analysis TOTAL COST x Page Page15 x ______________ ______________ ______________ ______________ ______________ ______________ • Comfort Control® system • Control panel functions • Heater thermal cut-off ______________ ______________ ______________ ______________ ______________ ______________ ______________ ______________ ______________ ______________ Pre-Delivery Instructions x ADDITIONAL PRODUCTS AVAILABLE FROM YOUR HOT SPRING® SPA DEALER • EverFresh® water care system • FreshWater 4-way test strips • FreshWater® III high output ozone purification system • Hot Spring Cover Shield™ • Retractable cover system with clearance requirements • Hot Spring MPS chlorine-free oxidizer • MPS test strips • FreshWater™ • Cover Cradle® - 24” Clearance required Stain and Scale Defense • UpRite® - 7” Clearance required • FreshWater Spa Shine • GlideRite® - 14” Clearance required • FreshWater Instant Filter Cleaner • Vinyl covers • FreshWater Filter Cleaner • Spa vacuums • FreshWater Ph-Alkalinity Down • Spa steps • FreshWater Ph-Alkalinity Up • Stain kits • FreshWater Concentrated Chlorinating Granules • Spa upgrade jet kits • FreshWater Defoamer • Replacement filter cartridges • FreshWater Calcium Hardness Increaser • Pillows WATKINS MANUFACTURING CORPORATION 1280 Park Center Drive Vista, California 92083 (800) 999-4688 extension 432 ©2002 Watkins Manufacturing Corporation. Hot Spring, Built for a lifetime of relaxation, Moto-Massage, Classic, Sovereign, Grandee, Landmark, Prodigy, Jetsetter, Comfort Control, IQ 2020, CoverShield, EverFresh, FreshWater and The Home Relaxation Specialists are trademarks of Watkins Manufacturing Corporation. Part #61781 Rev. B (5/02) x Page x x
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2002:05:08 10:44:01 Producer : Acrobat Distiller 4.05 for Macintosh Creator : QuarkXPressª 4.1: LaserWriter 8 8.7.1 Author : John Title : 61781 HSS Pre-Del Rev B 02 Modify Date : 2002:05:08 10:44:29-07:00 Page Count : 16EXIF Metadata provided by EXIF.tools