Power Measurement ION6100 Low Power Communication Device Transmitter User Manual ION 6100 Installation Guide

Power Measurement Ltd. Low Power Communication Device Transmitter ION 6100 Installation Guide

Manual

Download: Power Measurement ION6100 Low Power Communication Device Transmitter User Manual ION 6100 Installation Guide
Mirror Download [FCC.gov]Power Measurement ION6100 Low Power Communication Device Transmitter User Manual ION 6100 Installation Guide
Document ID457097
Application IDTh5HpWkVyY+UQLk8MWNPTQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize44.27kB (553320 bits)
Date Submitted2004-08-05 00:00:00
Date Available2004-08-05 00:00:00
Creation Date2004-06-18 08:57:15
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-06-18 09:22:40
Document TitleION 6100 Installation Guide
Document CreatorFrameMaker 6.0
Document Author: Power Measurement

Danger
This symbol indicates the presence of dangerous voltage within and outside the product
enclosure that may constitute a risk of electric shock, serious injury or death to persons if
proper precautions are not followed.
Caution
This symbol alerts the user to the presence of hazards that may cause minor or moderate
injury to persons, damage to property or damage to the device itself, if proper precautions are
not followed.
Note
This symbol directs the user’s attention to important installation, operating and maintenance
instructions.
Installation Considerations
Installation and maintenance of the ION 6100 meter should only be performed by qualified, competent
personnel that have appropriate training and experience with high voltage and current devices. The meter
must be installed in accordance with all local and National Electrical Codes.
DANGER
Failure to observe the following instructions may result in severe injury or death.
! During normal operation of the ION
6100 meter, hazardous voltages are present inside its case and on
associated wiring. Follow standard safety precautions while performing any installation or service work
(e.g. opening fuses/breakers).
! There are no user-serviceable parts inside the ION 6100.
CAUTION
Observe the following instructions, or permanent damage to the meter may occur.
! The ION
6100 meter is powered from the line it is monitoring, and has different hardware options that
affect voltage input ratings. The ION 6100 meter’s serial number label lists all equipped options. Applying voltage levels incompatible with the input ratings will permanently damage the meter.
! The ION 6100 meter’s ground wire must be properly connected to earth ground for the noise and surge
protection circuitry to function correctly. Failure to do so will void the warranty.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
! Reorient or relocate the receiving antenna
! Increase the separation between the equipment
and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Modifications: Modifications to this device which are not approved by Power Measurement may void the
authority granted to the user by the FCC to operate this equipment.
Standards Compliance
Certified to UL 916
Limitation of Liability
Power Measurement Ltd. (“Power Measurement”) reserves the right to make changes in the device or its
specifications identified in this document without notice. Power Measurement advises customers to obtain
the latest version of the device specifications before placing orders to verify that the information being
relied upon by the customer is current.
Regardless of whether any remedy set forth herein fails of its essential purpose, except to the extent the
following limitation is prohibited by applicable law, Power Measurement shall not, in any event or under
any legal claim or theory (whether based on contract, indemnity, warranty, tort (including negligence and
strict liability) or otherwise), be liable to the original purchaser or any other person or entity for special,
indirect, incidental, punitive, liquidated, special or consequential damages whatsoever with respect to
any purchased product, including, without limitation, business interruption, loss of use, profit or revenue,
even if Power Measurement has been advised of the possibility of such damages. To the extent that a
limitation or exclusion of consequential damages are prohibited by applicable law, then Power
Measurement’s liability shall be limited to twice the amount of the relevant purchased product. Not to
limit the foregoing, a) Power Measurement shall not be liable for any claim (other than a claim solely for
the breach of one of the above Warranties that is made in accordance with the above described
procedures) made by the original purchaser, its employees, agents, or contractors for any loss, damage,
or expense incurred due to, caused by, or related to any purchased product; and b) the above Warranties
are the original purchaser's exclusive remedy and Power Measurement hereby expressly disclaims all
other warranties, express or implied, including, without limitation, warranties of non-infringement and
the implied warranties of merchantability and fitness for a particular purpose.
These limited Warranties shall not apply to any product that has been subject to alteration, accident,
misuse, abuse, neglect or failure to exactly follow Power Measurement's instructions for operation and
maintenance. Any technical assistance provided by Power Measurement's personnel or representatives
in system design shall be deemed to be a proposal and not a recommendation. The responsibility for
determining the feasibility of such proposals rests with the original purchaser and should be tested by the
original purchaser. It is the original purchaser’s responsibility to determine the suitability of any product
and associated documentation for its purposes. The original purchaser acknowledges that 100% “up”
time is not realizable because of possible hardware or software defects. The original purchaser
recognizes that such defects and failures may cause inaccuracies or malfunctions. Only the terms
expressed in these limited Warranties shall apply and no distributor, corporation or other entity,
individual or employee of Power Measurement or any other entity is authorized to amend, modify or
extend the Warranties in any way.
The information contained in this document is believed to be accurate at the time of publication, however,
Power Measurement assumes no responsibility for any errors which may appear here and reserves the
right to make changes without notice.
Power Measurement, ION, ION 6100, ION Enterprise, MeterM@il, WebMeter and “smart energy
everywhere” are either registered trademarks or trademarks of Power Measurement. All other
trademarks are property of their respective owners.
Covered by one or more of the following patents:
U.S. Patent No's 6694270, 6687627, 6671654, 6671635, 6615147, 6611922, 6611773, 6563697,
6493644, 6397155, 6186842, 6185508, 6000034, 5995911, 5828576, 5736847, 5650936,
D459259, D458863, D443541, D439535, D435471, D432934, D429655, D429533, D427533.
ION 6100 Wireless Energy Meter
The ION® 6100 is a metering and data transmitting component of your ION
enterprise energy management (EEM) system that features a compact design,
pre-wired split-core low-voltage output CTs, and wireless communications,
for quick and easy installation.
Each ION 6100 meter measures power and calculates energy use at its
installed location (load point) inside your building. The data is periodically
sent and transmitted through the other ION 6100 meters in the building,
towards the wireless gateway. The gateway collects and stores the data, then
forwards the data to the EEM server for processing and storage.
Limitations on Wireless Communications
Operating frequency
License-free 900 MHz ISM radio band
Operating range
Typical 30 meter (100 ft) range to other
routers (indoor, line of sight)
The range of wireless communication is reduced when transmitting through
building materials such as concrete or steel. Test results in modern
skyscrapers displayed the ability to communicate reliably from one to three
floors distance between two ION 6100 meters. Ranges up to 50 feet are
typical when transmitting through walls constructed with wood or drywall.
Communication ranges depend on the environment the device is installed in.
Before You Begin
1.
Check to ensure you received the correct meter options, compatible with
the electrical system that your meter will be monitoring. Refer to the
“Available Options” section for details.
CAUTION
Connecting a meter with Voltage Input option “2” (208-240 V) to a 480 V
system will permanently damage the meter.
2.
Read this manual in its entirety. Follow the warnings presented in the
“Installation Considerations” section.
3.
Review the building plans. Check that the wiring/installation plans for the
ION 6100 meters conform to the requirements of the building’s electrical
system.
4.
Coordinate the installation of the ION 6100 meters with the installation
of the gateway. The gateway should be installed first so that the ION
6100s are able to provide communications diagnostics (via the LEDs)
immediately after they are installed.
NOTE
Use the Location ID on the ION 6100 meter label to see where the meter
should be installed (e.g. floor number, panel number).
5.
Recommended tools:
3/8” flat-head screwdriver
Locking pliers
Wire cutter/stripper
Getting More Information
Additional material related to the ION 6100 and other Power Measurement™
products are available online at www.pwrm.com. This manual is also
available in PDF format and can be downloaded from our website.
Available Options
Form Factor Options
Option code
Description
T1
For mounting inside the electrical panel
U1
For mounting outside the electrical panel
Split-Core CT Options)
Option code*
Description
200 A, 0.75” window, low voltage output
400 A, 1.25” window, low voltage output
800 A, 2.00” window, low voltage output
1500 A, 2.00” window, low voltage output
* For other CT options, contact Power Measurement.
Voltage Input Options
Option code
Description
208-240 VLL +/-10%
480 VLL +/-10%
System Type
Option code
Description
S0
WYE, 3 or 4 Wire (comes with 3 CTs)
T0
DELTA, 3 Wire (comes with 3 CTs)
U0
Single Phase (comes with 2 CTs)
System ID**
Option code
Description
A0
System ID #1 (Default gateway transceiver ID)
A1
System ID #2 (Second gateway transceiver ID)
A2
System ID #3 (Third gateway transceiver ID)
** System ID is the radio ID the meter uses to communicate to the gateway.
Typically, option code A0 is used for single gateway applications.
Form Factor Options
The ION 6100 case has the same length/width dimension as a standard 4”
square electrical box. It is designed to be flush mounted to the electrical panel
or wall.
Option code T1: Inside Mount Style
Option code U1: Outside Mount Style
Split-Core CT Specifications
Rated Inputs
see “Available Options” section
Inputs
Ia, Ib, Ic: split core, low-voltage output CTs
Wire
22 AWG (0.33 mm2) 600 V rated
Wire length
6 ft (180 cm)
Energy accuracy
compliance
ANSI C12.16 Class 1
Installation compliance
Pollution Degree 3,
Overvoltage Category III
CT Dielectric Withstand
2000 VAC rms, 60 Hz for 1 minute
CT voltage output
less than 0.5 V full-scale
Using the Split-Core CTs
The split-core CTs measure the current flow through the conductors and
transform these measured quantities into equivalent low-voltage values
for the ION 6100.
CTs are UL recognized.
The ION 6100 performs calculations based on the assumption that
energy is always delivered, so the energy totals are correct regardless of
CT polarity. However, we recommend the CTs be oriented in a consistent
manner; see “Mounting the Split-Core CTs”.
CTs have an internal burden so shorting blocks are not required.
Voltage Input Specifications
Rated Inputs
see “Available Options” section
Inputs
Va (Red), Vb (Yellow), Vc (Black), Neutral
(White), Ground (Green)
Wire
14 AWG (2.1 mm2) 600 V rated
Wire length
6 ft (180 cm)
Compliance
Installation Category III (Distribution)
Pollution Degree 3
Overload
1500 VAC RMS continuous
Dielectric Withstand
2500 VAC RMS, 60 Hz for 1 second
Meter Label
Location ID contains useful
information for the installer, such
as Floor# and Breaker Panel#.
Installation
The ION 6100 can be mounted against a flat surface, or mounted onto the
side of an electrical panel (inside or outside). In all situations, make sure your
method of installation conforms to the local electrical code.
Environmental Conditions
Mounting location
Indoor
Operating temperature
32ºF to 122ºF (0ºC to 50ºC)
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Relative humidity
5% to 95%, non-condensing
Mounting the ION 6100
The following describe typical installation scenarios for the ION 6100. Note
that the drawings are not to scale.
DANGER
Mounting and installation of the ION 6100 should be performed only by
licensed electricians, and must conform to the local electrical codes.
Disconnect power and lock out all power sources. Do not attempt to connect
voltage input leads when the electrical circuits are live.
Neutral
Ground
(A) is an example of inside panel mounting, (B) is outside panel mounting,
and (C) is outside panel mounting with the wires fed through a conduit.
CAUTION
On smaller panels, installation (A) may invalidate fill allowances. Check with
the local electrical code before performing this installation scenario.
10
Mounting the Split-Core CTs
To maintain measurement accuracy for the split-core CTs:
Use only the CTs supplied with the ION 6100
Do not swap CTs between phases or meters
Do not swap the removable section from one CT to another CT
NOTE
The pluggable wire harness is polarized and color-coded (Red, Yellow, Black)
with the CTs to ensure correct wiring during re-connection.
CAUTION
The removable section fits only one way onto the CT. If it does not fit easily,
make sure that it is not backwards. To prevent damage, do not force the
removable section onto the CT. When opening or closing the CTs, be careful
not to bend the metal strips.
1.
Orient the split-core CTs so the labels are facing towards the load.
2.
Secure the supplied cable ties around the perimeter of each CT to prevent
the CT from opening up.
3.
When the meter is powered up, verify that the Heart Beat / Diagnostic LED
blinks green (see “Verify Meter Operation and Communications” section).
NOTE
The conductors, tubing and PVC jackets on the CT wires are all rated to
600 V, and are UL approved to be field installed in panels up to 600 V.
11
System Wiring Diagrams
Voltage input wires are color-coded to match the corresponding CT labels.
CAUTION
Electrical inspection authorities may require the voltage inputs to be protected
by fuses/circuit breakers. Connecting to a circuit that is protected by a 15 A
breaker is recommended. Make sure your installation complies with local
electrical codes.
Wye and Delta Connection Diagram
Single Phase Connection Diagram
NOTE
In the above wiring diagrams, the specific colors of the leads do not need to
match the phases (i.e. phase A does not need to be RED). However, each
phase must have the same color CT and voltage input lead.
12
Powering the ION 6100
No additional wiring is needed to power up the ION 6100. The ION 6100 is
powered from the electrical system it is monitoring (i.e. voltage inputs Va and
Vc).
Verify Meter Operation and Communications
The LEDs on the ION 6100 provide communications diagnostics for proper
meter operation and communications.
Communications Diagnostics
The Network Link/Traffic LED is a two-color LED that provides information
when the meter is transmitting or receiving information.
LED Activity
Description
Steady Green
(continuously ON)
Radio is properly identified in the wireless
network
Blinking Green
(once per second)
Radio is not identified in the wireless network
Flashing Red
(four times/second)
Radio is transmitting/receiving information (the
Red LED blinks once per packet received)
Meter Diagnostics
The Heart Beat/Diagnostics LED is a two-color LED that indicates whether or
not the meter is functioning properly.
When the meter is initially powered up (from the Va and Vc voltage input
leads), the Heart Beat/Diagnostics LED flashes green (4 times/second). The
meter then performs diagnostic checks, and upon successful completion the
LED blinks green at a slow steady pace (once per second).
LED Activity
Description
Flashing Green
(four times/second)
Startup check
Blinking Green
(once per second)
Startup check passed.
Meter is operating properly.
Voltage and current connections are correct.
Flashing Red
(four times/second)
Meter is unable to measure energy properly due
to incorrect wiring — check the CT and voltage
connections
13
Energy Pulser
The Energy Pulser LED is intended to be used for testing purposes. It blinks
once per accumulated 0.1 kWh.
Meter Troubleshooting
Heart Beat/Diagnostics LED does not blink
Check power connections to meter (voltage input leads Va and Vc).
Check that supply power is turned on for Va and Vc.
Heart Beat/Diagnostics LED flashes red
This typically indicates incorrect voltage and/or current connections:
Check that the color of the voltage input leads matches that of the CTs,
and that the voltage input leads are connected as shown in the “System
Wiring Diagrams”.
Check that the split-core CTs Ia (Red), Ib (Yellow) and Ic (Black) are
connected as shown in the “System Wiring Diagrams”.
Check that all the split-core CTs are oriented properly (sticker faces
towards the load).
Check that there is more than 0.2 A flowing on the wires the CTs are
installed on.
After fixing the incorrect connections, the LED should return to a slow blinking
green.
Heart Beat/Diagnostics LED flashes green
If the LED continuously flashes green (4 times/second) and does not change
from this state, it indicates the meter has encountered an internal error.
Contact Power Measurement for assistance.
14
For further assistance
please contact us at:
Worldwide Headquarters
2195 Keating Cross Road
Saanichton, BC
Canada V8M 2A5
Tel: 1-250-652-7101
Fax: 1-250-652-0411
Email: support@pwrm.com
www.pwrm.com
© 2004 Power Measurement
Printed in Canada
MRP: 70000-0236-00
Revision Date: June 17, 2004

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Modify Date                     : 2004:06:18 09:22:40Z
Create Date                     : 2004:06:18 08:57:15Z
Page Count                      : 16
Creation Date                   : 2004:06:18 08:57:15Z
Mod Date                        : 2004:06:18 09:22:40Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Power Measurement
Metadata Date                   : 2004:06:18 09:22:40Z
Creator                         : Power Measurement
Title                           : ION 6100 Installation Guide
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SDP-ION6100