Powerware 9355 Users Manual 9155/9355FXA
9355 to the manual d14e0dec-cf52-44a9-bcb2-daf175628cd4
2015-02-06
: Powerware Powerware-9355-Users-Manual-520066 powerware-9355-users-manual-520066 powerware pdf
Open the PDF directly: View PDF
.
Page Count: 10
| Download | |
| Open PDF In Browser | View PDF |
Powerware® 9155 Single-phase UPS Powerware 9355 Three-phase UPS Product Focus Powerful. Intelligent. Elegant. Reliability and efficiency have never looked so attractive. 8–15 kVA Product Introduction Product Snapshot Technology: 9155: Split-phase double-conversion online UPS 9355: Three-phase double-conversion online UPS Power Rating: 9155: 8 kVA, 10 kVA, 12 kVA, 15 kVA at 0.9 power factor 9355: 10 kVA and 15 kVA at 0.9 power factor Input Voltage: 9155: 200–240 Vac with Neutral or with optional input isolation transformer 9355: 208V/120V or 220V/127V Output Voltage: 9155: 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement 9355: 208V/120V or 220V/127V 480:120V/208V or 600:120/208 with input isolation transformer (at 60 Hz only) Frequency: 50/60 Hz auto-sensing Dimensions: Two-high configuration: 32.2” H x 12.0” W x 32” D Three-high configuration: 47.8” H x 12.0” W x 33.5” D Configuration: Battery Backup: Small-footprint tower, black 9155: Up to 29 minutes typical, extendable up to four hours 9355: Up to 22 minutes typical, extendable up to three hours See Battery Back-up Times chart Features • Protects connected equipment from all nine of the most common power problems with true online, double-conversion topology • Delivers maximum power density in a compact tower design, only 12” wide and 33” deep, including batteries • Provides more real wattage in less space with a 0.9 power factor—protecting more equipment for every utility dollar, and leaving more room for expansion • Delivers extra capacity or redundancy through patented Powerware Hot Sync® paralleling of multiple modules • Significantly increases battery life through microprocessorcontrolled ABM® technology • Provides 0.99 power factor and generator friendly <5% total harmonic distortion using an active IGBT rectifier to control the input power factor • Ensures data and system integrity with complete power management software for remote monitoring, management, and shutdown • Provides investment protection and peace of mind with an Eaton factory limited warranty, technical support, and optional service plans With advances in miniaturization and processing power, a single rack of equipment demands more power than ever—and more equipment will be served by dual cord power supplies. It’s a challenge to provide power protection for expanding loads in shrinking spaces. Fortunately, technology advancements have also raised the density per square foot of power protection systems. The Powerware 9155 and new Powerware 9355 uninterruptible power systems (UPSs) deliver premium levels of efficiency, reliability and flexibility—all in a sleek tower half the size of most competitor units on the market today. These double-conversion, online UPSs resolve all nine common utility power problems and supply clean, continuous power to all connected equipment. Even when presented with the most severe power problems, power output remains stable. And if the utility power goes out altogether, there is no delay transferring to backup power. These capabilities make the Powerware 9155 and Powerware 9355 ideal for protecting essential data center, communications and electrical engineering infrastructures in corporate, telecom, healthcare, banking, public sector and industrial applications. Powerware 9155/Powerware 9355 shown in perspective. Premium power protection is now easier than ever. With raised-floor real estate at a premium, you will appreciate that these UPSs are only 12” wide and 33” deep, including internal batteries. With such a small footprint, you have more location options, and more space is available for future expansion. Equipment installation is easy, essentially plug-and-play. You can order either UPS with your choice of output receptacles with more than 17 types. To change or move data center equipment, you simply unplug from the old receptacle, plug into a new one, and go. No need for an electrician to run new conduit and wiring. Scalable architecture meets current and future load requirements. Powerware 9155 UPSs are available in four models (8, 10, 12, and 15 kVA). Powerware 9355 UPSs come in 10 and 15 kVA models, so you can choose the configuration that most closely meets your capacity requirements and price point. Powerware 9355 rear view with optional output receptacles And you can scale from there. Using our signature Powerware Hot Sync paralleling technology, up to three (Powerware 9155) or up to four (Powerware 9355) equivalent UPS modules can be paralleled for extra capacity or redundancy. A 15 kVA UPS, for example, can grow to support loads of up to 45 kVA. There’s no dependence on communications wiring among those UPS modules. Battery innovations optimize battery performance and service life. Standard internal batteries provide power until auxiliary power takes over or systems are gracefully shut down. Battery runtime can be extended to hours by adding matching Extended Battery Modules (EBMs). POWERWARE UPS BACKUP TIMES (IN MINUTES) VA 15000 14500 14000 13500 13000 12500 12000 11500 11000 10500 10000 9500 9000 8500 8000 7500 7000 6500 6000 5500 5000 4500 4000 3500 3000 2500 Watt 13500 13050 12600 12150 11700 11250 10800 10350 9900 9450 9000 8550 8100 7650 7200 6750 6300 5850 5400 4950 4500 4050 3600 3150 2700 2250 UPS (1) + Internal EBM 32 Battery 64 4.6 23.0 4.9 24.1 5.2 25.2 5.5 26.4 5.8 27.6 6.1 28.8 6.5 30.2 6.9 31.6 7.3 33.3 7.8 35.1 8.4 37.2 9.1 39.6 9.9 42.3 10.8 45.5 11.9 49.1 13.1 53.2 14.6 58.0 16.3 63.5 18.4 70.0 20.1 77.6 22.4 86.6 25.2 97.4 28.6 110 32.8 127 38.3 148 45.6 176 (2) EBM 64 43.0 45.2 47.3 49.4 51.6 54.0 56.5 59.3 62.4 65.9 69.8 74.2 79.4 85.2 91.9 99.7 109 119 131 145 162 182 207 238 277 329 (3) EBM 64 65.1 68.3 71.5 74.7 78.1 81.6 85.5 89.7 94.4 99.6 106 112 120 129 139 151 164 180 198 220 245 276 313 359 418 - (4) UPS (1) EBM + Internal EBM 64 64 Battery 96 88.6 13.3 43.0 93.0 14.1 45.2 97.4 14.9 47.3 102 15.8 49.4 106 16.7 51.6 111 17.6 54.0 116 18.6 56.5 122 19.2 59.3 129 20.2 62.4 136 21.4 65.9 144 22.6 69.8 153 24.1 74.2 163 25.7 79.4 175 27.6 85.2 189 29.8 91.9 205 32.3 99.7 224 35.2 109 245 38.6 119 270 42.5 131 300 47.2 145 334 52.6 162 376 59.2 182 426 67.1 207 77.0 238 89.7 277 107 329 (2) EBM 96 76.7 80.5 84.2 88.1 92.0 96.2 101 106 111 117 124 132 141 152 164 178 194 212 234 259 289 325 369 423 - (3) EBM 96 113 119 125 130 136 142 149 156 164 174 184 196 209 225 242 263 286 314 346 383 428 - Note: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. Front view Rear view After 15 years of in-service experience, Eaton has real-world proof that ABM technology can significantly increase battery service life. Powerware 9155/Powerware 9355 EBM Powerware 9155 and Powerware 9355 UPSs also use sophisticated technologies that maximize the health and service life of batteries: • ABM technology uses a unique three-stage charging technique that significantly extends battery service life and optimizes recharge time, compared to traditional trickle charging. • Temperature-compensated charging monitors battery temperature and adjusts the charge rate accordingly, which properly charges the battery and greatly extends battery life. • An integrated battery management system tests and monitors battery health and remaining lifetime, and provides advance notification to guide preventive maintenance. Unlike heavy, old-style batteries, Eaton's are easily field-replaceable. One person, working alone, can replace a battery without disrupting data center operations or power to protected equipment. Advanced design delivers unequaled power performance. The innovative design of these UPSs deliver the industry’s best performance combination of efficiency, input current distortion, input power factor, and output power factor. Lower costs, lower temperatures. High efficiency (greater than 90 percent across all load ranges) reduces utility costs, extends battery runtimes, and produces cooler operating conditions. Generator-friendly design. Total input harmonic distortion (THD) remains below five percent without compromising overall efficiency. The result is maximum transfer of power between source and protected load, and exceptional compatibility with auxiliary generators. More real power. On the output side, high power factor enables these UPSs to provide their full power capability to modern IT equipment that may have a wide range of leading and lagging power factors. And, with a 0.99 input power factor, these UPSs avoid the disturbances that energy converters tend to cause. Inside view of Powerware 9155 Parallel Cabinet Powerware Hot Sync Redundant/Capacity Powerware 9155 UPS Parallel Cabinet Load Protect your investment Rest easy, knowing that your UPS is always on the job. While it protects your critical systems, the UPS itself is protected in several ways: Self-diagnosis. The UPS constantly monitors its own operation, such as voltage, temperature or function of internal elements—and sends alarms or takes action if it detects a potential problem. You’ll know your UPS is always performing up to specifications to protect your equipment. Self-correction. If it senses an issue—planned or unplanned—the UPS instantly transfers the power path to a bypass source, with zero interruption in power. When the alarm condition passes, the UPS automatically reverts from bypass to normal operation. Remote monitoring. You can have Eaton specialists securely monitor your Powerware 9155 and Powerware 9355 UPSs around the clock with eNotify service, or you can monitor your own UPSs over your LAN or the Internet. Either way, you’ll always be informed about conditions in your power protection infrastructure. Redundancy. Using Powerware Hot Sync technology, you can configure up to N+3 redundancy. Any module can serve as backup for any other, with no interruption or downtime. For instance, you could perform full maintenance on any UPS without having to remove any loads from conditioned power. Most other paralleling systems on the market use a top-down configuration; if the master fails, the subsidiary units fail. With Eaton’s patented approach, each UPS module is independent yet synchronized with the others. There is no single point of failure. Connectivity options offer maximum flexibility. The standard unit is equipped with an RS-232 serial port to communicate with power management software. You can customize your UPS by adding one or two interface cards for other applications: Monitor the UPS from anywhere. Connect the UPS to the Ethernet network and Internet for secure monitoring and management using a standard Web browser or SNMP. ConnectUPSTM Web/SNMP Card Interwork with your existing Building Management System. A Modbus® Card enables real-time monitoring of UPS systems through a Building Management System or Industrial Automation System. Modbus Card Gather information from relay contact devices. Provide a dry-contact interface between the UPS and any relay-connected device, including the IBM® e-server® iSeries and a variety of industrial applications. Relay Interface Card Have central control and visibility of UPS systems. The Powerware 9155 and Powerware 9355 are shipped with a CD that includes Powerware LanSafeTM power management software and a 30-day trial version of Powerware PowerVision® UPS performance analysis and monitoring software. Using an intuitive, graphical interface and SNMP (Simple Network Management Protocol), administrators can: Independently manage diverse servers. A Multi-Server card enables up to six serially connected devices of mixed operating systems to be independently managed and controlled by a single UPS. Multi-Server Card Powerware Software Suite • Securely monitor UPS and battery performance over your existing Ethernet network and the Internet. • Establish prioritized shutdown of network devices and client/server applications. • Test all networked UPS systems from one node. • Analyze trends and network conditions. • Stay informed of potential power problems by pager and e-mail. Monitor environmental conditions. An optional Environmental Monitoring Probe remotely monitors temperature, humidity, and two user-supplied contacts/sensors, such as smoke and intrusion detection. Environmental Monitoring Probe Gain peace of mind with industry-leading warranty and service plans. all-inclusive packages with unique features, such as advanced remote monitoring with trending, customized capacity planning reports, and power protection audits. Add your choice of guaranteed response times, and you can tailor just the right support package for your needs. We are so confident about the performance and reliability of the Powerware 9155 and Powerware 9355 UPSs and battery systems that we back them with extensive warranty and service plans. Warranty coverage. Gain the peace of mind that comes with factory warranty coverage (parts and labor, UPS and batteries) and rapid response from certified support engineers. Powerware 9155 • 2 year limited factory warranty • 10 year pro-rated warranty • $250,000 load protection guarantee From Eaton—a global leader in power quality solutions. The culmination of 40 years of R&D excellence, the Powerware 9155 and Powerware 9355 UPSs deliver confidence, and ensure that your organization’s critical electronics are protected by the most reliable, efficient, and full-featured protection available. Eaton is a global leader in power quality and management solutions—the #1 manufacturer of UPSs above 5000 VA (Frost & Sullivan: World UPS Markets, 2004). Eaton’s Power Quality Solutions Operation is headquartered in Raleigh, North Carolina, U.S. Powerware 9355 • 1 year Service Protection Plan • 7 x 24 emergency response • On-site start-up support (8 hours/day, 5 days/week) • 3 year battery warranty • 1 year eNotify remote monitoring For more information on the Powerware 9155 and the new Powerware 9355 UPS: www.powerware.com 1-800-356-5794 Service plans. Beyond the warranty period, service plans are available to match any need—from basic UPS and/or battery support to Powerware 9155 and Powerware 9355 at-a-glance MODEL SELECTION TABLE - POWERWARE 9155 UPS (8–15 kVA) Order Number1 K408110000 K408120000 K408130000 K410110000 K410120000 K410130000 K412110000 K412120000 K412130000 K415110000 K415120000 K415130000 Description PW9155 Model 8 - 32 Battery (2-high) PW9155 Model 8 - 64 Battery (3-high) PW9155 Model 8 - 32 Battery with Transformer (3-high) PW9155 Model 10 - 32 Battery (2- high) PW9155 Model 10 - 64 Battery (3- high) PW9155 Model 10 - 32 Battery with Transformer (3-high) PW9155 Model 12 - 32 Battery (2-high) PW9155 Model 12 - 64 Battery (3-high) PW9155 Model 12 - 32 Battery with Transformer (3-high) PW9155 Model 15 - 32 Battery (2- high) PW9155 Model 15 - 64 Battery (3- high) PW9155 Model 15 - 32 Battery with Transformer. (3- high) Power Rating2 (kVA/W) 8kVA / 7.2kW 8kVA / 7.2kW 8kVA / 7.2kW 10kVA / 9kW 10kVA / 9kW 10kVA / 9kW 12kVA / 10.8kW 12kVA / 10.8kW 12kVA / 10.8kW 15kVA / 13.5kW 15kVA / 13.5kW 15kVA / 13.5kW Input & Output Connection4 Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Output Receptacles See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart Dimensions H x W x D (in) 32.2 x 12.0 x 32.0 47.8 x 12.0 x 32.0 47.8 x 12.0 x 32.0 32.2 x 12.0 x 32.0 47.8 x 12.0 x 32.0 47.8 x 12.0 x 32.0 32.2 x 12.0 x 32.0 47.8 x 12.0 x 32.0 47.8 x 12.0 x 32.0 32.2 x 12.0 x 32.0 47.8 x 12.0 x 32.0 47.8 x 12.0 x 32.0 Unit Weight3 (lb) 352 590 558 352 590 558 352 590 558 352 590 558 1. 50/60 Hz auto-sensing. All models can be used for frequency/phase conversion with derated 80% load, please refer to manual for details. 2. Input voltage 200–240V with neutral or with optional input isolation transformer. Output voltages are user-selectable 100/200, 110/220, 120/240 Vac 180° phase displacement, or 120/208, 127/220 Vac 120° phase displacement. 3. Weight is installed weight, add 47lbs (2-high models) or 50lbs (3-high models) to determine shipping weight. 4. An input neutral is required for all configurations unless the input isolation transformer is used. MODEL SELECTION TABLE - POWERWARE 9355 UPS (10–15 kVA) Order Number1 KA1011100000010 KA1012100000010 KA1011200000010 KA1012200000010 KA1011400000010 KA1011600000010 KA1511100000010 KA1512100000010 KA1511200000010 KA1512200000010 KA1511400000010 KA1511600000010 Description PW9355 with 32-Battery (2-high) PW9355 with 64-Battery (3-high) PW9355 with 32-Battery (2-high) PW9355 with 64-Battery (3-high) PW9355 with 32-Battery with Transformer (3-high) PW9355 with 32-Battery with Transformer (3-high) PW9355 with 32-Battery (2-high) PW9355 with 64-Battery (3-high) PW9355 with 32-Battery (2-high) PW9355 with 64-Battery (3-high) PW9355 with 32-Battery with Transformer (3-high) PW9355 with 32-Battery with Transformer (3-high) Power Input & Output Rating2 (kVA/W) Voltages4 10 kVA / 9kW 208/208 10 kVA / 9kW 208/208 10 kVA / 9kW 220/2202 10 kVA / 9kW 220/2202 10 kVA / 9kW 480/208 10 kVA / 9kW 600/208 15 kVA / 13.5kW 208/208 15 kVA / 13.5kW 208/208 15 kVA / 13.5kW 220/2202 15 kVA / 13.5kW 220/2202 15 kVA / 13.5kW 480/208 15 kVA / 13.5kW 600/208 1. 50/60 Hz auto-sensing. 2. 220V units are wye connected 220/127V input and 220/127V output, 3-phase, 4-wire plus ground. 3. Weight is installed weight, add 47 pounds (for 2-high models) or 50 pounds (for 3-high models) to determine shipping weight. 4. An input neutral is required for all configurations unless the input isolation transformer is used. 5. Internal battery, full load. Battery Backup5 8 22 8 22 8 8 4 13 4 13 4 4 Dimensions H x W x D (in) 32.2 x 12.8 x 33.5 47.8 x 12.8 x 33.5 32.2 x 12.8 x 33.5 47.8 x 12.8 x 33.5 47.8 x 12.8 x 33.5 47.8 x 12.8 x 33.5 32.2 x 12.8 x 33.5 47.8 x 12.8 x 33.5 32.2 x 12.8 x 33.5 47.8 x 12.8 x 33.5 47.8 x 12.8 x 33.5 47.8 x 12.8 x 33.5 Unit Weight3 (lb) 373 609 373 609 577 57 373 609 373 609 577 577 ACCESSORIES Order Number Description Dimensions H x W x D (in) Unit Weight (lb) 24.0 x 20.3 x 2.2 - 57.3 - Powerware Hot Sync 124100017-001 103004336 Powerware 9155 Parallel Cabinet Powerware HotSync CAN Bridge Card Notes: Up to three Powerware 9155 UPS and up to four Powerware 9355 UPS (available Fall 2005) UPSs can be paralleled with the Parallel Cabinet. Each Powerware 9155 UPS and Powerware 9355 UPS must have a Powerware Hot Sync CAN Bridge Card installed in the second X-Slot communication bay. Extended Battery Module (EBM) 103004192-5501 103004193-5501 Powerware 9155 and Powerware 9355 EBM 64 (2-high) Powerware 9155 and Powerware 9355 EBM 96 (3-high) 32.2 x 12.0 x 30.2 47.8 x 12.0 x 30.2 480 710 Fits both 2& 3-high models 136 16.5 x 12.0 x 7.0 21.0 x 14.0 x 6.75 15 31 Notes: up to four EBM 64 cabinets or three EBM 96 cabinets can be added to each UPS for extended runtime. Seismic Mounting Kit 103004194-5501 Seismic Kit, Rated Zone 4, UL Tested, Performance rating based on NEBS GR-63-CORE Standard Vibration Test Powerware 9155 Maintenance Bypass Module (MBM) 103004184-5501 BPE14MBB1A UPS-Mounted, Maintenance Bypass Module Wall-mounted, Maintenance Bypass Module Powerware 9155 Parallel System Start Up OSTUP9155P15KCX OSTUP9155P10KCX 103004626 103004627 Powerware 9155 8-10 kVA 2 or 3 Unit Parallel Powerware 9155 12-15 kVA 2 or 3 Unit Parallel Powerware 9155 Parallel System 2 unit upgrade kit (includes Can Bridge Cards, Procedures, and Parallel User's Guide) Powerware 9155 Parallel System 3 unit upgrade kit (includes Can Bridge Cards, Procedures, and Parallel User's Guide) Connectivity Options 103002974-5501 05146288-5501 103002510-5501 05146508-5501 05146447-5501 1018460 103003055 103003637-5501 ConnectUPS-X Web/SNMP/xHub Card ConnectUPS-MX SNMP/Modem Card (9155 only) Modbus Card USB Card Multi-Server Card (9155 only) Relay Interface Card (AS/400 Compatible) Industrial Relay Card Environmental Probe (requires ConnectUPS Web/SNMP card) Spare Parts 106711155 Powerware 9155 Spare Parts Kit "A" 106711169 Powerware 9355 Spare Parts Kit "A" Upgrades 103004195 103004196 103004657 Powerware 9155 8 kVA to Powerware 9155 10 kVA Powerware 9155 12 kVA to Powerware 9155 15 kVA Powerware 9355 10 kVA to Powerware 9355 15 kVA Power Distribution Module (PDM) with Mechanical Bypass Switch Optional Receptacle Panels (1) L15-30R (1) L21-20R (1) L21-30R (2) 5-15R (2) 5-20R (2) 6-15R (2) 6-20R (2) L5-15R (1) L5-20R1 (1) L5-30R1 (2) L6-15R (1) L6-20R1 (1) L6-30R1 (1) L14-20R1 (1) L14-30R1 (2) IEC 320 C13 (120V) (2) IEC 320 C19 (120V) Blank panel Breaker 30A 20A 30A 15A 20A 15A 20A 15A 20A 30A 15A 20A 30A 20A 30A 20A 20A Voltage 208V 208/120V 208/120V 120V 120V 208V 208V 120V 120V 120V 208V 208V 208V 120/208V 120/208V 120V 120V Phase 3 3 3 1 1 2 2 1 1 1 2 2 2 2 2 1 1 Note: Maximum of eight panels per PDM (Powerware 9155). Maximum of four panels per PDM (Powerware 9355). 1. The combined quantities of single-locking receptacle panels must not exceed five per PDM. POWERWARE 9155 UPS WARRANTY AND SERVICE CHART POWERWARE 9355 UPS SERVICE CHART Start-up Warranty Upgrades Service Protection Plan Upgrades Warranty PowerTrustTM Service Plan Upgrade upgrade for first year of service only Start-up Services Upgrade (5x8 to 7x24) Recertification/Restart Coverage or Response Time 4 hr 2 hr 8 hr 4 hr 2 hr 7x24 7x24 Item # SP41A SP21A PP81B PP41B PP21B SU97A RC07N Unit + Internal Service Plan Contracts Battery EBM 64 EBM 96 PowerTrust ULTRATM Service Plan (Premium) PowerTrust ULTRATM Service Plan (7x24) parts and labor coverage, annual 7x24 UPS preventative maintenance, battery parts & labor coverage, eNotify remote UPS and battery monitoring - must be connected; 30% discount on upgrades and T&M; includes 1 complete battery update every 6 year period): 8 hr Response PU81N PU81N-BA6 PU81N-BA9 4 hr Response PU81N PU81N-BA6 PU81N-BA9 2 hr Response PU21N PU21N-BA6 PU21N-BA9 PowerTrustTM Service Plan (Premium) PowerTrustTM Service Plan (7x24 parts and labor coverage, annual 5x8 UPS and battery preventative maintenance, eNotify remote UPS and battery monitoring; 15% discount on upgrades): 8 hr Response PT82N 4 hr Response PT42N 2 hr Response PT22N PowerTrustTM VALUE Service Plan PowerTrustTM VALUE Service Plan (5x8 parts and labor coverage, next business day response, annual 5x8 UPS preventative maintenance, eNotify remote UPS and battery monitoring): PVN3N 3 Year Battery Labor Coverage Adds labor and freight to 3YR battery parts warranty: BL87N Preventative Battery Preventive Maintenance Priced per VRLA cabinet: 5x8 coverage 7x24 coverage UPS Preventive Maintenance 5x8 coverage 7x24 coverage Unit + Internal Battery 0006N-BIN 0005-BIN 0006N 0005N Service Plan Features Service plan terms available 90 days on-site labor (5x8); two years parts coverage On-site startup of UPS and batteries, 7/24 On-site corrective maintenance, 7x24 Full coverage of UPS and internal battery module 7x24 technical telephone support Service priority Full coverage of extended battery modules One 7x24 annual preventive maintenance inspection 0006N-BAG 0005N-BAT EBM 96 0006N-BAG 0005N-BAG On-Site Gold Plan On-Site Gold Plan Plus 2 Yr 2, 3, 5 Yr 2, 3, 5 Yr Service included Optional service POWERWARE 9155 UPS (ON-SITE SERVICE IS 24 HOURS A DAY, 7 DAYS A WEEK) ON-SITE GOLD Part Number Powerware 9155 UPS (8–10 kVA) 2 Yr 2OSGX915510KVCX 3 Yr 3OSGX915510KVCX 5 Yr 5OSGX915510KVCX Powerware 9155 UPS (12–15 kVA) 2 Yr 2OSGX915515KVCX 3 Yr 3OSGX915515KVCX 5 Yr EBM 64 Limited Factory Warranty 5OSGX915515KVCX ON-SITE GOLD PLUS Part Number 2OSGP915510KVCX 3OSGP915510KVCX 5OSGP915510KVCX 2OSGP915515KVCX 3OSGP915515KVCX 5OSGP915515KVCX POWERWARE 9155 UPS EXTENDED BATTERY MODULES (ON-SITE SERVICE IS 24 HOURS A DAY, 7 DAYS A WEEK) Powerware 9155 EBM 64 2 Yr 3 Yr 5 Yr Powerware 9155 EBM 96 2 Yr 3 Yr 5 Yr ON-SITE GOLD Part Number ON-SITE GOLD PLUS Part Number 2OSGX9155EB64CX 3OSGX9155EB64CX 5OSGX9155EB64CX 2OSGP9155EB64CX 3OSGP9155EB64CX 5OSGP9155EB64CX 2OSGX9155EB96CX 3OSGX9155EB96CX 5OSGX9155EB96CX 2OSGP9155EB96CX 3OSGP9155EB96CX 5OSGP9155EB96CX POWERWARE 9155 UPS PARALLEL SYSTEM (ON-SITE SERVICE IS 24 HOURS A DAY, 7 DAYS A WEEK) ON-SITE GOLD Part Number Powerware 9155 UPS (8-10 kVA) 2 Unit Parallel System 2 Yr 2OSGX915510P2CX 3 Yr 3OSGX915510P2CX 5 Yr 5OSGX915510P2CX Powerware 9155 UPS (8-10 kVA) 3 Unit Parallel System 2 Yr 2OSGX915510P3CX 3 Yr 3OSGX915510P3CX 5 Yr 5OSGX915510P3CX Powerware 9155 UPS (12-15 kVA) 2 Unit Parallel System 2 Yr 2OSGX915515P2CX 3 Yr 3OSGX915515P2CX 5 Yr 5OSGX915515P2CX Powerware 9155 UPS (12-15 kVA) 3 Unit Parallel System 2 Yr 2OSGX915515P3CX 3 Yr 3OSGX915515P3CX 5 Yr 5OSGX915515P3CX ON-SITE GOLD PLUS Part Number 2OSGP915510P2CX 3OSGP915510P2CX 5OSGP915510P2CX 2OSGP915515P3CX 3OSGP915515P3CX 5OSGP915515P3CX 2OSGP915515P2CX 3OSGP915515P2CX 5OSGP915515P2CX 2OSGP915515P3CX 3OSGP915515P3CX 5OSGP915515P3CX Four button graphical LCD with backlight X-Slot Communication Bay #1 Fans Signal Input 1 Signal Input 2 REPO (normally open) REPO (normally closed) X-Slot Communication Bay #2 DB-9 Communication Port Relay Contact Internal batteries on slide out trays (field-replaceable) Front view of 3-high module with cover off TECHNICAL SPECIFICATIONS1 Power Ratings (kVA/Watts) 9155: 8, 10, 12 and 15 kVA at 0.9 power factor 9355: 10 and 15 kVA at 0.9 power factor Topology True double-conversion online UPS Electrical Input Nominal Input Voltage 9155: 200V-240V with neutral or with optional input transformer 9355: 208V/120V or 220V/127V three phase Input Voltage Range -15%, +10% from nominal at 100% load without depleting battery Operating Frequency 50/60 Hz (45 to 65 Hz) Input Power Factor P.F >0.99 typical, >0.96 frequency converter Input Current Distortion 5% THD Electrical Output Nominal Output Voltage 9155: 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement 9355: 208/120, 220/127 Vac Output Voltage Regulation ±1% Static; ±5% dynamic at 100% resistive load change, <1 ms response time Efficiency 9155: 90% typical 9355: 91% typical Battery Battery Type 9Ah, sealed, lead-acid, maintenance-free Battery Runtime See Battery Runtime Chart Battery Replacement Field-replaceable Charger Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current) Start-On-Battery Allows start of UPS without utility input General Diagnostics Full system self-test at startup UPS Bypass Automatic on overload or UPS failure Parallel for Redundancy Yes, using Powerware Hot Sync technology and Capacity Dimensions and Weights See Model Selection Table Overload 150% for 5 sec / 125% for 1 min (online), (Normal Operation) 110% for 10 min Communications LCD Display Graphical LCD with blue backlight LEDs (4) LEDs for notice and alarm Audible Alarms Yes Communication Ports (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input Communication Slot (2) X-Slot communication bays Power Management Bundled Software Suite CD Software Environmental Operating Temperature 10ºC to +40ºC, +45ºC with 7.5% derating; Batteries recommended max. +25ºC Storage Temperature -15ºC to +25ºC Relative Humidity 0–95%, non condensing Audible Noise 9155: Audible Noise: < 53 dBA at 1 meter (noise less room) typical 9355: Audible Noise: < 56 dBA at 1 meter (noise less room) typical Altitude < 1000m at +40°C, < 3000m at +25°C Certifications Safety Certifications 9155: NOM-0190SCFI-1993, UL 1778, CSA C22.2, No. 107.3; EN 5502 Class A (CISPR22 Class A) and IEC 60950; IEC 62040-1-1 9355: IEC 62040-1-1, IEC 60950, EN 62040-1-1, UL 1778 EMC Compliance 9155: IEC 62040-2, FCC Part 15, ICES-003, VCCI 9355: EN 50091-2 Class A Quality ISO 9001: 2000 and ISO 14001:1996 Markings 9155: UL, cUL, CSA, CE and NOM-NYCE 9355: UL, cUL 1. Due to continuous product improvements, program specifications are subject to change without notice. UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 or 919.872.3020 www.powerware.com CANADA Ontario: 416.798.0112 LATIN AMERICA Argentina: 54.11.4343.6323 Brazil: 55.11.3616.8500 México: 52.55.5488.5252 EUROPE/MIDDLE EAST/AFRICA Denmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.7841.666.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700 ASIA PACIFIC Australia/NZ: 61.2.9878.5000 China: 86.21.6361.5599 HK/Korea/Taiwan: 852.2745.6682 India: 91.11.2649.9414 to 18 Singapore/SEA: 65.6829.8888 Powerware, ABM, ConnectUPS, LanSafe, PowerVision, Powerware Hot Sync, and X-Slot are trade names, trademarks, and/or service marks of Eaton Power Quality Corporation or its subsidiaries and affiliates. All other trademarks are property of their respective owners. © 2005 Eaton Corporation All Rights Reserved Printed in USA 9155/9355FXA July 2005
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : 3.1-701 About : uuid:491bb6b0-f54e-11d9-bab5-001124301b42 Create Date : 2005:07:07 00:57:50Z Metadata Date : 2005:07:15 12:34:39-04:00 Modify Date : 2005:07:15 12:34:39-04:00 Creator Tool : Adobe InDesign CS (3.0.1) Rendition Class : proof:pdf Document ID : adobe:docid:indd:78bff59d-f014-11d9-9bfb-c4a0d0443975 Instance ID : uuid:56be07e6-f54e-11d9-a434-001124301b42 Derived From Instance ID : a9dcfce9-eff5-11d9-917f-ad45fe01ed2e Derived From Document ID : adobe:docid:indd:e3e5b1e9-ebc8-11d9-96bf-e96acd8a4401 Manifest Link Form : ReferenceStream, DirectStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Reference Instance ID : uuid:7a444a0e-ebcc-11d9-b37c-e8cfff9e24bf, uuid:e80322b8-3576-11d9-9765-ba17319b9939, uuid:777656c9-e56c-11d9-895d-cf5af4c24ede, uuid:a00711f9-e56c-11d9-895d-cf5af4c24ede, uuid:9c5bcc81-651f-11d8-977e-c4944282c4c0, uuid:fa643ca4-f594-11d9-abc6-d0b5e28748a5, uuid:7d1dd686-eb20-11d9-b659-bfa666a990e6, uuid:06fdd640-2a67-11d9-8364-f1788d1fd1e5, uuid:777656c4-e56c-11d9-895d-cf5af4c24ede, uuid:7d728d5a-ebb8-11d9-b37c-e8cfff9e24bf, uuid:01674b92-ebbf-11d9-b37c-e8cfff9e24bf Manifest Reference Document ID : adobe:docid:photoshop:d7133d71-ea40-11d9-b4cd-c0f44e645965, adobe:docid:photoshop:42e12cc0-356b-11d9-9765-ba17319b9939, adobe:docid:photoshop:37ba4cea-e0e5-11d9-a0c3-84f9385aa699, adobe:docid:photoshop:37ba4cf0-e0e5-11d9-a0c3-84f9385aa699, adobe:docid:photoshop:93b2c174-5fa4-11d8-8fb1-cbc0816f9966, adobe:docid:photoshop:f91a0cf7-613a-11d8-9101-a26e92f81496, adobe:docid:photoshop:1ea235ed-eb07-11d9-b659-bfa666a990e6, adobe:docid:photoshop:06fdd63f-2a67-11d9-8364-f1788d1fd1e5, adobe:docid:photoshop:7bbcbdf3-e0e7-11d9-a0c3-84f9385aa699, adobe:docid:photoshop:7bbcbdfb-e0e7-11d9-a0c3-84f9385aa699, adobe:docid:photoshop:d3600ed8-ebb9-11d9-b37c-e8cfff9e24bf Format : application/pdf Title : 9155/9355FXA.indd Producer : Adobe PDF Library 6.0 Trapped : False Has XFA : No Page Count : 10 Creator : Adobe InDesign CS (3.0.1)EXIF Metadata provided by EXIF.tools