OPERATING INSTRUCTIONS
SPA9325-30
Note: These operating instructions describe the procedure for turning on and off the amplifier
output power using signal generators. This amplifier will be used with transmitters which have been
or will be certified separately. The specific transmitter instruction book should be consulted for the
correct method to use this amplifier with transmitters.
1.
The input voltage range, applied to pin A1 of the DC input connector, should be between –36VDC and
–57 VDC. Pin A2 and A3 of the connector should be grounded.
2.
Pin 5 of the Data I/O connector should be grounded to enable operation of the amplifier without the
data interface. Pins 1, 2, 11, and 12 on the Data I/O connector are connected to ground. Operation
with the Data I/O interface can only be performed using the transmitter software. See the transmitter
manual for instructions.
3.
Connect the RF signal generator to the RF input port.
4.
Connect the RF output port to the measurement equipment. Make sure the measurement equipment is
capable of handling 30 watts, or use a power attenuator or directional coupler to attenuate the signal to
a level the equipment can handle.
5.
To turn on the amplifier, first apply the DC voltage with the specified range (-48 VDC nominal).
6.
Apply RF power from the signal generator. Adjust the RF input power until the desired RF output
power is achieved. The amplifier’s maximum RF output power rating is 30 watts (+44.8 dBm)
7.
The gain may change up to 0.5 dB as the amplifier temperature stabilizes after turn-on. Let the
amplifier warm up for 10-30 minutes, then re-adjust the power to compensate for the gain change.
8.
The amplifier is now operational.
SPECIFICATIONS
Parameter
Specification
Operating Frequency
Rated Output Power
Gain at Full Power
Input Voltage Range
Maximum DC Power Consumption
Channeling
Modes of Transmission
Type of Modulation
1930 to 1990 MHz
+44.8 dBm (30 Watts)
48 +/- 1 dB
-36 to –57 VDC
220 Watts
Controlled by transmitter
GSM (Gaussian Minimum Shift Keying)
Not applicable (performed by transmitter)
Occupied Bandwidth and Emissions Designators
Emissions Type
Amplitude
GSM (300KGXW)
-30 dBc
-33 dBc
-60 dBc
-70 dBc
-73 dBc
-75 dBc
-80 dBc
Frequency Removed from Carrier
200 kHz
250 kHz
400 kHz
600 kHz
1200 kHz
1800 kHz
6000 kHz


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2001:05:08 10:11:00
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:05:08 10:11:01-04:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E675JS0041

Navigation menu