Powerwave Technologies 5JS0046 Hurricane, Model NTGY81AA User Manual 5

Powerwave Technologies Inc Hurricane, Model NTGY81AA 5

sect 5

Download: Powerwave Technologies 5JS0046 Hurricane, Model NTGY81AA User Manual 5
Mirror Download [FCC.gov]Powerwave Technologies 5JS0046 Hurricane, Model NTGY81AA User Manual 5
Document ID125998
Application IDEwhlOuW6uu/wzgZVmlCEkQ==
Document Descriptionsect 5
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize2.58kB (32262 bits)
Date Submitted2000-11-20 00:00:00
Date Available2000-11-21 00:00:00
Creation Date2000-10-30 09:31:35
Producing SoftwareAcrobat PDFWriter 4.0 for Windows
Document Lastmod0000-00-00 00:00:00
Document Title5.PDF
Document CreatorMicrosoft Word
Document Author: Judy

Section
MAINTENANCE
5-1. INTRODUCTION
This section contains periodic maintenance and performance test procedures for the multichannel
power amplifier. It also contains a list of test equipment required to perform the identified tasks.
NOTE
Check your sales order and equipment warranty
before attempting to service or repair the unit. Do not
break the seals on equipment under warranty or the
warranty will be null and void.
Do not return
equipment for warranty or repair service until proper
shipping instructions are received from the factory.
5-2. PERIODIC MAINTENANCE
Periodic maintenance requirements are listed in Table 5-1. Table 5-1 also lists the intervals at
which the tasks should be performed.
Table 5-1. Periodic Maintenance
TASK
Inspection
Cables and Connectors
INTERVAL
ACTION
12 Months
Performance Tests
12 Months
Inspect signal and power cables for frayed
insulation. Check RF connectors to be
sure that they are tight.
Perform annual test per paragraph 5-5.
5-3. TEST EQUIPMENT REQUIRED FOR TEST
Test equipment required to test the amplifier is listed in Table 5-2. Equivalent test equipment may
be substituted for any item, keeping in mind that a thermistor type power meter is required.
NOTE
All RF test equipment must be calibrated to 0.05
dB resolution. Any deviation from the nominal
attenuation must be accounted for and factored
into all output readings.
044-05079 Rev. A
5-1
Table 5-2. Test Equipment Required
MENCLATURE
Signal Generator
30 dB Attenuator, 250 Watt
Spectrum Analyzer
Coax Directional Coupler
Power Meter / Sensor
Network Analyzer
Current Probe
Source Diskette
Driver PA (1930-1990 MHz)
MANUFACTURER
Agilent (H.P.)
Tenuline
H.P.
H.P.
H.P.
H.P.
MODEL
ESG4433B
8562E
778D
437B / 8481A
8753D
Powerwave
12 dB gain, P1dB = 29 dBm (min)
5-4. PERFORMANCE TEST
Performance testing should be conducted every 12 months to ensure that the amplifier system
meets the operational specifications listed in table 5-3. Also verify system performance after any
amplifier module is replaced in the field. The test equipment required to perform the testing is listed
in table 5-2, and the test setup is shown in figure 5-1.
5-4.1. AMPLIFIER PERFORMANCE TEST.
To perform the test, proceed as follows:
1.
Connect test equipment as shown in figure 5-1.
NOTE
Do not apply any RF signals at this time.
AMPLIFIER SPURIOUS EMISSIONS TEST:
2.
Load the MFRM waveform on the ESG (signal generator). Apply this signal through a driver
amplifier to the MCPA so that the RF signal going into the MCPA is approximately 0 dBm
(adjust the input RF signal level to get 47 dBm output power). Measure spurious
emissions. Verify that it is within specification.
GAIN TEST:
3.
Set input power level to power amplifier at 0 dBm (1932, 1960, and 1987 MHz).
4.
Measure the output power in dBm.
5.
Subtract input power (in dBm) from output power (in dBm) to get gain.
6.
Check the amplifier gain across the band from 1930 MHz to 1990 MHz. Gain should be 47
±2 dB. Record test data in table 5-3.
INPUT RETURN LOSS TEST:
7.
Read and record the S11 return loss measurement on network analyzer. Record test data in
table 5-3.
044-05079 Rev. A
5-2
Figure 5-1. NTGY81AA Amplifier Test Setup Diagram
044-05079 Rev. A
5-3
Table 5-3. Multichannel Power Amplifier NTGY81AA Test Data Sheet
Tested By: ___________________
Serial No: ________________
Pass/Fail: ____________________
Date: ____________________
50W MCPA Test
Test Conditions: Load and source impedance: 50 ohms, VSWR < 1.2:1
Supply voltage: +26 Vdc ± 0.4 Vdc (unless otherwise noted).
Network Analyzer Span: 60 MHz
Marker #1 = 1930 MHz, #2 = 1960 MHz, #3 = 1990 MHz
TEST
CONDITION
1.00
1.01
1.02
NETWORK ANALYZER
Gain
Gain Flatness
1.03
1.04
2.00
Input Return Loss, worst case In band
Output Return Loss, worst case in band
CDMA TESTS (Spurious Emissions)
3 TONE: W-CDMA @ 50W out
RBW= 3KHz; VBW=10KHz
2.01
? @ +2.25 Mhz
2.02
? @ –2.25 Mhz
2.03
2nd Harmonic
MIN
45.0 dB
0 dB
MAX
FREQUENCY (MHz)
1930
1960
1990
3860
3920
3980
1925
1945
1965
49.0 dB
0.4 dB/
1.25 MHz
-10 dB
-15 dB
-16 dBm/
1 MHz
-16 dBm/
1 MHz
-16 dBm/
1 MHz
2.04
Pilot
16 dBm/
1 MHz
2.05
Current @ 50 W out
044-05079 Rev. A
19 A
5-4
5-5. FIELD REPLACEMENT OF THE MODULE
The NTGY81AA multichannel power amplifier module can be replaced in the field on site by a
qualified technician with experience maintaining RF power amplifiers and similar equipment.
To replace a power amplifier module, proceed as follows:
1.
Turn off 26 Vdc power to that specific module.
2.
Disconnect the two RF cables and connectors P1 through P5.
3.
Remove 13 screws that secure amplifier module to heat sink.
4.
Carefully remove amplifier module from heat sink.
5.
Add Thermstrate thermal interface pad to surface of replacement amplifier
which mates with heatsink.
6.
044-05079 Rev. A
Install replacement in reverse order of steps 1 through 4 above.
5-5

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 5
Creator                         : Microsoft Word
Create Date                     : 2000:10:30 09:31:35
Title                           : 5.PDF
Author                          : Judy
Producer                        : Acrobat PDFWriter 4.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E675JS0046

Navigation menu