Powerwave Technologies OFR400 LINKnet OFR400 RF Repeater Module User Manual users manual part 2

Powerwave Technologies Inc. LINKnet OFR400 RF Repeater Module users manual part 2

Contents

users manual part 2

         LINKLINKLINKLINKnetnetnetnet™™™™    OFR400 RF MODULESOFR400 RF MODULESOFR400 RF MODULESOFR400 RF MODULES    USER MANUALUSER MANUALUSER MANUALUSER MANUAL    INSTALLATION, OPERATION INSTALLATION, OPERATION INSTALLATION, OPERATION INSTALLATION, OPERATION AND MAINTENANCEAND MAINTENANCEAND MAINTENANCEAND MAINTENANCE       KAVAL TELECOM INC. 60 Gough Road Markham, Ontario L3R 8X7 Telephone: (888) 86-KAVAL Web:   www.kaval.com E-mail:  info@kaval.com  Document #DCM000000019, Rev.0
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  2000-04-11 13:13:34  Revision Date: 4/11/00:  ii   PPPPPPPPRRRRRRRROOOOOOOOPPPPPPPPRRRRRRRRIIIIIIIIEEEEEEEETTTTTTTTAAAAAAAARRRRRRRRYYYYYYYY        SSSSSSSSTTTTTTTTAAAAAAAATTTTTTTTEEEEEEEEMMMMMMMMEEEEEEEENNNNNNNNTTTTTTTT         © 2000 KAVAL TELECOM INC. All rights reserved. No part of this publication, or any software included with it may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, including photocopying, electronic, mechanical, recording or otherwise, without the prior written permission of the copyright holder. This document contains proprietary information of KAVAL TELECOM INC. The contents are confidential and any disclosure to persons other than the officers, employees, agents or subcontractors of the owner or licensee of this document, without the prior written consent of KAVAL TELECOM INC., is strictly prohibited.  KAVAL TELECOM INC. provides this document as is, without any warranty of any kind either expressed or implied including, but not limited to, the implied warranties of merchantability and fitness of a particular purpose. KAVAL TELECOM INC. may make changes or improvements in the equipment, software, or specifications described in this document at any time and without notice. These changes will be incorporated in new releases of this document.  This document may contain technical inaccuracies or typographical errors. KAVAL TELECOM INC. waives responsibility for any labour, materials, or costs incurred by any person or party as a result of using this document. KAVAL TELECOM INC., and any of its affiliates shall not be liable for any damages (including, but not limited to, consequential, indirect or incidental, special damages or loss of profits or date) even if they were foreseeable and KAVAL TELECOM INC. has been informed of their potential occurrence, arising out of or in connection with this document or its use.
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  2000-04-11 13:13:34  Revision Date: 4/11/00:  iii    RRRRRRRREEEEEEEEVVVVVVVVIIIIIIIISSSSSSSSIIIIIIIIOOOOOOOONNNNNNNN        RRRRRRRREEEEEEEECCCCCCCCOOOOOOOORRRRRRRRDDDDDDDD        Rev. № Page № Description of Revision  Date 0 All Original Release  Apr.6,2000                                         TTTTTTTTRRRRRRRRAAAAAAAADDDDDDDDEEEEEEEE        MMMMMMMMAAAAAAAARRRRRRRRKKKKKKKK        NNNNNNNNOOOOOOOOTTTTTTTTIIIIIIIICCCCCCCCEEEEEEEE        This manual makes reference to trademarks that are the property of other companies.  References are used only to refer to the products or services of the trademark owners.  LINKnet™ is a trademark of KAVAL TELECOM INC.
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  2000-04-11 13:13:34  Revision Date: 4/11/00:  iv   TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTS    1. OFR400 MODULES.................................. 4 OVERVIEW ............................................................. 4 Theory Of Operation......................................... 4 MODELS................................................................. 4 BLOCK DIAGRAM..................................................... 5 OFR400 RF Module ......................................... 5 MODULE SPECIFICATIONS ....................................... 6 OPERATION............................................................ 7 Software Set-up ................................................ 7 Power On Self Test (POST) ............................. 8 Normal Operation ............................................. 9 OFR Drawing (Sides and Top) ....................... 10 ANTENNA INSTALLATION........................................ 11
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00    4    Theory Of Operation An OFR, or On Frequency Repeater, is a radio repeater that simultaneously receives and transmits a single narrow band radio channel on exactly the same frequency.  The OFR accomplishes its repeater function without store and forward circuitry, or expensive conventional simulcasting techniques. The fact that the same frequency is retransmitted by an OFR means that additional frequency allocations are not required in situations where an existing radio coverage pattern needs to be extended. The most common OFR applications are the extension of above ground signals into buildings, tunnels, vehicles or the extension of radio coverage patterns into outdoor shaded areas such as deep valleys. From an applications standpoint, an OFR is very similar to a regular two-way radio repeater. On Frequency Radio Repeaters can be combined using regular two-way radio multicoupling or duplexing equipment and have input and output signal characteristics to those of regular transmitters and receivers. The one special consideration in OFR systems is that of input to output antenna isolation. This must be carefully engineered for each installation. Standard On Frequency Radio Repeaters are designed for indoor use only and are intended for mounting in a standard EIA 19 inch rack. Modular design of OFR circuitry allows for easy servicing, stocking of spares, adaptability and upgrade ability. OFR400 MODULE FAMILY MODEL  TYPE  FREQUENCY OFR400-A1  25 KHz Channels  403-430 MHz (FM) OFR400-A2  12.5 KHz Channels  403-430 MHz (FM) OFR400-B1  25 KHz Channels  430-450 MHz (FM) OFR400-B2  12.5 KHz Channels  430-450 MHz (FM) OFR400-C1  25 KHz Channels  440-470 MHz (FM) OFR400-C2  12.5 KHz Channels  440-470 MHz (FM) OFR400-D1  25 KHz Channels  470-490 MHz (FM) OFR400-D2  12.5 KHz Channels  470-490 MHz (FM) OFR400-E1  25 KHz Channels  490-512 MHz (FM) OFR400-E2  12.5 KHz Channels  490-512 MHz (FM) 1. OFR400 MODULES Overview Models
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00    5    OFR400 RF Module  Block diagram Transmit  BoardUMC Controller BoardReceive BoardIF BoardRF Input403- 512 M H zRF Output403- 512 M H zMicro-Controllerwith lines toall  Boar dsBlind-Mateto SMA RFConnectorBlind-Mateto SMA RFConnectorPower &Control toBackplaneGain ControlComm unicationInterfacesGainControl TestOscillatorLow NoisePre-Amplifier BufferAmplifiers2'nd LocalOscillatorFirst LocalOscillatorBuffers, Filters, andLinear Power AmplifierPowerCircuitsFirst LocalOscillator2' nd IFCrystalFilterFirst IFFilterFirst IFFilter2' nd IFCrystalFilter2'nd LocalOscillator
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00    6    SPECIFICATION   Frequency Bands  403-512 MHz in 5 Bands Channel Spacing  25 or 12.5 KHz Modulation Types  Narrowband FM RF Frequency Stability  Tracks Input Signal Exactly Adjacent Channel Selectivity  60 dB Minimum Max. RF Output Power  37 dBm RF Output Power Range  Power can be reduced 20 dB in 1 dB Steps (AGC Controlled) RF Output Power Variation vs. Input (over -90 to -30 dBm)  0 TO +1 dB Input Dynamic Range  -110 to -30 dBm Input Sensitivity Adjust Range  -110 to -30 dBm Input Hysteresis  1 to 10 dB Transmit Duty Cycle  Continuous Transmit Spurious Output  -13 dBm max Receive Conducted Spurious Output  -57 dBm Max Maximum Gain  140 dB Audio Distortion & Noise (Narrowband FM)  <3% Increase Transmit Key-Up Time  < 2 mS Transmit Key-Down Time  < 1 mS Group Delay  <120 uS Input / Output Connectors  SMA Connectors on back of Card-Cage Input / Output Impedance  50 Ohms Module Power Supply Requirements  +12V & +28V from Card-Cage Power Supply Module Power Consumption  45 W Maximum Connections to Card-cage  Edge Connector for Power and Data and Two Blind-Mate RF Connectors Front Panel Indicators  Operating, Stand by, Fault, Program Mode, Receive, Transmit Module Interconnections (via Card-Cage) DB-15 Connector on back of Card-Cage provides per-Module Fault Relay, Interconnect to other Modules, & RS-232 connection to a PC. Configuration Options RF Modules may be configured either via the optional Controller Module, or via a PC and an RS-232 Connection via the Card-Cage. Module Specifications
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00    7   SPECIFICATION   Size  9.11” High, 2.00” Wide, 14.00” Deep Weight  10 lbs, 4.5 kg Max      Software Set-up The OFR400 module is shipped pre-configured with the following factory set options: OPTION  RANGE OF VALUES  DEFAULT VALUE Frequency  403 – 512 MHz (As per Model)  Order Specific Receive Threshold –110 to -50 dB  -89 dB Receive Hysteresis  1 to 10 dB  2.5 dB Hang Time  0.0 to 5.0 Seconds  2.0 Seconds Time Out  0 to 600 Seconds Or none  300 Seconds Module Enabled  On / Off  On Transmit Power Level  20 to 37 dBm  Order Specific   In line with the versatility of the LINKnetTM Platform, it is possible to re-configure the OFR400 module in the field.  For further information on the modification software and the PC adapter, contact KAVAL TELECOM INC. by E-mail: info@kaval.com Default values may be changed when an order is placed.  Check your order confirmation (shipped with modules) for customized values.Operation
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00    8     Power On Self Test (POST) Each system module automatically performs a self-diagnostics when inserted into the system Card-cage.  These tests determine that the unit is a) correctly installed in the Card-cage and b) not damaged in transit.  •  All six of the LED’s on the front panel will flash 3 times •   If the LED’s do NOT flash three times, then remove the module, check the power source, and re-insert the module, (See Installation Instructions). •  If the card is “OK” the LED’s will continue normally. (See Normal Operation) •  If there is a fault, then the Red Fault LED will remain on.  If this occurs, contact your KAVAL TELECOM INC. Service Representative, (See Warranty / RMA Procedures).  The Power On Self Test is Not an RF test, it only verifies that there is power to the unit and that the logical circuitry is functioning.
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00    9   Normal Operation  The OFR400 Module has six LED’s on the faceplate: 1.  OPERATING - Under normal operating conditions, this LED will flash GREEN when RF Data is present. 2.  STAND BY – Under the control of the Controller Module, the OFR400 Module has the ability to act as a duplex transmitter, sitting perpetually in Stand by Mode waiting for the primary transmitter to fail. This LED should be constant Amber. If a Fault should occur with the primary module, the “Stand by” unit will immediately become the primary unit, at which time the Stand by LED will be turned off and the LED’s will show an operating Module. 3.  Transmit – This Green LED will be on when a signal is being transmitted 4.  Receive – This Green LED will be on when a signal is being received 5.  Program – This LED will be constant Amber when the unit is being re-programmed by the Controller Module. This will signify that the unit is powered on but unavailable for use. 6.  FAULT – Red LED, If the internal diagnostics for the module detect a problem, then this LED will remain on
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00   10   OFR Drawing (Sides and Top) OFR400 Module
LINKnet™  OFR400 RF MODULES  !  USER MANUAL  DCM000000019   Printed:  00.04.11,13:13  Revision Date:4/11/00   11    •  All Antenna Installation is to be performed by Qualified Technical Personnel only.  •  Antenna Installation Instructions and locations below are for the purpose of satisfying FCC RF Exposure Compliance requirements.  •  The Roof Top Antenna for linking to the Donor Site is a directional (high gain) Antenna fixed-mounted physically on the side or top of a building, or on a tower. The Antenna Gain must be no more than 10 dB. The Roof Top Antenna location should be such that only Qualified Technical Personnel can access it, and that under normal operating conditions no other person can touch the Antenna, or approach within 10 meters of the Antenna.  •  The In-Building Antenna connection is via a coaxial cable distribution system with Signal Taps at various points connected to the fixed-mounted Indoor Antennae. This is shown in the figure in the Introduction. The Indoor Antennae are simple 1/4 Wavelength (0 dB Gain) types. They are used with KAVAL TELECOM INC. 12, 16, or 20 dB Cable Taps. As such the maximum EIRP will be at the first Tapped Antenna, which will be 12 dB below the maximum signal level of the LINKnet™ (+37 dBm); +28 dBm, or 0.63 Watts EIRP. These Antennae are to be installed such that no person can touch the Antenna, or approach within 0.2 Meters.   ANTENNA INSTALLATION WARNING  ALL ANTENNA INSTALLATION IS TO BE PERFORMED BY QUALIFIED TECHNICAL PERSONNEL ONLY.  ANTENNA INSTALLATION INSTRUCTIONS AND LOCATIONS ARE FOR THE PURPOSE OF SATISFYING FCC RF EXPOSURE COMPLIANCE REQUIREMENTS, AND ARE NOT OPTIONAL.  ALL ROOF TOP ANTENNA INSTALLATION MUST BE SUCH THAT NO PERSON CAN TOUCH THE ANTENNA, OR APPROACH CLOSER THAN 10 METERS.   ALL IN-BUILDING ANTENNAE INSTALLATIONS MUST BE SUCH THAT NO PERSON CAN TOUCH THE ANTENNAE, OR APPROACH CLOSER THAN 0.2 METERS.   Antenna Installation