Precyse Technologies BS91103001 PBS BASE STATION User Manual

Precyse Technologies Inc PBS BASE STATION

User Manual

  Precyse Technologies, Inc. Date: 7 November 2013                                                                                                   Page 1 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338      Document No.     Revision             1.3      PBS Base station BS91/103000                Release Date: 17/11/2010 Prepared by: Lior Bilia  Distribution (Check all appropriate):  Precyse Only   Project Team Only  Customer and Supplier c:\hardwarews\certification documents\pbs915\bs91510300 user manual.docx   Revision Record
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 2 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   Rev. Effective Date Description 1.0 17/11/2010 1st release  1.1  Changed from EIRP to ERP 1.2 4/6/2012 Added Regulatory disclaimer 1.3 28/10/2013 Updated modulation: 2FSK instead of GFSK, update FCC ID and label.                       Reference documents  # Doc # Description 1
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 3 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338    TABLE OF CONTENTS   Section/Title   Page  Regulatory Information/disclaimers ....................................................................... 4 Abstract ................................................................................................................. 6 Product description ............................................................................................... 6 PBS base station: .............................................................................................. 6 Technical specifications – PBS Base station 915MHz .......................................... 6 Compatibility: ..................................................................................................... 6 Performance: ..................................................................................................... 6 Communication: ................................................................................................. 6 Electrical: ........................................................................................................... 6 Environmental: ................................................................................................... 7 Certification: ....................................................................................................... 7 PBS connectors and indicators .......................................................................... 8 Schematics ........................................................................................................... 9 iLocate system block diagram ............................................................................. 10 Labels ................................................................................................................. 11 Unit definitions: ................................................................................................... 11 Antenna .............................................................................................................. 12 Appendix A: Marketing and installation ............................................................... 12
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 4 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   Regulatory Information/disclaimers Installation and use of this Wireless Radio device must be in strict accordance with the instructions included in the user documentation provided with the product. Any changes or modifications made to this device that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. The Manufacturer is not responsible for any radio or television interference caused by unauthorized modification of this device, of the substitution or attachment. Manufacturer and its authorized resellers or distributors will assume no liability for any damage or violation of government regulations arising from failing to comply with these guidelines. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Instructions concerning human exposure to radio frequency electromagnetic fields: To comply with FCC Section 1.307 (b) (1) for human exposure to radio frequency electromagnetic fields, implement the following instruction: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. The minimum distance will be determined after testing has been completed.
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 5 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338    The FCC Wants You to Know  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: a)  Reorient or relocate the receiving antenna. b)  Increase the separation between the equipment and receiver. c)  Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. d)  Consult the dealer or an experienced radio/TV technician.  FCC Warning Modifications not expressly approved by the manufacturer could void the user authority to operate the equipment under FCC Rules.
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 6 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   Abstract This document describes the iLocate system hardware: 1. PBS base station, Precyse part #BS91/103000, referred to as the PBS. Product description PBS base station: The PBS is used to communicate between the asset agents and a personal computer. It also provides synchronization signal for the system. It uses the iLocate proprietary protocol which provides a 2 way, half duplex communication with the tags and beacons.   The unit is DC powered, 12 Vdc, up to 1A. Technical specifications – PBS Base station 915MHz Compatibility:  PBS Base Station, 915MHz, versions: BS91/103000 Performance: Read rate: 250Kbps. Write rate: 250Kbps. Communication: Frequency: 902.00 – 928.00 MHz ISM license free band Modulation: 2FSK ERP: Up to 19dBm, digitally controlled Communication protocol: 2WiSAP, optional AES128 Encryption Transmission: Event base and on demand. External interfaces: Ethernet. Occupied bandwidth: 500KHz. Electrical: Power supply: 12V DC, up to 1A Safety: CE, UL compatible
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 7 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   Environmental: Size: W 180mm X L 165mm X H 32mm Operating temperature: -20°C to +85°C (-5°F to +185°F) Humidity: 90% non-condensing Enclosure: IP54 Certification: FCCID: WONBS91103001
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 8 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   PBS connectors and indicators  PBS - front view    17. External amplifier connector  18. Synch Generator (GPS Antenna)     13-16. RF Channels antennae connectors    4  2  1  3 7. DC Power port  8. Heartbeat port  9-12. TCP\IP ports 1-4     4  3  2  1 1. Power indicator  2. Synch indicator  3-6. PBS channel indicators 1-4      1  2  3  4
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 9 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   PBS - rear view Connector / indicator Description  1. Power indicator  LED (red)  On - Power is connected.  Flashing - There is a problem with the power supply. Off – power supply not connected.  2. Synch indicator  Synchronization LED (green)– Flashes once a second when the system is active  3-6. PBS channel indicators #1-4  Green LED (green) – flashes when a signal is sent on the corresponding channel  7. DC Power port DC power port (12V, 1A)  8. Heartbeat port Not used at this stage  9-12. TCP\IP port 1-4 Network connector for corresponding channel.  RJ45 connector. 13,16. RF Channel 1,4 antennae connectors Disabled RF ports. These ports are disconnected internally.  14, 15 RF transmit, RF receive – Connected to Amplifier unit. 17. External amplifier connector A DB9 connector that contains DC voltage supply and control outputs.  Warning: Do not connect this port to a computer or any other RS232 terminal equipment. 18. GPS Antenna connector GPS input port. Connect the supplied GPS antenna.  Schematics Will be provided on demand and under on-disclosure agreement.
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 10 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   iLocate system block diagram PCPBSTAG (SAT)Attached to assetsEthernetPBC1PBC2PBC3
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 11 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   Labels Label:  Label placement:  Unit definitions: Base station, referred to as PBS:  A radio device that transmits data to and from the tag (SAT) to a personal computer (PC), also provides synchronization signal. The unit is powered by a DC power supply. Beacon, referred to as PBC: A radio device that defines a location. Location detection can be realized through one or more PBCs. The unit is powered by a DC power supply. Tag (SAT): A radio device that is used to track and monitor assets. It communicates with the PBS and can detect the PBC signals.
    Precyse Technologies, Ltd.. Date: 7 November 2013                                                                                                   Page 12 of 12 Precyse Technologies 100 Ashford Center North Suite 360 Atlanta, GA  30338   Antenna Antenna for the PBS is Pasternack 51028 Specifications: Type: Half wave dipole Gain: 5dBi Impedance: 50Ohm VSWR: < 2.0:1 Polarization: Vertical Radiation pattern: Omni Appendix A: Marketing and installation  1.  The product intended use and application: The BS91103000 (PBS) is used as a radio base station for the iLocate system. By transmitting a synchronization signal, and receiving transmissions from other devices on the iLocate network it acts as a bridge between the iLocate hardware and a personal computer. 2.  The EUT is installed either indoors or outdoors (inside an appropriate sealed box). The installation requirements are proper site planning, infrastructure (AC supply with an AC to DC adapter or DC supply, mechanical mounting, clearance around it), sealed box (Per Precyse Tech’s requirements, an IP55 or equivalent box uninterrupted power supply where required, etc). 3.  Marketing: The EUT is sold to system integrators only. It is not available for the general public. The product requires non-trivial installation procedures.

Navigation menu